General YMC Hydrosphere C Ordering Information

Similar documents
General Hydrosphere C Ordering Information

State-of-the-art C18 HPLC Columns

InertSustainSwift C8

InertSustainSwift C8

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

for Acclaim Mixed-Mode HILIC-1 Column

Inertsil Technical Library

Method Development Kits

Shodex TM ODP2 HP series columns

State - of - the -art C18 HPLC Columns

Packings for HPLC. Packings for HPLC

Optimisil HPLC & UPLC Column catalogue

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Acclaim Mixed-Mode WCX-1

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Alltech Alltima HP Introduction

Inertsil ODS-EP Technical Information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

LC and LC/MS Column Selection Flow Chart

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

ACE Ultra Inert Base Deactivated HPLC Columns

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

8. Methods in Developing Mobile Phase Condition for C18 Column

Optical Isomer Separation Columns and Packing Materials

The Evolving HPLC Column Packings

William E. Barber, Ph.D. Applications Chemist October

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Reversed Phase Solvents

for Acclaim Mixed-Mode WCX-1

penta-hilic UHPLC COLUMNS

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Overview Applications of NUCLEODUR HPLC Phases

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

H P L C C O L U M N S

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Choosing Columns and Conditions for the Best Peak Shape

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Advantages of polymerbased. an alternative for ODS

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Column handling. Information. 1 Introduction 2 Shipping solvent. 3 Mobile phase. 4 Mobile phase replacement and column cleaning (general methods)

Stationary phases for prep LC

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

INERTSIL (GL Sciences)

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Hypersil BDS Columns TG 01-05

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Technical Information

for Acclaim Trinity TM P1

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Too Polar for Reversed Phase What Do You Do?

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Part 2. Overview of HPLC Media

Guide to Choosing and Using Polymer Reversed Phase Columns!

HPLC UHPLC Columns. Dikma Technologies Inc.

CLIPEUS - A Small Shield for a Big Job

High Performance Liquid Chromatography

Technical Guide Thermo Scientific Syncronis HPLC Columns

Silanol. Groups Liquid Chromatography


ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

RP C18 column with feature of a silanol group

Epic Aromatic Selectivity

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Sample Preparation TLC Plates

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

YMC-Triart Prep. Robust Improved particle properties result in better chromatographic performance

Bringing uhplc Performance to the Separation of Peptides

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

penta-hilic UHPLC COLUMNS

LC Technical Information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Acclaim Mixed-Mode WAX-1 Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Gemini-NX Performance paired with Axia Technology

6 Optical Isomer Separation Columns

ProPac WCX-10 Columns

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

1.7 m Fortis UHPLC Columns

Comparison of different aqueous mobile phase HPLC techniques

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

[ CARE AND USE MANUAL ]

It s hot! ZIC -chilic

New Product Update. HPLC Columns

Chemistry Instrumental Analysis Lecture 28. Chem 4631

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

HPLC Columns YMC RP-Classics. Introduction. Contents. 136 Reversed Phase. YMC-Pack ODS-AQ YMC-Pack ODS-A

HPLC column C18 C8 PFP. SunShell. Core Shell Particle

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Transcription:

5

YMC ProFamily 5 YMC ProFamily Contents General... 54-6 YMC-Pack Pro C8... 6-65 YMC-Pack Pro C8... 66-67 YMC-Pack Pro C4... 68-69 YMC-Pack Pro C8 RS... 70-7 YMC Hydrosphere C8... 74-77 Ordering Information... 78-8 Introduction YMC ProFamily One of the main challenges in RP-HPLC is the quantitation of ionisable compounds including drugs, degradation products, etc. For this purpose symmetrical, sharp peaks are required to provide highest resolution and reliable integration. The stationary phases of the YMC ProFamily fulfil these demands making them an excellent choice for the pharmaceutical and biotechnology industries. This product line consists of the three C8-phases: YMC-Pack Pro C8 RS, YMC-Pack Pro C8 and Hydrosphere C8 together with the C8- and C4-phase: YMC-Pack Pro C8 and YMC-Pack Pro C4.

54 YMC ProFamily YMC ProFamily -0 - YMC-Pack ProFamily based on ultra high purity silica - Hydrosphere C8 for stability in aqueous mobile phases - every packed column supplied with: lot certificate test chromatogram AS OS BS RS HS Pro C8 Pro C8 Pro C4 Pro C8 RS Hydrosphere C8 Particle size / µm ; 5 ; 5 ; 5 ; 5 ; 5 Pore size / nm 8 Surface area / m g - 40 40 40 50 40 Carbon content / % 7 8 ph range.0-8.0.0-7.5.0-7.5.0-0.0.0-8.0 Metal content (Randomly selected lots) Al / ppm 0. 0. 0.6 0. 0.7 Fe / ppm.8.5.9 0.. Na / ppm 0..4.0. 0.7 Ti / ppm 0. 0. 0. 0. 0. see pages 6-65 see pages 66-67 see pages 68-69 see pages 70-7 see pages 74-77 Properties Strict quality control is enforced during the manufacturing of the underlying silica, bonding of the stationary phase, end capping and column packing operations to supply high performance columns of high reproducible quality over a long period of time. Lot-to-lot reproducibility of YMC-Pack Pro C8. Uracil. 4-n-Butoxybenzoic acid. Ethyl benzene 4. n-propyl benzene HPLC-Test A k (Ethyl benzene)/ k (n-propyl benzene) k (4-n-Butoxybenzoic adic)/ k (n-propyl benzene) Specification 0.69-0.65 0.8-0.6 Column Kits MD VAL R&D PS pages - 4 Lot C Lot B Lot A 0 5 0 5 min HPLC Test A Column: 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 -H PO 4 (ph.5) / acetonitrile (40/60,v/v) Flow rate:.0 ml/min Detection: UV at 54nm Temperature: 7 C

YMC ProFamily 55 YMC ProFamily Underlying silica gel support The physical properties of silica gel have a great effect on the selectivity and performance of the bonded packing. For the purpose of supplying columns of stable quality, the physical properties of silica gel used for packing such as particle size, pore size, specific surface area, pore volume and amount of metal contamination have to be strictly controlled. Physical properties (Pro C8, 5 µm, nm) Silica Support Material (5 µm, nm) Particle size Consecutive Lot Number Pore size Specific surface area Consecutive Lot Number Consecutive Lot Number Pore volume Amount of metal content Consecutive Lot Number Consecutive Lot Number

