APPLICATION OF GLOBAL STRAIN EXTENSOMETER (GLOSTREXT) METHOD FOR INSTRUMENTED BORED PILES IN MALAYSIA

Similar documents
Lesson 25. Static Pile Load Testing, O-cell, and Statnamic. Reference Manual Chapter 18

OP-023. INTERPRETATION OF INSTRUMENTED TEST PILE RESULT

PILE LOAD TEST IN OLD ALLUVIUM

Interpretation of Pile Integrity Test (PIT) Results

Local Construction Practice and Geotechnical Performance of Rock Socketed Bored Pile in Sedimentary Crocker Range Formation in Sabah

SI Planning & Laboratory Testing for Hill-Site Development

Rapid Load Test from Theory to Practice in Singapore. 1. Introduction

CPT Guide 5 th Edition. CPT Applications - Deep Foundations. Gregg Drilling & Testing, Inc. Dr. Peter K. Robertson Webinar # /2/2013

Deep Foundations 2. Load Capacity of a Single Pile

INCREASE IN PILE CAPACITY WITH TIME IN MISSOURI RIVER ALLUVIUM

CHAPTER 8 ANALYSES OF THE LATERAL LOAD TESTS AT THE ROUTE 351 BRIDGE

VMS-GeoMil. Background

MEASUREMENT AND PREDICTION OF THE LOAD DISTRIBUTION AND PERFORMANCE OF CONTINUOUS FLIGHT AUGER PILES

Discussion: behaviour of jacked and driven piles in sandy soil

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

THE STRUCTURAL DESIGN OF PILE FOUNDATIONS BASED ON LRFD FOR JAPANESE HIGHWAYS

Views on Accuracy of Tests and Analyses

25th International Conference on Ground Control in Mining

BE Semester- I ( ) Question Bank (MECHANICS OF SOLIDS)

Core Barrels. Core Barrels

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Comparisons of rapid load test, dynamic load test and static load test on driven piles

TC211 Workshop CALIBRATION OF RIGID INCLUSION PARAMETERS BASED ON. Jérôme Racinais. September 15, 2015 PRESSUMETER TEST RESULTS

INTRODUCTION TO STATIC ANALYSIS PDPI 2013

THE PREDICTION OF FINAL SETTLEMENT FROM 1D-CONSOLIDATION TEST: A CASE STUDY

Comparison of Static and Dynamic Pile Load Tests at Thi Vai International Port in Viet Nam

NONLINEAR CHARACTERISTICS OF THE PILE-SOIL SYSTEM UNDER VERTICAL VIBRATION

GEOTECHNICAL SOLUTIONS FOR UNSTABLE ROCK MASS AT SG. BULOH AREA

Chapter 12 Subsurface Exploration

FLAC3D analysis on soil moving through piles

The University of Melbourne Engineering Mechanics

IN SITU TESTING TECHNOLOGY FOR FOUNDATION & EARTHQUAKE ENGINEERING. Wesley Spang, Ph.D., P.E. AGRA Earth & Environmental, Inc.

Two Case Studies on Soil Nailed Slope Failures

Sensors and Transducers. mywbut.com

Maximum Envelope of Lateral Resistance through Dynamic Increasing Energy Test in Piles

PERFORMANCE OF BITUMINOUS COATS IN REDUCING NEGATIVE SKIN

Neutral Plane Method for Drag Force of Deep Foundations and the AASHTO LRFD Bridge Design Specifications

Soil type identification and fines content estimation using the Screw Driving Sounding (SDS) data

Conventional Field Testing & Issues (SPT, CPT, DCPT, Geophysical methods)

Cone Penetration Testing in Geotechnical Practice

DRILLED DISPLACMENT PILE PERFORMANCE IN COASTAL PLAIN AND RESIDUAL SOILS

Bored Sockets in weathered Basalt

ANALYSIS OF LATERALLY LOADED FIXED HEADED SINGLE FLOATING PILE IN MULTILAYERED SOIL USING BEF APPROACH

HELICAL BUCKLING OF DRILL-STRINGS

Use of Ultra-High Performance Concrete in Geotechnical and Substructure Applications

