Instrument Calibration at the ESRF

Similar documents
University of Warwick institutional repository: A Thesis Submitted for the Degree of PhD at the University of Warwick

INSTRUMENTATION AND SURVEY NETWORKS AT THE ESRF

Creation of the π angle standard for the flat angle measurements

Upgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory

Part 5: Total stations

A laser metroscope for the calibration of setting rings

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

An Introduction to The Guide to the Expression of Uncertainty in Measurement

Fine Alignment of the ATF Damping Ring

Nanometrology and its role in the development of nanotechnology

David Martin High Precision Beamline Alignment at the ESRF IWAA, Grenoble 3-7 October 2016

High Precision Alignment at the European Synchrotron Radiation Facility

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

3-D METROLOGY APPLIED TO SUPERCONDUCTING DIPOLE MAGNETS FOR LHC

Long Term Site Movements at the ESRF

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

ANNEXE 8. Technical protocols for the interlaboratory comparisons

GNSS CORS Calibration and Testing

Review of Accelerator Alignment

LASER TRAPPING MICRO-PROBE FOR NANO-CMM

The Fundamentals of Moisture Calibration

THE EUROPEAN SYNCHROTRON RADIATION FACILITY HYDROSTATIC LEVELING SYSTEM TWELVE YEARS EXPERIENCE WITH A LARGE SCALE HYDROSTATIC LEVELING SYSTEM

Machine Positioning Uncertainty with Laser Interferometer Feedback

POSITIONING THE SPRING-8 MAGNETS WITH THE LASER TRACKER

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

METROLOGY AND SURVEYING AT CERN : RECENT NEWS AND FACTS

Journal of Machine Engineering, 2018, Vol. 18, No. 3, 78 86

Alignment at the ESRF

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

A Comprehensive Overview of the Laser Based Calibration Facility at Measurement Standards Laboratory

A Rocket Experiment for Measurement Science Education

ISO INTERNATIONAL STANDARD

SURVEY AND ALIGNMENT FOR THE SYNCHROTRON LIGHT SOURCE ELETTRA

Assessment of the impact of the articulated probe head angular orientation on the probe head errors distribution

THE LASER TRACKER : A MAJOR TOOL FOR THE METROLOGY OF THE LHC

Vocabulary of Metrology

Determination of particle size distribution Single particle light interaction methods. Part 4:

custom reticle solutions

DEVELOPMENT OF ANGULAR VELOCITY CALIBRATION FACILITY USING SELF-CALIBRATABLE ROTARY ENCODER

VISA Undulator Fiducialization and Alignment

THE NEW 1.1 MN m TORQUE STANDARD MACHINE OF THE PTB BRAUNSCHWEIG/GERMANY

PC TOOL FOR DATA ANALYSIS IN CALIBRATION OF SPECIAL WEIGHTS

THE GSI FUTURE PROJECT: AN INTERNATIONAL ACCELERATOR FACILITY FOR BEAMS OF IONS AND ANTIPROTONS

UNCERTAINTY IN TACHEOMETRIC MEASUREMENT OF CONVERGENCES IN TUNNELS

COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR FORCE UP TO 1 MN AND TORQUE UP TO 2 KN M

A comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs

A NEW STANDARD METHOD FOR THE SURVEYING AND ALIGNMENT OF BEAMLINE FACILITIES AT GSI

The LHC Dipole Geometry as Built in Industry

CUSTOM RETICLE SOLUTIONS

Development & Performance of Hardness Testing Machine Calibration Processor. Tsukuba, Japan

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Metrology Enhanced Tooling for Aerospace (META): Strategies for Improved Accuracy of Jig Built Structures

Analysis of interlaboratory comparison when the measurements are not normally distributed

Analysis of the influence of the Spherically Mounted Reflector on the measurements done with Laser Tracker

STATUS OF THE WIGOS DEMONSTRATION PROJECTS

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air

MICHELL TECHNOLOGIES FOR MOISTURE. Calibration. General Principles & Theory, Equipment Considerations

CMM Uncertainty Budget

APPLICATIONS OF HYDROSTATIC LEVELING IN CIVIL ENGINEERING

New concept of a 3D-probing system for micro-components

Interferometric Measuring Systems of Nanopositioning and Nanomeasuring Machines

Measurement method for the proficiency testing program

PERFORMANCE OF WIRE POSITION SENSORS IN A RADIATION ENVIRONMENT. CERN, Geneva, Switzerland

Lattice Cell/Girder Assembly

Final Report August 2010

Uncertainty of Calibration. Results in Force Measurements

ITTC Recommended Procedures

Auto collimator. Introduction. Objectives: Apparatus: Theory:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST. Ronaldo Minniti 1 and Ladislav Czap 2

Modelling of a dynamic torque calibration device and determination of model parameters

HLS online monitoring during beam assisted girder re-alignment at the accelerator SLS (Swiss Light Source)

COPYRIGHTED MATERIAL INTRODUCTION CHAPTER 1

A PRELIMINARY ALIGNMENT PLAN FOR RIA AT MSU

This document is a preview generated by EVS

To the best of our knowledge, the FG5 gravimeter represents the current state-of-the-art in the measurement of absolute gravity.

Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

ISO 3741 INTERNATIONAL STANDARD

Introduction to the evaluation of uncertainty

Measurements and Calibration of the stripline BPM for the ELI-NP facility with the stretched wire method

CALIBRATION. Calibration. General Principles & Theory, Equipment Considerations. Copyright Caltech 2014

ISO INTERNATIONAL STANDARD

New 2d Far Field Beam Scanning Device at DLR s Electric Propulsion Test Facility

Guidelines on the Calibration of Static Torque Measuring Devices

Diagnostic testing of the comparator carriage vibrations

Distance Determination between the MINOS Detectors for TOF Measurements. Dr. Virgil Bocean Alignment & Metrology Department Fermilab

Concept and setup of a multi-component facility for force and torque in the range of 1 MN and 2 kn m

Tutorials. 1. Autocollimator. Angle Dekkor. General

Dimensional metrology and positioning operations: basics for a spatial layout analysis of measurement systems

Part 2: Methods for special reverberation test rooms

THE NEW WATT BALANCE EXPERIMENT AT METAS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

STATISTICAL PROCESS CONTROL - THE IMPORTANCE OF USING CALIBRATED MEASUREMENT EQUIPMENT. CASE STUDY

Interferometer for Squareness measurement

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI. DEPARTMENT OF MECHANICAL ENGINEERING FAQ

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Introduction to Fourier Transform Infrared Spectroscopy

R SANAS Page 1 of 7

Dimension measurement. By Mr.Vuttichai Sittiarttakorn

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

Transcription:

Instrument Calibration at the ESRF David MARTIN, France Key words: calibration, laser tracker, theodolite, total station SUMMARY The European Synchrotron Radiation Facility (ESRF) is an accelerator laboratory located in Grenoble France. It is a joint facility supported and shared by 18 European countries. The ESRF operates the most powerful synchrotron radiation source in Europe. Each year several thousand researchers travel to Grenoble where they work in a first-class scientific environment to conduct exciting experiments at the cutting edge of modern science. The ALignment and GEodesy (ALGE) group is responsible for the installation, control and periodic realignment of the accelerators and experiments at the ESRF. Alignment tolerances are typically less than one millimetre and often in the order of several micrometers over the approximate 1 km accelerator network. Typically, least squares survey network calculations give distance and angle residual standard deviations of 0.1 mm and 0.5 arc second respectively. The semi-major axis of the absolute error ellipses are less than 0.15 mm at the 95% confidence level. To help obtain these results, the ESRF has and continues to develop calibration techniques for high precision Robotic Total Stations (RTSs) and Laser Trackers (LTs). Electronic Distance Meters (EDM) incorporated into RTSs and Interferometric and Absolute Distance Meters (IFMs and ADMs) used in LT instruments are calibrated on the 50 m long Distancemeter Calibration Bench (DCB). Recently two instrument standards, the Horizontal Circle Comparator (HCC) and the Vertical Circle Comparator (VCC), were developed to calibrate horizontal and vertical angles measured by RTS and LT instruments. These three instrument standards are accredited by COFRAC 1 under the ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories standard.[1] This paper will present these standards and calibration results of LT and RTS instruments calibrated on them. 1 The HCC and VCC are in the process of final COFRAC accreditation. 1/11