56 YMC ProFamily YMC ProFamily Packing material Excellent reproducibility of the Pro C8 is shown not only in the separation of hydrophobic compounds but also in that of hydrophilic, basic, and acidic compounds. Pro C8 5 µm, Reproducibility between batches Percent Carbon Content Consecutive Lot Number Hydrophobicity Acidic compounds Consecutive Lot Number Consecutive Lot Number Hydrogen bonding ability Basic compounds Consecutive Lot Number Consecutive Lot Number

YMC ProFamily 57 Individual Column Test To give our customers an insight into the strict criteria with regard to the silica base, the bonded final product and the reproducible chromatographic behaviour, each column of the ProFamily is supplied with a lot inspection report and an individual column test chromatogram. The first report illustrates the narrow window for physical parameters such as particle size distribution or surface area and the reproducibility of chemical properties. The test chromatogram illustrates the efficiency of the column with a guaranteed minimum performance of 00,000 theoretical plates for 50 and 50 x 4.6 mm i.d. and an asymmetry of 0.90 to.5 (at 0% peak height for 5 µm particle size). Individual Lot Test Indicates the efficiency of the column retention characteristics and symmetry of the test peaks

58 YMC ProFamily YMC ProFamily Comparison of separative selectivity The selectivity characteristics of each column are shown using hydrophobicity and hydrogen-bonding ability as indicators. The ProFamily series of ODS phases is designed to make Hydrosphere C8 and Pro C8 RS have contrasting separation characteristics, with standard Pro C8 in between. Also, Pro C8 and C4 have different selectivity from the ODS phases. By choosing one from these 5 types of columns, one can easily optimise the separation of polar and non-polar compounds. 0.8 Hydrophobicity: low Hydrogen-bonding capacity a (Caffeine / Benzene) 0.6 0.4 0. 0.0 0.08 Hydrogen-bonding capacity: high Hydrophobicity: medium Hydrogen-bonding capacity: medium Hydrophobicity: high Hydrogen-bonding capacity: low 0.06 0.04 4 6 8 0 4 Hydrophobicity k (Amylbenzene) Source: Courtesy of YMC Co., Ltd. Durability for repetitive analysis The long-term stability of a Pro C8 ( µm) short column used in repeated analysis is shown below. There is no change found in the separation of all compounds after 5000 injections (8 hours/day for 5 month) during gradient analysis. Great durability!

Hydrophobicity and steric selectivity YMC ProFamily 59 YMC ProFamily This comparison shows the different properties of the ProFamily members giving a good indication on their potential for method development. The compounds. uracil (dead volume marker). n-butylbenzene. o-terphenyl 4. n-amylbenzene and 5. triphenylene are used to determine the hydrophobicity (. and 4.) and the steric selectivity (. and. 5.) of each ProFamily member under unbuffered chromatographic conditions. YMC-Pack Pro C4 5 YMC-Pack Pro C4 YMC-Pack Pro C8 YMC-Pack Pro C8 5 4 5 4 4 0 5 0 5 0 min 0 5 0 5 0 min 0 5 0 5 min balanced hydrogen bonding, capacity and hydrophobicity lower hydrophobicity lowest hydrophobicity YMC-Pack Pro C8 RS Hydrosphere C8 5 4 5 4 0 5 0 5 0 5 min 0 5 0 5 0 min highest carbon load high polar recognition Column: 50 x 4.6 mm i.d. Eluent: methanol / water (80/0) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm. Uracil. n-butylbenzene. o-terphenyl 4. n-amylbenzene 5. Triphenylene The whole ProFamily covers a large area of hydrophobicity and steric selectivity, as presented in this comparison, which offers the opportunity to accomplish optimisation of chromatographic methods even for complicated separation problems. For more applications please refer to our Application Data Collections or contact us directly. Source: Courtesy of YMC Co., Ltd.

60 YMC ProFamily YMC ProFamily Hydrogen bonding capacity Hydrogen bonding capacity is evaluated by examining the relative retention coefficient as a (caffeine / benzene). Among the Pro series both Hydrosphere C8 with low density of C8, and Pro C4 with short alkyl chain have high hydrogen-bonding capacity. Benzene with non-polar groups is retained according to hydrophobicity of the packing, while retention of caffeine and phenol (hydrophilic compounds), is greatly affected by hydrogen-bonding capacity, and these packing have similar retention time, but show different selectivity. Hydrogen bonding capacity* Column: 50 x 4.6 mm i.d. Eluent: methanol / water (0/70) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm

YMC ProFamily 6 YMC ProFamily Acidic and basic compounds The chromatogram below show the separation of some food additives. Dehydroacetic acid, a compound that can exhibit peak tailing on competitive columns shows excellent peak shape on ProFamily columns. Acidic compounds* Column: 50 x 4.6 mm i.d. Eluent: 0 mm CH COONa-CH COOH (ph 4.4) / acetonitrile (80/0) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 0 nm. p-hydroxyacetophenone (I.S.). Sorbic acid. Dehydroacetic acid Basic compounds* Column: 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 -K HPO 4 (ph 6.9) / methanol (0/70) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm * Source: Courtesy of YMC Co., Ltd.

