Experimental Investigation of the Performances of a WRS-BTU Seismic Isolator

Similar documents
Wire rope springs for passive vibration control of a light steel structure

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS

Dynamic Tests on Ring Shear Apparatus

Experimental Analysis of the Relative Motion of a Gear Pair under Rattle Conditions Induced by Multi-harmonic Excitation

Step 1: Mathematical Modeling

T1 T e c h n i c a l S e c t i o n

Boundary Nonlinear Dynamic Analysis

Dynamics of structures

Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events

A new seismic testing method E. Kausel Professor of Civil and Environmental Engineering, Massachusetts 7-277, OamWd^e, ^ 027 JP,

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

A Sloping Surface Roller Bearing and its lateral Stiffness Measurement

LANMARK UNIVERSITY OMU-ARAN, KWARA STATE DEPARTMENT OF MECHANICAL ENGINEERING COURSE: MECHANICS OF MACHINE (MCE 322). LECTURER: ENGR.

Seismic design of bridges

Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane

Equilibrium of a Particle

Experimental characterization of dry friction isolators for shock vibration isolation

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

REAL-TIME HYBRID EXPERIMENTAL SIMULATION SYSTEM USING COUPLED CONTROL OF SHAKE TABLE AND HYDRAULIC ACTUATOR

EXPERIMENTAL VALIDATION OF RE-CENTRING CAPABILITY EVALUATION BASED ON ENERGY CONCEPTS

LECTURE 12. STEADY-STATE RESPONSE DUE TO ROTATING IMBALANCE

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

SHAKING TABLE DEMONSTRATION OF DYNAMIC RESPONSE OF BASE-ISOLATED BUILDINGS ***** Instructor Manual *****

SEISMIC BASE ISOLATION

Fundamental study on simple quantitative approach of damping performance for semi-active damper

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE SCHOOL OF ENGINEERING

Model tests and FE-modelling of dynamic soil-structure interaction

MOOC QP Set 2 Principles of Vibration Control

Preliminary Examination - Dynamics

1338. Experimental and numerical studies on multi-spherical sliding friction isolation bearing

Contents. Dynamics and control of mechanical systems. Focus on

International Journal of Advance Engineering and Research Development

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

KINETIC EEFCT ON FLEXIBLE BODIES BEHAVIOR

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

Dynamics and control of mechanical systems

STUDY ON THE RESPONSE OF ELASTOMERIC BEARINGS WITH 3D NUMERICAL SIMULATIONS AND EXPERIMENTAL VALIDATION

Stockbridge-Type Damper Effectiveness Evaluation: Part II The Influence of the Impedance Matrix Terms on the Energy Dissipated

Active elastomer components based on dielectric elastomers

R-Plus System Frontespizio_R_PlusSystem.indd 1 11/06/ :32:02

REPRODUCTION OF A LARGE-SCALE 1G TEST ON UNSATURATED SAND DEPOSITS AND PILE FOUNDATIONS USING CENTRIFUGE MODELING

Theory of Vibrations in Stewart Platforms

Inclusion of a Sacrificial Fuse to Limit Peak Base-Shear Forces During Extreme Seismic Events in Structures with Viscous Damping

CONSIDERATIONS ON THE NON-LINEAR MODELLING OF THE DYNAMICS OF THE VIBRATION AND SHOCK ISOLATORS MADE FROM COMPOSITE NEOPRENE

DEVELOPMENT OF A REAL-TIME HYBRID EXPERIMENTAL SYSTEM USING A SHAKING TABLE

A Guide to linear dynamic analysis with Damping

ANALYTICAL MODEL FOR HIGH DAMPING ELASTOMERS APPLIED TO ENERGY DISSIPATING DEVICES. NUMERICAL STUDY AND EXPERIMENTAL VALIDATION

Damping from bearing hysteresis in railway bridges

SAMCEF For ROTORS. Chapter 1 : Physical Aspects of rotor dynamics. This document is the property of SAMTECH S.A. MEF A, Page 1

Junya Yazawa 1 Seiya Shimada 2 and Takumi Ito 3 ABSTRACT 1. INTRODUCTION

STRUCTURAL DYNAMICS BASICS:

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

The basic dynamic load rating C is a statistical number and it is based on 90% of the bearings surviving 50 km of travel carrying the full load.

