Use of Ultra-High Performance LC-MS for Challenging Assays. David Browne, Laboratory Manager (LC-MS-MS), Covance Laboratories, Harrogate

Similar documents
Quality control analytical methods- Switch from HPLC to UPLC

LC Technical Information

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Successfully Scaling and Transferring HPLC and UPLC Methods

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM

Definitive EtG/EtS LC-MS/MS Analysis:

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

1.7 m Fortis UHPLC Columns

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

UPLC Method Development and Validation

UPLC for Synthetic Peptides: A User`s Perspective

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

+ butanal + 2-picolineborane. + acetic acid. + butanal + 2-picolineborane. + acetic acid

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Implementation of Methods Translation between Liquid Chromatography Instrumentation

Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Part 2. Overview of HPLC Media

1.7µm Fortis UHPLC Columns

2010 Waters Corporation. Xevo TQ-S for Bioanalysis

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput

ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Bringing uhplc Performance to the Separation of Peptides

Automatization for development of HPLC methods

Translational Biomarker Core

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

[S016. CHROMATOGRAPHY]

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

Quantitative Screening of 46 Illicit Drugs in Urine using Exactive Ultrahigh Resolution and Accurate Mass system

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Liquid Chromatography

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Routine MS Detection for USP Chromatographic Methods

How proteins separate on reverse-phase HPLC

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Fast methods for the determination of ibuprofen in drug products

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Basic chromatographic parameters and optimization in LC

LIQUID CHROMATOGRAPHY

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

surpass all possibilities [ Cortecs 2.7 µm columns ]

2007 Waters Corporation. Application of UPLC to Peptide Mapping

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma

DEVELOPMENT AND VALIDATION OF NEW ANALYTICAL METHOD FOR BIOACTIVE COMPOUNDS

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Nexera UC Unified Chromatography

MODERN HPLC FOR PRACTICING SCIENTISTS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

LC-MS compatible Separation of the Fungicide Spiroxamine

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

LECTURE 2. Advanced Separation Science Techniques Present and Future Separation Tools

Validation of ACQUITY UPLC Methods

OUTLINE 18/08/2011 NEW DEVELOPMENTS IN LC/MS/MS FRONT-END AUTOMATION. Expanding role of tandem mass spectrometry in the clinical laboratory

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

ACQUITY UPLC Peptide BEH C 18, 130Å and 300Å Columns

Screening of pesticides in water using SPE on line

LC MS analysis of metabolites. Basis of Chromatography

[ a ppl ic at ion no t e ]

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

High Speed vs. High Resolution Analyses in HPLC: A Critical Performance Comparison of Column Options Using Poppe and Kinetic Plots

A Fast and Efficient Method to Assess 2D-HPLC Column and Method Combinations for Food Metabolomics Studies

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

1.7µm Fortis C18 UHPLC Columns

UPC 2 Strategy for Scaling from Analytical to Preparative SFC Separations

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

penta-hilic UHPLC COLUMNS

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

High Speed 2D-HPLC Through the Use of Ultra-Fast High Temperature HPLC as the Second Dimension

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

State-of-the-art C18 HPLC Columns

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Transcription:

Use of Ultra-High Performance LC-MS for Challenging Assays David Browne, Laboratory Manager (LC-MS-MS), Covance Laboratories, Harrogate

Department of Bioanalytical Services Determination of drug substance and metabolites in biofluids to support toxicokinetic and pharmacokinetic studies.

Theory - The Van Deemter Equation HETP = 2λd p + 2γD m + ωd 2 p v v D Lateral Diffusion m Longitudinal Diffusion Mass transfer HPLC H E T P P re s u re LINEAR VELOCITY

Theory - The Van Deemter Equation HETP = 2λd p + 2γD m + ωd 2 p v v D Lateral Diffusion m Longitudinal Diffusion Mass transfer UPLC H E T P P re s u re LINEAR VELOCITY

Theory - The Van Deemter Equation HETP = 2λd p + 2γD m + ωd 2 p v v D Lateral Diffusion m Longitudinal Diffusion Mass transfer 5 μm spherical particles

Theory - The Van Deemter Equation HETP = 2λd p + 2γD m + ωd 2 p v v D Lateral Diffusion m Longitudinal Diffusion Mass transfer 3 μm spherical particles

Theory - The Van Deemter Equation HETP = 2λd p + 2γD m + ωd 2 p v v D Lateral Diffusion m Longitudinal Diffusion Mass transfer 1.7 μm spherical particles

Efficiency gains with smaller particles System Efficiency and Velocity Smaller particle sizes: maximum resolution at higher linear velocity running at higher than optimal velocity gives minimal loss in resolution Therefore: higher flow rates are possible faster analysis shorter columns same resolution sensitivity is increased as the peak is sharper

Efficiency & Backpressure at constant velocity 500,000 System Efficiency and Backpressure 1.0 μm System Efficiency (Plates/m) 400,000 300,000 200,000 1.4 μm 1.7 μm 3 μm New equipment needed to take advantage of efficiency gains at higher pressure 100,000 5 μm 10 μm 0 0 20,000 40,000 60,000 80,000 100,000 120,000 140,000 Backpressure (psi)

Examples A robust bioanalytical method comprises 3 components Extraction Chromatography Detection Rough rule of thumb: at least 2 of these components must be highly selective. Which of the 3 components can we manipulate to obtain the biggest gains?

