Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

Similar documents
PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features

Product Data. Brüel & Kjær B. Sound Power Source Type Introduction

Accurate Determination of Loudspeaker Parameters using Audio Analyzer Type 2012 and Laser Velocity Transducer Type 3544

Application Note. Brüel & Kjær. Tyre Noise Measurement on a Moving Vehicle. Introduction. by Per Rasmussen and Svend Gade, Brüel & Kjær, Denmark

Keysight Technologies Measurement Uncertainty of VNA Based TDR/TDT Measurement. Application Note


LD1117A SERIES LOW DROP FIXED AND ADJUSTABLE POSITIVE VOLTAGE REGULATORS

LD29300xx. 3 A, very low drop voltage regulators. Features. Description

KD A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED

This document is a preview generated by EVS


QUICK REFERENCE DATA. Pilkor components FEATURES APPLICATIONS

CERTIFICATE OF CALIBRATION

Order codes Part numbers DPAK (tape and reel) PPAK (tape and reel)

2017 Source of Foreign Income Earned By Fund

Series Impedance PCX2 347 Film capacitors

ORGANISATION FOR ECONOMIC CO-OPERATION AND DEVELOPMENT

LD1117A SERIES LOW DROP FIXED AND ADJUSTABLE POSITIVE VOLTAGE REGULATORS

CERTIFICATE OF CALIBRATION

Quick Guide QUICK GUIDE. Activity 1: Determine the Reaction Rate in the Presence or Absence of an Enzyme

L79L00 SERIES NEGATIVE VOLTAGE REGULATORS

L7800AB/AC SERIES PRECISION 1A REGULATORS

WEATHER STATION FIELD GUIDE

792A AC/DC Transfer Standard

74VHCT138ATTR 3 TO 8 LINE DECODER (INVERTING)

BSH Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

Interference Suppression PCX2 335 film capacitors

Keysight Technologies Instrumented Indentation Testing with the Keysight Nano Indenter G200. Application Note

ST3L01 TRIPLE VOLTAGE REGULATOR

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

STTH6004W. Ultrafast high voltage rectifier. Table 1: Main product characteristics I F(AV) 60 A V RRM. 400 V T j (max) 175 C V F (typ)

Cyclone Click to go to the page. Cyclone

-55 ~ IEC (3rd edition) and EN Safety approvals

INNOVATION IN MAGNETICS DS0003/18. Mag-01H. Single Axis Fluxgate Magnetometer.

FINAL REPORT ON KEY COMPARISON APMP.AUV.A-K3

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Interference Suppression PCX2 337 film capacitors

792A AC/DC Transfer Standard

Obsolete Product(s) - Obsolete Product(s)

Appendix B: Detailed tables showing overall figures by country and measure

Microbial DNA qpcr Multi-Assay Kit Clostridium perfringens Pathogenicity

[ Care and Use Manual ]

L7800 SERIES POSITIVE VOLTAGE REGULATORS

L7800 SERIES POSITIVE VOLTAGE REGULATORS

5730A High Performance Multifunction Calibrator. Extended specifications

Keysight Technologies Oxygen-Free High-Resolution Electrochemical SPM. Application Note

Interference Suppression film capacitors

International Standardization for Measurement and Characterization of Nanomaterials

LD1117 SERIES LOW DROP FIXED AND ADJUSTABLE POSITIVE VOLTAGE REGULATORS

Provläsningsexemplar / Preview TECHNICAL REPORT INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE

Obsolete Product(s) - Obsolete Product(s)

Uncertainties associated with the use of a sound level meter

Report on Key Comparison COOMET.AUV.A-K5: Pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 khz

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Consultancy Report Ref: 9383-R01

Obsolete Product(s) - Obsolete Product(s)

L78L00 SERIES POSITIVE VOLTAGE REGULATORS

Interference Suppression film capacitors

7.5A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED. October 2002

Obsolete Product(s) - Obsolete Product(s)

Keysight Technologies Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation. Application Note

