RP C18 column with feature of a silanol group

Similar documents
Silanol. Groups Liquid Chromatography

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Inertsil ODS-EP Technical Information

HPLC column C18 C8 PFP. SunShell. Core Shell Particle

Method Development Kits

Packings for HPLC. Packings for HPLC

HPLC column. Sunniest. C18, C18-HT, RP-AQUA, C8, PhE, PFP. ChromaNik Technologies Inc.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Shodex TM ODP2 HP series columns

Reversed Phase Solvents

CLIPEUS - A Small Shield for a Big Job

8. Methods in Developing Mobile Phase Condition for C18 Column

C18, C18-WP, HFC18-16, HFC18-30,RP-AQUA, C8, PFP,

Optimisil HPLC & UPLC Column catalogue

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Hypersil BDS Columns TG 01-05

Advantages of polymerbased. an alternative for ODS

Inertsil Technical Library

HPLC Column Classification

InertSustainSwift C8

The Evolving HPLC Column Packings

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Overview Applications of NUCLEODUR HPLC Phases

InertSustainSwift C8

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

penta-hilic UHPLC COLUMNS

Comparison of different aqueous mobile phase HPLC techniques

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Fluophase and Fluofix Columns

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

LC and LC/MS Column Selection Flow Chart

INERTSIL (GL Sciences)

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

ODS-UG,HG,MG,SR columns

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Analysis - HPLC A.136. Primesep 5 µm columns B.136

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

ISOSCELES PELLICULAR CORE

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

penta-hilic UHPLC COLUMNS

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

Comparison Guide to C18 Reversed Phase HPLC Columns

Too Polar for Reversed Phase What Do You Do?

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

ProntoSIL HPLC Columns

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

Looking into the HPLC Column while Running CIP

General Principles of HPLC Method Development

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Reversed Phase Chromatography: Mobile phase Considerations

HPLC Column for Structual Isomers

Technical Guide Thermo Scientific Syncronis HPLC Columns

William E. Barber, Ph.D. Applications Chemist October

Your Reversed Phase Method

The Retention Behavior of Reversed-Phase HPLC Columns with 100% Aqueous Mobile Phase

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

mau 200 ph min

Choosing Columns and Conditions for the Best Peak Shape

Alltech Alltima HP Introduction

A C18 Silica Column With Exceptional Temperature and ph Stability

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

High Performance Liquid Chromatography

High Performance Liquid Chromatography

H P L C C O L U M N S

C18, C18-WP, HFC18-16, HFC18-30,RP-AQUA, C8, C30, PFP, Phenyl, C8-30, C8-30HT, C4-30, HILIC-Amide and 2-EP. Core Shell Particle

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HPLC UHPLC Columns. Dikma Technologies Inc.

Sepax SRT -C, Zenix -C SEC Phases

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

Cellufine Butyl Cellufine Phenyl

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

LC Columns with Liquid Separation Cell Technology

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

State-of-the-art C18 HPLC Columns

Next Generation of Phenyl Columns. Chromatography Products.

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

ACE Ultra Inert Base Deactivated HPLC Columns

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

NUCLEOSHELL core-shell silica for HPLC

Acclaim Mixed-Mode WCX-1

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Solid Phase Extraction Method Development Tips and Tricks

Kromasil Eternity Designed for long life

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

NUCLEODUR (Macherey-Nagel)

Transcription:

RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik

Sunrise C8 Sunrise C8 PLC column Name Stationary phase Carbon content Ligand density Particle size C8 ctadecyl %. µmol/m µm, µm C8 ctacocyl 8%.7 µmol/m µm, µm lica support Surface area: m /g Pore volume:. ml/g Pore diameter: nm End-capping Trimethylsilyl group (TMS) p range of C8 and dc8: p~p8 End-capping type Sunrise series の特徴 C8: A long alkyl chain improves both separation of fat-soluble compounds to compare with C8 phase and an excellent reproducibility in retention under high aqueous conditions. Furthermore, a suitable ligand density of C8 allows to be obtained a shape peak shape even if more than % aqueous mobile phase is used. Different selectivity Separation of Basic compounds Sunrise C8 8 8 retention time / min Suniest PhE Reverse Column size: x. mm 8/=C /mm P.B. p7. Flow rate:. ml/min Temperature: ºC Sample: = uracil = propranolol = toluene = nortriptyline = amitriptyline C N C N C C8: Conventional C8 phase with full end-capping 7 8 retention time / min C N C PhE: (Sunrise PhE has stopped production. Sunniest PhE is recommended as a replacement) Interaction based with p-electron such as p-p interaction p-electron also interacts with a polar site of a compound, so that phenyl phase improves separation of polar compounds. Ethylene chain between silica surface and phenyl group allows a movable sphere of a phenyl group to be wide. A chain with more than three carbons shows more hydrophobic interaction, so that p-electron interaction decreases relatively. Phenethyl (PhE) group is a suitable phenyl phase. Separation of Vitamin E Sunrise C8 Conventional C8, Isomer can be separated by C8 Column size: x. mm 97/=C / Flow rate:. ml/min Temperature: ºC Detection: UV at 9nm Sample: =δ-tocopherol =γ-tocopherol =β-tocopherol =α-tocopherol