Cyclic behaviour of a reinforced concrete braced frame with high damping rubber devices

2.003 Engineering Dynamics Problem Set 10 with answer to the concept questions

Special edition paper

Introduction to Mechanical Vibration

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Preliminary Examination in Dynamics

(Refer Slide Time: 1: 19)

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

University of Bristol - Explore Bristol Research. Publisher's PDF, also known as Version of record

This equation of motion may be solved either by differential equation method or by graphical method as discussed below:

Modelling Seismic Isolation and Viscous Damping

Development of Spherical Sliding Bearing

Pseudo-dynamic tests in centrifugal field for structure-foundation-soil systems

NATIONAL CERTIFICATE (VOCATIONAL) APPLIED ENGINEERING TECHNOLOGY NQF LEVEL 4 NOVEMBER 2009

Evaluation of dynamic behavior of culverts and embankments through centrifuge model tests and a numerical analysis

MECHANICS OF STRUCTURES SCI 1105 COURSE MATERIAL UNIT - I

Selection Calculations For Linear & Rotary Actuators

IDENTIFICATION OF FRICTION ENERGY DISSIPATION USING FREE VIBRATION VELOCITY: MEASUREMENT AND MODELING

Structural Dynamics Lecture 4. Outline of Lecture 4. Multi-Degree-of-Freedom Systems. Formulation of Equations of Motions. Undamped Eigenvibrations.

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

A nonlinear dynamic vibration model of defective bearings: The importance of modelling the finite size of rolling elements

Engineering Mechanics Prof. U. S. Dixit Department of Mechanical Engineering Indian Institute of Technology, Guwahati Introduction to vibration

CHAPTER 5 QUASI-STATIC TESTING OF LARGE-SCALE MR DAMPERS. To investigate the fundamental behavior of the 20-ton large-scale MR damper, a

Vibration Control Prof. Dr. S. P. Harsha Department of Mechanical & Industrial Engineering Indian Institute of Technology, Roorkee

Class XI Physics Syllabus One Paper Three Hours Max Marks: 70

TOPIC E: OSCILLATIONS EXAMPLES SPRING Q1. Find general solutions for the following differential equations:

VIBRATION ANALYSIS OF E-GLASS FIBRE RESIN MONO LEAF SPRING USED IN LMV

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil

666. Controllable vibro-protective system for the driver seat of a multi-axis vehicle

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

ROLLER BEARING FAILURES IN REDUCTION GEAR CAUSED BY INADEQUATE DAMPING BY ELASTIC COUPLINGS FOR LOW ORDER EXCITATIONS

Modeling, Control and Experimental Validation of a Device for Seismic Events Simulation

Modeling of the hysteretic dynamic behavior of the Stockbridge messenger cables

Final Exam April 30, 2013

ON THE MODELING OF SELF-DAMPING IN STRANDED CABLES

Improving the earthquake performance of bridges using seismic isolation

Experimental and Analytical Study of the XY-Friction Pendulum (XY-FP) Bearing for Bridge Applications

FRICTION SLIPPING BEHAVIOR BETWEEN CONCRETE AND STEEL -AIMING THE DEVELOPMENT OF BOLTED FRICTION- SLIPPING JOINT -

Dynamics of Machinery

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

COLUMN BASE WEAK AXIS ALIGNED ASYMMETRIC FRICTION CONNECTION CYCLIC PERFORMANCE


Q1. Which of the following is the correct combination of dimensions for energy?

MOOC QP Set 1 Principles of Vibration Control

Analysis and Experiments of the Linear Electrical Generator in Wave Energy Farm utilizing Resonance Power Buoy System

VERIFICATION TEST AND EARTHQUAKE RESPONSE OBSERVATION OF A BASE ISOLATED BUILDING WITH ECCENTRIC ROLLER BEARINGS

Nonlinear Rolling Element Bearings in MADYN 2000 Version 4.3

Transcription:

