Eurocode 3 for Dummies The Opportunities and Traps

Similar documents
Structural Steelwork Eurocodes Development of A Trans-national Approach

Structural Steelwork Eurocodes Development of A Trans-national Approach

Job No. Sheet No. Rev. CONSULTING Engineering Calculation Sheet. Member Design - Steel Composite Beam XX 22/09/2016

Design of Beams (Unit - 8)

Made by SMH Date Aug Checked by NRB Date Dec Revised by MEB Date April 2006

Structural Steelwork Eurocodes Development of A Trans-national Approach

STEEL MEMBER DESIGN (EN :2005)

STEEL BUILDINGS IN EUROPE. Multi-Storey Steel Buildings Part 8: Description of member resistance calculator

STEEL BUILDINGS IN EUROPE. Multi-Storey Steel Buildings Part 10: Technical Software Specification for Composite Beams

C6 Advanced design of steel structures

Steel Frame Design Manual

1C8 Advanced design of steel structures. prepared by Josef Machacek

Advanced Analysis of Steel Structures

APOLLO SALES LTD PUBLIC ACCESS SCAFFOLD STEP DESIGN CHECK CALCULATIONS

Made by PTY/AAT Date Jan 2006

COMPARISON BETWEEN BS 5950: PART 1: 2000 & EUROCODE 3 FOR THE DESIGN OF MULTI-STOREY BRACED STEEL FRAME CHAN CHEE HAN

Job No. Sheet 1 of 7 Rev A. Made by ER/EM Date Feb Checked by HB Date March 2006

University of Sheffield. Department of Civil Structural Engineering. Member checks - Rafter 44.6

Lateral Torsional Buckling (sections class 1-3) - Column Item COx

APOLLO SCAFFOLDING SERVICES LTD SPIGOT CONNECTION TO EUROCODES DESIGN CHECK CALCULATIONS

A. Ideal beam without imperfections: Critical moment M cr

Basis of Design, a case study building

BRACING MEMBERS SUMMARY. OBJECTIVES. REFERENCES.

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

Plastic Design of Portal frame to Eurocode 3

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING. BEng (HONS) CIVIL ENGINEERING SEMESTER 1 EXAMINATION 2016/2017 MATHEMATICS & STRUCTURAL ANALYSIS

Design of Compression Members

Fundamentals of Structural Design Part of Steel Structures

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

APPENDIX 1 MODEL CALCULATION OF VARIOUS CODES

= = = 1,000 1,000 1,250. g M0 g M1 g M2 = = = 1,100 1,100 1,250 [ ] 1 0,000 8,000 HE 140 B 0,0. [m] Permanent Permanent Variable Variable Variable

9-3. Structural response

3. Stability of built-up members in compression

CIVL473 Fundamentals of Steel Design

SECTION 7 DESIGN OF COMPRESSION MEMBERS

FLOW CHART FOR DESIGN OF BEAMS

Job No. Sheet No. Rev. CONSULTING Engineering Calculation Sheet

Failure in Flexure. Introduction to Steel Design, Tensile Steel Members Modes of Failure & Effective Areas

Application nr. 3 (Ultimate Limit State) Resistance of member cross-section

ENCE 455 Design of Steel Structures. III. Compression Members

On Design Method of Lateral-torsional Buckling of Beams: State of the Art and a New Proposal for a General Type Design Method

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

SUMMARY FOR COMPRESSION MEMBERS. Determine the factored design loads (AISC/LRFD Specification A4).

Bridge deck modelling and design process for bridges

THE EC3 CLASSIFICATION OF JOINTS AND ALTERNATIVE PROPOSALS

MODULE C: COMPRESSION MEMBERS

Steel Structures Design and Drawing Lecture Notes

Structural Mechanics Column Behaviour

Structural Calculations for Juliet balconies using BALCONY 2 System (Aerofoil) handrail. Our ref: JULB2NB Date of issue: March 2017

Mechanics of Materials Primer


Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

VALLOUREC & MANNESMANN TUBES. Design-support for MSH sections

MINLP optimization of the single-storey industrial building steel structure

Equivalent Uniform Moment Factor for Lateral Torsional Buckling of Steel Beams

to introduce the principles of stability and elastic buckling in relation to overall buckling, local buckling

= 50 ksi. The maximum beam deflection Δ max is not = R B. = 30 kips. Notes for Strength of Materials, ET 200

DESIGN OF BUCKLING RESISTANCE OF COMPRESSED HSS - CHANNELS

Compression Members Columns II

Compression Members. ENCE 455 Design of Steel Structures. III. Compression Members. Introduction. Compression Members (cont.)