Sunrise C8 Sunrise C8 PLC column Comparison of stationary phases Sunrise C8 7% C Sunrise C8 9% C Column size: x. mm / Flow rate:. ml/min Temperature: C Sample: = Methylparaben = Ethylparaben = Benzene = Toluene = Naphthalene = Ethylbenzene SunnistPhE % C Retention increased due to π- π interaction. Sunrise C8-SAC % C Retention increased due π electron interaction between naphthalene and silanol groups. Comparison of separation of α, β - carotene Conventional C8 Column size: x. mm C CN/CCl = 8: Flow rate:. ml/min Temperature: ºC Detection: UV at nm Sample: = α-carotene The mobile phase including chroloform makes alkyl chains brash up because chroloform can enter among alkyl chains. Consequently retention times of C8 became times longer than C8. C C C C C C C C C C Sunrise C8 = β-carotene C C C C C C C C C C

Sunrise C8 Separation of xylene isomers ºC Column: Sunrise C8, µm x. mm C/=7: Flow rate:.7 ml/min Temperature: ºC and ºC Detection: UV@nm Sample: BTEX = Benzene = Toluene C = Ethylbenzene = o-xylene C = m-xylene = p-xylene ºC Sunrise C8 can separate xylene isomers although conventional C8 can t. The lower a temperature, the better a separation of isomers. Separation of ter-phenyl isomers Conventional C8 Column: Conventional C8 x. mm Sunrise C8, µm x. mm Methanol/water=9: Flow rate:. ml / min Temperature: oc Detection: UV@ nm Sample: = -Terphenyl, = m-terphenyl, = p- Terphenyl 7 Sunrise C8 7 8 9

Sunrise C8-SAC lanol Activity Controlled C8 PLC Column New generation reversed-phase utilized silanol groups lanol group and peak tailing It is generally said that residual silanol groups on a stationary phase such as C8 (DS) causes absorption or peak tailing for a sample. Especially silanol groups near a hydrophobic site don t solvate with water completely, so that they show high absorption for basic compounds. Its peak shows terribly tailing. Several end-capping techniques have been developed to solve these problems for many years. st generation nd generation rd generation Bonded type th generation igh carbon and end-capped type th generation ighly endcapped type ybrid type lanol Activity Control Technology Sunniest C8 Sunrise C8 Sunrise C8-SAC Pellicular type lanol activity control technology ChromaNik developed the technique that decreased only silanol groups with high absorption activity to a basic compound and remained effective sailnol groups on the stationary phase. lanol activity control and no end-capping led the existence of silanol groups with high hydration which created a new and unique reversed-phase separation mode including hydrogen bond and ionexchange interaction. Furthermore, silanol activity controlling, then end-capping technique improved a peak shape of a basic compound exceedingly. C lanol groups with high absorption activity lanol Activity Control Technology C lanol activity control Changeover to siloxane bond Feature of Sunrise series Sunrise C8 The st Choice column as a fully end-capped C8 column Full end-capping after silanol activity control Reducing adsorption of a basic compound extremely A good peak shape for a metal cheleting compound Widely available for general reversed-phase separation Sunrise C8-SAC The "nd Choice" column which takes advantage of effective silanol groups interaction Reducing silanol groups with high adsorption activity The new separation mechanism including hydrogen bond and ion-exchange interaction Effective for separation of a basic compound and a polar compound Different selectivity and improvement of separation without changing a mobile phase The elution order of pyridine A) Sunrise C8 (end-capped) C) Sunrise C8-SAC (non end-capped) () B) Conventional no end-capped C8 () retention time / min Column size: x. mm C / =/7 Sample: = uracil () = pyridine = phenol ()