SIDE FRICTION OF DRILLED PILES IN COBBLE LAYERS

CHAPTER 3 EXPERIMENTAL STUDY

AE302,ME302,DAE14,DME14

Mechatronics II Laboratory EXPERIMENT #1: FORCE AND TORQUE SENSORS DC Motor Characteristics Dynamometer, Part I

Foundation Engineering Prof. Mahendra Singh Department of Civil Engineering Indian Institute of Technology, Roorkee

Liquefaction Induced Negative Skin Friction from Blast-induced Liquefaction Tests with Auger-cast Piles

ENVIRONMENTAL EFFECTS OF EARLY AGE AND LONG TERM RESPONSE OF PCC PAVEMENT

Net load displacement estimation in soil-nail pullout tests

Measurement of effective stress shear strength of rock

Christian Linde Olsen Griffith University, Faculty of Engineering and Information Technology, Gold Coast Campus.

KDOT Geotechnical Manual Edition. Table of Contents

Dimension measurement. By Mr.Vuttichai Sittiarttakorn

Engineeringmanuals. Part2

ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 10, NO. 5 (2009) PAGES **-**

Rotary Drilling Rotary Drilling Bits

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

Verification of a Micropile Foundation

Experimental Investigation of Soil-Pipe Friction Coefficients for Thermoplastic Pipes Installed in Selected Geological Materials

1. ARRANGEMENT. a. Frame A1-P3. L 1 = 20 m H = 5.23 m L 2 = 20 m H 1 = 8.29 m L 3 = 20 m H 2 = 8.29 m H 3 = 8.39 m. b. Frame P3-P6

Geotechnical Engineering Study, Conifer Senior High School Football Field Improvements, Conifer, Colorado

Mechanical Response of a Composite Steel, Concrete- Filled Pile

Dynamic Response of EPS Blocks /soil Sandwiched Wall/embankment

Determining In Situ Properties of Claystone Aquitards Using Pore Pressure Responses from Grouted-in Pressure Transducers

ANALYSES OF SOIL-STRUCTURE INTERACTION BASED ON VERTICAL LOAD TESTS OF DISPLACEMENT PILES

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

EQUIVALENT FRACTURE ENERGY CONCEPT FOR DYNAMIC RESPONSE ANALYSIS OF PROTOTYPE RC GIRDERS

Evaluation of the Liquefaction Potential by In-situ Tests and Laboratory Experiments In Complex Geological Conditions

DEVELOPMENT OF AUTOMATIC CONTROL OF MULTI-STAGE TRIAXIAL TESTS AT THE UNIVERSITY OF MISKOLC

ON THE PREDICTION OF EXPERIMENTAL RESULTS FROM TWO PILE TESTS UNDER FORCED VIBRATIONS

Back Analysis of Measured Displacements of Tunnels

B-1 SURFACE ELEVATION

Instructional Objectives

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

DEPARTMENT OF MECHANICAL ENIGINEERING, UNIVERSITY OF ENGINEERING & TECHNOLOGY LAHORE (KSK CAMPUS).

INTI COLLEGE MALAYSIA

Axially Loaded Piles

Mechatronics II Laboratory EXPERIMENT #1 MOTOR CHARACTERISTICS FORCE/TORQUE SENSORS AND DYNAMOMETER PART 1

Advanced numerical modelling methods of rock bolt performance in underground mines

The theories to estimate lateral earth pressure due to a strip surcharge loading will

World Academy of Science, Engineering and Technology International Journal of Geotechnical and Geological Engineering Vol:11, No:9, S.

VIBRATION MEASUREMENT OF TSING MA BRIDGE DECK UNITS DURING ERECTION

THEME IS FIRST OCCURANCE OF YIELDING THE LIMIT?

