Digital Fluxmeter CYHT700SP

Similar documents
2.2 Operating Condition Temperature Range:5~40

Acceleration/Velocity/Displacement VIBRATION METER

e/m APPARATUS Instruction Manual and Experiment Guide for the PASCO scientific Model SE D 5/ PASCO scientific $5.

Physical Structure of Matter. Hall effect in p-germanium Solid-state Physics, Plasma Physics. What you need:

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

VIBRATION METER. Instruction Manual.

3B SCIENTIFIC PHYSICS

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics.

Electricity. Measuring the force on current-carrying conductors in a homogeneous magnetic field. LEYBOLD Physics Leaflets P

Charge to Mass Ratio of The Electron

Electromagnetic Induction & Inductors

Lab 7: EC-5, Faraday Effect Lab Worksheet

EE 3324 Electromagnetics Laboratory

1 (a) Define magnetic flux [1]

Charge to Mass Ratio of The Electron

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Operating Instructions for Digital Manometer. Model: MAN-SD

INSTRUCTION MANUAL FOR MM10 Relay

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

TH2821B Portable LCR Meter

INE-PHS-3E ph Meter Operating Manual

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Thermal-Magnetic Circuit Breaker 2210-S2..

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

473 Dew Point Hygrometer

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

Vet Photometer DP 700 Operating Manual. Version V5.9

Exp. #2-4 : Measurement of Characteristics of Magnetic Fields by Using Single Coils and a Computer Interface

Magnetic Fields. Experiment 1. Magnetic Field of a Straight Current-Carrying Conductor

Magnetic field of single coils / Biot-Savart's law

473 Dew Point Hygrometer

Thermal-Magnetic Circuit Breaker 2210-S2..

DIGITAL THERMOMETER OPERATOR S MANUAL

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

Thermal-Magnetic Circuit Breaker 2210-S2..

Instruction Manual for EP-20 e/m of the Electron Apparatus

Ion-Chamber Survey Meter OD-02

SCS 139 Applied Physic II Semester 2/2011

Dual laser + type K thermometer INFRARED THERMOMETER

LEP Hall effect in p-germanium with Cobra3

Impedance relay and protection assemblies

THE CHARGE-TO-MASS RATIO OF THE ELECTRON (e/m)

MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8

Bright Advance Corporation

Laboratory 14: Ratio of Charge to Mass for the Electron

QUESTION BANK DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING UNIT I - INTRODUCTION SYLLABUS

INNOVATION IN MAGNETICS DS0003/18. Mag-01H. Single Axis Fluxgate Magnetometer.

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

1450 First Ave. Page 1 of 10 Chippewa Falls, WI (800) or (715) Fax: (715)

2. OPERATIONAL CONDITIONS

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Type Plunger Height x pitch Operating force (OF) Without ground terminal Flat type 4.3 x 6.5 mm General 0.98 N (100 gf) B3F-6000 B3F-6100

3/8" Square Panel Potentiometer Miniature - Cermet - Fully Sealed

Lab 1: Determination of e/m for the electron

Solution for Fq. A. up B. down C. east D. west E. south

Oberebenestrasse Bremgarten Switzerland Tel Fax

Three Axis Magnetic Field Transducer x-h3x-xx_e3d-2.5khz-1-0.2t

RC Circuit (Power amplifier, Voltage Sensor)

Rotational Motion. Figure 1: Torsional harmonic oscillator. The locations of the rotor and fiber are indicated.

Decade Capacitance System

Exercise 1: Capacitors

INE-DDB-303A Portable Conductivity Meter Instruction Manual

a) head-on view b) side view c) side view Use the right hand rule for forces to confirm the direction of the force in each case.

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Lab 4: The Classical Hall Effect

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

/15 Current balance / Force acting on a current-carrying conductor

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Elementary charge and Millikan experiment Students worksheet

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Brown University PHYS 0060 Physics Department LAB B -190

Thermal-Magnetic Circuit Breaker 2210-S2...

Do not fill out the information below until instructed to do so! Name: Signature: Section Number:

Thermal-Magnetic Circuit Breaker 2210-S2...

473-SHX Dew Point Mirror

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

ATOMIC PHYSICS PHOTOELECTRIC EFFECT Practical 2 DETERMINATION OF PLANCK S CONSTANT BY MEANS OF THE STOPPING POTENTIAL

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Silicon carbide Power MOSFET 650 V, 90 A, 18 mω (typ., T J = 25 C) in an H²PAK-7 package. Order code V DS R DS(on) max. I D

Model HHG 21 GAUSS / TESLA METER

Anemometer Thermometer Hygrometer

DATA SHEET WIEGAND WIRE SENSOR WS-UTS-0-U0, WS-UFS-0-U0

PHOENIX CONTACT - 04/2016. Features

RAYTECH USA, Inc. 90C Randall Avenue, Woodlyn, PA USA Tel Fax Instruction Manual

Magnetic Quantities. Magnetic fields are described by drawing flux lines that represent the magnetic field.

