Thermometer Line. today s laboratory and field

Similar documents
General Accreditation Guidance. Liquid-in-glass thermometers selection, use and calibration

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

INF195 Infrared Thermometer

Bimetal Industrial Thermometers

IR/Thermistor Pen. Instruction Manual

E THERMADATA LOGGER Humidity & temperature recording meter

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

Today s Weather 24 Hour Forecaster

Dual laser + type K thermometer INFRARED THERMOMETER

Designed to go where you work

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

One-hand ph/temperature measuring instrument

INFRARED THERMOMETER Model : TM-959

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

1450 First Ave. Page 1 of 10 Chippewa Falls, WI (800) or (715) Fax: (715)

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Surface-mounting Thermostats ATH Type Series

Pain-Free Melting Point Determination. James Lee, Ph.D. Stanford Research Systems

CHEMICAL SEPARATION EXPERIMENT 2

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Compact ph Measuring Instruments With Pro Engineering

Anemometer Thermometer Hygrometer

What is the maximum distance I can have the remote sensors from the display?

MONITORING & CONTROL LABORATORIES FOR ALL YOUR LABORATORY REQUIREMENTS 50% THERMOMETER & HYDROMETER

Elcometer 116C. Sling Hygrometer. Operating Instructions

Wireless Weather Station. Instruction Manual

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

566/568. Infrared Thermometers. Getting Started

OPERATING INSTRUCTIONS

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

ED 701 General Industry Pressure Transmitter

Volumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask

Objective: Science Classroom Laboratory Safety

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version

Dispensers/Dilutors REPIPET DISPENSERS REPIPET DILUTORS PIPETS OUR BEST ALL GLASS DISPENSERS! OUR LOWEST PRICED DISPENSERS! VIRTUALLY UNBREAKABLE!

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

CS Series. Capacitance Type. Type. Proximity Sensor. Features

THERMOCOUPLE CHARACTERISTICS TRAINER

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

CONTENTS. La Crosse Technology, Ltd. Page 1

The Weather Station FEATURES:

Technical Guide TG-19-C-029-E E. Made by: rendav Date: Modifications: see last page CALIBRE 3303

One-Year Limited Warranty

BIOS. Weather. 266BC Wireless Wind Chill and Humidex Thermometer. Thermomètre sans fil pour indices de refroidissement éolien et humidex

Manual Weather Stations & Instruments

PART I: MEASURING MASS

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

Module 3 - Thermodynamics. Thermodynamics. Measuring Temperatures. Temperature and Thermal Equilibrium

Surface-mounting thermostats Series ATH

THE FIFTH ELEMENT USER INSTRUCTIONS

Temperature Measurement

Chemistry MultiMeasure Sensor PS-2170

EXPERIMENT. Beer s Law

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

PHYS102 Previous Exam Problems. Temperature, Heat & The First Law of Thermodynamics

Guide to ph Analysis.

Installation and Operation Manual. AllSync Plus Wired Clocks

InfraRed Thermometer with Laser Pointer

ph / Temperature Meter for Cheese with Application Specific Probe

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Thermodynamics. We can summarize the four laws of thermodynamics as follows:

Introduction. Measurement of temperature is generally considered to be one of the simplest and most accurate measurements performed in engineering.

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Digital Multi-Day Max/ Min/Current Air and Soil Temperatures Protocol

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

ea980r Digital Anemometer User Manual

USS ProCoil Company. WELCOME To Micrometer Training. Introduction and Lecture Phase I 6/18/2010

RT-6 Riflescopes. User Guide

Technical Guide TG-19-C-045-E C. Made by: pelrom Date: Modifications: see last page CALIBRE 3301

technical guide Working Thermometers Calibration Procedures

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Lever-type Dial Test Indicators

Rapid RH Portable ph Meter. User's Manual

Wireless Color Forecast Station Model: K86319

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

Digital Multi-Day Soil Temperatures Protocol

Experiment 3. Electrical Energy. Calculate the electrical power dissipated in a resistor.

Kestrel 4500 Pocket Weather Tracker

Have a look at the following video which shows an invention developed in the High-Low Tech Lab at MIT.

6 + WARNING: CHOKING HAZARD - Small parts/small ball(s). Not for children under 3 years.

