Eppendorf Reference : The pipette.

Similar documents
The New Legend. Eppendorf Reference 2 Pipette

Raise the limits. Eppendorf Research plus

December 2010 No 036. The electronic Eppendorf Xplorer pipette Versatile adjustment

The New Legend. Eppendorf Reference 2 Pipette

PhysioCare Concept. Make your Lab a better place

NEW! Your bacteria s favorite! Eppendorf Eporator

Technical Report Exact dispensing of whole blood using the Eppendorf positive displacement system Multipette Xstream /Repeater Xstream

Simply Better Pipetting

PhysioCare Concept improved. The feeling of a new philosophy

PhysioCare Concept improved. The feeling of a new philosophy

Simply better pipetting!

Still Making History. Over 50 years of pipetting

ept.i.p.s. Version A

NEW! ep Dualfilter T.I.P.S. Peak of perfection

Applications Note 228 September 2010

No 022 December Application-Specific Requirements for Consumables in the Laboratory

Technical Report Eppendorf Deepwell Plates and Microplates Investigations of sealing methods

Applications Note 164 October 2007

Spa & Wellness for Pipettes

N) manual. Biomaster Operating manual

Now also in Eppendorf LoBind. Conical Competence. Eppendorf Conical Tubes 15 ml and 50 ml

Eppendorf ept.i.p.s. LoRetention Comparison of low retention pipette tips via simple and fast absorbance measurements in the BioPhotometer plus

The Plus for your lab!

Applications Note 202 October 2008

ept.i.p.s. Instructions for use Version B

Larger Display Easier to Use. Generation E. Repeater E3 and E3x: Dispense without compromising accuracy or precision

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

N) justment. Register your instrument! Eppendorf Research plus. Factory Adjustment

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

NEW: 5.0 ml screw cap tube. The Missing Link. Eppendorf Tubes 5.0 ml Discover a new sample handling system

NEW. A class of its own. Centrifuge 5430 / 5430 R

Eppendorf Xplorer Eppendorf Xplorer plus. Ordering information. Register your instrument!

Spa & Wellness for Pipettes

Eppendorf Plate Deepwell 96 and 384: RecoverMax

Multitalent for transfection and cell fusion. Eppendorf Multiporator

Applications Note 215 September 2009

Well within Reach. The Eppendorf Pipette Holder System

Precise and Accurate whole Blood Dispensing with Multipette E3x and Combitips advanced

The Pure Truth. Eppendorf Forensic DNA Grade according to ISO 18385

New Promotions July 1 December 31, Take Good Care of Your Cells. More great offers for your cell biology processes

Get the Eppendorf Advantage!

Eppendorf Consumables it s Your sample. Peak of Perfection. Eppendorf Liquid Handling Consumables

NGS Made Easy. Optimize your NGS library preparation with the epmotion Automated liquid handling system

Promotion period: September 15 - December 31, Super Sale. Quality at unbeatable prices

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 0

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

Electrical safety testing Checklist

Automated purification of high quality genomic DNA

stance et Helper Eppendorf Pipet Helper Chemical Resistance

Multiple Talents. Eppendorf Temperature Control and Mixing Instruments

Multipette / Repeater M4 allows for fast, precise and sterile liquid transfer in cell culture

WhatsNext. Ready. Set. Pipette! New Innovative solutions for 384-well pipetting. Issue 1/ st March 30 th June 2019.

Growth in Motion. The next evolution in biological shakers the Innova S44i

Micropipetting Basics

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 1

New Promotion January 1 June 30, Take Good Care of Your Cells. Smart solutions from Eppendorf for your cell biology processes

Eppendorf BioSpectrometer 6135/6136/6137

Eppendorf Vis Cuvettes. Instructions for use

Natural Winners. Eppendorf Liquid Handling Instruments: Unrivaled in technology, efficiency and handling for over 50 years

Applications Note 224 April 2010

Eppendorf UVette. Instructions for use

The New Eppendorf X-Drive - Maximum Performance, Flexibility and Longevity for Demanding Shaker Tasks

Natural Winners. Eppendorf Liquid Handling Instruments: Unrivaled in technology, efficiency and handling for over 50 years

Superior well-to-well Consistency with Eppendorf Cell Culture Plates

Cleaning and Decontamination of the ept.i.p.s. Box

Automated Illumina TruSeq Stranded Total RNA library construction with the epmotion 5075t/TMX

Automated Illumina TruSeq Stranded mrna library construction with the epmotion 5075t/TMX

Comparative Analysis of Protein Recovery Rates in Eppendorf LoBind and Other Low Binding Tubes

The Value of Mixing. Eppendorf Temperature Control and Mixing Instruments

Color Compensation Set 1

Comparing the Microlab 600 to Volumetric Glassware and Air Displacement Pipettes. January 2013

Eppendorf SmartBlock. Instructions for use

Automated Illumina TruSeq DNA PCR-Free library construction with the epmotion 5075t/TMX