6 YMC ProFamily YMC-Pack Pro C8 AS USP L - specifically designed for pharmaceutical and biotechnical R&D - extreme narrow specifications - high lot-to-lot reproducibility - high column-to-column reproducibility - ideal for basic, acidic and polar compounds YMC-Pack Pro C8 Specification Particle size / µm *; *; 5 Pore size / nm Surface area / m g - 40 Carbon content / % 7 Recommended ph range.0-8.0 General * please be referred to page 5 ff for Ultra Fast LC and Fast LC Columns YMC-Pack Pro C8 has proven to be one of the first choices for a wide range of HPLC applications in pharmaceutical and biotechnological research and production, where efficiency and reliability are highly appreciated. The main reasons for this success are, besides the very good performance in HPLC separations, the high lot-to-lot and column-to-column reproducibility which are essential for chromatography in general. The figure on the right demonstrates the high lot-to-lot reproducibility for three lots selected at random. The stringent specifications applied as HPLC Test A, and the actual results obtained from the particular lot, are displayed on each lot inspection report, which is supplied with each individual column. The retention of compounds ethylbenzene and butoxybenzoic acid relative to propylbenzene is used to monitor the hydrophobicity of each individual lot. YMC-Pack Pro C8 is also available in preparative particle sizes. Column Kits MD VAL R&D PS pages -

Properties YMC ProFamily 6 YMC-Pack Pro C8 YMC-Pack Pro C8 is based on an ultra pure silica support, which is used for the whole ProFamily. Due to a proprietary endcapping process especially designed for this type of silica, YMC-Pack Pro C8 is perfectly suitable for the separation of acidic and basic molecules. The inertness of the silica makes it an excellent choice for the analysis of drugs or metabolites, compounds that are susceptible to polar interactions with residual silanol groups and metal impurities as demonstrated in the following comparison. The extreme basic substances are selected to prove the very good performance of YMC-Pack Pro C8 in regard to their separation and the peak performance that cannot be achieved with classical materials. Basic compounds YMC-Pack ODS-A YMC-Pack Pro C8 Great peak shape Tricyclic antidepressants Column: YMC-Pack Pro C8 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: 0 mm potassium phosphate buffer (ph 6.9) / methanol (5/75) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm

64 YMC ProFamily YMC-Pack Pro C8 LC-MS Application An additional benefit of this phase is the possibility to replace additives, such as phosphate buffers, by volatile acids or bases which are required for LC-MS detection, where the eluent has to be vaporized in the interface. The two figures below demonstrate the ease of transfer of a standard HPLC method into an LC-MS compatible HPLC method without the loss of performance or any changes in the separation itself. Even the request for fast, short and narrow LC-MS columns can be fulfilled with YMC-Pack Pro C8, which gives a wide range of opportunities for LC-MS method development. LC-MS method transfer on YMC-Pack Pro C8 0 mm Phosphate Buffer % Acetic Acid Column: YMC-Pack Pro C8 (5 µm, nm) 50 x.0 mm i.d. Eluent: 0 mm NH 4 H PO 4 -H PO 4 (ph.) or % acetic acid / methanol (60/40) Flow rate: 0. ml/min Temperature: 7 C Pressure:.0 MPa Detection: UV at 80 nm, 0.6 AUFS Injection: µl (0.05-0. mg/ml) Fast LC-MS separations Baseline separation of compounds with different polarity <5 minutes!. Toluene. Amitriptyline HCl. Progesterone 4. Propylbenzene 5. Acenaphthene 4 5 0 0 0 0 min Column: YMC-Pack Pro C8 ( µm, nm) 50 x.0 mm i.d. Eluent: 0 mm CH COONH 4 / methanol (45/55) Flow rate: 0. ml/min Temperature: 7 C Detection: UV at 54 nm Column: YMC-Pack Pro C8 ( µm, nm) 75 x.0 mm i.d. Eluent: methanol / water / TFA (5/95/0.5) Flow: 0. ml/min Detection: UV at 80 nm, 0.6 AUFS Temperature: 0 ºC Injection: µl (0. 0.5 mg/ml)

YMC ProFamily 65 YMC-Pack Pro C8 Application This small collection of applications can only give a brief insight into the multiple applications for Pro C8. Tetracycline antibiotics Antiepileptics. Ethosuximide. Primidone. Phenobarbital sodium salt 4. Phenytoin 5. Carbamazepine 0 0 min Column: YMC-Pack Pro C8 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: acetonitrile / 0 mm oxalic acid (0/90) Flow:.0 ml/min Detection: UV at 80 nm, 0. AUFS Temperature: 7 ºC Injection: 6 µl (0. mg/ml) Column: YMC-Pack Pro C8 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: 50 mm NH 4 H PO 4 -(NH 4 ) HPO 4 (ph 6.7) / methanol (50/50) Flow: 0.7 ml/min Detection: UV at 5 nm, 0. AUFS Temperature: 0 ºC Injection: 8 µl (0.05 0.7 mg/ml) Flavonoids Cardiac glycosides. Luteolin. Apigenin. Chrysoeriol 4. Baicalein 5. Chrysin 6. Acacetin Column: YMC-Pack Pro C8 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: acetonitrile / 0 mm H PO 4 (5/65) Flow:.0 ml/min Detection: UV at 80 nm, 0. AUFS Temperature: 7 ºC Injection: 5 µl (0.05 mg/ml) Column: YMC-Pack Pro C8 (5 µm, nm) 75 x 4.6 mm i.d. Eluent: acetonitrile / water (0/90) Flow:.0 ml/min Detection: UV at 0 nm, 0.6 AUFS Temperature: 7 ºC Injection: 5 µl (0., 0.4 mg/ml) For more applications please refer to our Application Data Collections or contact us directly. Column care YMC Pack Pro C8 is stable towards hydrolysis between ph.0-8.0. Remove acid and buffer salts before storage. Store the column in methanol / water = 70/0. For detailed information please refer to the Column Care and Use Instructions which are shipped with each analytical column.