Bante210 Benchtop ph Meter Instruction Manual

BINOCULAR STEREOSCOPIC MICROSCOPE MBS-10. User Manual

Temperature Sensor -40 C to 140 C

symphony Multisensor Probes

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

TESA MICROMASTER Electronic Micrometers with Digital Display

Non contact temperature measurement

Mini Environmental Quality Meter

CHM101 Lab Measurements and Conversions Grading Rubric

Operating Instructions for Digital Manometer. Model: MAN-SD

Transcription:

Thermometer Line The VEE GEE Thermometer line consists of a large selection of high-quality instruments to meet the general and specific requirements for temperature analysis in today s laboratory and field The VEE GEE line includes general laboratory, dial, digital, and wall-mount thermometers. There is also a large selection of thermometer armors to protect liquid-in-glass thermometers.

General Glass Thermometers Serialized, Precision Thermometers, VEE GEE, fill VEE GEE Precision, Serialized thermometers are ideal for use in laboratories, universities, food/beverage, environmental, wastewater, and many other general-purpose applications requiring serialization. Sub Division Filled Approx. Length Immersion (mm) 80701 80702 80703 80706 80707 80708 80901 80902 80903 80905 80906 80907 80908 809-30 to 120 F -4 to 230 F 0 to 300 F -35 to 50 C -20 to 1 C -20 to 150 F -30 to 120 F -4 to 230 F 0 to 300 F 20 to 500 F -35 to 50 C -20 to 1 C -20 to 150 C - to 250 F Safety Blue Serialized, Encapsulated Thermometers, VEE GEE, fill, Encapsulated in FEP NOTE: Non Roll Fittings Sold Separately. Cat No. 82998 For a thermometer in this selection with an armor kit see page 6. 80902 80902E VEE GEE Precision, Serialized, Encapsulated thermometers with FEP plastic coating. In the event of breakage, the FEP coating contains the broken liquid and glass, preventing contamination or injury. 80701E 80702E 80703E 80704E 80706E 80707E 80708E 80901E 80902E 80903E 80904E 80906E 80907E 80908E -30 to 120 F, Encapsulated -4 to 230 F, Encapsulated 0 to 300 F, Encapsulated 30 to 220 F, Encapsulated -35 to 50 C, Encapsulated -20 to 1 C, Encapsulated -20 to 150 C, Encapsulated -30 to 120 F, Encapsulated -4 to 230 F, Encapsulated 0 to 300 F, Encapsulated 30-220 F, Encapsulated -35 to 50 C, Encapsulated -20 to 1 C, Encapsulated -20 to 150 C, Encapsulated Sub Division Filled Approx. Length Immersion (mm) NOTE: Non Roll Fittings Sold Separately. Cat No. 82998 For a thermometer in this selection with an armor kit see page 6. Spirit-Filled Laboratory Thermometers, VEE GEE VEE GEE Spirit-filled glass thermometers are suitable for general lab use, school, and testing. They are available in a variety of ranges to meet many applications. Permanent markings and red liquid are easy to read against a white backing. Complete with Non Roll Fittings. 80501 80501 80502 80503 80504 80521 80601 80602 80603 80604 80621 80802-20 to 1 C -20 to 150 C 0 to 230 F 0 to 300 F -20 to 1 C / 0 to 230 F -20 to 1 C -20 to 150 C 0 to 230 F 0 to 300 F -20 to 1 C / 0 to 230 F -20 to 1 C No Markings Length 305mm / 305mm / 305mm / 305mm / 305mm / 305mm / 305mm / 305mm / 305mm / 305mm / 305mm / Immersion (mm) (2)

