Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Similar documents
The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Application Note S/SL

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Virtually Particle-Free Rt -Silica BOND Columns

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

Combustible Gas Catalytic Bead (0-100 %LEL) Part No FM Performance Certified 1,4 FM Performance Certified 1

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Thermo Scientific Prima PRO Process Mass Spectrometer

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

2Fe 2 O 3 +3H 2 S FeS+FeS x +S+3H 2 O

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Muliple Gas#3 plus Sulfur GC Configuration

An alcohol is a compound obtained by substituting a hydoxyl group ( OH) for an H atom on a carbon atom of a hydrocarbon group.

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

Petrochemical. Transformer Oil Gas Analysis - TOGA

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

The Claviature of Gas Analysis

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Dimethyl ether (DME) for fuels Determination of impurities Gas chromatographic method

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions

Pellistor Relative Responses

Polymer plants continue to seek ways to increase production and efficiency without compromising safety.

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Appendix A Physical and Critical Properties

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

Methanol Extraction of high level soil samples by USEPA Method 8260C

Application Note 032

Analytical methods for hydrogen fuel QC Thomas Bacquart, Sam Bartlett, Abigail S.O. Morris, Nick Allen, Arul Murugan

Organic Chemistry. REACTIONS Grade 12 Physical Science Mrs KL Faling

PROCESS AND ENVIRONMENTAL APPLICATIONS OF GAS CHROMATOGRAPHY WITH THE REDUCTION GAS DETECTOR

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Headspace Technology for GC and GC/MS: Features, benefits & applications

Analytical Trap Comparison for USEPA Method 8260C

CH0204 Organic Chemical Technology

SERVOTOUGH SpectraScan

Exploring US EPA Method 524 Purge and Trap Variables: Water Vapor Reduction and Minimizing Cycle Time

Technical/Application Article 01 Version 1.2

PETE 203: Properties of oil

Safety Manual > Incompatible Chemicals Partial Listing

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

PROCESS TECHNOLOGY- ORGANIC II. 51. Gas phase dehydrogenation of ethyl-benzene to styrene occurs over catalyst based on

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Reprinted from February Hydrocarbon

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas

Introduction. David B. Wurm, Kefu Sun, and William L. Winniford. Abstract

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Organic Chemistry. Organic chemistry is the chemistry of compounds containing carbon.

8 Materials, Corrosion Resistance Tables

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1

Far UV Absorbance Detector

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Aromatic Hydrocarbons

Chemistry 110. Bettelheim, Brown, Campbell & Farrell. Ninth Edition

Making Improvements to Today s Natural Gas Analysis Systems

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Molecular Models and Isomerism

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

Chemical Polyurethane Polyethelyne PVC Nylon 11 Kynar

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

LCT. Detailed Crude Oil Analysis: Processes for the future

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

SUPPLEMENTAL HOMEWORK SOLUTIONS WEEK 10

INCOMPATIBILITY BETWEEN CHEMICALS

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Chapter 4: Carbon and the Molecular Diversity of Life. 1. Organic Molecules 2. Chemical Groups

* Institut FranGais du PCtrole, 1 et 4 avenue de Bois PrCau, BP 311, Rueil-

1. Organic Molecules. Elements in Biological Molecules 2/13/2016. Chapter 4: Carbon and the Molecular Diversity of Life

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

UV3000. Accurate, precise, and portable ambient gas point analyzer

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

GC Columns PLOT Columns

CHAPTER 24 Organic Chemistry

Module: 7. Lecture: 36

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy

STANDARD OPERATING PROCEDURES

A Micro-GC Based Chemical Analysis System

LABORATORY SAFETY PLAN APPENDIX

Maximizing Sample Throughput In Purge And Trap Analysis

Introduction to Alkyl Halides, Alcohols, Ethers, Thiols, and Sulfides

Volatile Organic Compounds in Every Day Food

Balancing chemical reaction equations (stoichiometry)

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Agilent Intuvo 9000 Gas Chromatograph System

Abstract. Introduction

Module: 7. Lecture: 36

Chemical Storage According to Compatibility

Transcription:

Monomer Analysis Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION

Polymer Grade Monomer Analysis Monomer Analysis Impurities in feedstocks can adversely affect the quality of the final polymer, cause irreversible catalyst poisoning, and lead to costly plant downtime. Our customers enjoy the benefits of the turn-key systems that we provide on the Agilent latest platform. The analyzers are completely developed including the installation of all valving, additional heated zones, and analytical columns. The analytical method is tested using certified calibration blends. We then deliver, install, and provide training on the application. Monomer Solutions GC/MS/PDHID Solutions Dual FID's Solutions The instrument and analytical performance of our turn-key systems are guaranteed for one year. SCD/NCD Solutions Monomer Solutions by Application Number Matrix Impurities Ethylene Propylene Hydrocarbons Trace CO / CO2 Oxygenates Sulfurs Perm Gases w/ Hydrogen Arsine / Phosphine Ammonia 260 261 Applications 262 253 410 660 670 460 460B 462 462B WASSON - ECE INSTRUMENTATION Monomers