66 YMC ProFamily YMC-Pack Pro C8 OS USP L7 - extremely broad selectivity pattern - good alternative to C8-phases - suitable for all types of organic molecules, especially basic pharmaceuticals YMC-Pack Pro C8 Specification Particle size / µm ; 5 Pore size / nm Surface area / m g - 40 Carbon content / % Recommended ph range.0-7.5 General Within the ProFamily, the YMC-Pack Pro C8 provides an additional, less hydrophobic stationary phase for all types of compounds, but especially for basic and metal chelating substances. For many applications regarding the separation of peptides, nucleic acids and similar compounds with LC-MS detection, conventional C8-stationary phases require ion pair reagents and ion-suppression to obtain satisfactory separation and low detection limits. In contrast, Pro C8 with its ultra pure silica allows the analysis without these modifiers but still generates excellent chromatograms. In addition to the reduced hydrophobicity of YMC-Pack Pro C8 compared with YMC-Pack Pro C8, the different steric selectivity offers new possibilities in method optimisation as demonstrated in the figure below: Steric selectivity YMC-Pack Pro C8 vs. YMC-Pack Pro C8 The reversed elution order of triphenylene and o-terphenyl for the shorter C8 chains of YMC-Pack Pro C8 illustrates the different steric recognition for steric-demanding substances. Pro C8 Pro C8. Uracil. Triphenylene. o-terphenyl MD VAL R&D PS Column Kits pages - Column: 50 x 4.6 mm i.d. Eluent: methanol / water (80/0) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm

Peak performance of YMC-Pack Pro C8 for basic substances* YMC ProFamily 67 YMC-Pack Pro C8 YMC-Pack Pro C8 is a member of the ProFamily and as a result gives excellent peak shapes even for basic substances, due to its low metal content and the endcapping procedure, which is identical to that used for YMC-Pack Pro C8. This shall be demonstrated in the comparison below where YMC-Pack Pro C8 outperforms competitive state of the art products.. Butyl p-hydrosybenzoate (I.S.). Chlorpheniramine maleate. Diphenhydramine hydrochloride Inertsil C8- Waters Symmetry C8 YMC-Pack Pro C8 Histamine antagonists Column: 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 -K HPO 4 (ph 6.9) / methanol (5/65) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 60 nm, 0.6 AUFS * By courtesy of YMC Co., Ltd. No need for ion pair reagents Good peak performance for acidic and basic compounds. Theophylline (IS). Phenol. Benzoic acid 4. Salicylic acid. Uracil. Procainamide. N-Acetylprocainamide 4. Phenol Disinfectants Column: YMC-Pack Pro C8 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: acetonitrile / 0 mm H PO 4 (0/80) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 70 nm, 0. AUFS Basic compounds Column: YMC-Pack Pro C8 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 -K HPO 4 (ph 6.9) / acetonitrile (90/0) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm, 0. AUFS For more applications please refer to our Application Data Collections or contact us directly. Column care YMC-Pack Pro C8 is stable towards hydrolysis between ph.0-7.5. Remove acid and buffer salts before storage. Store the column in methanol / water = 70/0. For detailed information please refer to the Column Care and Use Instructions which are shipped with each analytical column.

68 YMC ProFamily YMC-Pack Pro C4 BS L6 USP - proprietary endcapping in order to minimize the effect of residual silanols - for polar organic molecules, especially basic pharmaceuticals and peptides - ideal for fast chromatography YMC-Pack Pro C4 Specification Particle size / µm ; 5 Pore size / nm Surface area / m g - 40 Carbon content / % 8 Recommended ph range.0-7.5 General More than 80% of the RP-HPLC analyses are accomplished on octyl- or octadecyl-phases. Because of this overwhelming majority, many chromatographers neglect other selectivities that might be better suited to their separation, such as butyl phases. With Pro C4, YMC offers a stationary phase based on the well-known ultra pure silica of the ProFamily. Compared to a C8-phase with the same eluent, this less hydrophobic material gives shorter retention times for non-polar compounds while the retention time of polar analytes are virtually unaffected. This makes the Pro C4 an interesting alternative especially when short analysis times are required. For this reason, mixtures with a wide range of component polarity are best analysed by short chains, such as YMC-Pack Pro C4. Within the ProFamily, YMC-Pack Pro C4 is the selectivity of choice to reduce time of analysis in combination with the given advantages of the ProFamily, namely the high purity silica support and the low metal content, which result in excellent peak performance as below. Efficient separation of pharmaceutical drugs Fast separation of nucleic acid bases : Phenytoin : Propranolol HCI : Quinidine 4: Lidocaine 5: Diltiazem HCI 6: Verapamil HCI 7: Nicardipine HCI : Cytosine : Uracil : Guanine 4: Thymine 5: Adenine MD VAL R&D PS Column Kits pages - Antiarrhythmic drugs Column: YMC-Pack Pro C4 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 -K HPO 4 (ph 6.9) / methanol (40/60) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 0 nm Nucleic acid bases Column: 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm

YMC ProFamily 69 YMC-Pack Pro C4 The comparison shown below demonstrates that YMC-Pack Pro C4 is the column of choice when fast HPLC is required. There is almost no difference in retention times for the first three compounds whilst Nicardipine HCl elutes faster on YMC- Pack Pro C4 due to its lower polarity. Optimisation of separation using Pro C8 and Pro C4 Column: Eluent: Flow rate: Temperature: Detection: 50 x 4.6 mm i.d. 0 mm KH PO 4 -K HPO 4 (ph 6.9) / methanol.0 ml/min 7 C UV at 0 nm For more applications please refer to our Application Data Collections or contact us directly. Column care YMC-Pack Pro C4 is stable towards hydrolysis between ph.0-7.5. Remove acid and buffer salts before storage. Store the column in methanol / water = 70/0. Clogged inlet frits often can be cleaned by changing the flow direction or replacement. For detailed information please refer to the Column Care and Use Instructions, which are shipped with each analytical column.

70 YMC ProFamily YMC-Pack Pro C8 RS RS USP L - strongly hydrophobic due to carbon content of % - exhibits extraordinary steric selectivity - extended ph and temperature stability - for the separation of hydrophobic, acidic and basic molecules -0 YMC-Pack Pro C8 RS Specification Particle size / µm ; 5 Pore size / nm 8 Surface area / m g - 50 Carbon content / % Recommended ph range.0-0.0* * it is recommended to use at least 0% organic solvent composition near the ph limits and over 50% at ph values above ph 9.0 to perserve column lifetimes General YMC-Pack Pro C8 RS is the latest ProFamily member designed to provide a complementing selectivity pattern resulting from a high carbon load of % and a broader ph stability range. For the separation of large non-polar molecules, highly hydrophobic stationary phases are required. In many cases, it is only with this kind of columns that the chromatographer is able to separate positional isomers that are often by-products in pharmaceutical and other industrial manufacturing processes. YMC-Pack Pro C8 RS fulfils these demands and, thus additionally gives further opportunities in method development due to its extended ph stability. MD VAL R&D PS Column Kits pages - Properties The relatively high carbon load of YMC- Pack Pro C8 RS with % amplifies the selectivity s ability to discriminate between closely related compounds such as positional or steric isomers. A good system to test this steric selectivity is a mixture of o-, m- and p-terphenyl separated under methanol/water conditions. These three compounds differ only in their three-dimensional structure and not in their hydrophobicity or polarity. YMC-Pack Pro C8 RS recognizes even slight steric differences as shown in the chromatogram on the right, whilst a more conventional carbon load (5%) C8 chemistry does not. Steric selectivity*, Inertsil ODS-V... o-terphenyl m-terphenyl p-terphenyl Pro C8 RS 0 0 0 min 0 0 0 min Column: 50 x 4.6 mm i.d. Eluent: methanol / water (85/5) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm

YMC ProFamily 7 YMC-Pack Pro C8 RS For the analysis of ionisable compounds with reversed phase HPLC, it is recommended to adjust the ph of the mobile phase to a value which is two units higher or lower than the pk value of the individual analytes to insure a complete protonation or deprotonation of acids or bases. This guarantees that poor peak symmetry is not based on interactions between e.g. protonated and unprotonated forms of a base. YMC-Pack Pro C8 RS exhibits an extended ph-stability from ph to 0. Its long-term stability at ph and at ph0, respectively, has been tested under very harsh conditions as shown below. Stability under acidic conditions* ph The hydrophobicity of Pro C8 RS is hardly changed under the harsh condition (ph:, temp.: 70 C). Retention of Butyl benzene (%) Pro C8 RS Conventional ODS monomeric ODS Note: When assessing ph stability data, please take care to certify that complete chromatographic conditions are presented. Basic eluents may significantly affect silicas and traditional bonding chemistries. Therefore, stability data should be considered only after verifying that the buffer system used maintains the selected ph during preparation and use. Furthermore, it must be verified that the eluent is not recycled, since the active basic sites may equilibrate to a saturation level with time, resulting in no further interactions taking place. Consequently, only continuous flow of fresh and thoroughly buffered eluent will provide accurate and meaningful performance data. Stability under basic conditions* 0 Change of number of theoretical plates of Methyl benzoate in % 00 80 60 40 0 ph 0 Full stability for month one shift operation! 0 00 00 00 400 500 600 700 h For ph 0, a borate buffer system (0 mm H BO -NaOH (ph 9.8) / methanol 50/50 at 0 C) was selected to be continuously pumped through the column, while checking the number of theoretical plates for methyl benzoate every 50 hours. * By courtesy YMC Co., Ltd.

7 YMC ProFamily YMC-Pack Pro C8 RS The advantages of this operating stability of YMC-Pack Pro C8 RS under harsh ph conditions can be demonstrated with one example. In this case, the separation of erythromycin is optimised with regards to ph, buffer concentration and temperature. The stepwise enhancement of all three parameters shows a stepwise increase of the number of theoretical plates for erythromycin, while naphthalene is used as an internal standard. Finally, a ph of 8.5 at 45 C and 50 mm buffer concentration appears to the best conditions for this separation in terms of producing an efficient peak performance for erythromycin. Method optimization ph 7 ph 7.5 ph 8 ph 8.5.. H C HO O CH OH H C OH H C H 5 C O CH O H N OH H O O OCH H C CH H O OH H C H H O H H Erythromycin CH CH CH Naphthalene(I.S.) 0 0 0 min 0 0 0 min 0 0 0 min 0 0 0 min k'.4 N 600 k' 4.5 N 700 k' 6.50 N 00 k' 7.48 N 00 0mM 7 C 50mM 7 C 50mM 45 C. H C O CH HO OH OH CH HC CH H H N C O CH H 5C O OH H O O OCH H C CH H O OH H C H H O Erythromycin H H CH k' 7.48 N 00 k' 7. N 800 k' 8.8 N 500. Naphthalene(I.S.) 0 0 0 min 0 0 0 min 0 0 0 min Column: YMC-Pack Pro C8 RS (5 µm, 8 nm) 50 x 4.6 mm i.d. Eluent: potassium phosphate buffer (ph 8.5) / acetronitrile (50/50) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 0 nm YMC-Pack Pro C8 RS: Ideal for the separation of steric demanding compounds and/or for use under broader ph conditions!

Analytical YMC ProFamily Phases 7 YMC-Pack Pro C8 RS Applications The specific properties of YMC-Pack Pro C8 RS make it an excellent choice for the separation of non-polar structurally related analytes. The extended resistance towards acidic and basic conditions not only widens the possibilities in method development but also provides further selectivities for demanding separations such as LC-MS or combinatorial chemistry of: positional isomers, large hydrophobic molecules, basic and acidic compounds, peptides Separation of peptides under LC-MS compatible conditions Separation of acidic and basic drugs under LC-MS compatible conditions 5 4 6. [Arg 8 ]-Vasopressin. Oxytocin. Bradykinin 4. Angiotensin II 5. Leu-Enkephalin 6. Angiotensin I. Flurbiprofen. Methyl benzoate. Lidocaine 4. Diltiazem HCl 5. Verapamil HCl 4 5 0 5 0 5 min Column: YMC-Pack Pro C8 RS (5 µm, 8 nm) 50 x 4.6 mm i.d. Eluent: A: water / TFA (00/0.) B: acetonitrile / TFA (00/0.) Gradient: 5-5% B (0-5 min) Flow:.0 ml/min Detection: UV, 0 nm, 0. AUFS Temperature: 7 ºC Injection: 0 µl (0.05 mg/ml) 0 0 0 0 min Column: YMC-Pack Pro C8 RS (5 µm, 8 nm) 50 x 4.6 mm i.d. Eluent: 0 mm CH COONH 4 -NH (ph 8.9) / methanol (5/65) Flow:.0 ml/min Detection: UV, 0 nm, 0.64 AUFS Temperature: 0 ºC Injection: 0 µl (0. mg/ml, 0.06 µl/ml) Food preservatives. COOH. CH CH CHCH CHCOOH Sorbic acid Benzoic acid. H C O O COCH O Dehydroacetic acid Chlorophenol isomers. o-chlorophenol.. OH OH OH Cl Cl p-chlorophenol Cl m-chlorophenol Nicardipine hydrochloride H C H COOC N degradants CH CH COOCH CH N CH HCl NO Nicardipine HCl Degradation product 0 5 0 5 min Column: YMC-Pack Pro C8 RS (5 µm, 8 nm) 50 x 4.6 mm i.d. Eluent: 0 mm CH COONa - CH COOH (ph 4.) / acetonitrile (80/0) Flow:.0 ml/min Detection: UV at 0 nm, 0.6 AUFS Temperature: 7 ºC Injection: 0 µl (0.0 mg/ml) 0 0 0 min Column: YMC-Pack Pro C8 RS (5 µm, 8 nm) 50 x 4.6 mm i.d. Eluent: acetonitrile / water / acetic acid (0/70/) Flow:.0 ml/min Detection: UV at 0 nm, 0. AUFS Temperature: 7 ºC Injection: 0 µl (0. - 0. mg/ml) 0 0 0 0 40 min Column: YMC-Pack Pro C8 RS (5 µm, 8 nm) 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 -K HPO 4 (ph 6.9) / methanol (5/75) Flow:.0 ml/min Detection: UV at 54 nm, 0. AUFS Temperature: 7 ºC Injection: 0 µl For more applications please refer to our Application Data Collections or contact us directly.