, July 3-5, 2013, London, U.K. Experimental Investigation of the Performances of a WRS-BTU Seismic Isolator R. Brancati, G. Di Massa, S. Pagano, E. Rocca and S. Strano Abstract This paper describes an experimental investigation conducted on WRS-BTU seismic isolators that are constituted by a wire rope spring coupled with a ball transfer unit. The device can be considered rigid along the vertical direction while the horizontal stiffness can be independently chosen to shift the natural period away from the period range having the most of earthquake energy. Two kinds of tests were carried out: the first ones regard the isolator characterization; then, to evaluate the isolation efficiency, a small laboratory structure was uipped with four isolators and several tests on a shake-table were performed. Index Terms Seismic isolators, nonlinear dynamics, wire rope, hysteresis. shake-table tests, I. INTRODUCTION new type of seismic isolator was developed and Arealized at the Department of Industrial Engineering (DII) of the University of Naples Federico II; it is constituted (Fig.1) by the coupling of a ball transfer unit (BTU) with a wire rope spring (WRS). Fig. 1. WRS-BTU isolator. horizontal direction with low friction. Fig. 2. Ball Transfer Unit (BTU) scheme. The isolator restoring force is provided by a wire rope spring (WRS) constituted by several ropes connecting the two plates of the device. WRSs are widely adopted in industrial field as they are particularly effective in vibration isolation and energy absorption. In fact they dissipate energy through friction forces acting among the wires of each rope due to their relative movement; the produced thermal energy is easily exchanged with the environment thanks to favourable heat exchange surface of the ropes. Compared with the elastomeric seismic isolators, WRSs have a longer service life since they are not very sensitive to temperature changes and resists aggressive environments caused by the presence of ozone, oil, grease and salt spray. The most common WRS are helical type (Fig. 3a) or circular type (Fig. 3b). These springs are sometimes called cable isolators even if the term cable generally refers to a flexible tension member (rope) which, in addition to a strength member, includes power and/or signal conductors within its structure. BTU is an omni-directional load-bearing spherical balls mounted inside a restraining fixture, having the task to bear the structure weight with a neglecting vertical deformation (Fig.2); it allows the structure to translate along any R. Brancati is with the Dipartimento di Ingegneria Industriale, Università degli Studi di Napoli Federico II, 80125 ITALY, (e-mail: renato.brancati@unina.it). G. Di Massa is with the Dipartimento di Ingegneria Industriale, Università degli Studi di Napoli Federico II, 80125 ITALY, (e-mail: giandomenico.dimassa@unina.it). S. Pagano is with the Dipartimento di Ingegneria Industriale, Università degli Studi di Napoli Federico II, 80125 ITALY, (e-mail: pagano@unina.it). E. Rocca is with the Dipartimento di Ingegneria Industriale, Università degli Studi di Napoli Federico II, 80125 ITALY, (e-mail: erocca@unina.it). S. Strano is with the Dipartimento di Ingegneria Industriale, Università degli Studi di Napoli Federico II, 80125 ITALY, (corresponding author, phone:+390817683277; e-mail:salvatore.strano@unina.it). Fig. 3. Commercial wire rope spring. The WRS-BTU isolator can be obtained by coupling the two main component, not necessarily integrated into a unique support; the two main component can be chosen in function of the vertical load acting on the BTU and of the WRS horizontal stiffness ruired to shift the natural period away from the period range having the most of earthquake energy; the choices are facilitated by the numerous technical

