SmartLine Radar Level Meter RM70

Similar documents
Reflex-Radar BM 100 A

ED 701 General Industry Pressure Transmitter

Certificate No.: IECEx BVS , issue 3 Annex Page 1 of 9

Pressure Transmitter ED 701

Fluid Cooling Industrial PF Series

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Conductivity sensor for hygienic applications

Tecnología en Electrónica y Control SRL Ficha Técnica

Target Insertion Flowmeter

VA Master FAM540 Metal Cone Variable Area Flowmeter

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Field IT 50T Series Transmitters

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

1 Overview. Pressure Measurement Transmitters for applications with basic requirements (Basic) SITRANS P310 - Technical description

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

ATEX/IECEx RTD temperature probe

DMHP3(4)L(T)2A00 Series

Full Metal Variable Area Flow Meter and Counter

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Exchangeable measuring insets SensyTemp TSA101

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

ISEmax CAM40/CAS40. Technical Information

Certificate No.: IECEx BVS issue No. 1 Annex Page 1 of 8 Subject and Type

Temperature sensors SensyTemp TSP311, TSP321, TSP331

VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.

98 Series Backpressure Regulators and Relief Valves

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

xce series & xjf EXPLOSIONPROOF ENCLOSURES EXPLOSIONPRROOF ENCLOSURES CERTIFICATIONS STANDARD FEATURES DESIGN OPTIONS MATERIAL ADALET.

SMV 3000 Smart Multivariable Flow Transmitter Specifications

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

General Specifications

Switches in conformity with ATEX directive

Metal Cone Variable Area Flowmeter VA Master FAM540

The 505F Series 3/4/5-Way Ball Valve. Standard Features and Benefits. Operating Conditions. Specifications. Options

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

ISEmax CAS40D. Technical Information

Z7A. Load cells. Special features. Data sheet. Wiring code

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.

STT 3000 Temperature Probe Assemblies Series STT830 - Threaded & Socket Weld Thermowell Assembly with Transmitter Option

CV3000 Series. Characterized Insert Control Valves

EX-EMERGENCY LIGHT FITTINGS

FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

GC005 thru GC600. Wireless Load Cell. Features. Applications. General Description. Load Cell

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2

IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

SMV 3000 Smart Multivariable Flow Transmitter

Type M4 - SON - SO - MS

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Vortex Flow Measuring System PROline prowirl 72

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Ex floating switches and Ex immersion probes

Direct-operated 2/2-way compact solenoid valves Type EV210A

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

507F. Multi-Port Sanitary Ball Valve. Full Port ISO 5211 Mounting Pad. For Automated & Manual Service. Pharmaceutical. Bio-Technology.

VARIABLE AREA FLOWMETERS

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Industrial Resistance Thermometers according to DIN Model MWD

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Solenoid valves 2/2-way direct-operated type EV210A

KOTRON RF SENSING PROBES. Worldwide level and flow solutions

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

Surface-mounting Thermostats ATH Type Series

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

Surface-mounting thermostats Series ATH

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

KOTRON RF SENSING PROBES. Worldwide level and flow solutions FEATURES AGENCY APPROVALS APPLICATIONS. A probe to satisfy each application

Type UB1 Load Cell. Option Stainless steel cable gland

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic

Transcription:

Page 1 of 5 SmartLine Radar Level Meter Model Selection Guide Reliable measurement in difficult process conditions +/- 3 mm / +/-0.12" standard accuracy Operates up to a flange temperature of 200 0 C / 390 0 F and 40 bar / 580 psig Measuring range up to 80 m / 260 ft. Long antenna versions can be extended to suit any nozzle length PACTware and DTMs included as standard Optional second current output Directly-accessible graphic touchscreen/wizard (optional) Converter rotates 360 0 Tripple barrier gas-tight protection available for working with dangerous gases (using pre-stressed fused glass) Instructions Select the desired key number. The arrow to the right marks the selection available. Make the desired selections from Tables I through V using the column below the proper arrow. A dot ( ) denotes availability. Table I I V - 4 _ Availability KEY NUMBER Description Selection TABLE I Level Meter Code 4 TABLE Approvals Material Process Connection and Antenna Antenna Antenna Extension 0 a ATEX G/D 1, 1/2, 2 Ex ia C T3...T6 2 a ATEX G/D 1/2, 2 Ex d[ia] C T3...T6 3 b FM IS CI. I Div. 1 Gr. A-G Dual Seal 6 c FM XP CI. I Div. 1 Gr. A-G Dual Seal 7 d ATEX 3G Ex na T3 T6 A a NEPSI Ex ia C T3...T6 E a NEPSI Ex d[ia] C T3...T6 F b CSA IS CI. I Div. 1 Gr. A-G Dual Seal H c CSA XP CI. I Div. 2 Gr. A-G Dual Seal K d IECEx Zone 0 Ex ia C T3 T6, Ex iad 20 M e IECEx Zone 0/1 Exd [ia] C T3 T6, Ex td [iad] A21/20 N b 316L / 1.4404 + Drop PTFE (40 bar) - Drop PP (16 bar) - Hygienic PEEK (10 bar) _ 0 _ Hastelloy C-22 / 2.4602 _ 1 _ f 316L / 1.4404 / 100 bar _ 2 _ g Hastelloy C-22 / 2.4602 / 100 bar _ 3 _ h Horn DN 80 dia. 75 mm (2.95 inch) - long 3 k Horn DN 40 dia. 39 mm (1.54 inch) - long 4 k Horn DN 50 dia. 43 mm (1.69 inch) - long 5 k Horn DN 80 dia. 75 mm (2.95 inch) - long - with purging system 6 k Horn DN 40 dia. 39 mm (1.54 inch) - long - with purging system 7 k Horn DN 50 dia. 43 mm (1.69 inch) - long - with purging system 8 k Horn DN 100 dia. 95 mm (3.7 inch) - long F k Horn DN 100 dia. 95 mm (3.7 inch) - long - with purging system G k PEEK Hygienic antenna (FDA conform) H l DROP PTFE DN 80 long ( Ø 75 mm / 2.95 inch) -50 C...+150 C P m DROP PP DN 80 long ( Ø 75 mm / 2.95 inch) -50 C...+100 C S n Sheet Metal Horn DN 80 dia. 75 mm (2.95 inch) - long U k Sheet Metal Horn DN 100 dia. 95 mm (3.7 inch) - long V k Sheet Metal Horn DN 80 dia. 75 mm (2.95 inch) - long - with purging system W k Sheet Metal Horn DN 100 dia. 95 mm (3.7 inch) - long - with purging system X k Extension 105 mm (4.13 inch) _ 1 _ Extension 210 mm (8.26 inch) _ 2 _ Extension 315 mm (12.4 inch) _ 3 _ Extension 420 mm (16.54 inch) _ 4 _ Extension 525 mm (20.67 inch) _ 5 _ Extension 630 mm (24.80 inch) _ 6 _ Extension 735 mm (28.94 inch) _ 7 _ Extension 840 mm (33.07 inch) _ 8 _ Extension 945 mm (37.20 inch) _ A _ Extension 1050 mm (41.34 inch) _ B _ Flange plate protection (PP drop) for DN 80/100, 3" & 4", 80A & 100A _ P _ o Flange plate protection (PP drop) for DN 150, 6" & 8" _ R _ p Flange plate protection (PTFE drop) for DN 80/100, 3" & 4", 80A & 100A _ S _ o Flange plate protection (PTFE drop) for DN 150, 6" & 8" _ T _ p