Instrument Calibration at the ESRF David MARTIN, France 1. INTRODUCTION Robotic Total Stations (RTSs) 2 and Laser Trackers (LTs) are used extensively in large scale metrology (LSM). They determine three dimensional coordinates of a point by measuring two orthogonal angles (nominally horizontal and vertical) and a distance to a corner cube reflector; typically a spherically mounted retro-reflector (SMR). LSM covers fields that require very high precision alignment over relatively large areas and volumes. Examples of LSM include particle accelerator alignment and aircraft, ship and car manufacture. [2, 3] The field of particle accelerator alignment is unique in so far as it overlaps both the fields of metrology and traditional surveying and geodesy. Standard measurement precision is typically sub-millimetric over distances ranging between several hundred metres up to nearly 30 km. Extremely specialised techniques and instruments are needed to guarantee that these requirements can be met. [4, 5] 2. ALIGNMENT AND CALIBRATION AT THE ESRF For the ESRF accelerators and beam lines to work correctly, alignment is of critical importance. The ESRF ALignment and GEodesy (ALGE) group is responsible for the installation, control and periodic realignment of the accelerators and experiments. Alignment tolerances are typically less than one millimetre and often in the order of several micrometers. Distance and angle residual standard deviations issued from the 842 metre long accelerator network are in the order of 0.1 mm and 0.5 arc-seconds respectively. Absolute error ellipses are smaller than 0.15 mm at the 95% confidence level. [6] To help obtain these results, the ESRF has and continues to develop calibration techniques for high precision motorized RTS instruments. This type of instrument is the workhorse for all precision work made at the ESRF. At present, the ESRF Alignment and Geodesy group provides a full calibration suite for the calibration of distances and angles issued from RTSs and LTs. Distances are calibrated on the Distance Meter Calibration Bench (DCB). Horizontal angles are calibrated using the Horizontal Circle Comparator (HCC), and vertical angles are calibrated against the Vertical Angle Comparator (VCC).[7] 2 Robotic Total Stations are total stations (i.e. a theodolite with an integrated distance meter) equipped with an automatic target recognition (ATR) system. They provide a degree of remote control of the instrument. For example, a survey operator can control the RTS from a distance using a wireless radio device. The operator holds the reflector and controls the total station from the observed point. At the ESRF, the RTS is controlled from a laptop computer to follow a pre-programmed measurements series. 2/11

2.1 The Distance Meter Calibration Bench At the ESRF, distances are calibrated against the 52 m long DCB (refer to Figure 1). Since February 2001, this bench has been accredited under ISO/IEC 17025 for the calibration of EDM s by COFRAC, (COmité FRançais pour l'accréditation) the French National accreditation body. An accredited interferometer is installed on a fixed pillar at one end of the bench and the instrument to be measured (RTS or LT) is installed on a fixed pillar or heavy tripod at the other end. The interferometer and instrument reflector are installed on a servo-controlled carriage. A calibration is made by first determining the zero error of the instrument reflector pair and then by moving the servo-carriage along the bench and comparing the displacements measured by the RTS or LT and the interferometer. Figure 1 Schematic of the ESRF calibration bench. Zoom a) is the instrument station; zoom b) the servo carriage with the instrument and interferometer reflectors and zoom c) the interferometer station. After the zero error has been determined the servo carriage is moved in 10 cm intervals from 2 m to 50 m to determine the instrument cyclic (bias) error. The bench is equipped with an accredited meteorological station which measures temperature, pressure and humidity. Additional temperature sensors are installed at regular intervals along the length of the bench to improve corrections for the variations in refraction along the line of sight. EDM calibrations can be made between 1.9 and 50 m with an expanded uncertainty 3 ( k = 2) of 0.07 mm + 0.76q ; and from 1.9 to 113 m with and expanded uncertainty of 0.10 mm + 0.74q. Here, q is the instrument resolution. It is 0.1 mm in the case of the 3 The notion of expanded uncertainty is discussed in the Guide to the Expression of uncertainty in Measurement (GUM). 3/11

RTSs used at the ESRF. Therefore the expanded uncertainty for 50 m and 113 m calibrations are 0.15 mm and 0.17 mm respectively. In 2006 the ESRF accreditation was extended to laser k = 2 for the calibration of LT absolute distance meters (ADMs) trackers. The uncertainty ( ) and interferometric distance meters (IFMs) over the range of 0.2 m to 48.2 m is 42 µm. [8-11] 2.2 The Horizontal Circle Comparator At the ESRF, horizontal angles are calibrated against the HCC (refer to Figure 2). The HCC is composed of a reference plateau, a rotation table, and an angle acquisition system. The angle acquisition system is referred to as the Linked Encoders Configuration (LEC). The reference plateau is fixed on the rotation table and rotates with it. The LEC is incorporated into the rotation stage. Figure 2 Schematic of the HCC assembly showing reference plateau e), the rotation table f) and the linked encoders configuration (LEC) a), b), c), and d). The principal HCC movement is rotation about the main Z axis. However movements with the other five degrees of freedom are unavoidable. Twenty mm wide edges around the circumference of the plateau are high machined surfaces, shown at g) in Figure 2, that act as targets for capacitive probes used to determine the plateau x, y and z translation movements and rotations about the X and Y axes. The correction of these unwanted movements is important in the resolution of errors inherent to the HCC. The RTS and LT horizontal circle calibration procedure consists of installing the instrument on the reference plateau; placing its SMR on a fixed socket located at nominal distance from the instrument and observing horizontal angles. After each angle observation, the HCC is turned through an angleθ HCC ; the instrument being calibrated is rotated back through the 4/11