74 YMC ProFamily Hydrosphere C8 HS USP L - stable under the use of 00% aqueous eluent - hydrophilic C8 surface for enhanced polar recognition - no need for ion pair reagents - based on highly inert, ultrapure, ph neutral silica - specifically designed for pharmaceutical and biotechnology R&D Hydrosphere C8 Specification Particle size / µm *; *; 5 Pore size / nm Surface area / m g - 40 Carbon content / % Recommended ph range.0-8.0 General * please be referred to page 5 ff for Ultra Fast LC and Fast LC Columns The separation of polar compounds in many cases requires highly aqueous mobile phase conditions to achieve sufficient retention on the stationary phase. Conventional reversed phase selectivities do not give reproducible results under these conditions due mainly to the collapse of the C8 chains, Hydrosphere C8 has been developed, on the ultra pure silica support of the ProFamily, as the next generation of speciality phases following the well known YMC-Pack ODS-AQ, which was developed in 987 and is still a very interesting selectivity option for these purposes. Column Kits MD VAL R&D PS pages -

YMC ProFamily 75 Hydrosphere C8 Traditionally, YMC-Pack ODS-AQ was designed for the separation of polar compounds under 00% aqueous conditions and YMC-Pack Pro C8 for the separation of acidic and basic substances. As a consequence, Hydrosphere C8 could be understood as a synergy of the advantages of YMC-Pack ODS-AQ and YMC-Pack Pro C8. YMC-Pack ODS-AQ YMC-Pack Pro C8 + Hydrosphere C8 exceptional polar selectivity. Toluene. Testosterone. n-propylbenzene 4. Acenaphthene 5. n-butylbenzene 6. Amitriptyline hydrochloride symmetrical peaks even for strong bases Column: Hydrosphere C8 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 -K HPO 4 (ph 6.9) / methanol (5/65) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm

76 YMC ProFamily Hydrosphere C8 Properties In order to compare the differences and similarities of both reversed phases, nucleic acid bases are separated under pure aqueous eluent conditions on both selectivities. Interestingly uracil, normally used as a dead volume marker, can be retained on both phases, whereas adenine elutes later on YMC-Pack ODS-AQ. This peak on Hydrosphere C8 is virtually symmetrical with a tailing factor of.05, but on YMC-Pack ODS-AQ it shows a slightly tailing peak (with a tailing factor of.49). Hydrosphere C8 vs. YMC-Pack ODS-AQ YMC-Pack ODS-AQ Hydrosphere C8 Column: 50 x 4.6 mm Eluent: 0 mm KH PO 4 -K HPO 4 (ph 6.9) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm As a consequence, both Hydrosphere C8 and YMC-Pack ODS-AQ are the selectivities of choice within the YMC portfolio to separate polar compounds when using 00% aqueous eluent conditions. YMC-Pack ODS-AQ shows stronger retention for more hydrophobic substances, while Hydrosphere C8 is ideal for basic substances. Both selectivities are a must for approaching the separation of polar compounds. A proprietary derivatisation procedure enables Hydrosphere C8 to be penetrated by water without losing its brush-like chain structure. This model of the so-called phase collapse is one explanation for a phenomenon, where the retention times decrease after a very short time under 00% aqueous eluent on a conventional C8 phase. Solution: Hydrosphere C8 under 00% aqueous chromatographic conditions* (A) Hydrosphere C8 (B) stable retention!. Cytosine. Uracil. Guanine 4. Thymine 5. Adenine 4 hours Column: Hydrosphere C8 (5µm, nm) 50 x 4.6 mm i.d. Eluent: 0 mm KH PO 4 -K HPO (ph 6.9) Flow rate:.0 ml/min Temperature: 7 C Detection: UV at 54 nm After use, the column was stored overnight without any washing procedure. The next day, the application was continued. * By courtesy YMC Co., Ltd. Its hydrophilic C8 surface gives Hydrosphere C8 the capability to show stable retention times even after 4 hours under these chromatographic conditions.