IDE 110 Mechanics of Materials Spring 2006 Final Examination FOR GRADING ONLY

Feasibility of dynamic test methods in classification of damaged bridges


Part 2. Sensor and Transducer Instrument Selection Criteria (3 Hour)

Experimental study of sand deformations during a CPT

NEW DOWN-HOLE PENETROMETER (DHP-CIGMAT) FOR CONSTRUCTION APPLICATIONS

14:1400 (0206) KRAL Volumeter - OMG

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

ELASTOPLASTIC STEEL BEAM BENDING ANALYSIS BY USING ABAQUS

Investigation of Pile- Soil Interaction Subjected to Lateral Loads in Layered Soils

Effective stress analysis of pile foundations in liquefiable soil

Transcription:

Paper published in 1 th International Conference on Piling and Deep Foundations, 31 st May 2 nd June, Amsterdam. APPLICATION OF GLOBAL STRAIN EXTENSOMETER (GLOSTREXT) METHOD FOR INSTRUMENTED BORED PILES IN MALAYSIA Abdul Aziz Hanifah, Senior Assistant Director, Public Works Department, Kuala Lumpur. Lee Sieng Kai, Managing Director, Glostret Technology Sdn. Bhd., Kuala Lumpur, Malaysia. A novel instrumentation and analysis technique, called GLOSTREXT method has recently been introduced for bored pile load tests in Malaysia. This technique provides an innovative and improved alternative for conventional bored pile instrumentation methods commonly practiced for the past few decades. Results for five case histories involving full scale static load tests for high capacity bored piles with both new and conventional instrumentation details placed in within the same instrumented piles are presented to demonstrate the advantages of this novel technique. Results show good agreement between the new and conventional instrumentation. INTRODUCTION Over the past few decades, there is an obvious lack of innovation in the area of instrumentation and monitoring for the classical static load tests, while other indirect or alternative pile test methods such as Dynamic Load Tests, Statnamic Load Tests and Bi-Directional O-Cell Load Testing had undergone significant improvements in recent years. A conventional bored pile instrumentation method for static load testing is shown in Fig.1(a). In general, vibrating wire strain gauges and mechanical tell-tales are installed and cast within the pile to allow for monitoring of aial loads and movements at various levels down the pile shaft including the pile toe level. The constraints with this method includes long lead-time required for instrumentation, instruments have to be pre-assembled and installed onto the steel cage prior to concreting of the pile, information on pile length and instrument locations has to be planned and predetermined before the drilling and installation of the test pile. Strain gauges give localized strain measurements and are sensitive to variations in pile cross-section. Sleeved rod tell-tales often gives unsatisfactory results due to rod friction, bowing, eccentricity of loading and reference beam movement. The movement for lower portions of pile shaft is particularly difficult to be reliably measured most of the time. When instrumentation levels increases for a particular comple soil strata or geological structure, it is sometimes not practical to put tell-tales at every level due to congestion of the sleeved pipes in the piles, as well as difficulty in monitoring set-up at the pile head. Instrumented Test Bored Pile Apllied load measured by vw load cells Pile head P Top Platform level Verify and backcalculate Ec Strain Gauges Lev. A P B P C P D P E Strain Gauges Lev. B Tell-tale Etensometer 1 Strain Gauges Lev. C Strain Gauges Lev. D Strain Gauges Lev. E Tell-tale Etensometer 2 P F Strain Gauges Lev. F Pile toe Legend: denotes Vibrating Wire Strain Gauges denotes mechanical tell-tale etensometer Fig.1(a) : Conventional pile instrumentation While development of removable etensometers in full scale static load tests (Bustamante et al 11) had been very successful and unique in Europe for many years now, the advancement had not been 1