M74HC20TTR DUAL 4-INPUT NAND GATE

STTH60R04. Ultrafast recovery diode. Main product characteristics. Features and benefits. Description. Order codes


2N3904 SMALL SIGNAL NPN TRANSISTOR

How Well Are Recessions and Recoveries Forecast? Prakash Loungani, Herman Stekler and Natalia Tamirisa

Microphone HALT Report

AN1755 APPLICATION NOTE

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

AN2970 Application note

. DIRECTLY CALIBRATED IN o K. . 1 o C INITIAL ACCURACY. . OPERATES FROM 450µA TO 5mA .LESS THAN 1Ω DYNAMIC IMPEDANCE LM135 LM235-LM335,A

Export Destinations and Input Prices. Appendix A

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

STTH61R04TV. Ultrafast recovery diode. Main product characteristics. Features and benefits. Order codes. Description A1 K2 ISOTOP ISOTOP STTH61R04TV1

STTH6110TV. Ultrafast recovery - high voltage diode. Main product characteristics. Features and benefits. Order codes. Description ISOTOP ISOTOP

Obsolete Product(s) - Obsolete Product(s)

Tel: Fax: PRODUCT INFORMATION

Static pressure and temperature coefficients of working standard microphones

MC MC35172 LOW POWER DUAL BIPOLAR OPERATIONAL AMPLIFIERS.. GOOD CONSUMPTION/SPEED RATIO : ONLY 200µA/Amp FOR 2.1MHz, 2V/µs

PHT4NQ10LT. 1. Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

STPS1L40M LOW DROP POWER SCHOTTKY RECTIFIER. Table 1: Main Product Characteristics I F(AV) V RRM. 1 A 40 V T j (max) 150 C V F (max) 0.

L78LxxAB L78LxxAC - L78LxxC

Obsolete Product(s) - Obsolete Product(s)

Keysight Technologies Young s Modulus of Dielectric Low-k Materials. Application Note

STD5N20L N-CHANNEL 200V Ω - 5A DPAK STripFET MOSFET

T4 Series 4A TRIACS. Table 1: Main Features Symbol Value Unit I T(RMS) 4 A. V DRM /V RRM 600 to 800 V. I GT (Q1 ) 5 to 35 ma

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Measuring Instruments Directive (MID) MID/EN14154 Short Overview

Table 3: Absolute Ratings (limiting values) Symbol Parameter Value Unit I T(RMS)

04 June Dim A W V Total. Total Laser Met

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

TIMSS 2011 The TIMSS 2011 School Discipline and Safety Scale, Fourth Grade

TEA6422 BUS-CONTROLLED AUDIO MATRIX

M74HC147TTR 10 TO 4 LINE PRIORITY ENCODER

Bilateral Labour Agreements, 2004

The New Quintix. Intuitive application guideance. Maximum accuracy at all time. Easy cleaning. Plug & Work connectivity to printer or computer

T810H. High temperature 8 A sensitive TRIACs. Features. Applications. Description. Medium current TRIAC

DO-15 DO-201AD STTH3R04Q STTH3R04

AN922 Application note

Simulation of Horn Driver Response by Direct Combination of Compression Driver Frequency Response and Horn FEA

Transcription:

Product Data Sound Intensity Calibrator Type 3541 USES: Sound intensity and particle velocity calibrations Sound pressure calibration Measurement of pressure-residual intensity index FEATURES: Intensity coupler for simulating a plane sound wave in a free field (US. pat. No. 4715219) Pistonphone for sound intensity, particle velocity and sound pressure calibrations Broad-band sound source for pressure-residual intensity index measurement Type 3541 enables calibration of intensity measuring instruments by using a coupler designed especially for sound intensity calibrations. Intensityprobe microphones are positioned in the coupler which, in conjunction with a pistonphone, simulates a plane sound wave propagating along the axis of the probe. The instrument s sensitivity to both sound intensity and particle velocity can then be calibrated. The pistonphone can also be used for sound pressure calibrations. In addition to calibration, Type 3541 can be used to measure the pressure-residual intensity index spectrum of instruments used for measuring sound intensity. Sound Intensity Calibrator Type 3541 enables instruments which measure sound intensity to be calibrated against simulated sound intensity and particle velocity levels. Instruments and microphones cannot be considered fully calibrated if only the sound pressure sensitivities of the individual microphone channels are calibrated. Calibration with the simulated sound intensity and particle velocity levels of Type 3541 ensure that these parameters can be measured correctly. Type 3541 is intended for use with Brüel & Kjær Sound Intensity Probes Types 3583 or 3584 (or earlier Types 3545 or 3548) with a Sound Intensity Microphone Pair Type 4181. Other microphone pairs have much higher vent sensitivities and this restricts Fig.1 Type 3541 components in their case. Main components: Intensity Coupler, Pistonphone, Sound Source. Other components: Correction Barometer, Dummy Microphone, 1 / 4 Microphone Adaptors (two), Microphone Adaptors for Pistonphone ( 1 / 2, 1 / 4 and 1 / 8 ), 10 32 UNF to BNC Adaptors (two). In lid: Calibration Charts, Electrical Output Cables their use; see Microphones and Vent Sensitivity. A simplified cross-section of the intensity coupler is shown in Fig. 2. It consists of two chambers connected by a coupling element. When the pistonphone is attached to the coupler there is a phase difference between the sound pressures in the upper and lower chambers. The amplitude of the sound pressure is the same in both chambers, so a plane sound wave propagating in a free field is simulat- Dummy microphone (removable) Microphone B Pistonphone or sound source Upper chamber Microphone A Coupling element Lower chamber 871887/1e Fig.2 Simplified cross-section of intensity coupler Brüel & Kjær B K

ed. If one microphone is positioned in the upper chamber and the other in the lower chamber, then the simulated sound wave can be used for calibrating the sensitivity of the measuring instrument to sound intensity and particle velocity. The coupler and pistonphone can also be used for calibration of sound pressure sensitivity. For this, the microphones are both positioned in the upper chamber. Then they are exposed to exactly the same sound pressure (amplitude and phase). The broad-band sound source is supplied for measurement of the pressure-residual intensity index spectrum. This is used to assess the accuracy of sound intensity measurements. A calibration chart is supplied which states the levels that should be detected during calibration. The chart also gives information about corrections to the calibration levels for use when conditions are different from the stated reference conditions. A correction barometer determines correction terms to the sound pressure and particle velocity calibration levels due to changes in atmospheric pressure. The sound intensity calibration level is independent of any change in atmospheric pressure. Calibration Procedure Full calibration of an intensity measuring instrument and its microphones includes: p A Microphones p B Fig.3 Simplified block diagram of an intensity measuring instrument. The signals from two pressure microphones, p A and p B, are used to determine the pressure at the midpoint on the probe axis, p, and the particle velocity along the probe axis, u r. Multiplying p and u r gives the intensity reading I r. r is the microphone spacing and ρ is the density of air sound pressure calibration of the individual microphone channels sound intensity and particle velocity calibration measurement of the pressure-residual intensity index spectrum of the system. Sound pressure calibration Fig. 4 shows Pistonphone Type 4228 fitted to the coupler, and both microphones positioned in the upper chamber of the coupler. With this arrangement, the pistonphone produces the same sound pressure level at each microphone. The microphone channels are calibrated against this known sound pressure level. Sound intensity and particle velocity calibrations Fig. 3 is a block diagram showing how sound intensity is measured. The + + + Σ Σ p A + p B p = 2 u r = p A p B dt ρ r X l r = p u r 871673/2e particle velocity signal is obtained by integrating, with respect to time, the instantaneous difference in sound pressure between the two microphones. This signal is zero during a sound pressure calibration, so the correct functioning of the instrument is not confirmed. Fig. 5 shows the pistonphone fitted to the coupler, and the microphones positioned in different chambers of the coupler. With this arrangement, the coupler causes a phase change between the sound pressures at the microphones, corresponding to a nominal spacing of 50 mm with no reflections. The phase change between the sound pressures simulates the sound intensity and particle velocity levels, so that the pressure-difference signal for the integrator is not zero. Only now is the correct functioning of the instrument confirmed. Fig.4 Arrangement for sound pressure calibration Fig.5 Arrangement for sound intensity and particle velocity calibrations Fig.6 Arrangement for measuring residual intensity and pressure-residual intensity index 2