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Industrial Pressure Transmitter

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Electric Field Mapping

Model 5060 GAUSS / TESLA METER

MODULE 6 ELECTROMAGNETISM MAGNETIC FIELDS MAGNETIC FLUX VISUAL PHYSICS ONLINE

DATA SHEET WIEGAND WIRE SENSOR WS-UTS-4-U0, WS-UFS-4-U0

Transcription:

1. Introduction Digital Fluxmeter CYHT700SP User s Manual (Version2) The Fluxmeter CYHT700SP is an electronic integrating, digital displayed instrument with high sensitivity and small drift. The Fluxmeter can be used not only for the measurement of the magnetic flux of permanent magnets, but also for quality control and sorting of magnetic products. Its versatility makes the employment possible in laboratory enterprise as also in production. This Fluxmeter has the functions such as maximum value hold and automatic pole indication and 4 measuring ranges. It can be used also for measurement of impulse magnetic field 2. Technical Data Range Display Range Effective Range Resolution Input resistance 1mwb 0~±1.999mwb 10-5 ~10-3 wb 0.001mwb 10kΩ 10mwb 0~±19.99mwb 10-4 ~10-2 wb 0.01mwb 100kΩ 100mwb 0~±199.9mwb 10-3 ~10-1 wb 0.1mwb 1MΩ 1000mwb 0~±1999mwb 10-2 ~1wb 1mwb 10MΩ ChenYang Technologies GmbH & Co. KG Markt Schwabener Str. 8 85464 Finsing, Germany Tel. +49-(0)8121-2574100 Fax: +49-(0)8121-2574101 Email: info@chenyang-gmbh.com http://www.chenyang-gmbh.com Accuracy: ±1.0% Instability/drift: ±5 Digits/10s, ±10 Digits/min Display: 3 ½ LED, automatic polarity display Output signal: 0-2V DC analogue Functions: Maximum value hold, automatic polarity indication Sorting: setup maximum & minimum limits Red LED: higher than maximum limit Yellow LED: lower than minimum limit Green LED: within the tolerance (PASS) Ambient temperature: 5 C ~ 40 C Storage temperature: -25 C ~ +55 C Warm-up time: 30min Relative humidity: 20% ~ 80% Power supply: AC 220V, 50Hz Dimensions: 280mm x 240mm x 95mm Weight: 2.0kg 2

3. Accessories Helmholtz coil 1 piece (From measuring coil) Input Input current Integrator Buffer & Hold A/D Structure: Ø100 x 50mm 4. Special Coil Dimension: Ø100 x 85mm (Standard) Note: The outer diameter of measuring object should be smaller than Ø40mm Custom made coil (additional purchase order) Custom made coil for segment/block magnets (Additional purchase order is needed) Power supply Zero circuit Display A current is induced by the change of magnetic flux Ф passing through a measuring coil. The current is the input of the fluxmeter. After the integration of the current one obtains a DC voltage signal, which is proportional to the change of the magnetic flux. The DC voltage is converted into digital signal and displayed by the LEDs. Thus the magnetic flux can be measured in this way. According to the electromagnetic induction principle the magnetic flux Ф can be written as B N S (1) Where: B: Magnetic flux density applied to measuring coil (Tesla) N: Windings of the measuring coil S: Sectioned area of the measuring coil (m 2 ) On the other hand the magnetic field can be determined by B N S (2) Driver Therefore one can determined the magnetic field after measuring the magnetic flux passing through the measuring coil. 5. Measuring Principle This series of Fluxmeter measures the flux Ф of a magnetic field by using the electromagnetic induction principle and electronic integration method. The diagram of the measuring system is shown in the following figure. 3 6. Parts and Functions The power supply socket outlet (15) and the voltage output connector (16) are on the back panel of the fluxmeter. Connect the voltage output (0-2VDC) to multimeter or to A/D and computer if it is necessary. 4

