Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Similar documents
Component specific particle characterisation of the active components in a pharmaceutical topical formulations

Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Understanding the colloidal stability of protein therapeutics using dynamic light scattering

GPC/SEC Analysis of Polymer Degradation

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

Use of DLS/Raman to study the thermal unfolding process of lysozyme

Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis

Differentiation of polymer branching and composition using the Mark Houwink plot

Using rheology to study the hardness and spreadability of butter

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

The power of multi-detector SEC in the analysis of antibodies

How to use GPC/SEC for compositional analysis

Introduction to the calculators in the Zetasizer software

Studying the Effect of Steric Layer Thickness on Emulsion Stability

How switching mobile phases can improve your OMNISEC results

Characterization of Single Wall Carbon Nanotubes (SWNTs) by combining Dynamic Light Scattering and Raman Spectroscopy

Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications

Executive Summary. Introduction WHITEPAPER

Laser diffraction and automated imaging: complementary techniques for nasal spray development

Measuring the rheology of thermoplastic polymer melts

Understanding the conformational stability of protein therapeutics using Raman spectroscopy

REVERSE ENGINEERING PHARMACEUTICAL FORMULATION USING THE MORPHOLOGI G3-ID.

Using the Zetasizer Nano to optimize formulation stability

DEVELOPING A BIOFORMULATION STABILITY PROFILE

Morphologically directed chemical identification Coupling particle characterization by morphological imaging with Raman spectroscopy

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Zeta potential - An introduction in 30 minutes

Inform is a series of white papers designed to provide advice on material characterization issues. Mie theory The rst 100 years

KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

Measuring the rheology of polymer solutions

The Diffusion Barrier Technique, Practical Aspects and Data interpretation

The ultimate in desktop particle characterization

The ultimate in desktop particle characterization

MORPHOLOGI 4 RANGE. Automated imaging for advanced particle characterization

Introducing the Morphologi G3 ID The future of particle characterization

Gold Nanoparticle Applications and Characterization by Nanoparticle Tracking Analysis

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP

A basic guide to particle characterization

Preformulation & Solid State Chemistry Services

CARBON NANOTUBE ANALYSIS USING THE TSI LIBS DESKTOP ANALYZER

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

Agilent Cary 630 FTIR sample interfaces combining high performance and versatility

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

Nanoscale IR spectroscopy of organic contaminants

Portable Raman Spectroscopy for the Study of Polymorphs and Monitoring Polymorphic Transitions

Method validation for laser diffraction measurements

MASTERSIZER 3000 SMARTER PARTICLE SIZING

Sample measurements to demonstrate Zetasizer specifications (Zetasizer Nano, Zetasizer APS, Zetasizer μv)

Positive and Nondestructive Identification of Acrylic-Based Coatings

Measuring the flow properties of powders. FT4 Powder Rheometer. freemantechnology

BIO & PHARMA ANALYTICAL TECHNIQUES. Chapter 5 Particle Size Analysis

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SARA Pharm Solutions

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Snowy Range Instruments

Introduction to Fourier Transform Infrared Spectroscopy

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

A Basic Guide to INFORM WHITE PAPER. Abstract:

Supporting Information s for

Characterization of Solid State Drugs by Calorimetry

Surface Zeta Potential Cell (ZEN1020)

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Pharmaceutical Characterisation. Dr. Lidia Tajber and Dr. Krzysztof Paluch School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin

Electrophoretic Light Scattering Overview

Particle Characterization of Pharmaceutical Products by Dynamic Image Analysis

An automated synthesis programme for drug discovery

Setting the Standard for Advanced GPC/SEC Systems

Biophysical characterization of SMALPs and nanodiscs

Analysis of Fluorofentanyl Isomer Compounds by Gas-Chromatography Coupled with Solid Phase Infrared Detector IR_AN_047

High Pressure DSC Differential Scanning Calorimeter

APPLICATION NOTE. Supercontinuum Generation in SCG-800 Photonic Crystal Fiber. Technology and Applications Center Newport Corporation

Systems, services and solutions for material characterization

Supporting Information

Physicochemical Characterization of Binary Ionic Polymer Blends: Polyvinyl Acetate Phthalate and Eudragit E PO

Particle Size and Shape Analysis in PHARMACEUTICAL INDUSTRY.

Benchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample

Introduction to Fourier Transform Infrared Spectroscopy

ZETASIZER NANO Series PERFORMANCE, SIMPLICITY, VERSATILITY

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

Agilent Cary 630 FTIR Spectrometer Supporting Organic Synthesis in Academic Teaching Labs

Advantages of coincident XPS-Raman in the analysis of mineral oxides species

MASTERSIZER 3000 SMARTER PARTICLE SIZING

DVS INTRINSIC. The easy-to-use solution to complex water sorption challenges.