Paper published in 1 th International Conference on Piling and Deep Foundations, 31 st May 2 nd June, Amsterdam. materialized in this part of the world. Thanks to a new generation of pneumatic retrievable etensometer anchors coupled with highprecision spring-loaded vibrating-wire sensors (Geokon, 1, 23), highly accurate measurements of the relative deformations of anchored segments across entire pile lengths are now possible to be logged with relative ease during static load testing. The paper s main focus is to highlight the several advantages of GLOSTREXT method and high correlation between GLOSTREXT method and conventional instrumentation from the results of five case histories involving both instrumentation details placed in within the same instrumented piles. DESCRIPTION OF GLOSTREXT METHOD The GLOSTREXT Method for static load testing on bored piles is a deformation monitoring system using advanced pneumatically anchored etensometers and a novel analytical technique for determining aial loads and movements at various levels down the pile shaft including the pile base level. This method is particularly useful for monitoring pile performance and optimizing pile foundation design. To appreciate the basic innovation contained in the GLOSTREXT Method, the deformation measurement in the pile by strain gauges and tell-tale etensometers are reviewed. Normally, strain gauges (typically short gauge length) are used for strain measurement at a particular level or spot, while tell-tale etensometers (typically long sleeved rod length) are used purely for shortening measurement over an interval (over a length between two levels). From a strain measurement point of view, the strain gauge gives strain measurement over a very short gauge length while the tell-tale etensometer gives strain measurement over a very long gauge length! Tell-tale etensometer that measure strain over a very long gauge length may be viewed as a very large strain gauge or simply called global strain etensometer. With recent advancement in the manufacturing of retrievable etensometers such as state-ofthe-art vibrating wire etensometers, it is now possible to measure strain deformation over the entire length of piles in segments with ease during static load testing. Fig.1(b) illustrates typical arrangement of retrievable vibrating wire etensometers in test pile, permitting improved monitoring of aial loads and movements at various levels down the pile shaft including the pile base level using GLOSTREXT Method. Generally two strings of retrievable vibrating wire etensometers with or anchors are adequate to yield improved results for instrumented static load tests. This system is equivalent to the conventional method of using no. VW Strain Gauges and no. sleeved rod etensometers, which might not be possible to be installed satisfactorily due to congestion in small-sized piles. Instrumented Test Bored Pile Apllied load measured by vw load cells Pile head P Top Anchored Lev. A Verify and back- GLOSTREXT Sensor 1 calculate E c Anchored Lev. B GLOSTREXT Sensor 2 Anchored Lev. C Fig.1(b) : GLOSTREXT pile instrumentation CASE HISTORIES P Ave(BC) GLOSTREXT Sensor 3 Gauge P Ave(CD) Length Anchored Lev. D GLOSTREXT Sensor Anchored Lev. E GLOSTREXT Sensor Anchored Lev F GLOSTREXT Sensor P Ave(DE) P Ave(EF) P Ave(FG) Anchored Lev. G Pile toe Legend: denotes GLOSTREXT anchored level denotes GLOSTREXT Vibrating Wire Sensor The results of five instrumented sacrificial bored test piles namely,,, and PTP, involving full scale static load tests with both new and conventional instrumentation details placed within the same piles are presented. The load tests were conducted with great care and control as described in following subsections. All the monitoring instruments were measured automatically during the loading and unloading cycles using a data-logger system. Fig.2 gives a typical illustration for instrumentation and monitoring set-up. 2

Paper published in 1 th International Conference on Piling and Deep Foundations, 31 st May 2 nd June, Amsterdam. ICW1 site Johor Strait Fig.3(a): Site location plan pile location and pile instrumentation details are graphically represented in Figure 3(b). Fig.2: Typical pile test instrumentation and monitoring set-up Subsurface Conditions and Piles Instrumentation Scheme The location of the site [Figure 3(a)] is at Interchange No.1 (ICW1), part of Southern Integrated Gate Project located at Johor Bahru, Johor, Malaysia. The site is underlain predominantly by weathered residual soils, which consist mainly of silty sand. Standard penetration tests (SPT N values in blows/3cm) from borehole result at each test For each of the sacrificial bored piles, two types of instruments, namely, the vibrating wire strain gauges and retrievable vibrating wire etensometers were installed internally in the pile. The strain gauges were installed at si levels with four strain gauges at each level. The Geokon A- retrievable vibrating wire etensometers sensors, housed in a 1mm internal diameter sonic logging pipe was installed at si levels at corresponding strain gauges levels, with 2 sets per level. Piles Structural Properties The instrumented test piles,,, and PTP constructed were all bored cast-in-situ reinforced concrete piles having structural properties as listed in Table 1: 1 1 2 2 3 3 Platform Level Silty SAND Lev. B - - - Clayey - - - - - SILT - - - - - Clayey Silty SAND Soil Profile Lev. A Lev. C Lev. D Lev. E Lev. F Silty SAND PTP 1 (blows/3cm) 1 1 1 13 2 3 21 3 23 21 3 33 3 Legends: (blows/3cm) 1 1 1 2 2 1 3 3 3 3 3 2 2 2 3 PTP 3 VW Strain Gauge ( Nos/Level) GLOSTREXT Anchored Level GLOSTREXT VW Sensor 1 1 (blows/3cm) 1 2 23 1 2 3 1 2 33 1 3 13 3 3 (blows/3cm) 1 1 11 3 11 1 2 2 1 1 21 1 21 33 3 3 2 PTP 1 1 3 11 (blows/3cm) PTP 2 PTP 2 1 DB 3 DB BH DB BH 2 3 1 1 11 3 1 33 3 1 1 N.T.S Fig.3(b) : SPT N values and pile instrumentation scheme for to PTP 3