Polymer Grade Monomer Analysis The Turn-key Analytical Concept pa 50000 The analyzer is completely developed including valves, additional heated zones, and analytical columns. 40000 The chromatography is tested using certified calibration blends. 30000 20000 The gas chromatograph is delivered to the customer's facility. 10000 A service engineer comes to the customer s site to perform installation and training. 0 5 5 7.5 10 15 15 17.5 20 Complete Monomer Solution min The instrument guarantee covers all parts and analytical performance during the first year. Monomer Solutions Wasson-ECE provides turn-key solutions for the following monomers: Ethylene Propylene 1-Butene Isobutylene 1,3-Butadiene Vinyl chloride monomer Styrene All of our systems are built to order, so that we can meet your specific analytical needs. Ph. 970.229179 www.wasson-ece.com

Applications 26X Monomer Analysis by FID App 26X: Hydrocarbons FID 1 detects trace hydrocarbon impurities in the monomer matrix. Separation is accomplished using a high resolution PLOT column with a proprietary phase. Ethylene Matrix 5. 6. 7. 9. Methane Ethane 3. Propane 4. Propylene 5. Acetylene 6. Isobutane 7. Propadiene 8. n-butane 9. cis-2-butene 10 Methylacetylene 3. 4. 8. 10. The 26X Family of Analyses Application 260 - Impurities in Ethylene 2 4 6 8 10 12 14 16 Application 261 - Impurities in Propylene Application 262 - Impurities in Ethylene and Propylene Why Utilize the 26X Applications? All components are analyzed in a single run. You can choose to analyze ethylene, propylene, or both on the same instrument, depending on your analytical requirements. App 26X: FID/Methanizer Carbon Monoxide Methane 3. Carbon Dioxide Methane Ethane 3. Propane 3. 4. Propylene 5. Acetylene 6. Isobutane 7. Propadiene 8. n-butane 9. cis-2-butene 10 Methylacetylene FID 2 detects trace carbon monoxide, methane, carbon dioxide, and acetylene (in propylene only) to a lower quatifiable limit of 50 ppb. A methanizer is used for the analysis of carbon monoxide and carbon dioxide. 2 1 4 2 6 8 3 10 4 12 145 16 6 WASSON - ECE INSTRUMENTATION Monomers

Application 253 Oxygenate Analysis by FID 3,4 5. 6. 10. 1 Dimethyl Ether ETBE 3. MTBE 4. DIPE 5. SBME 6. TAME 7. Methanol 8. Acetone 9. Ethanol 10. iso/n-propanol Comp 1 iso/2-butanol Comp 1 t-butanol 13. n-butanol 14. TAA Application 253: Oxygenates The FID detects trace oxygenates in ethylene, propylene, butane/butenes, gasoline and naphtha. The lower quantifiable limit for this analysis is 4 ppm. 8. 9, 1 13. 14. 7. 10 15 20 25 30 35 Application 410 Analysis by PDHID 3. 4. 6. Hydrogen Argon 3. Oxygen 4. Nitrogen 5. Methane 6. Air/Methane Composite 7. Carbon Dioxide 8. Carbon Monoxide Application 410: PDHID A Valco pulsed discharge helium ionization detector (PDHID) detects hydrogen, argon, oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide to a lower quantifiable limit of 200 ppb. 5. 7. 8. 2 4 6 8 10 Ph. 970.229179 www.wasson-ece.com

Applications 46X Monomer Analysis by MSD 3. t-butanol, 15.5 ppm Isopropanol, 2 ppm 3. sec-butanol, 15.6 ppm 4. n-propanol, 5 ppm 5. n-butanol, 9.4 ppm Oxygenates Analysis by MSD The MSD detects alcohols to a lower quantifiable limit of 0.05 ppm. 5. 4. 4.00 6.00 8.00 10.00 100 14.00 16.00 18.00 20.00 Selective Ion Mode Maximizes Sensitivity! Methyl Mercaptan, 6 ppm Methanol, 2 ppm MeSH and MeOH Analysis The MSD detects methyl mercaptan and methanol is achieved to a lower quantifiable limit of 0.05 ppm. 4.00 5.00 6.00 7.00 8.00 9.00 10.00 100 100 Ph. 970.229179 www.wasson-ece.com

