arxiv: v1 [astro-ph.im] 1 May 2009

Similar documents
The Galway Astronomical Stokes Polarimeter: An All-Stokes Optical Polarimeter with Ultra-High Time Resolution.

Provided by the author(s) and NUI Galway in accordance with publisher policies. Please cite the published version when available.

INTEGRAL observations of -ray polarized sources

Stokes polarimeter optimization in the presence of shot and Gaussian noise

PoS(ISKAF2010)083. FRATs: a real-time search for Fast Radio Transients with LOFAR

linear polarization: the electric field is oriented in a single direction circular polarization: the electric field vector rotates

Lecture 4: Polarimetry 2. Polarizers and Retarders. Polarimeters. Scattering Polarization. Zeeman Effect. Outline

The Crab Optical/X/gamma-ray polarisation processes

Calibration of an Ultra-High Accuracy Polarimeter at the Part-Per-Million Level

Polarization with Interferometry. Michael Ireland

Recent Radio Observations of Pulsars

Lecture 8: Polarimetry 2. Polarizers and Retarders. Polarimeters. Scattering Polarization. Zeeman Effect. Outline

Pulsar Polarimetry. Roberto P. Mignani. INAF-Istituto di Astrofisica Spaziale, Milan (Italy) Kepler Institute of Astronomy, Zielona Gora (Poland)

Optical pulsations of the Crab nebula pulsar with AquEYE

arxiv: v2 [astro-ph.he] 31 Aug 2017

A New Model for the Beams of Radio Pulsars

arxiv: v1 [astro-ph.sr] 27 Jun 2012

Ellipsometry. Introduction. Measurement Principles

Development of a Dedicated Hard X-Ray Polarimeter Mark L. McConnell, James R. Ledoux, John R. Macri, and James M. Ryan

Spectropolarimetry for EJSM

Polarimetry Techniques. K. Sankarasubramanian ISRO Satellite Centre Bangalore India

Non-thermal emission from pulsars experimental status and prospects

Coherent Superposition of Mueller-Jones States: Synthesizing Mueller Matrices with an Ellipsometer

Transient radio bursts from rotating neutron stars

Single-shot measurement of free-electron laser polarization at SDUV-FEL

Polarized Light. Second Edition, Revised and Expanded. Dennis Goldstein Air Force Research Laboratory Eglin Air Force Base, Florida, U.S.A.

THE HIGH TIME RESOLUTION UNIVERSE. A survey for pulsars & fast transients

Observing transients with LOFAR and AARTFAAC

Pulsars & Double Pulsars:! A Multiwavelength Approach!

The Galaxy Viewed at Very Short Time-Scales with the Berkeley Visible Image Tube (BVIT)

arxiv: v1 [astro-ph] 14 Jul 2008

arxiv:astro-ph/ v1 10 Nov 1999

The Parkes Multibeam Pulsar Survey - III. Young Pulsars and the Discovery and Timing of 200 Pulsars

PoS(FRAPWS2014)015. The Pulsar in the Crab Nebula

arxiv: v1 [astro-ph.sr] 18 Oct 2012

SPARC4 Simultaneous Polarimeter and Rapid Camera in 4 bands

GRB Polarimetry with POLAR. Merlin Kole

Timing Noise and The Long-term Stability of Pulsar Profiles

Pulsars. Table of Contents. Introduction

Unambiguous Black Hole Mass from Polarimetry and Application to Hot Jupiters

First Results of POLAR: A dedicated Gamma-Ray Burst Polarimeter

Polarised Light. Evan Sheridan, Chris Kervick, Tom Power October

G.Witzel Physics and Astronomy Department, University of California, Los Angeles, CA , USA

Transient Cosmic Phenomena and their Influence on the Design of the SKA Radio Telescope

arxiv: v1 [astro-ph.im] 3 Feb 2015

First observations of the second solar spectrum with spatial resolution at the Lunette Jean Rösch

LIGO Status and Advanced LIGO Plans. Barry C Barish OSTP 1-Dec-04

3.4 Elliptical Parameters of the Polarization Ellipse References

Lecture 6: Polarimetry 2. Polarizers and Retarders. Polarimeters. Scattering Polarization. Zeeman Effect. Hanle Effect. Outline

arxiv: v1 [astro-ph.ga] 22 Dec 2009

Drifting2 or Analysis of temporal evolution of drifting subpulse phenomenon

Lecture 5: Polarization. Polarized Light in the Universe. Descriptions of Polarized Light. Polarizers. Retarders. Outline