Residual Intensity 1. A sound wave is incident on a probe axis at 90. There is no flow of acoustic energy along the probe axis. The signals from the microphones are in phase and no intensity is detected. 2. If a sound wave is incident at an angle other than 90, then acoustic energy flows along the probe axis. The microphone signals are out of phase and intensity is detected. 3. In practice, if a sound wave is incident at 90, then small differences between the phase responses of the microphones cause a small phase difference between the microphone signals. There now appears to be a flow of acoustic energy along the probe axis. 4. It is this apparent flow of acoustic energy that is detected and called residual intensity. 1 3 Signals are in phase Signals are not in phase Ideal probe with no phase mismatch Intensity No intensity is detected 870897/1e Real probe with phase mismatch Intensity is detected 871837/1e Even under controlled laboratory conditions, it is very difficult to create a free-field situation where the angle between the propagation of the sound wave and the probe axis is exactly 90 degrees (as shown in boxes 1 and 3). However, for practical applications this situation can easily be simulated using the set-up shown in Fig. 6. 2 Signals are not in phase 4 db Ideal probe with no phase mismatch Intensity is detected SPL Residual intensity Frequency 871838/1e 870899/2e Pressure-residual intensity index measurement The box at the top of the page shows how small differences in the phase responses of the microphones and input channels result in the detection of residual intensity. Residual intensity is a parameter that should be taken into account when interpreting measured intensity data. It is worth noticing that the residual intensity spectrum is not a fixed one; it is tied to, and rises and falls with, the measured sound pressure level. Fig.6 shows an arrangement for measuring pressure-residual intensity index. The broad-band sound source is fitted to the coupler and the microphones are positioned in the upper chamber. The broad-band sound source produces pink noise, so the sound pressure spectrum measured in the coupler is constant (in octave bands) over a wide frequency range. Both microphones are exposed to the same sound pressure, so any intensity detected is residual intensity. It can be shown that, for a given measurement system and frequency, the difference between measured sound pressure level and detected residual intensity level will be a constant. This constant difference is called the pressure-residual intensity index. The pressure-residual intensity index spectrum can be measured with the arrangement shown in Fig. 6 by subtracting the detected intensity spectrum from the sound pressure db 70 60 50 40 30 20 10 0 Fig.7 Intensity and sound pressure levels measured with the arrangement shown in Fig. 6. The pressure-residual intensity index spectrum is characteristic of the measurement system and is obtained by subtracting these two spectra db 60 50 40 30 20 10 Residual pressure - intensity index 63 125 250 500 1k 2k 4k Hz Measured SPL SPL in coupler Intensity level in coupler Residual intensity level Measured intensity level 63 125 250 500 1k 2k 4k Hz 871670/2e 871671/1e Fig.8 Sound intensity and mean sound pressure spectra measured in the field with an instrument calibrated with Type 3541. The residual intensity spectrum is obtained by subtracting the pressure-residual intensity index spectrum in Fig. 7 from the measured SPL spectrum 3