Dial Thermometers VEE GEE dial thermometers are an excellent choice for many applications including food & beverage quality control, general lab use, asphalt/concrete testing, and soil & compost testing. A wide variety of ranges are available in the three separate sizes. The smaller stem and face of the standard unit fits nicely into a shirt pocket or holder while the face and stem of the large unit allow for deeper penetration into the sample. The large faces and long stems of the 3 dial models are perfect for soil & compost testing. Catalog numbers 81550G, 82550DG, 82160-6, 82160-12, 82200-36, 82200-48, & 82200-72 feature glass faces. 1 Dial (Standard) Note: A plastic sheath is included with all standard-sized dial thermometers. Weight: 5.5g 870 811 81125 81150 81160 81220 81250 81550 81550G -40 to 70 C - to +1 C +25 to +12 0 to +150 C +40 to +160 F 0 to 220 F 0 to +250 C +50 to +550 F +50 to +550 F 1 F ± ±1 F ± ± Face Diameter Weight (g) 15 870 1.75 / 2 Dial (Large) Comes with Clip 820 820V 821 82125 82150 82160 82220 82250 82250F 82550 82550DG 0 to 0 C -50 to +0 C - to +1 C +25 to 12 0 to +150 C -40 to +160 F 0 to +220 F 0 to +250 C +50 to +250 F +50 to +550 F + to 290 C +50 to +550 F 2.5 C 1 F 5 C ±1 F ± ±2.5 C Face Diameter 51mm / 2 Weight (g) 19 19 19 36 82220 82550DG & Clip 3 Dial (Soil & Compost Testing) F & C available for 6, & 36 82160-6 82070-6 82160-12 82070-12 82200-36 820-36 82200-48 82200-72 -40 to 160 F 0 to 0 C -40 to 160 F 0 to 0 C 0 to 200 F 0 to 0 C 0 to 200 F 0 to 200 F ± ± ± ± ± ± ± ± Face Diameter 305mm / 305mm / 914mm / 36 914mm / 36 122cm / 48 183cm / 72 (3) 6.4mm / 0.25 6.4mm / 0.25 6.4mm / 0.25 6.4mm / 0.25 7.9mm / 0.313 7.9mm / 0.313 7.9mm / 0.313 7.9mm / 0.313 Weight (g) 156 156 170 170 255 255 284 354 82160-6

Digital Thermometers Min/Max Digital Thermometer / Hygrometer / Clock This VEE GEE digital thermometer registers maximum and minimum temperatures in both Celsius and Fahrenheit scales. The large displays shows humidity, temperature, and time. There s even an alarm clock. Mount on a wall or set on a lab table for easy readability. Used for recording temperature differentials. 84004 0 to 50 C 32 to 12 20-99% Humidity 1% ± ± ± 3% Dimensions 1 x 98 x 21mm / 4.33 x 3.86 x 0.83 Weight (g) 1.6 Humidity Display Temperature Display in either Celsius or Fahrenheit Time Display 84004 Digital Stem Thermometer-Series VEE GEE digital stem thermometers are high accuracy and now come in a stem length and an ultra accurate model. Ideal for temperature monitoring in essentially any setting, laboratories,: for easily monitoring reagents and liquids in test tubes, beakers, & flasks, food processing, refrigeration, and horticulture. The 83000-Series features a dual scale ( C / F), fast 1-second update time, and a swiveling head that can be moved a full 180 for easy reading in any position. Both the ON/OFF switch and the Scale Selection switch are located on the face for simple access. The thermistor sensor stems are stainless steal, 3.5mm (0.138 ) diameter and come with a protective case featuring a pocket clip. Also includes a 1.5V alkaline coin cell battery (Type LR44) and features automatic power-off after minutes of idle use. Resolution Face Dimensions Weight 832 832-12 -50 to 150 C / -58 to 30 0. / 0.1 F ±1.0 C / ±2.0 F 36 x 17mm / 1.4 x 0.7 300 mm/ 14.2g / 0.5 oz. 19.8g /.7 oz. 831 - to 0 C /- 14 to 21 0. / 0.1 F ±1.0 C / +±1.0 F 36 x 17mm / 1.4 x 0.7 14.2g / 0.5 oz. (4)