Recent improvement of the LHD Thomson scattering system

A pulsar wind nebula associated with PSR J as the powering source of TeV J

X-ray polarimetry and new prospects in high-energy astrophysics

Thin Solid Films 519 (2011) Contents lists available at ScienceDirect. Thin Solid Films. journal homepage:

Gravity with the SKA

Fermi-LAT Recent Results on Gamma-Ray Bursts

White Rose Research Online URL for this paper: Version: Accepted Version

Discovery of a New Gamma-Ray Binary: 1FGL J

Polarimetry. Dave McConnell, CASS Radio Astronomy School, Narrabri 30 September kpc. 8.5 GHz B-vectors Perley & Carilli (1996)

PoS(Extremesky 2011)067

Discovery of fast radio transients at very low frequencies

E. Caroli(1), R. M. Curado da Silva(2), J.B. Stephen(1), F. Frontera(1,3), A. Pisa (3), S. Del Sordo (4)

THE PARKES MULTIBEAM PULSAR SURVEY

Prospects for joint transient searches with LOFAR and the LSC/Virgo gravitational wave interferometers

Radio Aspects of the Transient Universe

Spectropolarimetry for Earth observations: a novel method for characterisation of aerosols and clouds

Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts

VERITAS Design. Vladimir Vassiliev Whipple Observatory Harvard-Smithsonian CfA

PoS(extremesky2009)103

FLUX DENSITIES AND RADIO POLARIZATION CHARACTERISTICS OF TWO VELA-LIKE PULSARS

Cosmic Gamma-ray Bursts Studies with Ioffe Institute Konus Experiments

arxiv:astro-ph/ v1 16 Oct 2003

Degree of polarization in laser speckles from turbid media: Implications in tissue optics

Two Space High Energy Astrophysics Missions of China: POLAR & HXMT

GRAINE project: Cosmic Gamma-ray Observation by Balloon-Borne Telescope with Nuclear Emulsion

Problem Solving. radians. 180 radians Stars & Elementary Astrophysics: Introduction Press F1 for Help 41. f s. picture. equation.

Swinburne Research Bank

FUNDAMENTALS OF POLARIZED LIGHT

The Pennsylvania Polarimeters

Linear and circular polarization in GRB afterglows

Testing Gravity and Extreme Physics with Pulsars

The pulsar population and PSR/FRB searches with MeerKAT Slow boring pulsars

Brewster Angle and Total Internal Reflection

SUPPLEMENTARY INFORMATION

A SEARCH FOR FAST RADIO BURSTS WITH THE GBNCC SURVEY. PRAGYA CHAWLA McGill University (On Behalf of the GBNCC Collaboration)

arxiv: v2 [astro-ph.he] 14 Feb 2018

Dynamic Response of a fast near infra-red Mueller matrix ellipsometer. Lars M. S. Aas, Pål G. Ellingsen, Morten Kildemo and Mikael Lindgren

PoS(SSC2015)051. Multi-tomography of polars from SALT spectroscopy

Discovery of a transitional Redback millisecond pulsar J !

GRAPE A Balloon-Borne Gamma-Ray Polarimeter

Lab #13: Polarization

Using Multilayer Optics to Measure X-ray Polarization. Herman L. Marshall (MIT CSR) and E. Silver, H. Schnopper, S. Murray (SAO), M.

The annular gap model: radio and Gamma-ray emission of pulsars. Qiao,G.J. Dept. of Astronomy, Peking Univ.

RoboPol: optical polarimetry in Crete. P. Reig (Foundation for Research & Technology-Hellas) on behalf of the RoboPol collaboration

Observations of Gamma ray Spiders with the Fermi Large Area Telescope

PMARIZED LI6HT FUNDAMENTALS AND APPLICATIONS EBWABD COLLETT. Measurement Concepts, Inc. Colts Neck, New Jersey

POLARIZATION OF LIGHT

Chapter 2 Advanced Mueller Ellipsometry Instrumentation and Data Analysis

Transcription:

GASP - Galway Astronomical Stokes Polarimeter arxiv:0905.0084v1 [astro-ph.im] 1 May 2009 Patrick P. Collins E-mail: p.collins1@nuigalway.ie Brendan Shehan E-mail: bshehan-nuig@yahoo.com Michael Redfern E-mail: mike.redfern@nuigalway.ie Andrew Shearer E-mail: andy.shearer@nuigalway.ie The Galway Astronomical Stokes Polarimeter (GASP) is an ultra-high-speed, full Stokes, astronomical imaging polarimeter based upon a Division of Amplitude Polarimeter. It has been developed to resolve extremely rapid stochastic ( ms) variations in objects such as optical pulsars, RRATs and magnetic cataclysmic variables. GASP has no moving parts or modulated components, so the complete Stokes vector can be measured from just one exposure - making it unique to astronomy. Furthermore the time required for the determination of the full Stokes vector is limited only by the time resolution of the detectors used and the incident photon fluxes. GASP utilizes a modified Fresnel rhomb, which acts as a highly achromatic quarter wave plate and a beamsplitter (referred to as an RBS). Here we present a description of how the DOAP works, some of the optical designs for the polarimeter, and give some preliminary results. Calibration is an important, and difficult issue with all polarimeters, but particularly in astronomical polarimeters. We give a description of calibration techniques appropriate to this type of polarimeter, particularly the Eigenvalue Calibration Method of Compain & Drevillon Polarimetry days in Rome: Crab status, theory and prospects October 16-17 2008 Rome, Italy c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/

1. Introduction Optical polarimetry, traditionally relies upon elements such as rotating half-wave plates and Wollaston prisms to determine the polarisation. Such a methodology works for objects which exhibit polarisation that is static, slowly changing or has well defined periodic behavior. Normal emission from optical pulsars clearly falls into this category, but stochastic phenomena - such as the optical counterpart to giant radio emission [7] or rotating radio transient (RRAT) emission [6] - present a difficult problem for polarimetry. Photo-polarimeters, among the fastest polarimeters, can obtain Stokes I, Q, and U in µs but this may still not be fast enough for stochastic phenomna. GASP is designed to address this problem by measuring simultaneously all Stokes vectors and thereby enabling a determination of both linear and circular polarisation in a single exposure. Similar considerations can be given to studies of other stochastic phenomena such as flickering associated with CVs. Most importantly, GASP will be in position for target of opportunity investigations such as polarisation measurements of the afterglow of gamma ray bursts and searches for the optical counterparts of new gamma-ray pulsars which will be discovered by the Fermi GRO. In this paper we describe the design criteria for the polarimeter. 2. Division of Amplitude Polarimetry (DOAP) DOAP (see Azzam [2]) can measure the entire Stokes vector instantaneously. This is achieved by splitting the incoming light across a specially coated beamsplitter to divide the light to linear and circular components, then onto a polarizing beam splitter, normally a Wollaston prism. As a result, four beams of different intensities will relate linearly to the input Stokes vector as follows, I=AS where I is a 4 1 intensity vector, A is a 4 4 matrix for the system and S is the input vector retrieved from S=IA 1. Only the photon fluxes and time-resolution of the detector used will limit the temporal resolution of the Stokes vector obtained. (a) Original DOAP from Azzam [2] (b) An early polarimeter design following developments of the Compain[4] polarimeter Figure 1: One of the optical designs where the Wollaston splits the light immediately after the RBS and each field has its own optics onto the imager. 2

Figure 2: Schematic optical layout for the GASP Compain & Drevillon [4] describe a DOAP in which a modified Fresnel rhomb, similar to that in Fig 1(b) and 2, is used. We have based the Galway Astronomical Stokes Polarimeter (GASP) upon this design. The prism is designed to act as a highly achromatic quarter wave plate (QWP) and a retarding beamsplitter (RBS). Particular attention was paid to the design of this prism as the optomisation of the system matrix is best when the intensity of both reflected and transmitted beams are equal. Utilizing Snells law, and the prism geometry and the equation for calculating the retardance induced by internal reflection (see Born and Wolf [3]) the prism angle (χ) can be solved. The prism angle (χ) is designed to yield a total quarter wave redardance for two internal reflections(φ 2 ). At the same time the angle of incidence, φ 1, is such that both reflected and transmitted beams are of equal intensity. When each beam is passed through a Wollaston prism these beams are split into two further polarisation states. The resulting four beams are re-imaged enabling their intensities to be extracted and consequently we can determine the full polarimetric characterisation of the input beam. 3. Optical Design Fig 2. Shows the schematic design diagram for GASP. The incoming beam is split three ways with two used for polarimetry and the third, the extracted waste light, for guidance and finding. A Wollaston prism is used to split the two polarimetric channels and each individual beam is picked off to either four individual APD modules or two EMCCD detectors. The overall quantum efficiency (DQE) of each beam is 8-12% with the higher number being for the EMCCD system and the lower for the APDs. 3