Front Panel (2) (11) (6) (7) (12) (9) (13) (10) (1) (8) (4) (5) (3) (14) Back Panel (15) 220VAC,50Hz (16) Output 5 Parts: 1: Power Button 2: LED display 3: Input socket outlet 4: Measuring button 5: Measuring range 6: Coarse adjustment 7: Fine adjustment 8: Peak value hold 9: Sorting Setup 10: High /Low Setting 11: High /Low value adjustment 12: Selection 13: Classification LEDs 14: RESET 15: Power socket outlet 16: Analogue voltage output. Functions: 1) Power button: to switch ON/OFF the fluxmeter 2) LCD display: to display the magnetic flux and pole direction ( + : north pole, - : south pole). 3) Input socket outlet: to connect the measuring coil to the fluxmeter 4) Measuring button: press this button to measure the magnetic flux 5) Measuring range: to select the measuring range: 1mwb, 10mwb, 100mwb and 1000mwb 6) Coarse adjustment: to adjust the drift compensation coarsely 7) Fine adjustment: to adjust the drift compensation finely 8) Peak value hold: to display and hold the peak/max value 9) Sorting setup: to set the maximum and minimum value for sorting the measuring object 10) High/Low setting: Press this button to set the Low limit value; release the button to set the High limit value 11) High/Low value adjustment: to change the High/Maximum value and the Low/Minimum value 12) Selection: press this button to let the Fluxmeter to work in the selection mode 13) Classification: to indicate the selection result: HIGH: Measuring value > Maximum value Pass (GO): Minimum measuring value Maximum LOW: Measuring value < Minimum 14) RESET: reset the display to zero 15) Power socket outlet: to connect the power supply 220VAC, 50Hz 16) Analogue voltage output: to output an analogue voltage 0-2.0V DC 6 Range Measuring Range Output Range 1mwb 0~±1.999mwb 0 ~ ±2V 10mwb 0~±19.99mwb 0 ~ ±2V 100mwb 0~±199.9mwb 0 ~ ±2V 1000mwb 0~±1999mwb 0 ~ ±2V

7. Measuring Procedure 1) After connecting the power supply to the power socket outlet (15) of the fluxmeter press the button POWER (1) to switch ON the fluxmeter. The LED display (2) is on. 2) Connect the measuring coil (for instance Helmholtz Coil) to the INPUT (3) of the fluxmeter. 3) Press the button MEAS (4) and select a suitable measuring range such as 10, 100 and so on (Please select the highest range when the range is unpredictable.). 4) Drift Adjustment: after pressing the measuring button MEAS (4) the LED display (2) will show a random value. The displayed value will increases in one direction continuously. This value drift is caused by the accumulation of the signal drift of the integrator in the fluxmeter. The adjustment is in the right turning direction if the drift value changes slowly during adjusting the drift with the zero potentiometer COARSE (6). Otherwise, you should reverse the turning direction of the adjustment until the drift value changes considerable slowly. In this case one can also use the FINE (7) potentiometer to adjust the drift. Press the RESET (14) button after the drift value has been stable. The LED should display zero. If the display is still not to zero one should not stop the adjustment until the display is zero. The zero point will be more stable if you use the FINE (7) potentiometer to adjust the drift. 5) Measurements: after the drift adjustment you can start the measurement in the following ways: (1) Positive Measurement: Press the RESET (14) and put the measuring object (e.g. permanent magnet) into the measuring coil. Please note the magnetization direction of measuring object should be the axial direction of measuring coil. The LED shows the measuring value of the flux of the measuring object. Please read and write down the measuring value immediately. The North Pole is on the top side of the measuring object if the display value without any symbol (in fact it is + ). South Pole is on the top side if you get the minus value from the display. (2) Negative Measurement: Put the measuring object (e.g. permanent magnet) into the measuring coil and press the RESET (14) and then take the measuring object far away from the measuring coil and read /write down the display value immediately. This value is the measuring flux result of the measuring object with opposite symbol. You should reverse the symbol of the measuring value in order to get the right magnetic pole of the measuring object. (3) Average Measurement: In order to get the accurate measuring value you can use the positive measurement and negative measurement and then calculate the average of the two measuring results. The average value is considered as the measuring result. Here is the measuring procedure: Press the RESET (14) and put the measuring object (e.g. permanent magnet) into the measuring coil. Read and write down the first measuring value immediately. Press the RESET (14) again and take the measuring object far away from the measuring coil and read /write down the second measuring value immediately. Note: The value will be changed after a time period because of the electrical signal drift. Therefore the measurement should be finished in a few seconds. This means that you should read the measuring value immediately after taking the measuring object from the measuring coil. 6) Peak Value Hold: press HOLD (8) and RESET (14) and put the measuring object (e.g. permanent magnet) into the measuring coil. The maximum value will be displayed and hold even if the measuring object is removed from the measuring coil. Press RESET (14) before the next measurement in order to reset the maximum value. N S NdFeB Block Magnet Magnetization direction + : North Pole - : South Pole Helmholtz Coil Note: Drift adjustment is necessary under pressing MEAS (4) before measurement. In HOLD mode a drift adjustment is not possible. 7) Selection Function Selection function is mainly used to online test the magnetic performance of products. After pre-setting up the maximum and minimum flux limits of the products, one will get three classifications: (1) lower than minimum limit LOW (yellow); (2) between the two limits GO (Pass, green); (3) higher than the 7 8