Page 2 of 5 TABLE Feedthrough / Temperature / Sealing Gasket TABLE I Process Connection EN Process Connection ASME Process Connection Other Output Standard / -40 C +150 C / FKM/FPM for Non Ex Drop antennas X s Standard / -50 C +150 C / EPDM for Non-Ex Drop antennas Y s Standard: -40 0 C (-40 0 F) +150 0 C (302 0 F), 40 bar (580 psi) max. / FKM/FPM 0 t Standard: -20 0 C (-4 0 F) +150 0 C (302 0 F), 40 bar (580 psi) max. / Kalrez 6375 1 t Dual: Metaglas / -30 0 C (-22 0 F) +150 0 C (302 0 F), 40 bar (580 psi) / FKM/FPM 2 t Dual: Metaglas / -20 0 C (-4 0 F) +150 0 C (302 0 F), 40 bar (580 psi) / Kalrez 6375 3 t Standard: -50 C...+150 C / EPDM 4 t Dual Metaglas: -30 C...+150 C / EPDM 5 t Standard/-20 C +150 C / Without for Tri-Clamp, SMS, DIN 11851 A q Standard/-20 C +150 C / EPDM for Bio Control B r Standard/-20 C +150 C / FKM/FPM for Bio Control C r Standard / -40 C...+200 C / FKM/FPM (distance piece included) F t Standard / -20 C...+200 C / Kalrez 6375 (distance piece included) G t Metaglas / -30 C...+200 C / FKM/FPM (distance piece included) H t Metaglas / -20 C...+200 C / Kalrez 6375 (distance piece included) K t Selection ailability G1 1/2" A ISO228 3 0 0 _ DN 40 PN 40 Form B1 EN1092 5 0 0 _ DN 50 PN 40 Form B1 EN1092 6 0 0 _ DN 80 PN 40 Form B1 EN1092 Be certain to confirm the 7 0 0 _ DN 100 PN 16 Form B1 EN1092 size of the antenna to the 8 0 0 _ DN 100 PN 40 Form B1 EN1092 size of the tank opening. A 0 0 _ DN 150 PN 16 Form B1 EN1092 While it is possible to use B 0 0 _ DN 150 PN 40 Form B1 EN1092 all of the combinations C 0 0 _ DN 50 PN 63 Form B1 EN1092 shown on this MSG as D 0 0 _ DN 80 PN 63 Form B1 EN1092 valid, certain antennas may E 0 0 _ DN 100 PN 63 Form B1 EN1092 need to be mounted via the F 0 0 _ DN 40 PN 63 / PN 100 Form B1 EN1092 inside of the vessel if the L 0 0 _ DN 50 PN 100 Form B1 EN1092 opening in the tank is not of M 0 0 _ DN 80 PN 100 Form B1 EN1092 a sufficient diameter. N 0 0 _ DN 100 PN 100 Form B1 EN1092 (distance piece included) P 0 0 _ DN 150 PN 63 Form B1 EN1092 (distance piece included) R 0 0 _ DN 150 PN 100 Form B1 EN1092 (distance piece included) S 0 0 _ 1 1/2" NPT 0 3 0 _ 1 1/2" 150 lb RF ASME B16.5 0 5 0 _ 1 1/2" 300 lb RF ASME B16.5 0 6 0 _ 2" 150 lb RF ASME B16.5 0 7 0 _ 2" 300 lb RF ASME B16.5 0 8 0 _ 3" 150 lb RF ASME B16.5 0 A 0 _ 3" 300 lb RF ASME B16.5 0 B 0 _ Be certain to confirm the 4" 150 lb RF ASME B16.5 0 C 0 _ size of the antenna to the 4" 300 lb RF ASME B16.5 0 D 0 _ size of the tank opening. 6" 150 lb RF ASME B16.5 0 E 0 _ While it is possible to use 8" 150 lb RF ASME B16.5 0 F 0 _ all of the combinations 6" 300 lb RF ASME B16.5 (distance piece included) 0 G 0 _ shown on this MSG as 1" 1/2 600 lb RF ASME B16.5 0 N 0 _ valid, certain antennas may 2" 600 lb RF ASME B16.5 0 P 0 _ need to be mounted via the 3" 600 lb RF ASME B16.5 (distance piece included) 0 R 0 _ inside of the vessel if the 4" 600 lb RF ASME B16.5 (distance piece included) 0 S 0 _ opening in the tank is not of 1.5" 900 lb / 1500 lb RF ASME B16.5 (distance piece included) 0 U 0 _ a sufficient diameter. 2" 900 lb / 1500 lb RF ASME B16.5 (distance piece included) 0 V 0 _ 3" 900 lb RF ASME B16.5 (distance piece included) 0 W 0 _ 4" 900 lb RF ASME B16.5 (distance piece included) 0 X 0 _ 10K 40A RF JIS B2220 0 0 5 _ 10K 50A RF JIS B2220 0 0 6 _ 10K 80A RF JIS B2220 0 0 7 _ 10K 100A RF JIS B2220 0 0 8 _ Bio Control DN 50 0 0 C _ Tri-Clamp 2" 0 0 F _ DIN 11851 DN 50 0 0 L _ SMS 51 0 0 P _ 1 Output 4 20mA (Hart) _ 0 2 Outputs 4 20mA (Hart) + 4 20mA _ 2 Foundation Fieldbus (4 wire + local HART) _ A Profibus PA (4 wire + local HART) _ D