YMC ProFamily 77 Hydrosphere C8 Finally, Hydrosphere C8 is, in common with all ProFamily members, applicable to LC-MS methods as shown below. High throughput LC-MS separations with enhanced flow rates are easily achievable with the µm version of Hydrosphere C8. LC-MS compatibility High throughput separation. Ofloxacin. Oxolinic acid. Nalidixic acid 4. Piromidic acid 4 56 7. Sulfisomidine. Sulfathiazole. Sulfamerazine 4. Sulfadimidine 5. Sulfamonomethoxine 6. Sulfamethoxazole 7. Sulfadimethoxine Column: Hydrosphere C8 ( µm, nm) 00 x.0 mm i.d. Eluent: 0 mm CH COOH - CH COONH 4 (ph 4.) / acetonitrile (75/5) Flow: 0. ml/min Detection: UV at 60 nm Temperature: 7 ºC Column: Hydrosphere C8 ( µm, nm) 50 x.0 mm i.d. Eluent: 0 mm CH COOH - CH COONH 4 (ph 4.6) / acetonitrile (85/5) Flow:.0 ml/min Detection: UV at 75 nm Temperature: 7 ºC Hydrosphere C8 is the column of choice within the YMC portfolio for a wide range of different substances. As an almost universal selectivity it can be used under standard reversed phase conditions as well as pure aqueous eluents as demonstrated by this collection of applications. No ion pair reagent required. Norepinephrine hydrochloride. Epinephine.,4-Dihydroxyphenylalanine (DOPA) 4. Dopamine hydrochloride 5. 4-Hydroxy--methoxymandelic acid 6. -Methosytyramine hydrochloride 7. 4-Hydroxy--methoxyphenylglycol 8.,4-Dihydroxyphenylacetic acid 9. Homovanilic acid Efficient separation of complex substance mixtures. Pyridoxine HCl. Maleic acid. Neostigmine methylsulfate 4. Naphazoline HCl 5. Chlorpheniramine 6. Glycyrrhizin Catecholamines Column: Hydrosphere C8 (5 µm, nm) 50 x 4.6 mm i.d. Eluent: A) 50 mm KH PO 4 - H PO 4 (ph.) B) 50 mm KH PO 4 - H PO 4 (ph.) / acetonitrile (90/0) 0% B (0-5 min), 0-00% B (5-5 min, linear), 00% B (5-5 min) Flow:.0 ml/min Detection: UV at 80 nm, 0.64 AUFS Temperature: 0 ºC Injection: 0 µl (0.5-0.5 mg/ml) Ingredients in an eye drop Column: Hydrosphere C8 ( µm, nm) 50 x 4.6 mm i.d. Eluent: A) 0 mm KH PO 4 - H PO 4 (ph.5) B) acetonitrile 0-60% B (0-0 min), 60% B (0-5 min) Flow rate:.0 ml/min Temperature: 7 ºC Detection: UV at 65 nm, 0.8 AUFS Injection: 5 µl (0.0-0. mg/ml) For more applications please refer to our Application Data Collections or contact us directly. Column care Hydrosphere C8 is stable towards hydrolysis between ph.0-8.0 in up to 00% aqueous systems and a maximum of 50 C. Remove acid and buffer salts before storage. Store the column in methanol / water = 70/0. For detailed information please refer to the Column Care and Use Instructions which are shipped with each analytical column.

78 YMC ProFamily Ordering Information YMC-Pack Pro C8, nm, μm Tested QC passed Guard Cartridges AS nm Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5). ASS000QT ASS0050QT ASS000QT ASS050QT ASS050QT ASS000.0 ASS000QT ASS0050QT ASS000QT ASS050QT ASS050QT ASS000 4.0 ASS0004QT ASS00504QT ASS0004QT ASS0504QT ASS0504QT ASS0004 4.6 ASS0046WT ASS00546WT ASS0046WT ASS0546WT ASS0546WT ASS0004 For other dimensions please refer to page 8 YMC-Pack Pro C8, nm, 5 μm AS nm 5 For Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5). ASS0500QT ASS05050QT ASS0500QT ASS0550QT ASS0550QT ASS0500.0 ASS0500QT ASS05050QT ASS0500QT ASS0550QT ASS0550QT ASS0500 4.0 ASS05004QT ASS050504QT ASS05004QT ASS05504QT ASS05504QT ASS05004 4.6 ASS05046WT ASS050546WT ASS05046WT ASS05546WT ASS05546WT ASS05004 other dimensions please refer to page 8 YMC-Pack Pro C8, nm, μm OS nm Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5). OSS000QT OSS0050QT OSS000QT OSS050QT OSS050QT OSS000.0 OSS000QT OSS0050QT OSS000QT OSS050QT OSS050QT OSS000 4.0 OSS0004QT OSS00504QT OSS0004QT OSS0504QT OSS0504QT OSS0004 4.6 OSS0046WT OSS00546WT OSS0046WT OSS0546WT OSS0546WT OSS0004 For other dimensions please refer to page 8 YMC-Pack Pro C8, nm, 5 μm OS nm 5 Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5). OSS0500QT OSS05050QT OSS0500QT OSS0550QT OSS0550QT OSS0500.0 OSS0500QT OSS05050QT OSS0500QT OSS0550QT OSS0550QT OSS0500 4.0 OSS05004QT OSS050504QT OSS05004QT OSS05504QT OSS05504QT OSS05004 4.6 OSS05046WT OSS050546WT OSS05046WT OSS05546WT OSS05546WT OSS05004 For other dimensions please refer to page 8

YMC ProFamily 79 Ordering Information YMC-Pack Pro C4, nm, μm Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5). BSS000QT BSS0050QT BSS000QT BSS050QT BSS050QT BSS000.0 BSS000QT BSS0050QT BSS000QT BSS050QT BSS050QT BSS000 4.0 BSS0004QT BSS00504QT BSS0004QT BSS0504QT BSS0504QT BSS0004 4.6 BSS0046WT BSS00546WT BSS0046WT BSS0546WT BSS0546WT BSS0004 For other dimensions please refer to page 8 BS nm YMC-Pack Pro C4, nm, 5 μm Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5) BS. BSS0500QT BSS05050QT BSS0500QT BSS0550QT BSS0550QT BSS0500.0 BSS0500QT BSS05050QT BSS0500QT BSS0550QT BSS0550QT BSS0500 4.0 BSS05004QT BSS050504QT BSS05004QT BSS05504QT BSS05504QT BSS05004 4.6 BSS05046WT BSS050546WT BSS05046WT BSS05546WT BSS05546WT BSS05004 For other dimensions please refer to page 8 nm 5 YMC-Pack Pro C8 RS, 8 nm, μm Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5) RS. RS08S000QT RS08S0050QT RS08S000QT RS08S050QT RS08S050QT RS08S000.0 RS08S000QT RS08S0050QT RS08S000QT RS08S050QT RS08S050QT RS08S000 4.0 RS08S0004QT RS08S00504QT RS08S0004QT RS08S0504QT RS08S0504QT RS08S0004 4.6 RS08S0046WT RS08S00546WT RS08S0046WT RS08S0546WT RS08S0546WT RS08S0004 For other dimensions please refer to page 8 8 nm YMC-Pack Pro C8 RS, 8 nm, 5 μm Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5) RS. RS08S0500QT RS08S05050QT RS08S0500QT RS08S0550QT RS08S0550QT RS08S0500.0 RS08S0500QT RS08S05050QT RS08S0500QT RS08S0550QT RS08S0550QT RS08S0500 4.0 RS08S05004QT RS08S050504QT RS08S05004QT RS08S05504QT RS08S05504QT RS08S05004 4.6 RS08S05046WT RS08S050546WT RS08S05046WT RS08S05546WT RS08S05546WT RS08S05004 For other dimensions please refer to page 8 Note: For your first order on guard cartridges, please add one guard cartridge holder per system to your order list: integral guard cartridge holder for columns with.-4.0 mm i.d. XPGCS-Q or universal guard cartridge holder for columns with 4.6 mm i.d. XPGCH-Q The holder can continuously be re-used and, thus it is not required for repeat orders. 8 nm 5