, July 3-5, 2013, London, U.K. catalogues available on the web and no additional costs are ruired for the device characterization. The WRS-BTU prototype [1, 2], developed at the DII, adopts a simple WRS characterized by the possibility to easily change the rope length or the ropes with others having different diameter or rope configuration. WRSs provide a restoring force due to the deflection of the ropes; if the upper plate is in the centred position the ropes, are stressed by bending moment due to the curvature imposed during isolator assembly (Fig. 4a). With reference to Fig. 4b, it can be noted that an upper plate displacement along the x direction, induces: - torque and bending in the y-ropes; - a change of the curvature of the x-ropes that induces an increase or a decrease of the bending moment depending on the length of the rope. While the additional deflection of y-ropes induces a positive restoring force, the change of the bending moment in x-ropes can even determine a set of forces that take away the plate from the central position if the rope is long enough (negative stiffness). Shortening the rope the bending stiffness becomes positive and all the ropes contribute to recentre the upper plate. II. BTU FRICTION The isolator is constituted by 8 cables; each one has a length of 90mm and a the diameter of 5mm. To characterize the friction coefficient of the BTU, some tests were performed on a bi-axial press (Fig. 5). The apparatus consists of a 800kN hydraulic press uipped with a slide that can translate on two linear duct trolleys and rails in a horizontal direction. A mechanical actuator moves the slide with a harmonic motion of assigned amplitude and fruency. The instrumentation enables the slide position and the force transmitted by the actuator to be detected. The tests were conducted by fixing the lower plate onto the horizontal slide and the upper one to a vertical slide onto which the vertical load is applied. A horizontal direction harmonic movement with an amplitude of 20 mm (i.e. a stroke of 40 mm) and a fruency of 0.05Hz was applied. To characterize the BTU rolling resistance, the isolator without wire ropes was fixed onto the bi-axial press and, by superimposing the above defined harmonic motion, the horizontal force was detected; the contribution exerted by the BTU was obtained subtracting the slide friction force previously determined detecting the force ruired to move the slide with different masses fixed on the slide. The tests were conducted for two different levels of rolling surface mechanical finishing. BTU y-rope x-rope x BTU y-rope x-rope Fig. 4. Bending deflection of the ropes. The BTU was mounted in ball-up configuration, i.e. with the main ball in contact with the intrados of the upper plate so that dust or debris cannot settle on the rolling surface and cannot affect the regular rolling of the ball. The isolator is characterized by a hysteretic non-linear behavior. In this case, specific hysteresis model able to describe its behaviour must be adopted [3]. The present paper describes some tests conducted at the DII; the first set of test regards the isolators characterization and hence the friction force exerted by the BTU and the force-displacement diagram obtained superimposing and a periodic relative horizontal displacement with a constant vertical load. To verify the insulation efficiency, a light structure was realized and was insulated by means of four WRS-BTU isolators. The experimental tests were conducted by fixing the structure on the moving platform of the shake-table developed at the DII. It is driven by a servo-hydraulic actuator able to simulate a wide range of simulated ground motions including the reproductions of recorded earthquakes time-histories. Fig. 5. Isolator on the bi-axial press for the BTU friction coefficient evaluation. Friction coefficient 0,07 0,06 0,05 0,04 0,03 0,02 0,01 0 100 200 300 400 500 600 700 800 900 Fig. 6. Isolator on the bi-axial press. Vertical load [N] finished surface (Ra=1.5) not finished surface Fig. 6 shows the results of the two tests. The upper curve represents the "rough rolling surface (without surface finishing) whereas the lower one was obtained with a surface roughness of approximately Ra = 1.5. III. SHEAR TESTS ON THE WRS-BTU ISOLATOR The shear tests were performed using the isolator testing machine (BPI) available at the DII laboratory (Fig. 7). The BPI mainly consists of a movable horizontal platform driven by a hydraulic actuator that allows to impose periodic shear

Proceedings of the World Congress on Engineering 2013 Vol III,, July 3-5, 2013, London, U.K. deformations to the device under test, simultaneously loaded with a constant vertical compression [4]. The platform motion is constrained to a single horizontal axis by means of recirculating ball-bearing linear guides. The removal of the reaction structures (Fig. 7) allows the testing machine to be used as a shake-table able to verify the seismic performances of isolated structures [5]. Since the BPI was designed to characterize more rigid isolators [6, 7, 8], the sensitivity of the load cell and the friction forces of the platform linear guides do not allow to make accurate investigation for the isolator described in the present paper. Two hysteresis cycles, for different deformation amplitudes, same fruency and without the BTU contact, are reported in Fig. 10. The results reported in Fig. 11 show the influence of the excitation fruency on the restoring force. Also in this case the cycles were obtained without the BTU contact. Fig. 9. Scheme of the system adopted to measure the isolator restoring force. Fig. 7. Isolator testing machine (BPI). For this reason a suitable device was realized (Figs. 8 and 9) constituted by a slide horizontally connected to the BPI platform by means of a load cell and vertically supported by four BTUs; the slide is laterally guided by two couples of rolling bearing. When the BPI platform moves, the isolator restoring force is obtaining by the load cell force measurement, subtracting the slide inertia force and the friction force, exerted by the four supporting BTUs. The inertia force is given from the measurement of the slide horizontal acceleration and the knowledge of the slide mass Fig. 10. Hysteresis cycles, f=0.5 Hz, A=0.02 m (dashed line), A=0.04 m (solid line), without BTU contact. Fig. 8. Slide on the BPI platform. Fig. 11. Hysteresis cycles, A=0.04 m, f=0.1 Hz (dashed line), f=1 Hz (solid line), without BTU contact. Figs. 10, 11 and 12 show the results of some tests carried out by imposing sinusoidal shear deformation for different values of fruency (f) and amplitude (A). Moreover, the tests were conducted with and without the BTU contact in order to appreciate its effect on the restoring force. Two hysteresis cycles, executed with the same deformation low but without and with the BTU contact, are shown in Fig. 12. The tests were performed adopting a vertical load of 1220 N, smaller than the maximum allowed, ual to 1400 N.