Sunrise C8-SAC lanol Activity Controlled C8 PLC Column Sunrise series create an unique separation Effectiveness of silanol activity control: Comparison between Sunrise C8 and C8-SAC Sunrise C8 is the so-called fully end-capped C8 column. It shows the same separation behavior as a conventional C8 column. n the other hand, Sunrise C8-SAC shows hydrogen bond and ion-exchange interactions based on a residual silanol on the silica support in addition to reversed-phase separation. For example Sunrise C8 column separates a basic compound similarly as a conventional C8, while Comparison of selectivity for basic compounds Sunrise C8-SAC makes retention of a basic compound be large because an ion-exchange interaction works although a non-ionic compound shows the almost same retention on both Sunrise C8 and C8-SAC. Furthermore, Sunrise C8-SAC shows large retention for a polar compound such as caffeine. Comparison of peak shape and retention A) Sunrise C8 p. A) Sunrise C8 Column size: x. mm C CN/mM P = :9 Flow rate:. ml/min Sample: = 8-Quinolinol (xine) = Caffeine B) Sunrise C8-SAC p. B) Sunrise C8-SAC A) Sunrise C8 B) Sunrise C8-SAC 8 Column size: x. mm C CN/mM Phosphate buffer p. or p. = : Flow rate:. ml/min Temperature: ºC N Sample: = Uracil = Propranolol N N C C p. p. 8 8 Comparison of caffeine A) Sunrise C8 B) Sunrise C8- SAC Column size: x. mm C /mm Phosphate buffer p. = :7 Flow rate:. ml/min Temperature: C Sample: = Theobromine = Theophylline = Caffeine = Phenol = Nortriptyline = Amitriptyline = Toluene C N C C N C 7 8 9

Sunrise C8-SAC lanol Activity Controlled C8 PLC Column Multiple mode separation is achieved on Sunrise series lanol groups controlled its activity functions as ion-exchange groups Sunrise C8-SAC is bonded with octadecylsilane on a pure silica gel and controlled its silanol activity without end-capping. Its carbon content is %. Separation of basic compounds with ammonium acetate: Effect of salt concentration(sunrise C8-SAC) mm mm mm mm mm Column size: x. mm C CN / acetate ammonium (p.) = 7: Flow rate:. ml/min Temperature: C Sample: = Uracil = Toluene = Propranolol = Nortriptyline = Amitriptyline 8 8 Separation on Sunrise C8-SAC is done including hydrogen bond and ion-exchange interaction based on silanol groups except for hydrophobic interaction. Control of p and salt concentration of a mobile phase can regulate retention. Relationship between buffer concentration and retention(sunrise C8-SAC) log k....8.... Toluene...... log [Buffer concentration] N (Amitriptyline) Amitriptyline Nortriptyline Propranolol,,, 8,,,, z B z B Vr log k = log[ A] + log[ A] + log + log K z z V z A A A:ion in eluent,b:ion of sample, k:retention of B,K:selection coefficient ZA, ZB:charge,Vr, Vm:resin volume and mobile phase volume in column m A N(Amitriptyline) N [Amitriptyline] B A Chromtograms under different p conditions (Sunrise C8-SAC) p.7 p. under acetic acid solution, p was.7 and there no ammonium ion. A basic compound shows tailing under p.7 (no ammonium ion). N=, Column size: x. mm C CN / mm acetate ammonium = 7: Flow rate:. ml/min Temperature: C Sample: N = Uracil N p. = Toluene C p. = Propranolol C N C p.9 = Nortriptyline = Amitriptyline N C p.8 N=, C N C

Sunrise C8, C8, C8-SAC Sunrise series Analytical and Preparative Columns Inner diameter length Sunrise C8, µm Sunrise C8, µm [mm] [mm] Cat. No. Cat. No.. ST ST 7 ST - ST ST ST7 ST7 ST8 ST8. ST ST ST ST 7 ST - ST ST ST7 ST7 - ST8. - ST78. - ST88 Inner diameter length Sunrise C8, µm Sunrise C8, µm Sunrise C8-SAC, µm Sunrise C8-SAC, µm [mm] [mm] Cat. No. Cat. No. Cat. No. Cat. No.. SB SB SA SA 7 SB - SA - SB SB SA SA SB7 SB7 SA7 SA7. SB SB SA SA SB SB SA SA 7 SB - SA - SB SB SA SA SB7 SB7 SA7 SA7 - SB8 - SA8. - SB78 - SA78. - SB88 - SA88 8