First example Endogenous compound Sensitivity required (10pg/mL) Does not give selective MS/MS transition Extraction: protein precipitation followed by selective SPE. Chromatography difficult due to co-extracting isoforms. Poor peak integrity presence of several peaks at the RT of the analyte Only 1 component is highly selective (extraction)

Vitamin Analogue R C H 3 CH 3 OH MS/MS Transition precursor ion (M + NH4)+ product ion loss of (NH3+H2O) non-selective ms/ms transition! HO OH

HPLC YMC ODS 3 µm, 2.1 x 100 mm, 0.3 ml/min

UPLC Waters ACQUITY BEH C18, 1.7 µm, 2.1 x 100 mm, 0.5 ml/min

HPLC vs. UPLC HPLC UPLC

Example 1 (UPLC vs. HPLC) UPLC Relatively high chromatographic resolution High peak purity/integrity Cycle time 7 minutes Same robustness as HPLC Increase in sensitivity x2 Lower injection volume HPLC Relatively low chromatographic resolution Low peak purity/integrity Cycle time 13 minutes Robust

Second example Steroid and prodrug Sensitivity required (100 pg/ml) Does not give selective MS/MS transition Extraction: C18 SPE. Chromatography very long due to isobaric interferences (25 minute cycle time) Only 1 component is highly selective (chromatography)

Steroid and Pro-drug Steroid: [M + Acetate] - OH Pro-drug: [M - H] - R O Isobaric interferences O R R

HPLC Phenomenex Luna C18, 3 µm, 2.0 x 100 mm, 0.2 ml/min

UPLC Waters ACQUITY BEH C18, 1.7 µm, 2.1 x 100 mm, 0.4 ml/min

HPLC vs. UPLC 100 pg/ml spiked extract injected on the two different systems * HPLC * UPLC

Example 2 (UPLC vs. HPLC) UPLC High chromatographic resolution Cycle time 6.5 minutes Same robustness as HPLC Increase in sensitivity x 4 HPLC High chromatographic resolution cycle time 25 minutes Robust

Third example Peptide - MW ~1850 Sensitivity required (10ng/mL) Does not give selective MS/MS transition Extraction: protein precipitation Chromatography difficult due to similar co-extracting analogues. Poor peak integrity presence of several peaks at the RT of the analyte No component is selective

Peptide MS/MS Transition precursor ion [M + 3H] 3+ product ion loss of (H 2 O) non-selective ms/ms transition!

HPLC Penomenex Jupiter C18 5 µm, 2.1 x 50 mm, 0.3 ml/min

UPLC Waters ACQUITY BEH C18, 1.7 µm, 2.1 x 50 mm, 0.5 ml/min

HPLC vs. UPLC HPLC UPLC

Example 3 (UPLC vs. HPLC) UPLC Relatively high chromatographic resolution High peak purity/integrity Cycle time 5 minutes Same robustness as HPLC Increase in sensitivity x5 Lower injection volume HPLC Relatively low chromatographic resolution Low peak purity/integrity Cycle time 5.5 minutes Robust

General Conclusions: UPLC vs. HPLC Sensitivity? Selectivity? Analysis time? Robustness? Ease of use? Cost? Increase Large increase Reduced Comparable Simple Conventional HPLC +~20% Is this the way forward in LC/MS-MS? Yes!

UPLC & API 4000 in combination UPLC Relatively high flow rates to maximise the gains of UHPLC For a 50 x 2.1 mm column, optimum flow is 0.5 to 1 ml/min API 4000 Works with relatively high flow rates, typically to 1.5 ml/min No real advantage in running higher flow rates Higher solvent usage UPLC/MS-MS A real advantage in running at higher flow rates, facilitated by the solvent capacity of the API 4000, and... No increase in solvent consumption due to shorter run times

Robustness Vitamin biomarker assay: ran 84 batches (approx. 100 extracted samples each) blocked columns - fixed by using a frit chromatography deteriorating (3 batches/column) PEEK needle bending - metal available shortly gradient from 50-98% organic Rt. stable

Disadvantages 50 µl maximum loop size 65 C upper limit on column oven PEEK injection needle Control through MassLynx or Empower only PEEK Needle

Jasco X-LC System capable of up to 15,000 psi Columns available down to 1.5 µm (although can t be used at these pressures!) Same Rheodyne valve as Waters Can also be used to retrofit CTC autosamplers

Agilent 1200 System capable of up to 8700 psi Removed > 350 µl dead volume Rapid Resolution HT Columns C18 and C8 (1.8µm) 4.6, 3.0 or 2.1 x 30 or 50 mm Systems available from Feb 2006

Columns - Alltech, Phenomenex and Thermo Alltech (1.5µm) HILIC, C18 and C8 2.1 or 4.6 x 10 or 20 mm 7 x 33 or 53 mm Hypersil Gold (1.9µm) C18 only 2.1 x 20, 30 or 50 mm Phenomenex (2.0µm) Synergy columns: 2.0, 4.0 and 4.6 x 10, 20, 30 or 50 mm

Towards a Different Future We may never know what motivated our fish ancestors to come out of the water. David Attenborough - Naturalist from Why Men Don t Listen and Women Can t Read Maps Allan and Barbara Pease 1999

Summary UPLC gives you: Improved selectivity Shorter runtime Greater sensitivity You just need the equipment to run it!

Acknowledgements Mohammed Abrar Sunetha Diaram Julian Potter Phill Turpin David Bakes

Questions?