same nominal angle θ RTS, and the observation procedure is repeated. The calibration consists of comparing the differences between the HCC angle readings and RTS or LT horizontal circle observations. The procedure is illustrated in Figure 3. Any angle displacement over 360 degrees can be investigated. Figure 3 Observation procedure using the HCC. 2.3 The Linked Encoders Configuration The HCC angle reference system is the LEC (Figure 2). The LEC consists of two Heidenhain RON 905 angle encoders mounted in juxtaposition. The body of one RON 905 is fixed to the main support assembly and does not move. The body of the second RON 905 is fixed to the main plateau and rotates with it. The two RON 905 encoders (rotors) are rigidly connected together in a precision alignment shaft assembly. The shaft and encoders are rotated continuously by a high-performance precision rotation stage (shown c) in Figure 2). The two RON 905 encoder positions are read out simultaneously and continuously. The LEC is used to reduce the influence of residual RON 905 encoder errors. [12-15] Comparative small angle tests made between the LEC and high precision capacitive probes measuring rotational movements of a 1 m long bar show that the LEC uncertainty remains below 0.05 arc seconds. The HCC has been examined by COFRAC and is awaiting final accreditation. The expanded k = 2 for HCC calibrations of RTS and LT horizontal circles is 1 arc second. 4 uncertainty ( ) 2.4 The VCC 4 As part of the accreditation procedure, an inter-laboratory comparison between the ESRF and the French National Metrology Institute, the Laboratoire National d'essais (LNE) using a 12 sided polygon mirror was made. Values were compared using expanded uncertainty given in the GUM. E numbers. The maximum n E number was determined to be 0.44. Values n of E < 1 provide objective evidence that the estimate of uncertainty is consistent with the definition of n 5/11

The VCC is composed of a motorized 2.5 m long linear motion guide with carriage fixed to a 3 m aluminium structural rail and an interferometer system (refer to Figure 4). The interferometer system is positioned at one end of the rail while the motorisation driving the carriage is at the opposite end. Its reflector is placed on the carriage. The full system is placed on a heavy duty adjustable height stand. The VCC system is interfaced to the stand with a system which permits it to be rotated in any orientation. When the VCC, a multipurpose tool, is oriented vertically it can be used to calibrate the vertical circles of RTSs and LTs. Whereas it is important to examine the horizontal circle over the full 360, this constraint is generally relaxed with vertical circles. First, no instrument available on the market is capable of observing a target directly over the full 360 vertical circle. For example its base prevents it from reading angles between approximately 150 and 210. Often taking vertical readings near the zenith (i.e. 0º) is difficult as well. For the most part, the typical working range of the vertical circle of LTs and RTSs is within ±45 of the horizontal (i.e. vertical circle readings of 90 ±45 and 270 ±45 ). The VCC calibration procedure compares the SMS vertical circle readings with the vertical displacements of its SMR. These vertical displacements are measured by the interferometer system installed on the VCC. The determination of the vertical reference angle requires the simultaneous measurement of the distance between the instrument being calibrated and the VCC. Provided that the instrument (RTS or LT) distance meter is calibrated on the ESRF DCB, these distances are traceable with an assigned uncertainty and coverage factor. The VCC has been examined by COFRAC and is awaiting final accreditation. The expanded k = 2 for VCC calibrations of RTS and LT horizontal circles is uncertainty ( ) 1.65 arc seconds. 6/11

3. CALIBRATION RESULTS Figure 4 Schematic of the VCC assembly. Figure 5, Figure 6 and Figure 7 show characteristic results of calibrations made using the DCB, the HCC and the VCC respectively. All results show the difference between the distance or angle measured by the instrument being calibrated (i.e. LT or RTS) and the distance or angle determined using the DCB, HCC and VCC standards (i.e xmeas xref ). These calibrations ensure that all measurements taken with instruments calibrated at the ESRF are traceable to the metre. 5 [16] 5 Note that the radian, the official SI unit for angle, is a dimensionless unit defined using the metre as m m 1. 7/11

