Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

Similar documents
Fast Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon PIN Diodes and APDs

INORGANIC crystal scintillators are widely used in high

Forward Calorimetry Ideas

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

First Look on Radiation Induced Photocurrent in LYSO+SiPM Package

LSO/LYSO Crystal Development Ren-yuan Zhu

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

BSO Crystals for the HHCAL Detector Concept

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Crystals for the HHCAL Detector Concept Rihua Mao, Member, IEEE, Liyuan Zhang, Member, IEEE, and Ren-Yuan Zhu, Senior Member, IEEE

REVIEW OF CRYSTAL CALORIMETERS

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

Development of a Silicon PIN Diode X-Ray Detector

Large Size LYSO Crystals for Future High Energy Physics Experiments

He-3 Neutron Detectors

Precision Crystal Calorimetry in High Energy Physics

THE main physics motivation for building the Compact

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

A Study on Radiation Damage in PWO-II Crystals

Calorimeter test-beam results with APDs

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

arxiv: v2 [physics.ins-det] 8 Feb 2013

Test setup, APDs,, preamps Calibration procedure Gain monitoring with LED Beam test results Future R&D options

Quality Assurance. Purity control. Polycrystalline Ingots

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

IN the last decade, cerium doped silicate based heavy

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

M. De Napoli, F. Giacoppo, G. Raciti, E. Rapisarda, C. Sfienti. Laboratori Nazionali del Sud (LNS) INFN University of Catania. IPRD Oct.

HIGH-PRESSURE HELIUM-3 SCINTILLATION POSITION-SENSITIVE DETECTOR OF THERMAL NEUTRONS

Readout of LYSO using a new silicon photodetector for positron emission tomography

Performance of a Si PIN photodiode at low temperatures and in high magnetic fields

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Precision Crystal Calorimetry in High Energy Physics: Past, Present and Future

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Key words: avalanche photodiode, soft X-ray detector, scintillation γ-ray detector, imaging device PACS: 07.85;95.55.A;85.60.D

Study of pure CsI crystal coupling with APD. The University of Tokyo. Yi-Fan JIN

Characteristics of the Large-Area Stacked Microstructured Semiconductor Neutron Detector

Alpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal

LAAPD Performance Measurements in Liquid Xenon

Factors Affecting Detector Performance Goals and Alternative Photo-detectors

Chapter 4 Scintillation Detectors

Deposited on: 20 December 2010

The GEM scintillation in He-CF 4, Ar-CF 4, Ar-TEA and Xe-TEA mixtures

Validation of Geant4 Physics Models Using Collision Data from the LHC

Application of large-area avalanche photodiodes to energy-dispersive x-ray fluorescence analysis

Energy calibration of the threshold of Medipix for ATLAS

InAs avalanche photodiodes as X-ray detectors

The CMS ECAL Laser Monitoring System

Introduction to Radiation Monitoring

1. Introduction. Etim I.P. 1, William E. S. 2, Ekwe S.O. 3. Licensed Under Creative Commons Attribution CC BY

Characterization and Monte Carlo simulations for a CLYC detector

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

Study of a scintillation counter consisting of a pure CsI crystal and APD

Alpha-Energies of different sources with Multi Channel Analyzer

Novel Plastic Microchannel-Based Direct Fast Neutron Detection

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

The Mössbauer Effect

Results from Silicon Photo-Multiplier neutron irradiation test

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Development of a homogeneous, isotropic and high dynamic range calorimeter for the study of primary cosmic rays in space experiments

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

AIRFLY: Measurement of the Air Fluorescence induced by electrons

Preliminary Results From The First Flight of Atic: The Silicon Matrix

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Dual readout with tiles for calorimetry.