Digital, Mini Fold Sampling: 1 second Battery: CR2032 Dimensions: 90mm X 33mm X 13mm (folded) 145mm X 33mm X13mm (unfolded) : 55mm Maximum / Minimum Reading Memory 1. Press (Max/Min) to display maximum reading (Max icon flashing) 2. Press the button again to display minimum reading (Min icon flashing) 3. Press the button once more, will return to normal measurement. 4. Press and hold the button for about three seconds, then release it to reset the memory values to current reading. 5. Reset the memory once before taking new maximum/minimum reading. Thermometers, Digital, Mini Fold VEE GEE, C/ F Scales, Min Max, LCD Readout, On-Off Switch, Folding Stem Resolution / Dimensions Weight 834-50 to +200 C / -58 to +39 0.1 /±0.5 C from - to 0 C, ±1.5 C remainder & 0.1 /±0.9 F from 14 to 21, ±2.7 F remainder 90mm X 33mm 55 mm 55 mm 9 oz./ 2.55g Digital, IP67 Rated against Dust and Moisture Ingress Wide Variety of Industry Uses Including:. Snow/Earth. Agriculture. Laboratories. Food/Beverage. Forestry/Soil. Horticulture DATA HOLD FUNCTION 1. Press (HOLD) to retain display reading. C or F flashes. 2. Press the button again to display normally. MAXIMUM AND MINIMUM READING MEMORY 1. Press (MAX/Min) button to display maximum reading. The icon Max flashes. 2. Press the button again to display minimum reading. The icon Min flashes. 3. Press the button once more to display normally. 4. To reset the memory, switch the thermometer off and then on. 5. Reset the memory, switch the thermometer off and then on. 6. Reset the memory once before taking new maximum/ minimum reading. BATTERY REPLACEMENT 1. Use a suitable Phillips screw driver to take out 2 pieces of screw from the bottom case. 2. Remove the bottom case and replace the battery. 3. Put back the bottom case and tighten up the screws. Thermometers, Digital, IP67 Rated against Dust and Moisture Ingress VEE GEE, C/ F Scales, Min Max, LCD Readout, On-Off Switch, Hold Function Resolution / Dimensions Weight 833-50 to +200 C / -58 to +39 0.1 /±0.5 C from - to 0 C, ±1.5 C remainder & 0.1 /±0.9 F from 14 to 21, ±2.7 F remainder 155mm X 41mm 125 mm 55 mm 14.2g / 0.5 oz. (5)

Wall-Mount Thermometers Wall-Mount Thermometers VEE GEE wall-mount thermometers are large-sized instruments suitable for the laboratory or the home. They feature all-black backing with bright, permanently-fused markings. Three different styles are available with combinations of clocks, thermometers, and hygrometers. 85001 requires one AA battery not included. Diameter: 248mm (9.75 ); Depth: 40mm (1.6 ); Weight: 487g. Cat. No: 85001 Description: Thermometer-Hygrometer-Clock Cat. No: 85002 Description: Thermometer-Hygrometer Cat. No: 85003 Description: Thermometer -20 to 140 F 0-0% 2% ±2% -40 to 50 C -40 to 120 F 0-0% 2% ± ± ±2% -40 to 50 C -40 to 120 F ± ± Thermometer Accessories Thermometer Clips Description 82999 Clip for Dial Thermometers (used for attaching to containers, tanks, etc.) For Models 1, 1.75 and 2 Dial Thermometers Non Roll Fittings 82998 Description Non Roll Fittings - Fit on all Glass Thermometers (12 Pk) (6)

Thermometer Armors VEE GEE thermometer armor cases protect liquid-in-glass thermometers from rough handling and shock during use. Armors constructed of nickel-plated brass are available in a wide range of sizes and feature a threaded screw cap with ring top for suspension where necessary. Additionally, 2- and 3- part type armor cases are available. Nickel-Plated Brass Armor Only 83025A 83025B 83025C 83025D 83025E 83025F 83025G 83025N 83025H 83025J 83025M 83040N 83041N For Thermometer Length 305mm / 178mm / 7 229mm / 9 356mm / 14 381mm / 15 393 / 15.5 406mm / 16 457mm / 18 6mm / 24 2- and 3- Part Type Armor Cases For Thermometer length Outside Diameter Type 2-Part (Case & Cap) 3-Part (Case, Cap, & Inner Sleeve w/ Cut-Out) Inside Diameter Metal Nickel-Plated Brass Nickel-Plated Brass Armored Glass Thermometers, VEE GEE Complete with non removable protective plastic sheath and ring top. The armor casing has inlets around the thermometer bulb so measurements are taken without removing the thermometer. Permanent markings and spirit filled red liquid are easy to read against a white backing. Weight: 15g. 84050 84125 83030A 0 to 50 C 25 to 12 1 F Plastic Armor Only (For 6 Liquid-In-Glass Thermometers) Length Serialized, Precision Thermometers with Nickel-Plated Brass Armor Kit Immersion (mm) fill VEE GEE Precision, Serialized thermometers are ideal for use in laboratories, universities, food/beverage, environmental, wastewater, and many other general-purpose applications requiring serialization. Sub Division Filled Approx. Length Immersion (mm) 80701-A 80702-A 80703-A 80706-A 80707-A 80708-A 80901-A 80902-A 80903-A 80905-A 80906-A 80907-A 80908-A 809-A -30 to 120 F -4 to 230 F 0 to 300 F -35 to 50 C -20 to 1 C -20 to 150 F -30 to 120 F -4 to 230 F 0 to 300 F 20 to 500 F -35 to 50 C -20 to 1 C -20 to 150 C - to 250 F Safety Blue Serialized, Encapsulated Thermometers with Nickel-Plated Brass Armor Kit 80701E-A 80702E-A 80703E-A 80704E-A 80706E-A 80707E-A 80708E-A 80901E-A 80902E-A 80903E-A 80904E-A 80906E-A 80907E-A 80908E-A -30 to 120 F, Encapsulated -4 to 230 F, Encapsulated 0 to 300 F, Encapsulated 30 to 220 F, Encapsulated -35 to 50 C, Encapsulated -20 to 1 C, Encapsulated -20 to 150 C, Encapsulated -30 to 120 F, Encapsulated -4 to 230 F, Encapsulated 0 to 300 F, Encapsulated 30-220 F, Encapsulated -35 to 50 C, Encapsulated -20 to 1 C, Encapsulated -20 to 150 C, Encapsulated Sub Division Filled NOTE: Non Roll Fittings Sold Separately. Cat No. 82998, See Page 5 Approx. Length Immersion (mm) fill, Encapsulated in FEP NOTE: Non Roll Fittings Sold Separately. Cat No. 82998, See Page 5 80702-A