Accordingly, the nominal section strength [resistance] for initiation of yielding is calculated by using Equation C-C3.1.

7.3 Design of members subjected to combined forces

REINFORCED CONCRETE DESIGN 1. Design of Column (Examples and Tutorials)

STRUCTURAL ANALYSIS CHAPTER 2. Introduction

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

Engineering Science OUTCOME 1 - TUTORIAL 4 COLUMNS

NOVEL FLOWCHART TO COMPUTE MOMENT MAGNIFICATION FOR LONG R/C COLUMNS

Tekla Structural Designer 2016i

Effective stress method to be used in beam finite elements to take local instabilities into account

two structural analysis (statics & mechanics) APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2017 lecture STRUCTURAL ANALYSIS AND SYSTEMS

Civil Engineering Design (1) Design of Reinforced Concrete Columns 2006/7

Lateral-torsional buckling of unrestrained steel beams under fire conditions: improvement of EC3 proposal

Design Examples using midas Gen to Eurocode 3. Integrated Design System for Building and General Structures

CIVIL DEPARTMENT MECHANICS OF STRUCTURES- ASSIGNMENT NO 1. Brach: CE YEAR:

1C8 Advanced design of steel structures. prepared by Josef Machacek

ENG1001 Engineering Design 1

Advanced stability analysis and design of a new Danube archbridge. DUNAI, László JOÓ, Attila László VIGH, László Gergely

TOPIC TRAINING CODE CHECK COLD-FORMED STEEL PROFILES

Finite Element Modelling with Plastic Hinges

NUMERICAL EVALUATION OF THE ROTATIONAL CAPACITY OF STEEL BEAMS AT ELEVATED TEMPERATURES

CHAPTER 4. Design of R C Beams

PES Institute of Technology

General Comparison between AISC LRFD and ASD

Delhi Noida Bhopal Hyderabad Jaipur Lucknow Indore Pune Bhubaneswar Kolkata Patna Web: Ph:

- Rectangular Beam Design -

of I Section Members

Mechanics of Structure

Experimental Study and Numerical Simulation on Steel Plate Girders With Deep Section

ε t increases from the compressioncontrolled Figure 9.15: Adjusted interaction diagram

National Exams May 2015

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

Bending Stress. Sign convention. Centroid of an area

Design of Reinforced Concrete Structures (II)

3 Hours/100 Marks Seat No.

Job No. Sheet 1 of 6 Rev B. Made by IR Date Oct Checked by FH/NB Date Oct Revised by MEB Date April 2006

DESIGN OF BEAMS AND SHAFTS

CE 221: MECHANICS OF SOLIDS I CHAPTER 1: STRESS. Dr. Krisada Chaiyasarn Department of Civil Engineering, Faculty of Engineering Thammasat university

Singly Symmetric Combination Section Crane Girder Design Aids. Patrick C. Johnson

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

ENGINEERING SCIENCE H1 OUTCOME 1 - TUTORIAL 4 COLUMNS EDEXCEL HNC/D ENGINEERING SCIENCE LEVEL 4 H1 FORMERLY UNIT 21718P

Transcription:

Eurocode 3 for Dummies The Opportunities and Traps a brief guide on element design to EC3 Tim McCarthy Email tim.mccarthy@umist.ac.uk Slides available on the web http://www2.umist.ac.uk/construction/staff/ mccarthy/index.htm Follow the link from my home page From 21 March 2003 2

Eurocode 3 Current status Coverage Pitfalls Major and minor differences with BS5950 Element Design Beams, Struts Capacity comparisons Overview 3 EC3 Current Status 4

E-SCI News March 2003 5 Eurocode terminilogy EN EuroNorm mandatory standard ENV EuroNorm Voluntaire You can use it if you wish DD Draft for development DC Draft for public comment pren Pre-EuroNorm between DD and EN 6