DETECTORS. I. Charged Particle Detectors

CMS ECAL status and performance with the first LHC collisions

PoS(Baldin ISHEPP XXII)133

GaN for use in harsh radiation environments

Beta Spectroscopy. Glenn F. Knoll Radiation Detection and Measurements, John Wiley & Sons, Inc. 2000

Recent Advances of Planar Silicon APD Technology

1 of :32

Dipartimento di Fisica, Università degli Studi di Milano-Bicocca, Milano 2. Istituto di Fisica del Plasma, CNR, Milano

CMS Conference Report

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Studies of Hadron Calorimeter

TIEN-SHAN FUTURE PRESENT PASTS

Measurement of Transmittance, Emission and Light Output for PWO Crystals

Development of a Radiation Hard CMOS Monolithic Pixel Sensor

CALICE scintillator HCAL

First Applications of CVD-Diamond Detectors in Heavy-ion Experiments

Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

High Purity Germanium Detector Calibration at ISOLDE

Response curve measurement of the SiPM

Determination of Absolute Neutron Fluence to sub-0.1% uncertainty (and better)

EEE4106Z Radiation Interactions & Detection

Study of radiation damage induced by 82 MeV protons on multipixel Geiger-mode avalanche photodiodes

The Next Generation of Crystal Detectors

Application Note. The Continuous Air Monitoring (CAM) PIPS Detector Properties and Applications

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

Case study: The Lead Tungstate Calorimeter for CMS

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Abstract. II. THEORETICAL CONSIDERATIONS AND DETECTOR DESIGN A. 10 B Film Coatings and Efficiency I. INTRODUCTION

Transcription:

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes Rihua Mao, Liyuan Zhang, Ren-yuan Zhu California Institute of Technology

Introduction Because of its immunity to magnetic fields silicon based readout device is widely used in HEP calorimeters. They are often located in particle showers, where neutrons are produced copiously. While the nuclear counter effect caused by charged particles is well understood, it is less known for neutrons. Hamamatsu silicon devices tested: A pair of S8664-55 APD: 2 x 5 x 5 mm 2 (connected in parallel) An S2744-08 PIN diode: 1 x 2 cm 2 Neutron sources: 252 Cf and 241 Am-Be. ɣ-ray sources: 55 Fe, 241 Am, 57 Co and 60 Co. 2

252 Cf Measurement Set-up Neutron flux at the device surface: 1.4 10 4 n/cm 2 /s, calculated with calibrated mass (2.3 10 4 n/s/µg), geometrical distance, and time since delivery (τ 1/2 =2.6 yr). The PIN was biased at 70 V. The APDs were biased for gains of 1, 10, 35, 100 and 200. Readout Preamplifier: Canberra 2003 BT Shaping amplifier: Canberra 2026 with 0.25 µs shaping time, Digital scope: Agilent 6052A. 3

The 241 Am-Be, 241 Am and 60 Co Setup Am 241 -Be Neutron flux: 6.0 10 4 n/cm 2 /s at the device surface, calculated with the calibration (NIST 846/257817-93), distance, and time (τ 1/2 =432.2 yr). The readout is the same as that for the 252 Cf source. A similar set-up was used to carry out tests with gamma-ray and x- ray sources: 241 Am: 1.06 10 7 γ/cm 2 /s. 60 Co: 1.54 10 6 γ/cm 2 /s. 4

E Neutron from 241 Am-Be and 252 Cf Sources Neutrons from 241 Am-Be source has a broad distribution from 1 to 10 MeV with an average energy of 4.5 MeV. With a range of 1-10 MeV, the energy of neutrons from 252 Cf source is peaked at 2.2 MeV. 241 Am-Be 252 Cf S.-T. Park, J. Rad. & Nucl. Chem., Vol 256 (2003) 163 5

Calibration Set-up The p.e. in PIN was calibrated with 241 Am and 57 Co. The APD gain was measured with blue LED. The p.e. in APD was calibrated with 55 Fe. 6

S2744-08 PIN Diode Calibration Pulse height spectra were measured with X-rays from 241 Am (60 KeV) and 57 Co (122, 136 KeV) sources. The system noise is calculated by using the pedestal width. 7

S2744-08 PIN Diode Calibration Consistent calibration for electron numbers in PIN was obtained using 241 Am and 57 Co sources. The p.e. calibration for PIN diode: 57 Co, 122, 136 KeV 241 Am, 60 KeV N e /V: equivalent p.e. number/ peak volt, E x-ray : x-ray energy in ev, P x-ray : measured PH peak of x-ray, G x--ray : shaping amplifier gain for the x-ray sources, G n : shaping amplifier gain for the neutron sources, 8