80 YMC ProFamily Ordering Information HS nm YMC-Pack Hydrosphere C8, nm, μm Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5). HSS000QT HSS0050QT HSS000QT HSS050QT HSS050QT HSS000.0 HSS000QT HSS0050QT HSS000QT HSS050QT HSS050QT HSS000 4.0 HSS0004QT HSS00504QT HSS0004QT HSS0504QT HSS0504QT HSS0004 4.6 HSS0046WT HSS00546WT HSS0046WT HSS0546WT HSS0546WT HSS0004 For other dimensions please refer to page 8 Tested QC passed Guard Cartridges HS nm 5 YMC-Pack Hydrosphere C8, nm, 5 μm Column Column length (mm) Guard cartridges i.d. with 0 mm length (mm) 50 00 50 50 (pack of 5). HSS0500QT HSS05050QT HSS0500QT HSS0550QT HSS0550QT HSS0500.0 HSS0500QT HSS05050QT HSS0500QT HSS0550QT HSS0550QT HSS0500 4.0 HSS05004QT HSS050504QT HSS05004QT HSS05504QT HSS05504QT HSS05004 4.6 HSS05046WT HSS050546WT HSS05046WT HSS05546WT HSS05546WT HSS05004 For other dimensions please refer to page 8 Sure-Fit TM Connector Since different column hardware manufacturers have introduced a variety of connecting port geometries over the years, the Sure-Fit TM Connector represents an ideal tool to avoid dead volumes or leakages, irrespective of the column brand, when connecting different columns to an HPLC system. YMC strongly recommends the use of the Sure-Fit TM Connector due to its internal spring tensioned mechanism, which automatically self-adjusts to any port depth while maintaining constant pressure on the capillary tubing. This guarantees a connection free from any dead volume. Column changeovers become easy, especially as no tools are required. The Sure-Fit TM Connector is fingertight to 6000 psi and is available in a range of capillary tubing i.d. and lengths. Column i.d.* Tubing i.d.* Single end unit Double end unit (mm) (mm) (incl. 0 mm stainless steel capillary) (incl. 0 mm stainless steel capillary).0-.0 0. SFS005 SFD005.0-4.6 0.8 SFS007 SFD007 * Other versions available on request

YMC ProFamily 8 Ordering Information The previous product listing represents commonly used standard column dimension. In order to identify any specific product version and order number, please see the example and the table below. Full listing of all chemistries and dimensions Chemistry code Gel Code Hardware Code Pore size Particle size Length Inner diameter Column [nm] Particle shape [µm] [mm] [mm] Type YMC0 CT 6 06 spherical S 0 0 0 0.05 E5 Quick Seal QT Pro C8 AS 8 08 4 04 0 0 0.075 E8 Cartridge QC Pro C8 RS RS 5 05 0 0. F0 Waters type WT Hydrosphere C8 HS 0 0 6 06 50 05 0. G0 ODS-A AA 0 0 75 L5 0. H0 ODS-AM AM 00 A0 0 00 0 0.5 J0 ODS-AQ AQ proprietary 99 5 6 5 R5 0.8 M0 J sphere ODS-H80 JH non-porous 00 0 50 5.0 0 J sphere ODS-M80 JM 50 50 50 5. 0 J sphere ODS-L80 JL 75 75.0 0 ODS-AL AL 00 0 4.0 04 PAH YP 6/0 A4 PolymerC8 PC 50 A5 500 50 4.6 46 Pro C8 OS 000 A0 6.0 06 C8 (Octyl) OC 8.0 08 YMCbasic BA 0 0 Ph (Phenyl) PH 0 0 Pro C4 BS 0 0 C4 (Butyl) BU Protein-RP PR 50 (000 psi) 5 TMS (C) TM 70 (000 psi) 7 PVA-Sil PV 00 (000 psi) A Polyamine II PB 50 (000 psi) B NH (Amino) NH 00 (000 psi) C CN (Cyano) CN Diol DL SIL (Silica) SL BioPro-QA BioPro-SP BioPro-QA-F BioPro-SP-F Chiral NEA (R) Chiral NEA (S) Chiral CD BR α Chiral CD BR β Chiral CD BR γ QA SP QF SF NR NS DA DB DG Chiral Prep CD ST ST Chiral Prep CD PM PM Example Choose your column and fill in the Gel and Hardware Code or detailed description (The part number consists of the Gel Code and the Hardware Code ). YMC-Pack ODS-A nm spherical µm 50 mm.0 mm Quick Seal AA S 0 5 0 QT Your column part number: AAS050QT (Example) Please note that combinations of features cannot be selected at random, but only from the possible specifications for a chosen stationary phase. These can be determined from the individual product sections in this catalogue or from our homepage www.ymc.de. For more details contact your local distributor or YMC Europe GmbH, Schöttmannshof 9, D-4659 Dinslaken, Phone: +49 (0) 064 / 47-0, Fax +49 (0) 064 / 47-, e-mail: info@ymc.de, homepage: www.ymc.de