An Introductions to Advanced GPC Solutions

Similar documents
GPC/SEC An essential tool for polymer analysis

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

Maximizing Performance Through GPC Column Selection

Practical Steps in GPC Method Development

Optimizing GPC Separations

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Comprehensive Polymer Analysis Strategies

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Latest Developments in GPC Analysis of Adhesive and Sealant Polymers Mark Pothecary PhD Americas Product Manager Malvern Instruments

Application compendium. Authors. Greg Saunders, Ben MacCreath Agilent Technologies, Inc. A guide to multi-detector gel permeation chromatography

Differentiation of polymer branching and composition using the Mark Houwink plot

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Setting the Standard for GPC. Complete Guide for GPC / SEC / GFC Instrumentation and Detection Technologies. The Right Instrument for Your Application

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

Analysis of polyolefins by GPC/SEC

GPC/SEC standards. Product guide

EcoSEC - semi-micro GPC/SEC system for high throughput polymer analysis

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

GPC/SEC standards. Product guide

Macromolecular Chemistry

How to use GPC/SEC for compositional analysis

Malvern Macromolecular Solutions. Innovative Solutions in Material Characterization

Tips & Tricks GPC/SEC: Inter-Detector Delay

Gel Permeation Chromatography

How Molecular Weight and Branching of Polymers Influences Laser Sintering Techniques

GPC / SEC Theory and Understanding

Gel Permeation Chromatography

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Progress toward reliable NC molecular mass distribution by GPC

Tips & Tricks GPC/SEC: From a Chromatogram to the Molar Mass Distribution

Polymer Analysis by Gel Permeation Chromatography

GPC/SEC Start-up Kit

GPC/MS. Analysis of PET

Polymer analysis by GPC-SEC. Technical Note. Introduction

GPC/SEC Analysis of Polymer Degradation

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Benefit of light scattering technologies (RALS/LALS/MALS) and multidetection characterization in life science research?

food testing & agriculture

Investigating the Relationship Between the Rheological Properties of Hyaluronic Acid and its Molecular Weight and Structure using Multidetector

GPC/SEC. VARIAN, INC. Engineering Polymers ANALYSIS OF ENGINEERING POLYMERS BY GPC/SEC.

Thermoplastic. Condensation. Homopolymer. Polymer POLYMERS. Synthetic. Natural. Addition. Copolymer. Polymer. Thermosetting

Setting the Standard for Advanced GPC/SEC Systems

Sem /2007. Fisika Polimer Ariadne L. Juwono

Size-exclusion Chromatography as a Useful Tool for the Assessment of Polymer Quality and Determination of Macromolecular Properties

CASE STUDY. Degradation of Polyethylene by FTIR and High Temperature GPC

The power of multi-detector SEC in the analysis of antibodies

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

CALIBRATING GPC COLUMNS

Polymers Reactions and Polymers Production (3 rd cycle)

Supporting Information

Dr. Christoph Johann Wyatt Technology Europe GmbH Copyright Wyatt Technology Europe GmbH All Rights reserved 1

The ph-responsive behaviour of aqueous solutions of poly(acrylic acid) is dependent on molar mass

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

Relationship of Rheological Behavior and Molecular Architecture for LDPE Designed for Extrusion Coating. Bert Nijhof Technical Paper-7603

[VIM = 4 R3 gx ( 3)

Size Exclusion Chromatography

Tips & Tricks GPC/SEC: Protein Analysis with Size-Exclusion Chromatography

How switching mobile phases can improve your OMNISEC results

Physical Polymer Science Lecture notes by Prof. E. M. Woo adapting from: Textbook of Physical Polymer Science (Ed: L. H.

CHARACTERIZATION OF BRANCHED POLYMERS IN SOLUTION (I)

Effect of crystallinity on properties. Melting temperature. Melting temperature. Melting temperature. Why?