spectrum. An example of this is shown in Fig. 7. Residual Intensity Level If a pressure-residual intensity index spectrum is to be used to assess the accuracy of sound intensity measurements, then the mean sound pressure spectrum in the field must also be measured. The residual intensity level is then quickly established by subtracting the pressure-residual intensity index spectrum from the measured mean sound pressure spectrum. An example of this is shown in Fig. 8. The residual intensity level is then compared to the measured sound intensity level. It can be shown that, for a certain frequency, the residual intensity level must be at least 7 db lower to ensure a measurement error of less than 1 db. The residual intensity level shown in Fig. 8 is dependent on the sound pressure level measured in the field and should not be confused with the intensity level which is measured with the arrangement shown in Fig. 6. Microphones and Vent Sensitivity The coupler, UA 0914, has been designed to work with Microphone Pair Type 4181 which have an extremely low sensitivity to sound pressure at their pressure-equalization vents. When microphones are inserted into the coupler, their diaphragms are exposed to the sound pressure in the coupler but their pressure-equalization vents are not. Coupler UA 0914 cannot be used to measure the pressure-residual intensity index with conventional microphone pairs as they have vent sensitivities several orders of magnitude higher than that of Type 4181. It can, however, be used with conventional microphone pairs for calibration of sound pressure, sound intensity, and particle velocity. 4

Specifications Type 3541 Intensity Coupler UA 0914 FIRST CHAMBER: Ports 1 and 2 SECOND CHAMBER: Port 3 CHAMBER VOLUME: 10 cm 3 each EQUIVALENT LOAD FOR EACH PORT: 250 mm 3 Sound Source ZI 0055 ATTENUATION OF OUTPUT: 0 to 10 db (variable) BATTERY: 1 9 V Alkaline Battery, type 6 LF 22 (QB 0016) Lifetime: 25 hours continuous ELECTRICAL OUTPUT FROM INTERNAL GENERATOR: Pink: 45 mv in each 1 / 3-octave White: 45 mv in 250 Hz 1 / 3-octave FREQUENCY RANGE: 10 Hz to 20 khz OUTPUT IMPEDANCE: 50 Ω When the Sound Source, ZI 0055, is fitted to the Intensity Coupler, UA 0914, and driven from an external source the following specifications apply: SENSITIVITY: 15.4 Pa/V (10 Hz to 1 khz) MAXIMUM INPUT VOLTAGE: 70 mv RMS INPUT IMPEDANCE: >18kΩ (f <5 khz) Correction Barometer UZ 0004 PRESSURE RANGE: 650 hpa to 1080 hpa ACCURACY: Better than ±2.0% at 20 C Calibration Tolerance: ±0.25 db Nominal Microphone Spacing: 50 mm Ambient Pressure Coefficient: 1.25 10 4 db/hpa Temperature Coefficient: 0.024 db/ C Humidity coefficient: Negligible SIMULATED PARTICLE VELOCITY LEVEL: 117.7 ±0.6 db re 50 nm s 1 Calibration Tolerance: ±0.3 db Nominal Microphone Spacing: 50 mm Temperature Coefficient: 0.05 db/ C Ambient pressure coefficient: 8.3 10 3 db/hpa Humidity Coefficient: negligible PRESSURE-RESIDUAL INTENSITY INDEX MEASUREMENT USING ZI 0055 (Pink noise with 0 db attenuation. All levels measured in 1 / 3-octaves): PORTS 1 AND 2 (SPL only): 250 Hz: 74 ±2.0 db 20 Hz to 1 khz: ±3.0 db re level at 250 Hz 1.25 khz to 5 khz: ±6.0 db re level at 250 Hz COMPLIANCE WITH STANDARDS: CE-mark indicates compliance with: EMC Directive. PRESSURE-RESIDUAL INTENSITY INDEX OF SOUND FIELD IN UA 0914 MEASURED WITH: 50 mm Nominal Microphone