The Next Stage. The new Mastercycler X50

Technology that counts

Evaluating the functionality of Eppendorf BioPhotometer and Eppendorf BioSpectrometer using a Secondary UV-VIS Filter Set

Automation of Routine Microplate Pipetting and Dispensing

Trusted Partnership. Eppendorf CO2 Incubators: premium products with comprehensive support

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

The Basic Skills of the. Biotechnology Workplace

Technology that counts

First-Class Filter Tips

High-throughput Isolation of Genomic DNA From Buccal Swab on the Eppendorf epmotion 5075 VAC

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Easy Illumina Nextera DNA FLEX Library Preparation using the epmotion 5075t automated liquid handler

Automated pipetting made easy new ep Motion 5073 family members for perfect PCR set-up and nucleic acids purifi cation or general liquid handling

Carcino embryonic Antigen Human ELISA Kit

Inserting grids into capsule Removing capsules from grid box Immunolabeling using template guide Preparing for TEM insertion

New York State. Electronic Certificate of Need. HCS Coordinator. Overview. Version 1.0

Application for Radioactive Material Use

HPLC Sample Preparation

Technology that counts

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

Requirements to perform accurate dielectric material analysis

SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES

Exchangeable Thermoblock for slides DC Operating instructions

Peak of Perfection. Made for a faster and easier daily routine: Eppendorf Liquid Handling Consumables

Transcription:

Eppendorf Reference : The pipette. Reference class since 1994

Eppendorf Reference Reference class since 1994 The world of research and science is developing in shorter and shorter cycles. That s all for the better, because true constants are now available! Values you can always depend on. Of course, the Eppendorf Reference is one of them. As one of the most popular pipettes, it has been a constant companion for students, assistants, scientists and researchers since 1994. Eppendorf Reference s great success is based on its unique design and technology concept: the utmost precision and accuracy combined with low failure rate and high longevity. The ergonomic features also play a big role, making work more comfortable and safe for every user. Positive feedback from countless users has confirmed: The Eppendorf Reference remains the reference class for modern liquid handling tools. Even online: www.eppendorf.com/reference I remember my first few weeks in the lab like they were yesterday my very patient colleagues and my first pipette: the Eppendorf Reference. 2

A true companion Dependability and safety People who work in regulated areas or areas with high security requirements need an instrument with accordingly high reproducibility and dependability. With its control button and ejector combination, the Eppendorf Reference is designed to actively reduce contamination from aerosols. The one-button operation prevents gloves from becoming jammed in the device. The volume is set using the control button and always remains visible on the display no matter where the hand is positioned. A locking mechanism ensures that the settings cannot be changed accidentally. Of course, the Eppendorf Reference is fully autoclavable and the adjustment status is clearly indicated by the various calibration seals, thereby fulfilling all current laboratory guidelines. I never really understood what dependability meant until I had to replace my Reference with another pipette. 3

Listen to your hands Ergonomics and intuitive operation One of the most important reasons that many people choose to work with the Eppendorf Reference year after year is hard to explain but easily felt: Everyone who picks up the Eppendorf Reference notices right away: it has a great feel to it! It only has one control button and the volume can be easily read, regardless of the position of the hand. Everything works in a snap even changing the tips. The Reference not only meets the highest criteria of the Eppendorf PhysioCare Concept, it has been certified by the renowned TÜV Rheinland for its outstanding user friendliness! Changing hundreds of tips a day and keeping a smile on your face? No problem, thanks to the Eppendorf Reference! 4

Dependability with a system Pipette tips and service Do you depend on your precious samples? Then don t leave any valuable residues in your tips when you pipette solutions with detergents! Thanks to unique, innovative material handling, ept.i.p.s. LoRetention pipette tips re-dispense almost 100 % of the collected liquid ( pearl effect ), guaranteeing dependable, maximum reproducibility in your system with our Eppendorf Reference Pipette. The quality of your work results is significantly affected by the precision and accuracy of your pipette! epservices guarantees precisely that. The scope of services includes calibration, adjustment, certification, service and repair. It also includes low-cost BASIC calibration or GLP/GMP customer-specific calibration services. www.eppendorf.com/epservices www.eppendorf.com/consumables epservices for premium performance The Reference, ept.i.p.s and epservices system has become an essential part of my success story! 5

Reference class down to the last detail An overview of the Eppendorf Reference Catch Prevent unintentional volume adjustments 4-position volume display Precise volume setting Easy to read, regardless of pipetting style Combined dispensing button and tip ejection Active reduction of aerosol contamination No jamming of gloves Calibration seal Clear identification of the adjustment status Labeling area Optional individual labeling Color coding makes tip size easy to recognize Ergonomic tip ejection Low stress with frequent tip changes Volume labeling fast identification 6