Thermometer Information Immersion Types for Liquid-In-Glass Thermometers Thermometers are one of the most important instruments used in the laboratory and are a relatively inexpensive means of reliably measuring temperature, provided they are properly used and not abused. It is essential that the instruments be used in the manner prescribed if true temperatures are to be ascertained. The following are some terms that should be understood and adhered to when true temperatures are to be obtained. Immersion. Such a thermometer is designed to indicate temperatures correctly when the bulb and the entire liquid column are exposed to the temperature being measured, except for a minimal length emergent to be visible. Therefore, the thermometer is immersed into the medium up to the point of reading. Immersion. Such a thermometer has a line around it at the immersion distance from the bottom. It indicates correctly when the bulb and liquid column to that line are exposed to the temperature being measured and the emergent stem is at ambient temperature. Therefore, the thermometer is immersed only up to the immersion line. Full Immersion. No VEE GEE Brand Thermometers feature full immersion. However, it is important to make the distinction between full and total immersion. With full immersion thermometers, the complete thermometer (including the expansion chamber) is immersed in the medium. These instruments are generally read through a window or port in the bath. Column Separation Temperature Conversion C = ( F - 32) / 1.8 F = ( C x 1.8) + 32 The largest single cause for failure of liquid-in-glass thermometers in the lab is due to separated columns. This can occur in transit or in the lab. The simplest and safest method to reunite a separated spirit-filled column is to force the liquid down the capillary tube by using a centrifuge, if one is available, with a cup deep enough to ensure that the centrifugal force is below the liquid column. Carefully insert the thermometer, bulb down, in the centrifuge. Place some cotton wadding at the bottom of the cup to prevent any damage to the bulb. Turn on the centrifuge in just a few seconds all of the liquid will be forced past the separation. If the cup is not deep enough and all of the centrifugal force is not below the column, the column will split, forcing part of the liquid down. The remainder will be forced up, filling the expansion chamber. If a centrifuge is not available, the column can be reunited by holding the thermometer in an upright position and gingerly tapping the stem above the separation against the palm of your hand. As you gently tap the thermometer, observe the liquid above the separation until it breaks away from the wall of the capillary and runs down to join the main column. Spirit Filled and Safety Blue Fill VEE GEE no longer carries liquid in glass thermometers with mercury. Red spirit fill is a kerosene based column with red dye which is significantly safer than mercury. Safety Blue filling is an organic, performance liquid that is bio-degradable and exhibits all of the qualities of mercury without the risk of contamination and hazards associated with mercury. VEE GEE Precision, Serialized, Encapsulated thermometers are coated with FEP plastic coating. These thermometers are ideal for use in laboratories, universities, food/beverage, environmental, wastewater, and many other general-purpose applications requiring serialization. In the event of breakage, the FEP coating contains the broken liquid and glass, preventing contamination or injury. (8) No. VGBRCTherm021218