IR-LC Deposition and Detection System. Polymer Deformulation and Additive Analysis by a Single GPC-IR Run

Instrumentation & Software

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

(3) A UNIVERSAL CALIBRATION FOR GEL PERMEATION CHROMATOGRAPHY. [TIM = 4 R3 gx POLYMER LETTERS VOL. 5, PP (1967)

c) fitting of the NMR intensity in dependence of the recycle delays 4

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

Lecture No. (1) Introduction of Polymers

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS

Field-Flow Fractionation of Macromolecules and Structures That Cannot be Characterized by Conventional GPC/SEC Techniques

Supplementary Material (ESI) for Chemical Communications This journal is (c) The Royal Society of Chemistry 2008

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

SIZE EXCLUSION CHROMATOGRAPHY

Aqueous and polar GPC/SEC columns. Product guide

Molecular Weights of Copolymers Obtained by Gel Permeation Chromatography Light Scattering

Supporting information

Liquid Chromatography

PAPER No. 6: PHYSICAL CHEMISTRY-II (Statistical

Advanced GPC Technology as a Part of Solving Complex Polymer Problems

Appendix 1. GPC Characterization of Cyclic Polymers

GPC/SEC Column Selection & Method Development

Chapter 14. Molar Mass Distribution.

Organic GPC/SEC columns. Product guide

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

Branching Revealed: Characterizing Molecular Structure in Synthetic and Natural Polymers by Multi-Angle Light Scattering

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

Size exclusion chromatography of branched polymers: Star and comb polymers

Low molecular weight resins Analysis of low molecular weight. resins and prepolymers by GPC/SEC. Application compendium. Authors

Redox-Controlled Micellization of Organometallic Block Copolymers

Polymers in Modified Asphalt Robert Q. Kluttz KRATON Polymers

Size Exclusion Chromatography of Poly(2-ethyl-2-oxazoline) Homopolymers and Poly(ethylene oxide)-b-poly(2-ethyl-2-oxazoline) Copolymers

Evaluation of round robin test results for a size exclusion chromatography method for the analysis of nitrocellulose

Chap. 2. Molecular Weight and Polymer Solutions

Transcription:

An Introductions to Advanced GPC Solutions Alan Brookes Sales Manager GPC Instruments EMEAI 9 th April 2014 Agilent GPC/SEC Solutions 1

Introduction to Polymers Polymers are long chain molecules produced by linking small repeat units (monomers) together Very different physical properties are attained compared to the monomers, dependent on the length of the polymer chains Samples of synthetic polymers always contain polymer chains with a range of chain lengths affecting: Strength Toughness Brittleness Melt Viscosity Chemical Resistance Solubility Agilent GPC/SEC Solutions 2

Distribution of Polymer Chain Lengths Conventional GPC 6% 12% 70% There will usually be a large range of chain lengths in a polymer material. The GPC technique is used to measure this distribution of chain lengths 10% 2% Agilent GPC/SEC Solutions 3

Characterization of Polymers There are a variety of characteristics that influence polymer behaviour and performance. Some of the most important can be investigated using GPC and FTIR Distribution of Polymer Chain Lengths -- GPC (conventional GPC -- relative molecular weight) Molecular Weight Length of Chains -- GPC DRI Polymer Structure Branching -- GPC Different Monomer Units -- FTIR Chemical Structure of Monomer Unit -- FTIR Agilent GPC/SEC Solutions 4

What is a GPC/SEC System? A simple isocratic LC system fitted with a GPC/SEC column is a GPC/SEC system! Mode of separation only difference to other HPLC methods Specialist detectors can be used to determine properties of the samples investigated Special GPC/SEC software required to perform analysis Liquid Chromatograph GPC/SEC Column Detectors, Data Acquisition and Processing Simple isocratic system Provides solvent flow Column separates sample Into components Detectors measure the properties of eluted sample, data system provides analysis

Conventional GPC Generating Molecular Weights Calibrate the column with a set of polymer standards Plot retention time (RT) versus peak log molecular weight (logm) Calibration is used to generate molecular weights of unknowns BUT Molecular Weights are only equivalent to the Standards used So a Polystyrene calibration will give Polystyrene equivalent molecular weights for all samples analysed.

Molecular Weight Averages from Conventional GPC Mn Mw Mz Mz+1 Mp Mw/Mn - number average molecular weight - weight average molecular weight - z average molecular weight - z+1 average molecular weight - peak molecular weight - polydispersity by GPC 7

A typical GPC Case Study Testing of material batches QC Troubleshooting Background: A poly(styrene/butadiene) block copolymer is a high performance synthetic rubber. Characteristics provided by: hard polystyrene chains surrounded by a network of rubbery polybutadiene which provides strength and flexibility over a large temperature range Perfect for tyre manufacturers Dunlop, Goodyear, Hankook, Firestone. Problem: New batch of material is failing rheology testing Synthetic method to produce the copolymer has not changed End properties of the polymer significantly different to previous batches of the same material. Solution: Investigate molecular weight distribution using GPC

Instrument Requirement GPC/SEC System Precise and reproducible GPC Pump, Injector, Column Oven, Detector (RI) Flow rate precision & temperature stability Instrument, Software, Columns and Standards

Testing of material batches Analysis of synthetic rubber The GPC chromatogram shows evidence of low molecular weight material within the failed batch. Eluent : THF Columns : PLgel 5µm MIXED-D Temperature : 40 C System : 1260 Infinity GPC Detector : DRI Standard batch Failed batch RT Residual homopolymer Molecular weight averages can be calculated to give a numerical comparison With the problem identified the cause was discovered and rectified. Agilent Infinity GPC System is used to troubleshoot a production problem and improve manufacturing consistency when used as part of the QC process.