Paper published in 1 th International Conference on Piling and Deep Foundations, 31 st May 2 nd June, Amsterdam. Table 1:Structural Properties of Piles Test Pile No. Pile Diameter (mm) Pile Length (m) Main Reinforcement Concrete Overbreak. T2 <% 1. T2 <% 1. T2 <%. T <% PTP.1 2T2 <1% Procedures for Installation of Test Piles The bored cast-in-place test piles were ecavated with a Bauer BG heavy-duty rotary drilling rig using an m length temporary casing with bentonite slurry as a stabilizing fluid. Steel reinforcement cage was lowered after base cleaning using cleaning bucket and desanding of bentonite, followed by placing of Grade concrete using tremie method. Loading Arrangement And Test Programmes The instrumented piles were tested by the Maintained Load Test (MLT) using a kentledge reaction system. In the set-up used, the test loads were applied using two 1, tonne capacity hydraulic jacks acting against the main reaction beam. The jacks were operated by an electric pump. The applied loads were measured by calibrated vibrating wire load cells. Static load tests commenced typically 3 weeks after pile installation, with cube strength eceeded specified concrete cube strength of N/mm 2. To obtain good quality data, small load increments were chosen. Typically, increments of 1% of the working load were applied progressively in two loading cycles to a maimum test load of two and a half times the working load or failure, whichever occurs first. Table 2 : Test Programs Pile No. Date Installed Total Loading Period Maimum Test Load 1//3 hours,23 kn //3 1 hours 11, kn 2//3 3 hours, kn 2//3 hours, kn PTP /1/3 hours, kn Pile Movement And Instruments Monitoring System The pile top settlement was monitored using the following instruments: (i) Four Linear Variation Displacement Transducers (LVDTs) mounted to the reference beams with its plungers placed vertically against glass plates fied on the pile top. (ii) Vertical scale rules fied to pile top sighted by a precise level instrument. Vertical scales were also provided on the reference beams to monitor any movement during load testing. The vibrating wire load cells, strain gauges, retrievable etensometers and LVDTs were logged automatically using a Micro-1 Datalogger and Multilogger software, at 3 minutes intervals for close monitoring during loading and unloading steps. Only precise level readings were taken manually. RESULTS AND ASSESSMENT OF PILES PERFORMANCE Load Movement Behaviour Of The Piles The measured pile head load-pile head settlement behaviours, pile head load versus pile toe settlement and the measured pile head load-total shortening behaviours are presented in Figure for to PTP. Shortening readings acquired from measurements of the relative movement of anchored segments across entire pile lengths seemed highly consistent, giving highly reliable pile toe settlement behaviours (derived by subtracting the structural shortening from the pile head settlement ). Aial Load Distribution From VW Strain Gauges The load distribution curves indicating the load distribution along the shaft and at the base were derived from computations based on the measured changes in strain gauge readings and pile properties (steel content, crosssectional areas and concrete modulus) based on as-built details (including concreting record) known from the construction record.