EC3 Current Published Status DD ENV 1993-1-1:1992 1:1992 Eurocode 3. Design of steel structures. General rules and rules for buildings (together with United Kingdom National Application Document) DD ENV 1993-1-2:2001 Eurocode 3. Design of steel structures. General rules. Structural fire design (together with United Kingdom National Application Document) DD ENV 1993-1-3:2001 3:2001 Eurocode 3. Design of steel structures. General rules. Supplementary rules for cold formed thin gauge members and sheeting 7 Other EC s s Published Status pren 1994-1-1:2002 1:2002 Design of composite steel and concrete structures. Part 1.1 General rules and rules for buildings. Stage 49 Examination Document DD ENV 1998-3:1997 Eurocode 8: Design provisions for earthquake resistance of structures. Towers, masts and chimneys 8

Potential pitfalls Terminology Restricted vocabulary Change in symbols More logical symbol name conventions Lots of subscripts Changes in values Young s s Modulus etc Multiple documents Need to consult more than one part 9 BS5950 Force Capacity Terminology EC3 Action Resistance M c Design strength p y Dead load Live load Wind load M c,rd Yield strength f y Permanent load Variable load Another variable load 10

BS5950 in wonderland Words evolved over time Inconsistent at times No link with concrete structural codes Terminal ogy EC3 Vocabulary consistent with meaning Consistent across all Eurocodes Easy to translate 11 Symbols BS5950 Eurocode Elastic Modulus Z W el Plastic Modulus S W pl Radius of r i Gyration Torsion constant J I t Warping constant H I w 12

Changes in Values Young s s Modulus BS - 205000 N/mm² EC - 210000 N/mm² Shear modulus BS 79000 N/mm² EC - 81000N/mm² Changes in load factors BS 1.4Gk + 1.6 Qk EC 1.35Gk + 1.5 Qk Many extra load combinations in EC Main variable action Secondary variable action 13 Axes redefined in Eurocodes Major axis is y-y Vertical axis is z-z X direction is along the member This is consistent with most FE and Frame analysis software EC3 Definitions 14

BS Section classification ε = (275/p y ) 0.5 15 pren1993 Classification Different outstand Different ε ε = (235/f y ) 0.5 16

Multiple documents The DD ENV 1993:1-1 1 contained all the information in one 300 page document. It also contained the National Application Document pren1993-1-1 1 Contains member and frame design but omits fasteners pren1993 must be read in conjunction with the UK National Annex 17 Element Design Beams Moment capacity/resistance Shear Deflections Compression members Lateral Torsional Buckling y z u x Civil & Construction φengineering 18

BS5950 Class 1 and 2 M c = p y S Moment Resistance Class 3 semi-compact M c = p y Z or M c = p y S eff Class 4 slender M c = p y Z eff Low shear F v < 60 % P v EC3 Class 1 and 2 M c,rd = f y W pl γ M1 = 1.05 in UK Class 3 M c,rd = f y W el,min pl /γ M1 el,min /γ M1 Class 4 M c,rd = f y W eff,min Low shear V Ed < 50% V plrd eff,min /γ M1 19 BS5950 P v = 0.6 p y A v Shear area A v = td Shear buckling if d/t > 70ε Shear Resistance EC3 V pl,rd = A v (f y / 3)/ 3)/γ M1 Shear area A v = A 2bt f +(t w +2r)t f Approx = 1.04tD Shear buckling if h w /t w > 72ε 20

BS5950 Serviceability LS Imposed load only Span/360 - brittle Span/200 - generally Deflections EC3? EN1990 Serviceability LS Permanent action, δ 1 Variable action, δ 2 Pre-camber, δ 0 δ max < L/ 250 δ 2 < L / 350 brittle δ 2 < L / 300 generally 21 BS5950 Serviceability LS Imposed load only Span/360 - brittle Span/200 - generally Deflections EC3? EN1990 Serviceability LS Permanent action, δ 1 Variable action, δ 2 Pre-camber, δ 0 d max = d 1 + d 2 - d 0 δ max < L/ 250 δ 2 < L / 350 brittle δ 2 < L / 300 generally δ 1 δ 2 δ 0 δ max 22

Compression Members P c = Ag p c from Tables 23 and 24 p c is a function of λ BS5950 requires a large number of tables N b,rd =χ A f y /γ M1 χ is a reduction factor χ depends on? non-dimensional slenderness Perry-Robertson approach 23 = Compression members N f b, Rd a y M 1 1? 0.5 + = χβ A but [ ] 2 2 f? 1 + a (? 0,2 ) [ ] 2? f = 0,5 + [ ] 0.5 βaa f y Ncr = λ λ1, λ π E f y λ = = 1 f γ? 1 24