Fast, Effective XPS Point Analysis of Metal Components

Your partner in Science!

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Avery Dennison LW Series Retroreflective Window Sticker Film Issued: July 2013

Thermal correction - workpiece expansion. Thermal correction - workpiece expansion AP306. Problem

TABLE OF CONTENTS. vii

The Analysis of Organophosphate Pesticides by LC/MS Application

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

ATR FTIR imaging in forensic science

Pulsar. Delivering NMR to your benchtop

Transcription:

Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS) CHEMICAL IDENTIFICATION PARTICLE SIZE PARTICLE SHAPE Introduction Interest in studying mixed systems of pharmaceutical relevance is not a new concept. From intrinsic polymorphism to complex final products, the challenges encountered by modern analytical scientists have multiplied both in number and in complexity. Established techniques are often unable to provide both separation and identification of species in a mixed system, as they are used to probe chemistry (bulk spectroscopy), or individual particle characteristics (microscopy and SEM). Combining techniques capable of analyzing micronscale particulates with absolute chemical specificity provides a new window into describing the complicated mixtures common in today s competitive pharmaceutical market. Malvern Instruments Morphologi G3-ID provides just such a technology combination, uniting automated microscopy and spectroscopy in an integrated package. This partnering of techniques has been termed Morphology-Directed Raman Spectroscopy (MDRS). Raman spectroscopy is sensitive to the unique polymorphic forms of a substance, and can be used to investigate single particles to assist in determining the long-term stability of a product. Correlations may be established between morphological and spectroscopic results, where morphologically-distinct particle groups are found to share common spectra, and vice versa. The ability of MDRS to target particles of distinct morphology for Raman investigation provides added sensitivity to the measurement, as spectra for particles that are not of interest are not measured. Likewise, knowing that a group of particles with similar spectra may be described by a common morphology allows the analyst to assess particulate quantity in the absence of measuring a spectrum for each particle in the morphologically-similar group. Such correlations between particle morphology and chemical identity allow MDRS to provide an improvement in efficiency over manual methods. Malvern Instruments Worldwide Sales and service centres in over 65 countries www.malvern.com/contact 2015 Malvern Instruments Limited