S8664-55 APD Calibration with 55 Fe (I) APD gain was set at 10 and 35 9

S8664-55 APD Calibration with 55 Fe (II) APD gain was set at 100 and 200 10

55 Fe/LED Corrections and APD Calibration Large correction factors are noticed for high APD gains, which are consistent with published data in J. Chen et al, IEEE Trans. Nucl. Sci. Vol 54 (2007) 718. The calibration with 55Fe, 5.9 KeV for APD at a certain bias: N e /V: equivalent p.e. number/ volt, E x-ray : 5900 ev, P x-ray : measured PH peak, R x-ray/led : Correction factors for x-rays, G x--ray : shaping amplifier gain for the x-ray source, G n : shaping amplifier gain for the neutron sources, 11

Calibration Summary Bias (V) Device Gain PIN S2744-08 APD S8664-55 70 341 404 417 441 463 1 10 35 50 100 200 G x-ray 250 250 100 50 50 25 G n 50 2.5 2.5 2.5 2.5 2.5 N e /V ( 10 3 ) 812 438 212 144 66.7 35.8 σ n (N e ) 498 104 70 66 78 77 12

252 Cf Spectra for APD@Gain 35 The up-limit of the pulse height distribution is ~2 M electrons, or 7.2 MeV deposition in APD. There are a few tens overflow events caused by the saturated amplifier scale, indicating energy deposition of higher than 7.2 MeV. 13

252 Cf Spectra for APD at different Gains The amplifier saturation was more significant for the APD gains of 100 and 200. The fractions of events with signals of more than 150 k electrons (0.5 MeV deposition) are: 1.6x10-6,G=10 1.5x10-6,G=35 0.28x10-6,G=100 0.27x10-6,G=200, indicating that a high APD gain reduces the neutroninduced nuclear counter effect in the APD. 14

Comparison between APD and PIN Signals of up to 2.5 and 2 M electrons were observed in the PIN and APD with unit gain respectively, corresponding to 9 and 7.2 MeV energy deposition. The fractions of events with signals of more than 350 k electrons (1.3 MeV deposition) are: PIN: 27 x 10-6, APD (G=1): 2.4 x 10-6, indicating that the neutroninduced nuclear counter effect in the APD is a factor of ten smaller than that in the PIN diode. 15

16 252 Cf Spectra for PIN with Materials 1 to 2 cm thick materials were inserted at the front of the PIN. The overall effect of materials at the front of the PIN diode is small, indicating that the nuclear counter effect is dominated by the detector itself. High Z material, such PWO and LSO, enhances a little the effect, while the low Z material, such as H, C, O and Al, reduces a little the effect.

17 Gamma Background and System Checks The γ-ray background from 60 Co and 241 Am sources was checked using orders of magnitude high fluence. The spectra show no high tail. No event was recorded when APD and PIN diode was replaced by a 100 pf capacitor, indicating no background from the readout system.

Approaches to Eliminate this Effect Multiple independent readout channels for one crystal would be a good solution. The potential high cost may be minimized by an intelligent frontend chip (IFC) which reads out only uncontaminated signals. Advanced data analysis may also be implemented to reduce this effect as discussed in CMS Note 2010-12: http://cdsweb.cern.ch/record/1278160?ln=en 18

Summary MeV neutrons from 252 Cf and 241 Am-Be sources cause signals up to a few million electrons, or ~10 MeV energy deposition, in Si APD and PIN diode, indicating that the entire kinetic energy of a neutron may be converted into electron signals in these devices. The equivalent energy of calorimeter readout depends on the crystal light yield. Anomalous signals of 2 M electrons, for example, correspond to 500 and 2.5 GeV for PWO and LYSO respectively assuming the light yields of 4 and 800 p.e./mev for long crystals. The overall effect in APD is a factor of ten less than PIN diode. Increasing the APD gain reduces the effect since only a portion of the energy in APD is fully amplified as the scintillation photoelectrons. Multiple photo-devices with independent readout chains would eliminate this effect completely. An intelligent front-end chip capable of selecting un-contaminated signal will keep the total channel counting under control. The neutron induced nuclear counter effect may also be reduced by advanced data analysis. 19

Relevant paper of PIN Fast neutron detector using PIN-type silicon photodiode Y. Hosono et. al, NIM, A361, p554,1995 Fraction = 7.8 10-5 20