How do we improve our Polymer Analysis? Molecular weight sensitive detectors for GPC Molecular weights calculated from conventional GPC will be relative to the standards only This is because two polymers of different chemistries will interact differently with a particular solvent At any molecular weight, the two polymers will have different sizes in solution To improve our calculated molecular weights we add molecular weight sensitive detectors to our GPC system Agilent GPC/SEC Solutions May 7, 2014

How do we improve our Polymer Analysis? Molecular weight sensitive detectors for GPC Viscometer detector Response proportional to the intrinsic viscosity (IV) of the polymer Generate accurate molecular weight for polymers using the Universal Calibration principle Determination of Branching Conformation of polymer Dual angle light scattering (LS) detector Response directly proportional to molecular weight (Mw) of the polymer Absolute Molecular Weight Scattered light measured at more than one angle permits determination of Radius of gyration (Rg) a key piece of information for Polymer Chemists Determination of Branching No column calibration required Agilent GPC/SEC Solutions May 7, 2014 12

1260 Infinity GPC/SEC Multi Detector Suite Advanced detection for Absolute Accuracy Information Rich Accurately heated (ambient to 60 C) advanced detector modules: - Refractive Index - Viscometer - Dual Angle Light Scattering Low Dispersion Industry leading detector flow cell technology Agilent GPC/SEC Software Single software solution

Molecular Weights Using a Viscometry Detector The IV of the standards is used to generate a Universal Calibration. By measuring the viscosity response of the samples, true molecular weights independent of the standards used for the column calibration are calculated. Agilent GPC/SEC Solutions May 7, 2014

Molecular Weights Using a Light Scattering Detector Excess scattered light from a sample in solution is directly proportional to molecular weight (Mw). Absolute determination No reliance on column calibration so absolute molecular weights are calculated Agilent GPC/SEC Solutions May 7, 2014

Characterization of Polymers There are a variety of characteristics that influence polymer behaviour and performance. Some of the most important can be investigated using GPC and FTIR Distribution of Polymer Chain Lengths -- GPC (conventional GPC -- relative molecular weight) Molecular Weight Length of Chains -- GPC (true, absolute molecular weight) Polymer Structure Branching -- Mw -- GPC (shape and size of polymer) Different Monomer Units -- FTIR DRI Light Scattering Viscosity Chemical Structure of Monomer Unit -- FTIR Agilent GPC/SEC Solutions 16

Length of polymer chains (Mw) To measure true Molecular Weights rather than relative ones generated from conventional GPC, we can use an advanced detector which directly measures the Mw of the polymer chains A Light Scattering detector will produce a response directly proportional to the Molecular Weight (Mw) of the polymer. Sample Conventional Calibration Light Scattering Synthetic rubber Mn Mw Mn Mw 251000 604800 154700 382900 In this example the true Mw of the Synthetic Rubber is actually 37% smaller than that calculated through conventional GPC Agilent GPC/SEC Solutions 17

Advanced GPC Case Studies Analysis of polycarbonates Polycarbonates are thermoplastic polymers with excellent optical and impact resistant properties Common applications in everyday life are, sunglasses, CD s, headlights. Conventional GPC only gives you comparative molecular weights Using a viscometer detector in the you can calculate true molecular weights using a Universal Calibration

True Molecular Weights Analysis of polycarbonates Convert conventional GPC with an RI detector to advanced GPC with the addition of a Viscometer Two detectors = true molecular weights RI PS Equivalent Mw Mw = 61273 Mn = 21666 Mz = 99350 RI + Visc True Mol Wt Mw = 37815 Mn = 11376 Mz = 64712 These advanced detectors can be added to any HPLC/GPC and achieve information rich GPC...