Paper published in 1 th International Conference on Piling and Deep Foundations, 31 st May 2 nd June, Amsterdam. Load transferred (P) at each level is calculated as follows: P = ε (E c *A c + E s *A s ) where ε = average change in strain gauge readings A c = cross-sectional area of concrete E c = Concrete Modulus A s = cross-sectional area of steel reinforcement E s = Young's Modulus of Elasticity in steel ( = 2 kn/mm 2 ) The modulus of concrete, E c was backcalculated with the aid of the strain gauge results at level A and the pile top loads. For each stage of loading, E c is back-calculated by assuming that the load at the strain gauge level A was equal to the applied load at the pile top. Load distribution curves acquired from VW Strain Gauges test results for the test cycle for to PTP are presented in Fig.. Aial Load Distribution From Retrievable VW Etensometers In the GLOSTRET method, the modulus of concrete, E c was back-calculated by measuring the strains in the top 2.m of debonded length of the pile using the GLOSTREXT vw sensors and the pile top loads. For each stage of loading, E c is backcalculated by assuming that the load at the mid-point of the 2.m debonded length level was equal to the applied load at the pile top. Load distribution curves acquired from GLOSTREXT test results for the test cycle for to PTP are plotted and presented in Fig.. It is worthy to note that Fig. and Fig. show very similar characteristics. 3 2 1 1 2 1 2 1 2 1 2 PTP 3 2 1 3 2 1 2 2 1 2 1 2 2 1 2 1 1 2 1 2 1 1 2 2 1 1 2 2 1 2 1 2 1 1 2 2 3 1 1 2 2 3 1 2 1 2 1 1 2 2 PTP 1 1 2 2 PTP 1 2 3 1 2 3 1 1 2 2 1 1 2 2 3 1 1 2 2 Fig.: Pile Head Settlement, Pile Toe Settlement and Total Shortening behaviour, to PTP 1 2 3 2 1 2 1 2 1 2 1 1 1 1 1 1 2 2 3 2 3 2 3 2 3 3 PTP Fig.: Load Distribution Curves computed from vw strain gauges test results for to PTP

Paper published in 1 th International Conference on Piling and Deep Foundations, 31 st May 2 nd June, Amsterdam. 1 2 3 2 1 2 1 2 1 2 1 1 1 1 1 1 2 2 3 2 3 2 3 2 3 3 PTP Fig.: Load Distribution Curves computed from GLOSTREXT test results for to PTP COMPARISON OF RESULTS FROM CONVENTIONAL AND GLOSTREXT METHOD Comparison Of Back Calculated Concrete Modulus Values The plots of back-calculated concrete modulus values, E c, versus measured aial strain at level A from both conventional strain gauges (at 1.m depth) and Global Strain Etensometers (from.m to 2.m depth) for the test cycles for piles are plotted and presented in Fig. (a) to Fig. (e) respectively. 3 3 2 1, VWSG, GloStrEt 1 1 2 2 3 3 Measured Aial Strain at Lev. A ( 1 - ) Fig. (a): E c vs Measured Aial Strain for Test Pile PTP 1 3 3 2 1, VWSG, GloStrEt 1 1 2 2 3 3 3 3 2 1, VWSG, GloStrEt 1 1 2 2 3 3 Measured Aial Strain at Lev. A ( 1 - ) Fig. (c): E c vs Measured Aial Strain for Test Pile PTP 3 3 3 2, VWSG, GloStrEt 1 1 1 2 2 3 3 Measured Aial Strain at Lev. A ( 1 - ) Fig. (d): E c vs Measured Aial Strain for Test Pile PTP 3 3 2 1 PTP, VWSG PTP, GloStrEt 1 1 2 2 3 3 Measured Aial Strain at Lev. A ( 1 - ) Fig. (b): E c vs Measured Aial Strain for Test Pile PTP 2 Measured Aial Strain at Lev. A ( 1 - ) Fig. (e): E c vs Measured Aial Strain for Test Pile PTP