Applications 46X Monomer Analysis by MSD The 46X Family Analyses The 46X family uses three different methods to analyze for a variety of species. Method 1 uses a mass spec detector (MSD) to detect oxygenates and mercaptans to a lower quantifiable limit of 0.05 ppm. This is achieved by using selective ion mode on the MSD to maximize sensitivity. Monomer Analysis by MSD allows for maximum flexibility The 46X applications allow the user to identify a large variety of monomer impurities on one instrument. The 46X family of applications combines the MSD with the Valco PDHID to allow even greater analysis power. The 46X Family of Monomer Analysis On-Board Vaporizer Converts propylene liquid to the gas phase prior to injection. Application 460 - Impurities in Propylene by MSD Application 460B - Impurities in Ethylene and Propylene by MSD Appication 462 - Impurities in Propylene by MSD/PDHID Application 462B - Impurities in Ethylene and Propylene by MSD/PDHID Application 46X: MS Analysis 3. MTBE, 5 ppm Ethyl Mercaptan, 4 ppm 3. Dimethyl Sulfide, 5 ppm 4. Diethyl Sulfide (wet needle) 5. Isopropanol, 2 ppm 6. Ethanol, 7 ppm 7. n-propanol, 5 ppm 8. n-butanol, 4 ppm 8. The 46X GCMS analysis of MTBE, ethyl mercaptan, dimethyl sulfide, diethyl sulfide, isopropanol, ethanol, n-propanol, and n-butanol. 5. 7. 6. 4. 4.00 6.00 8.00 10.00 100 14.00 16.00 18.00 20.00 WASSON - ECE INSTRUMENTATION Monomers

Applications 46X Monomer Analysis by FID/MS/PDHID Light Sulfurs Analysis Carbonyl Sulfide, 1 ppm Hydrogen Sulfide, 4 ppm Method 2 utilizes the MSD selective ion mode to detect carbonyl sulfide and hydrogen sulfide to a lower quantifiable limit of 0.05 ppm. 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 Phosphine, 5.3 ppm Arsine, 9.8 ppm Arsine/Phosphine Analysis The MSD selective ion mode allows the detection of arsine and phosphine to a lower quantifiable limit of 0.05 ppm. 3.00 4.00 5.00 6.00 7.00 8.00 9.00 WASSON - ECE INSTRUMENTATION Monomers

Applications 660/670 Sulfur and Nitrogen Analysis by SCD/NCD Methanethiol Ethanethiol 2-Propanethiol 2-Methyl-2-Propanethiol 1-Propanethiol Thiophene Diethyl Sulfide 1-Butanethiol Dimethyl Disulfide Diethyl Disulfide Bromothiophene Benzenethiol Benzothiophene Diphenyl Sulfide App 660: Sulfur Detection An Agilent Technologies Sulfur Chemiluminescence Detector (SCD) is configured for sulfur speciation. The SCD is an equimolar detector with a lower quantifiable limit of 20 ppb. Why Utilize the 660/670? The Agilent Chemiluminscence family of detectors provide sulfur and nitrogen specific analyses, avoiding the problem of hydrocarbon interference experienced by other types of detectors. Ammonia App 670: Ammonia Detection An Agilent Technologies Nitrogen Chemiluminescence Detector (NCD) is configured to perform the analysis of trace ammonia in ethylene to a lower quantifiable limit of 50 ppb. 5 5 7.5 10 15 15 17.5 20 25 Ph. 970.229179 www.wasson-ece.com

Calibration The dynamic blender is a portable blending device that dilutes a sample or a certified standard with a matrix gas of choice. The device can blend both liquids and gases. An inert flow path and heated bridge eliminate adsorption and condensation problems when blending gas standards that include sulfur, nitrogen, and other reactive compounds. The samples are fed directly to a gas chromatograph, eliminating the need to store multiple gas samples. The dynamic blender may optionally contain a digital flow controller that allows the diluent gas to be controlled digitally. The Wasson-ECE Dynamic Blender provides reliable point-of-use calibration blends. The on-board vaporizer allows the user to dilute and vaporize heavy liquid samples into the gas phase. The dynamic blender then delivers the sample to the gas chromatograph for reliable calibration. The final concentration is a function of the flow rates of the sample and the diluent gas. WASSON - ECE INSTRUMENTATION Monomers

Wasson-ECE Instrumentation Engineered Solutions, Guaranteed Results. Wason-ECE Instrumentation specializes in configuring and modifying new or existing gas chromatographs exclusively from Agilent Technologies to become guaranteed, turn-key analytical systems. Our customers describe their objectives and their samples: analytes, concentration ranges, phases, temperature, throughput, and any special needs. From this dialog we configure a task specific instrument. We add extra ovens, valves, plumbing, flow control, columns, electronics, and software to yield a complete solution. This saves our clients valuable time and delivers instruments that are state-of-the-art and ready for use upon installation. The complete analytical method is developed, tested, and documented utilizing our experience working with numerous companies that have similar needs and goals. The resulting chromatograms and reports are inspected by our application chemists and you, to ensure system performance and design quality. Our field engineers then install each system and provide training. After installation, and throughout the life of the chromatograph, our support chemists are ready to help. We can assist with application details, questions, training, calibration, maintenance, and on-site service. Wasson-ECE brings experience and efficiency to your project, giving you confidence in the quality of your results. Ph. 970.229179 www.wasson-ece.com

Please contact us for more information Engineered Solutions, Guaranteed Results. Ph. 970.229179 Fx. 970.229364 www.wasson-ece.com sales@wasson-ece.com