4. Calibration Polarimeters are among the hardest instruments to calibrate in astronomy. Normally the instrumental polarization is determined and is subtracted from the data. This means that the polarimeter must be designed to have the analyser as soon as possible in the light path as other elements may depolarize the input. GASP works by purposely polarizing the light before the analysers so a different calibration method is used. A Polarization State Generator (PSG) Generates four linearly independent, optimized [1, 5], Stokes vectors which are measured in the lab. The PSG vectors are passed through the system and four respective intensity vectors are recorded. The system matrix, A, is calculated by A=IW 1. Where W and I are 4 4 matrices formed by the 4 PSG and intensity vectors respectively. No instrumental polarization will exist as this is a total polarimeter and this has been calibrated out. The calibration is verified by measuring polarization and zero polarization standard stars. 4.1 ECM Calibtation Calibration of the polarimeter is achieved through the Eigenvalue Calibration Method (ECM) [5]. All one has to do is measure the Mueller matrices of 4 known high quality samples, Air, a polarizer at 0 and 90 and a QWP at 28. Eigenvalues analysis of the 4 Mueller matrices a linear mapping algorithm, unambiguously determines the error correction matrices for A and W. The ECM method achieves 1% accuracy, consequently the polarimeter can then measure polarization with similar accuracy. 5. Current Progress GASP has been tested on the 1.5m Cassini telescope at Loiano Observatory, Bologna. Here we show the results on two standards - one a 50% polarised source CRL 2688 and the other an unpolarised standard - BD+32 3739. Fig 3 shows an instrument rotation test where we show the measured angle of polarisation as a function of instrument orientation with respect to parallactic angle on the sky. Fig 4 shows the the measured intensities of both sources again as a function of relative instrument orientation. The significance of this test is that under rotation the degree of linear polarisation should remain constant whilst the angle of polarisation should vary precisely with the rotation angle, even though each of the four output beams will vary sinusoidally. This is demonstrated in upper two panels, thus proving that the A matrix can be correctly calibrated to allow accurate inversion of the I vector, yielding the S vector for individual frames. The fluctuations in Stokes I and U/Q were consistent with our model for the propagation of Poisson noise. Fig f3 shows the determined degree of polarisation for a series of 0.1 s exposures of CRL 2688 using the Cassini telescope. This will be equivalent to a 5 ms exposures of the Crab pulsar on a 8m class telescope. 6. Acknowledgements Alexander Goncharov, Nicholas Devaney, Chris Dainty, David Lara, from NUI, Galway s Applied Optics group are thanked for their contribution and assistance. PC thanks SFI and the NUI 4

Figure 3: Polarization angle versus field rotation for the rotation test of a polarised source. Figure 4: Raw channel outputs (ch1 and ch2) for the rotation test of a polarised (CRL 2688) and unpolarised (BD+32 3739) sources. Galway Fellowship programme for their financial assistance. Science Foundation Ireland, who supported the development of GASP under grant 05/RFP/PHY0045 Antonello de Martino, for advice and support and for the loan of equipment including the original Compain & Drevillon RBS References [1] R. Azzam, I. Elminyawi, and A. M. El-Saba. General analysis and optimization of the four-detector photopolarimeter. Journal of the Optical Society of America A, 5:681 689, May 1988. [2] R. M. A. Azzam. Division-of-amplitude photopolarimeter (doap) for the simultaneous measurement of all four stokes parameters of light. Optica Acta, 29(5):685 689, 1982. 5

Figure 5: Degree of polarization versus time for CRL2688 showing the noise characteristics of the series with 0.1 s exposures [3] M. Born and E. Wolf. Principles of Optics, Pergamon Oxford, 1970 [4] E. Compain and B. Drevillon. Broadband division-of-amplitude polarimeter based on uncoated prisms. Applied Optics, 37:5938 5944, 1998. [5] E. Compain, S. Poirier, and B. Drevillon. General and self-consistent method for the calibration of polarization modulators, polarimeters, and mueller-matrix ellipsometers. Applied Optics, 38:3490 3502, 1999. [6] M. A. McLaughlin, A. G. Lyne, D. R. Lorimer, M. Kramer, A. J. Faulkner, R. N. Manchester, J. M. Cordes, F. Camilo, A. Possenti, I. H. Stairs, G. Hobbs, N. D Amico, M. Burgay, and J. T. O Brien. Transient radio bursts from rotating neutron stars. Nature, 439, 820, 2006 [7] A. Shearer, B. Stappers, P. O Connor, A. Golden, R. Strom, M. Redfern and O. Ryan. Enhanced optical emission during Crab giant radio pulses. Science, 301, 493-495, 2003 6