Paper published in 1 th International Conference on Piling and Deep Foundations, 31 st May 2 nd June, Amsterdam. From the plots presented, it is clear that the back-calculated concrete modulus values measured by two independent systems (conventional Strain Gauges and Global Strain Etensometers) agree reasonably well. These plots are also etremely useful to study the correction of E c according to variation of strain level with pile depth, which can further improve the accuracy of the aial load distribution computation using back-calculated E c. Comparison Of Measured Aial Strain Along Pile Shaft The plots of measured aial strain at various levels along pile shaft from both conventional strain gauges and Global Strain Etensometers for piles are presented in Fig.(a) to Fig.(e) respectively. Aial Strain from VWSGs ( 1 - ) 3 3 2 2 1 1 to Lev B Lev C to Lev E Control Line for VWSG=GloStrEt 1 1 2 2 3 3 Aial Strain from GloStrEt ( 1 - ) Fig. (a) : Measured Aial Strain from VWSG vs Aial Strain from GloStrEt for PTP 1 Aial Strain from VWSGs ( 1 - ) 3 3 2 2 1 1 to Lev B Lev C to Lev D Lev D to Lev E Control Line VWSG = GloStrEt 1 1 2 2 3 3 Aial Strain from GloStrEt ( 1 - ) Fig. (b) : Measured Aial Strain from VWSG vs Aial Strain from GloStrEt for PTP 2 Aial Strain Fr VWSGs ( 1 - ) 3 3 2 2 1 1 to Lev B Lev C to Lev D Lev D to Lev E Control Line "VWSG = GloStrEt" 1 1 2 2 3 3 Aial Strain Fr A ( 1 - ) Fig. (c) : Measured Aial Strain from VWSG vs Aial Strain from GloStrEt for PTP 3 Aial Strain from VWSGs ( 1 - ) 3 3 2 2 1 1 to Lev B Lev C to Lev D Lev D to Lev E Control VWSGs=GloStrEt 1 1 2 2 3 3 Aial Strain from GloStrEt ( 1 - ) Fig. (d) : Measured Aial Strain from VWSG vs Aial Strain from GloStrEt for PTP Aial Strain from VWSGs ( 1 - ) 3 3 2 2 1 1 to Lev B Lev C to Lev D Lev D to Lev E Control Line VWSG=GloStrEt 1 1 2 2 3 3 Aial Strain from GloStrEt ( 1 - ) Fig. (e) : Measured Aial Strain from VWSG vs Aial Strain from GloStrEt for PTP

Paper published in 1 th International Conference on Piling and Deep Foundations, 31 st May 2 nd June, Amsterdam. From the plots presented, it is shown that the aial strains measured by the two independent systems are in good agreement. Considering that the Global Strain Etensometers measure strains over an entire section of a pile, thus it integrates the strains over a larger and more representative sample than the conventional strain gauges. References: Bustamante M., Doi B (11) A new model of LPC removable etensometer, Proc. th International Deep Foundation Institute Conference, pp -. Geokon Inc. 1, revised 23. Instruction Manual, Model A- Retrievable Etensometer. CONCLUSIONS The results of five instrumented bored test piles involving full-scale static load tests with both GLOSTREXT method and conventional instrumentation show the following behavior: i) The back-calculated concrete modulus values measured by two independent systems (conventional Strain Gauges and Global Strain Etensometers) agree reasonably well. ii) The aial strains measured by the two independent systems are in good agreement. The Global Strain Etensometers measure strains over an entire section of a pile, thus it integrates the strains over a larger and more representative sample than the conventional strain gauges. iii) Using the global strain etensometers, measurement of the pile shortening over the whole pile length can now be reliably measured in segments. This enables the movement of the pile and strains at various levels down the pile shaft to be determined accurately, thus permitting an improved load transfer distribution of piles in static load tests. The GLOSTREXT method significantly simplifies the instrumentation effort by enabling the sensors to be post-installed after casting of pile. It also minimizes the risk of instruments being damaged during the concreting process. Acknowledgement The authors wish to thank the Public Works Department Malaysia for permission to publish this paper. The authors also wish to thank the Gerbang Selatan Bersepadu Public Works Project Team for their support.