Spacing: >30dB 12 mm Nominal Microphone Spacing: >24dB Dimension and Weight (Case) Height: 280 mm (11 ) Width: 230 mm (9 ) Depth: 63 mm (2.5 ) Weight: 2.3 kg (5.1 lb) Note: All values are typical at 20 C (77 F), unless measurement uncertainty or tolerance field is specified. All uncertainty values are specified at 2σ (i.e. expanded uncertainty using a coverage factor of 2) Signal Levels obtained in Intensity Coupler UA 0914 REFERENCE CONDITIONS: Pressure: 1013 hpa Temperature: 20 C Relative Humidity: 65% CALIBRATION USING TYPE 4228 PORTS 1 AND 2: Sound Pressure Level: 118.0 ±0.4 db re 20 µpa Calibration Tolerance: ±0.2 db Ambient Pressure Coefficient: 8.4 10 3 db/hpa Temperature Coefficient: <±0.002 db/ C Humidity Coefficient: Negligible PORTS 1 or 2, AND 3: Simulated Sound Intensity Level: 117.85 ±0.5 db re 1 pw m 2 Safety EMC Emission EMC Immunity Temperature Humidity EN 61010 1 and IEC 1010 1: Safety requirements for electrical equipment for measurement, control and laboratory use. EN 50081 1: Generic emission standard. Part 1: Residential, commercial and light industry. EN 50081 2: Generic emission standard. Part 2: Industrial environment. CISPR 22: Radio disturbance characteristics of information technology equipment. Class B Limits. FCC Rules, Part 15: Complies with the limits for a Class B digital device. EN 50082 1: Generic immunity standard. Part 1: Residential, commercial and light industry. EN 50082 2: Generic immunity standard. Part 2: Industrial environment. IEC68 2 1 & IEC68 2 2: Environmental Testing. Cold and Dry Heat. Operating Temperature: 10 to +50 C (14 to 122 F) Storage Temperature: 25 to +70 C ( 13 to 158 F) IEC68 2 14: Change of Temperature: 10 to +50 C (2 cycles, 1 C/min.) IEC68 2 3: Damp Heat: 90% RH (non-condensing at 40 C (104 F)) Ordering Information Type 3541 Sound Intensity Calibrator Includes the following accessories: UA 0914: Intensity Coupler Type 4228: Pistonphone ZI 0055: Sound Source UZ 0004: Correction Barometer 2 UA 1314: Two 1 / 4 Microphone Adaptors DB 3111: Intensity Coupler Base-Plate 6 QB 0013: 1.5 V Alkaline Battery IEC Type LR 6 QB 0016: 9 V Alkaline Battery IEC Type 6LF22 2 AO0038: Cable with 10 32 UNF connectors 2 JP 0145: 10 32 UNF to BNC Plug Adaptor UC 5298: Dummy Microphone Microphone Adaptors for Pistonphone: DP 0776: 1 / 2 Adaptor DP 0775: 1 / 4 Adaptor DP 0774: 1 / 8 Adaptor Calibration Charts Brüel&Kjær reserves the right to change specifications and accessories without notice 5

Brüel & Kjær B K WORLD HEADQUARTERS: DK-2850 Naerum Denmark Telephone: +45 45 80 05 00 Fax: +45 45 80 14 05 Internet: http://www.bk.dk e-mail: info@bk.dk Australia (02 ) 9450-2066 Austria 00 43-1-865 74 00 Belgium 016/44 92 25 Brazil (011) 246-8166 Canada: (514) 695-8225 China 10 6841 9625 / 10 6843 7426 Czech Republic 02-67 021100 Finland 90-229 3021 France (01) 69 90 69 00 Germany 0610 3/908-5 Holland (0)30 6039994 Hong Kong 254 8 7486 Hungary (1) 215 83 05 Italy (02) 57 60 4141 Japan 03-3779-8671 Republic of Korea (02) 3473-0605 Norway 66 90 4410 Poland (0-22) 40 93 92 Portugal (1) 47114 53 Singapore (65) 275-8816 Slovak Republic 07-37 6181 Spain (91) 36810 00 Sweden (08) 71127 30 Switzerland 01/94 0 09 09 Taiwan (02) 713 9303 United Kingdom and Ireland (0181) 954-236 6 USA 1-800 - 332-2040 Local representatives and service organisations worldwide BP0703 13 96/03