maximum limit HIGH (red). Using the result, the eligibility of the products can be distinguished. The selection system is composed of functional switches, setup adjustment and classification display. The functional switches include SELECT (12), HIGH/LOW (10) and SET (9). After pressing SELECT (12), the instrument switches to the selection mode. By pressing SET (9), the instrument switches automatically to the setup status. Use the HIGH/ LOW button to adjust the potentiometer to the maximum and minimum limits. Under the SELECT mode measurement and selection can be carried out simultaneously. When both SELECT (12) and SET (9) buttons are released, the instrument switches to the measurement mode. Operation instruction (1) After pressing SET (9) set the LOW/HIGH (10) button at HIGH position and adjust HIGH potentiometer to make the display to the maximum limit MAX. 1000 indicates the full range (excluding the radix point) (2) Press SET (9) and set the LOW/HIGH (10) button at LOW position, and adjust LOW potentiometer to read the minimum limit MIN on the display. Note: the maximum limit must be higher than the minimum limit. The minimum limit will change with the adjustment of the maximum limit while the maximum limit doesn t change with the adjustment of the minimum limit. (3) By pressing SELECT (12), the instrument switches to the selection mode. The LOW (yellow) LED will be on when the display is reset to zero because zero is lowest value. (4) The measurement can be taken only after the correct setting. Apart from the direct digital display of the measurement result X, the comparative result between the measurement result and the MAX/MIN limits will be displayed by the LEDs: Red LED: X > MAX Green LED: MIN X MAX (product is eligible) Yellow LED: X < MIN. (5) When the SELECT and SET buttons are released to the original status, the instrument exits from the selection mode, and all LEDs are switched off. The measurement mode and hold mode are available again. 9 8. Applications The fluxmeter CYHT700SP can be used for measuring the inner flux of permanent magnets (block, disc/cylinder, ring and segment) with a Helmholtz coil or simple single coil. 8.1 Flux Measurement with Helmholtz Coil Helmholtz Coil Helmholtz coil refers to a device for producing a region of nearly uniform magnetic field. It consists of two identical circular magnetic coils that are placed symmetrically one on each side of the experimental area along a common axis, and separated by a distance h equal to the radius R of the coil. Each coil carries an equal electrical current flowing in the same direction. Reversely a current will be generated in the Helmholtz coil when a permanent magnet is placed in the center of the coil. The flux passing through the coil can be determined by measuring the current with the fluxmeter. Measuring Procedure Connect the signal output of the coil to the fluxmeter INPUT (3) and adjust the height of the measuring platform in the coil in order to be suitable for the measurement. The best position of the measuring object is determined by the center point of the measuring object. The center point should be at the center of the viewing hole of the coil. 10 Signal Output Measusing Platform Viewing Hole Measuring Object

Put the measuring object on the measuring platform at the center of the coil. Measure the flux of the object according to the measuring methods mentioned above (see measurements in the section 7). Calculation of Magnetic Flux Density B The magnetic flux density B can be written as follows: RC B C (1 ) V Rin (3) Where B: Magnetic flux density (in Gs) Ф: Magnetic flux, measured (in Maxwell) R in : Input resistance of Fluxmeter C: Coil constant (in cm), R C : Coil resistance V: Volume of the measuring object (in cm 3 ) 1mwb = 100000 Maxwell = 10 5 Maxwell Note: The inner diameter of the Helmholtz Coil should be at least 2.5 times of the outer diameter of measuring object. Examples: Measurements of NdFeB Magnets (material grade N38) Magnet Size (mm) Coil constant C Flux Ф (mwb) B (Gs) Block 20x20x20 0.01294cm 76.4 12357.7 Disc Ø12 x 10 0.01294cm 11.2 12821.0 Ring Ø20xØ8x5 0.01294cm 12.0 11774.0 8.2 Flux Measurement of Segment/Block Magnets The magnetic flux of segment or block magnets can be measured with a special coil shown bellow. Y Direction Signal Output Y Position Adjustment X Position Adjustment X Direction Magnet Position 11 Adjust the X and Y position of magnet by using the X and Y adjustment knobs. The scale value in X direction should be equal to the half of the width of the magnet and scale value in Y direction equal to the half of length of the magnet. Place the segment magnet to the magnet position. One vertex angle of the magnet should be connected to the right angle of X direction scale. Measure the flux of the object according to the measuring methods mentioned above (see measurements in the section 7). 9. Warranty Measuring instrument: Helmholtz coil: 10. Service 12 months after shipment 12 months after shipment Please contact us for technical questions, repairing and replacement etc: 12 X Scale ChenYang Technologies GmbH & Co. KG Markt Schwabener Str. 8 85464 Finsing, Germany Tel. +49-(0)8121-2574100 Fax: +49-(0)8121-2574101 Email: info@chenyang-gmbh.com http://www.chenyang-gmbh.com Right angle Segment Magnet