TÜV-tested user friendliness Simple and ergonomic handling Perfect combination with ept.i.p.s. High reliability of results Made in Germany High quality standards Fully autoclavable Fast and secure disinfection Unique handle All individual hand positions possible Stopper No accidental rolling away 7

Eppendorf Reference Eppendorf Reference (variable) Volume range Volume Systematic Anthracite dispensing button for ept.i.p.s. 10 µl pipette tips Eppendorf Reference (fixed volume) Volume Systematic Random Order no. Gray dispensing button for ept.i.p.s. 20 µl pipette tips 1 µl ±2.5 % 1.8 % 4900 000.010 2 µl ±2.0 % 1.2 % 4900 000.028 5 µl ±1.5 % 0.8 % 4900 000.036 10 µl ±1.0 % 0.5 % 4900 000.044 Yellow dispensing button for ept.i.p.s. 200 µl pipette tips 10 µl ±1.0 % 0.5 % 4900 000.109 20 µl ±0.8 % 0.3 % 4900 000.117 25 µl ±0.8 % 0.3 % 4900 000.150 50 µl ±0.7 % 0.3 % 4900 000.125 100 µl ±0.6 % 0.2 % 4900 000.133 Random Order no. 0.1 2.5 µl 0.25 µl ±12.0 % 6.0 % 4910 000.085 1.25 µl ±2.5 % 1.5 % 2.5 µl ±1.4 % 0.7 % Gray dispensing button for ept.i.p.s. 20 µl pipette tips 0.5 10 µl 1 µl ±2.5 % 1.8 % 4910 000.018 5 µl ±1.5 % 0.8 % 10 µl ±1.0 % 0.4 % 2 20 µl 2 µl ±3.0 % 2.0 % 4910 000.026 10 µl ±1.0 % 0.5 % 20 µl ±0.8 % 0.3 % Yellow dispensing button for ept.i.p.s. 200 µl and 300 µl pipette tips 2 20 µl 2 µl ±5.0 % 1.5 % 4910 000.034 10 µl ±1.2 % 0.6 % 20 µl ±1.0 % 0.3 % 10 100 µl 10 µl ±3.0 % 0.7 % 4910 000.042 50 µl ±1.0 % 0.3 % 100 µl ±0.8 % 0.15 % 50 200 µl 50 µl ±1.0 % 0.3 % 4910 000.093 100 µl ±0.9 % 0.3 % 200 µl ±0.6 % 0.2 % Blue dispensing button for ept.i.p.s. 1,000 µl pipette tips 100 1,000 µl 100 µl ±3.0 % 0.3 % 4910 000.069 500 µl ±1.0 % 0.2 % 1,000 µl ±0.6 % 0.2 % Red dispensing button for ept.i.p.s. 2,500 µl pipette tips 500 2,500 µl 500 µl ±1.5 % 0.3 % 4910 000.077 1,000 µl ±0.8 % 0.2 % 2,500 µl ±0.6 % 0.2 % The data for systematic and random s only applies when using Eppendorf ept.i.p.s. pipette tips. Eppendorf Reference (fixed volume) Volume Systematic Random Order no. Blue dispensing button for ept.i.p.s. 1,000 µl pipette tips 200 µl ±0.6 % 0.2 % 4900 000.508 250 µl ±0.6 % 0.2 % 4900 000.540 500 µl ±0.6 % 0.2 % 4900 000.516 1,000 µl ±0.6 % 0.2 % 4900 000.524 Red dispensing button for ept.i.p.s. 2,500 µl pipette tips 1,500 µl ±0.6 % 0.2 % 4900 000.923 2,000 µl ±0.6 % 0.2 % 4900 000.907 2,500 µl ±0.6 % 0.2 % 4900 000.915 Your local distributor: www.eppendorf.com/worldwide Eppendorf AG 22331 Hamburg Germany Tel: +49 40 53801-0 Fax: +49 40 538 01-556 E-mail: eppendorf@eppendorf.com Eppendorf North America, Inc. 102 Motor Parkway Hauppauge, N.Y. 11788-5178 USA Tel: +1 516 334 7500 Toll free phone: +1 800-645-3050 Fax: +1 516 334 7506 E-mail: info@eppendorf.com Application Support Europe: Tel: +49 1803 666 789 (9 ct/min aus dem dt. Festnetz; Mobilfunkhöchstpreis 42 ct/min) support@eppendorf.com North America: Tel: +1 800 645 3050 E-mail: techserv@eppendorf.com Asia Pacific: Tel: +60 3 8023 6869 E-mail: support_asiapacific@eppendorf.com eppendorf, Eppendorf Reference, ept.i.p.s. and PhysioCare Concept are registered trademarks and epservices is a used trademark of Eppendorf AG. All rights reserved, including graphics and pictures. Copyright 2010 by Eppendorf AG. Order no. A491 012 020/GB1/10T/1210/FEEL/STEF Printed in Germany