Compression members N = χβ A b, Rd a y M 1 f γ 25 Example UC 203x203x60 of grade S275 is axially loaded and pinned at each end of its 6m length. A = 76.4 cm²,, flange thickness, tf = 14.2mm, radius of gyration about minor axis, i zz = 5.2 cm, depth, h = 209.6mm, width b = 205.8 h/b= = 1.01 => H section Table 3.1: t f = 14.2mm < 40mm therefore fy=275n/mm =275N/mm² for S275 grade E = 210000 N/mm² Slenderness - λzz= = 600/5.2 = 115 <180 OK βa=1.0, implies λ 1 =π(e/fy) 0.5 = 86.8 ( λ zz / λ 1 ) βa 0.5 = 115/86.8 = 1.324? 26

0.38 1.32 27 Example UC 203x203x60 of grade S275 is axially loaded and pinned at each end of its 6m length. Figure 6.3 factor, χ = 0.38 N brd = 0.38*1.0*76.4*10²*275/1.05 *275/1.05 = 760kN BS5950 786kN 28

But EC loads are typically 5% lower than BS Scaling the capacity by this figure gives: EC3 = 760/0.95 = 800 kn EC3 stronger than BS at 786 kn 29 LTB BS5950:2000 M x M b /m LT M b = p b modulus p b from λ LT λ LT = uvλ λ ß W Class 1 & 2: β W = 1.0 and M x M cx Class 1 & 2: Mb b = p b S x 30

LTB BS5950:2000 M x M b /m LT M b = p b modulus p b from λ LT λ LT = uvλ λ ß W Mb b = p b S x and M x M cx 31 BS 5959 Table 18 m LT When β = 0 m LT = 0.6 32

BS5950 - m LT for UDL 33 p b from Table 16 34

1.0 For UB, UC EC3 LTB Same approach as for Compression M? LT b.rd = χ LT β ww pl.y f y / = φ LT + 1 2 2 [ φ λ ] 0, 5 LT LT γ M 1 1.05 φ LT = 0,5 1 + LT ( λlt 0.2) + λlt 2 35 φ LT α LT = 0,34 for rolled UCsections EC3 LTB = 0,5 1+ LT ( λlt 0.2) + λlt α LT = 0,49 for rolled UB sections 2 W ply.f y The non-dimensional slenderness λ LT = M / M pl. Rd cr π EI I L GI 2 2 z w t M cr = C1 + Where 2 2 C1 results from the L I z π EI z bending moment diagram 36

EC3 LTB Moment factor, C 1 loaded between restraints 37 EC3 LTB Moment factor, C 1, due to end moments 38

Same curves as before! M = χ β W f b.rd LT w pl.y y / γ M 1 39 Example Uniform moment unbraced length 3m UB 610x229x140 S275 BS M b = 1100 knm EC3 M brd = 960kNm For comparison scale by 1/0.95 M brd scaled = 1010 knm < than BS 40

Summary of LTB BS5950 splits calculations between strength and equivalent moment EC3 combines equivalent moment and section properties to give a reduction factor EC3 uses EXACT same buckling curves for LTB and Strut buckling EC3 look awful but is easily programmed in a spreadsheet 41 Conclusions Eurocodes are not that difficult They are just a little different Rationalises terminology across materials and countries The EFTA region is 10 times bigger than UK Eurocodes are not going to go away this time 42

Questions?? 1. How quickly will the take up be in the UK? Ans: : It should be quicker than the switch from BS449 to 5950 was since both EC3 and BS5950 are limit states codes. EC3 will become mandatory. 2. What does EC3 say about effective lengths? Ans: : The EC3 guidance is not as helpful as BS5950 Table 22. EC3 gives the general approach for effective lengths in frames which results in the same values as Table 22 43 Questions?? 1. How is Europe progressing with using EC3? Ans: : The German speaking countries have already adopted the DDENV as a DIN. Benelux countries are well advanced. The rest are planning the implementation. 2. What s s in EC3 about sway, lambda crit etc? Ans: : There is a lengthy section in the pren on frame stability. On initial viewing, this looks very like the BS5950:2000 approach. See Section 5 of the pren for the full details 44