Characterization of Polymers There are a variety of characteristics that influence polymer behaviour and performance. Some of the most important can be investigated using GPC and FTIR Distribution of Polymer Chain Lengths -- GPC (conventional GPC -- relative molecular weight) Molecular Weight Length of Chains -- GPC (true, absolute molecular weight) Polymer Structure Branching -- Mw -- GPC (shape and size of polymer) Different Monomer Units -- FTIR DRI Light Scattering Viscosity Chemical Structure of Monomer Unit -- FTIR Agilent GPC/SEC Solutions 20

Polymer Structure -- Branching Polymers may have a wide variety of branching structures depending on how they have been made or modified The branching can be further defined by the length of the branch into long chain or short chain branching Long chain branching affects the size and density of polymer molecules and is easier to measure by GPC. Agilent GPC/SEC Solutions 21

Polymer Structure -- Branching So, rather than being linear chains, many polymers have a more complex branched structure.if we use a detector that measures a different property of the polymer in solution, we extract more information about this polymer structure. A viscometer responds directly to the intrinsic viscosity (IV) of the polymer. Using this response we can generate a Mark-Houwink Plot which relates the viscosity of the polymer to molecular weight IV The slope of this plot can also indicate the shape of the polymer. Linear homopolymers have linear slopes Agilent GPC/SEC Solutions 22

Using Viscometry and Light Scattering Determination of Branching Linear versus branched polymers We can compare Mark Houwink plots of linear and branched polymers. The branched molecule will have a smaller hydrodynamic volume and Radius of Gyration compared to a linear molecule This information can be very useful when looking for evidence of branching in apparently similar polymers Agilent GPC/SEC Solutions May 7, 2014

Hyperbranched Polyesters Effect of Branching on IV Hyperbranched polyesters have been found to contribute to improved physical, chemical and mechanical properties Polyester AB/AB 2 polymers produced by the condensation of A and B end groups Branching introduced by the addition of AB 2 monomers into the reaction A Hyperbranched polymer structure is formed Different chain length AB 2 monomers can be used to vary the compactness of the polymer molecule in solution

Hyperbranched Polyesters Molecular Weight Distributions Eluent: THF (stabilised with 250 ppm BHT) Columns: 2 x PLgel 5µm MIXED-C System: Agilent 1260 Infinity Multi-detector GPC/SEC System equipped with DRI, Viscometer & Light Scattering There is no trend in molecular weight distributions.

Hyperbranched Polyesters Mark-Houwink Plots Clear trend in Mark-Houwink plots Increased branching/decreased molecular size leads to a decrease in IV

Expanding Conventional GPC/SEC Viscometer and Light Scattering Detectors Viscometers and Light Scattering detectors are powerful detectors to expand the capabilities of Conventional GPC/SEC expanding distribution only information to determining accurate molecular weights, size, shape and structure of the polymer. GPC/SEC Technique Conventional (RI or UV) Viscometry Molecular Weight Molecular Size Information Relative to standards used for calibration More accurate from Universal Calibration No Yes, hydrodynamic radius (Rh). Light Scattering Absolute determination Yes, Radius of Gyration (Rg) directly. Triple Absolute determination Yes, Rg and Rh, directly. Molecular weight distribution, concentration Conformation, branching. Works with copolymers Conformation, branching. The ultimate configuration for comprehensive polymer characterisation Agilent GPC/SEC Solutions ANFF-Q August 20th 27

Summary The Value of GPC Molecular weight distribution is critical for the polymer chemist, with further information obtained from the same experiment using advanced detectors such as Light Scattering and Viscosity Distribution of Polymer Chain Lengths -- GPC Molecular Weight Length of Chains -- GPC Polymer Structure Branching -- GPC Maximising the technique of GPC is extremely valuable to the polymer chemist and is widely used today in key stages of the polymer industry: Quality Control/Production Polymer R&D Product Troubleshooting Agilent GPC/SEC Solutions 28

Agilent GPC/SEC Portfolio Aqueous GPC RT-GPC Multi Detector GPC Conventional GPC Organic GPC HT-GPC

Agilent GPC/SEC Software Single solution for all GPC/SEC Requirements Control of Agilent GPC/SEC Systems Collection from Agilent GPC/SEC Systems All GPC/SEC Calculations

Agilent GPC Instrumentation Portfolio Agilent 1260 Infinity GPC-SEC system Agilent 1260 Infinity-MDS Multi Detector Suite Agilent GPC/SEC Software Agilent PL-GPC 50 Ambient to 50 C Agilent PL-GPC 220 Ambient to 220 C

Thanks for Listening Any Questions