Figure 5 Typical IFM, ADM and EDM distance error curves derived from calibrations made on the ESRF DCB. The ADM and IFM curves are from three different instruments and manufacturers. The expanded uncertainties ( 2) k = for these calibration curves are 0.042 mm for the IFM and ADM curves and 0.15 mm for the EDM curve. Figure 6 Results of a LT calibration made on the HCC. The heavy red line is a model for the horizontal angles issued from a LT. The RMSE of this model is 1.07 arc seconds. The expanded uncertainty ( k = 2) for this calibration curve is 1.0 arc seconds 8/11

Figure 7 Results of a LT calibration made on the VCC. The expanded uncertainty ( k = 2) for this calibration curve is 1.65 arc seconds 4. CONCLUSION This paper has presented three instrument standards developed at the ESRF used to calibrate the distances, and the vertical and horizontal angle readings issued from RTSs and LTs. The main reason for the development of these standards has been to provide assurance in, and ultimately improve the quality of measurements made on the ESRF survey networks. The improvement of measurement quality is achieved by developing mathematical models through calibration to compensate distance, and horizontal and vertical angle systematic reading errors. All three of these standards have been, or in the case of the HCC and VCC are in the final process of being accredited under the ISO/CEI 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories standard.[1] This ensures that all measurements issued from instruments calibrated at the ESRF are traceable to the metre. 9/11

REFERENCES 1. ISO, ISO/CEI 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories. Second edition ed. 2005: International Organization for Standardization. 2. Estler, W.T., et al., Large-scale metrology - An update. CIRP Annals Manufacturing Technology 2002. 51(2): p. 587-609. 3. Peggs, G.N., et al., Recent Developments in Large Scale Dimensional Metrology. Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture 2009. 223(6): p. 571-595. 4. Mayoud, M. Large Scale Metrology for Research and Industry Application to Particle Accelerators and Recent Developments. in FIG Working Week 2004 2004. Athens: FIG. 5. Martin, D. Review of Accelerator Alignment. in XXIV FIG International Congress. 2010. Sydney, Australia. 6. Martin, D. Instrumentation and Survey Networks at the ESRF. in Eighth International Workshop on Accelerator Alignment. 2004. CERN, Geneva Switzerland. 7. Martin, D. and D. Chetwynd. Angle calibration of robotic total stations and laser trackers. in XIX IMEKO World Congress: Fundamental and Applied Metrology. 2009. Lisbon, Portugal: IMEKO. 8. Martin, D., A Modern Calibration Bench: Calibrating Survey Instruments. GIM International, 2007. 21(8): p. 21-23. 9. COFRAC. ANNEXE TECHNIQUE à l'attestation d'accréditation (convention n 1 343) Norme NF EN ISO/CEI 17025 v2005. 2008 Available from: www.cofrac.fr. 10. Martin, D. Calibration of Total Stations Instruments at the ESRF. in XXIII FIG International Congress. 2006. Munich, Germany. 11. JCGM, ed. Evaluation of measurement data Guide to the expression of uncertainty in measurement. ed. J.C.f.G.i. Metrology. 2008, BIPM: Sèvres. 12. Palmer, E.W., Goniometer with Continuously Rotating Gratings for Use as an Angle Standard. Precision Engineering-Journal of the American Society for Precision Engineering, 1988. 10(3): p. 147-152. 13. Leleu, S., J.M. David, and G.P. Vailleau. La Mesure des Angles au BNM-LNE - Cretion d'une Nouvelle Reference de Mesure Angulaire. in Congrès International de Métrologie 2005. 2003. Toulon. 14. Martin, D. The Analysis of Parasitic Movements on a High Precision Rotation Table. in MEDSI 2006. 2006. Himeji Japan. 15. Martin, D. and D. Chetwynd. High precision angle calibration of robotic total stations and laser trackers. in 5th International Symposium on Instrumentation Science and Technology. 2008. Shenyang, China. 16. BIPM, The International System of Units (SI). 2006, Comité International des Poids et Mesures BIOGRAPHICAL NOTES David Martin is head of the ESRF Alignment and Geodesy Group. He holds an MSc in Land Surveying from the Department of Geomatic Engineering, University College London and a PhD in Engineering from the University of Warwick in the United Kingdom. He is the chair of FIG Standards Network and FIG Working Group 5.1 Standards, Quality Assurance and Calibration. He has published a number of papers concerning accelerator alignment, survey instrument calibration and hydrostatic levelling systems. CONTACTS David Martin European Synchrotron Radiation Facility BP220, 38043 Grenoble CEDEX 9 FRANCE 10/11

Email: martin@esrf.fr Web site: http://www.esrf.eu 11/11