TABLE Housing/Cable Entry/Cable gland Housing Option HMI (display & keys) Version No Selection TABLE V Calibration Certificates Construction Drawing / Tag Number 36-RM-16U-01 Page 3 of 5 Aluminum / M20 x 1.5 / without 0 Aluminum / 1/2" NPT / without 1 Aluminum / G 1/2" / without 2 Aluminum / M20 x 1.5 / Plastic (Non-Ex: black, Ex i: blue) 3 Aluminum / M20 x 1.5 / Metal (only for Ex d devices) 4 Stainless Steel / M25 x 1.5 / without A Stainless Steel / 1/2" NPT / without B Stainless Steel / M25 x 1.5 / plastic M20 (Non-Ex: Black, Exi blue) D Stainless Steel / M25 x 1.5 / metal M20 (only for Ex d devices) E _ 0 _ Weather Protection Option _ 2 _ - No Display 0 English 1 German 2 French 3 Italian 4 Spanish 5 Portugese 6 Japanese 7 Chinese (Mandarin) 8 Russian A Honeywell _ V _ 0 0 0 0 Calibration certificate 2 points 0 0 1 Calibration certificate 5 points (min. distance of 1.3 m (4.26 ft.)) 0 0 2 Without NACE MR 0175 / MR 0103 _ 3 _ 0 Tag No. stainless steel plate (1 line; 12 characters) 2

Page 4 of 5 RESTRICTIONS Restrictions Available only with Not Available with Letter Table Selection Table Selection a 4, E b I _ A, _ D 3, B, D c I 0 3 0 _, 0 5 0 _, 0 6 0 _, 0 7 0 _, 0 8 0 _, 0 A 0_, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 0 5 _, 0 0 6 _, 0 0 7 _, 0 0 8 _, _ 0, _ 2 U, V, W, X 2, 4, A, B, D, E d I 0 3 0 _, 0 5 0 _, 0 6 0 _, 0 7 0 _, 0 8 0 _, 0 A 0_, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 0 5 _, 0 0 6 _, 0 0 7 _, 0 0 8 _, _ 0, _ 2 U, V, W, X e f I 2, 3, A, B, D, E _ A, _ D 4, B, E H, P, S, 2, 3, 5, A, B, C, H, K, I 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P _, 6, 7, 8, G, H, P, S, _ P _, _ R _, _ S _, _ T _, A, B, C g I 5 0 0 _, 6 0 0 _, 7 0 0 _, 8 0 0 _, A 0 0 _, B 0 0 _, C 0 0 _, 0 5 0 _, 0 6 0 _, 0 7 0 _, 0 8 0 _, 0 A 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _,0 0 5 _, 0 0 6 _, 0 0 7 _, 0 0 8 _, 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P _ 6, 7, 8, G, H, P, S, A, B, C h I 5 0 0 _, 6 0 0 _, 7 0 0 _, 8 0 0 _, A 0 0 _, B 0 0 _, C 0 0 _, 0 5 0 _, 0 6 0 _, 0 7 0 _, 0 8 0 _, 0 A 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _, 0 0 5 _, 0 0 6 _, 0 0 7 _, 0 0 8 _, 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P P _, _ R _, _ S _, _ T _ k A, B, C, X, Y I 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P _

Page 5 of 5 I 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P _ m I, _ 1 _, _ 2 _, _ 3 _, _ 4 _, _ 5 _, _ S _, _ T _ 3 0 0 _, 7 0 0 _, 8 0 0 _, A 0 0 _, B 0 0 _, C 0 0 _, 0 A 0 _, 0 3 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _, 0 0 7 _, 0 0 8 _, _ 1 _, _ 2 _, _ 3 _, _ 4 _, _ 5 _, _ P _, _ R _ n I 3 0 0 _, 7 0 0 _, 8 0 0 _, A 0 0 _, B 0 0 _, C 0 0 _, 0 3 0 _, 0 A 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _, 0 0 7 _, 0 0 8 _ o I 7 0 0 _, 8 0 0 _, A 0 0 _, 0 A 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 0 7 _, 0 0 8 _ p I B 0 0 _, C 0 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _ q r I I 0 0 F _, 0 0 L _ 0 0 C _ s 0 _ P, 0 _ S t 0 _ P, 0 _ S