Materials and Methods A polymorphic mixture of common pain-relief medication was investigated using the Morphologi G3-ID to characterize samples which provides the size, shape, and chemical identity of sample particulates. The polymorphic mixture consisted of the Type I and Type II polymorphs of acetaminophen (also known as paracetamol), Acetaminophen in its Type I form (Fisher (98%, AC102332500)) was recrystallized by slowly cooling a saturated solution in water at 60 C 1. The resulting material was recovered and dried at 75 C for eight hours, at which point half of the sample (Type I) was removed and the other half heated to 170 C to effect the Type I to Type II polymorphic conversion 2. A volumetric fraction consisting of 9 parts Type I to 1 part Type II by weight was milled for 1 minute in a hand mill. 3 mm 3 of the resulting mixed powder was placed into the dry dispersion accessory for the Morphologi G3-ID and dispersed at a pressure of 4 bar onto a quartz plate. A 20 mm diameter area was scanned at 5x magnification to detect acetaminophen particles, and 1375 particles were selected for Raman measurement based on the following size categories: greater than 50 μm, 25 μm to 50 μm, and 10 to 25 μm. Reference spectra for Raman analysis were obtained from pure materials. Spectra were collected with a 785 nm laser (20 mw) illuminating a 3 μm spot size at 50x magnification, and covering a range from 150 cm -1 to 1850 cm -1 at 6 cm -1 resolution. Results Over 70,000 individual particles were detected for the 9 (Type I):1 (Type II) acetaminophen mixture. The sample was polydisperse, with some particles greater than 400 μm detected. Examples of the particles analyzed and their final size distribution are shown in Figure 1. 2 Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Figure 1: Representative particle images from the polymorph acetaminophen mixture (left panel) and the size distribution (volume weighted, right panel). The morphological results show that the hand mill produces a broad distribution of sizes. It is also apparent that a few large particles (greater than 200 μm) are still present in the final dispersion. The size distribution result is used to classify the particles based on size (10 μm to 25 μm, 25 μm to 50 μm, and greater than 50 μm) for Raman investigation. Particles below 10 μm were excluded from Raman analysis. The results of correlation against the library of pure polymorph spectra revealed 1220 Type I particles and 144 Type II particles, out of 1375 particles targeted, corresponding to 10.5% Type II polymorph. The pure reference spectra and examples of particle spectra are shown in figure 2. The correlation was constrained to contain only the 1200 cm -1 to 1260 cm -1 and 1540 cm -1 to 1590 cm -1 regions (indicated by the green areas in figure 2) where the two species are readily distinguishable. A correlation score of greater than 0.85 was required for a positive identification as either Type I or Type II. Mixture spectra (correlation to both Type I and Type II references with scores greater than 0.85) were detected for 11 particles, an example is also shown in figure 2. 3 Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Figure 2: Raman spectra collected from example particulates for acetaminophen Type I (blue), acetaminophen Type II (red), and a mixture spectrum (black). The Type I and Type II spectra are superimposed over reference spectra used to create the library (black dotted). The portions of the spectrum in green are those used for correlation to the reference library. The agreement between the recorded and library spectra is outstanding, and allows for simple discrimination between the two polymorph types within the confines of the correlation analysis. The mixture spectra identified for a subset particles are most likely due to the formation of aggregates during dispersion. Once the spectroscopic data is available, the morphologies of the two species can be reviewed to determine if it is possible to segregate similar looking materials based solely on their morphologies. In the present example, results confirm that the Type I particles have a higher Intensity Mean than the Type II particles, meaning that Type I particles are more transparent, as shown in Figure 3. However, whilst a clear difference in the transparency of the two particle types exists it should be noted that there is some overlap between the Intensity Mean distributions, which suggests that it is not a definitive morphological separator. No other morphological descriptors indicated a significant difference between the particle types, most likely due to loss of morphological information during the milling process. This situation emphasizes the importance of having a referee technique, such as Raman spectroscopy, available to discriminate between different chemical species. 4 Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Figure 3: Intensity Mean distribution for the Type I and Type II particles as determined by the Raman spectroscopic results. Insets display example images of particles from each group. Discussion Polymorphic conversions are considered an ongoing problem in the pharmaceutical industry. Process conditions, improper storage, and simply time can effect the transition from a stable, efficacious form of a drug substance into an unwanted structural analogue. Thus, establishing the presence of multiple polymorphic forms is of great interest to both innovator and generic pharmaceutical companies alike. Vibrational spectroscopy has found wide use as a tool with the requisite sensitivity to establish the presence of multiple polymorphic forms in a mixed system. Unfortunately, commonly-available bulk spectroscopic techniques lack the sensitivity to detect the low levels of polymorphic contaminants that may be present in final products. Additionally, bulk techniques provide only an overview of the material that is present in the sample area, and have no ability to partition the sample into individual particles to provide specific characterization. 5 Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Conclusion MDRS thus provides clear advantages over traditional methods of vibrational spectroscopy, and is well-suited to address low-level polymorphic contamination directly. Spectra are collected for single particles, which allow at least an order of magnitude increase in detection sensitivity. Data collection can be conducted for any number of particulates desired, and unique spectra are easily identified. As mentioned previously, the morphological characteristics of particulates can also be used to further refine the selectivity of the method. If different polymorphic forms have distinct morphology, the method can be modified to investigate only those that fit a particular morphological profile. These strengths position MDRS as a technique that can handle the most difficult polymorphic mixtures with unparalleled sensitivity and flexibility, providing a new tool for root cause analysis, product quality, and formulation development. References 1. Lee T., Kuo C.S., and Chen Y.H. Oct. 2, 2006. Solubility, Polymorphism, Crystallinity, and Crystal Habit of Acetaminophen and Ibuprofen by Initial Solvent Screening. Pharmaceutical Technology. 2. Di Martino P., Conflant P., Drache M., Huvenne J.-P., and Guyot-Hermann A.-M. 1997. Preparation and Physical Characterization of Forms II and III of Paracetamol. Journal of Thermal Analysis (48): 447-458. 6 Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Malvern Instruments Limited Grovewood Road, Malvern, Worcestershire, UK. WR14 1XZ Tel: +44 1684 892456 Fax: +44 1684 892789 www.malvern.com Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company. Spectris and the Spectris logo are Trade Marks of Spectris plc. All information supplied within is correct at time of publication. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Malvern Instruments owns the following registered trademarks: Bohlin, FIPA, Insitec, ISYS, Kinexus, Malvern, Malvern 'Hills' logo, Mastersizer, MicroCal, Morphologi, Rosand, 'SEC-MALS', Viscosizer, Viscotek, Viscogel and Zetasizer. 2015 Malvern Instruments Limited AN150622Discrim2PolymorphsAcetamMDRS