, July 3-5, 2013, London, U.K. ξ 2ΔW. (3) 2 π k ( d d ) max min Fig. 12. Hysteresis cycles, A=0.03 m, f=0.1 Hz, without BTU contact (dashed line), with BTU contact (solid line). The detected cycles show that the device has a hardening behaviour and the hysteresis cycle area increases with the forcing fruency. To study the isolator dynamic properties, the nonlinear energy dissipation represented by the preview hysteresis cycles was approximated with the one corresponding to an uivalent linear spring-damper system [9]. In table I the main results of the sinusoidal shear tests in terms of the uivalent shear stiffness k, the uivalent damping coefficient σ and the uivalent damping ratio ξ, are summarized. TABLE I RESULTS OF THE SHEAR TESTS Fruency (f) Amplitude (A) BTU contact Equivalent shear stiffness (k ) (N m -1 ) Equivalent damping coefficient (σ ) (Hz) (m) (N s m -1 ) Equivalent damping ratio (ξ ) 0.1 0.02 No 1443 584 0.13 0.1 0.03 No 1841 505 0.09 0.1 0.03 Yes 1880 913 0.15 0.1 0.04 No 2416 519 0.06 0.5 0.02 No 1209 166 0.21 0.5 0.03 No 1563 142 0.14 0.5 0.03 Yes 1736 213 0.19 0.5 0.04 No 2323 152 0.10 1 0.02 No 1148 142 0.39 1 0.03 No 1416 142 0.31 1 0.03 Yes 1482 177 0.37 1 0.04 No 1884 138 0.23 The uivalent shear stiffness was obtained considering the following relation: k Fmax Fmin (1) d d max min (-) The results reported in table I, concerning the BTU without contact, clearly show the increasing of k with the increasing of the shear deformation amplitude A; moreover, k decreases with the increasing of the forcing fruency f. The uivalent damping coefficient σ decreases with the increasing of f. Another observation is that σ changes with respect to A, while in the case f=1 Hz, its value seems to be almost constant. The results also show that the parameter ξ increases with the increasing of f and decreases with the increase of A. In the case of BTU contact, it is possible to note only a slight variation of k, while the results clearly highlight the increasing of σ and ξ. The effect of the BTU contact on the isolator dissipated energy, represented by the hysteresis cycle, is more relevant for small fruency values. IV. SHAKE-TABLE TESTS OF A STRUCTURE WITH WRS-BTU ISOLATORS WRS-BTU isolators were adopted to insulate a laboratory cabinet (Fig. 13 and 14) constituted of a rigid steel frame (0.60x0.70x1.20m) on which may be fixed additional masses to modify the inertial properties. In Fig. 13 it is possible to note that the shaking table tests were performed with the BPI used as a shake-table. Fig. 13. Cabinet on the shake-table. The tests were conducted with the cabinet overall mass of 165kg. The additional masses were arranged in the lower part of the cabinet to avoid the cabinet overturning. where F max and F min are the maximum and minimum values of horizontal force, d max and d min are the horizontal displacement corresponding to F max and F min. The uivalent damping coefficient was determined by means of the uation σ 2ΔW, (2) 2 2 π f ( d d ) max min where ΔW is the area enclosed by one hysteresis cycle. The uivalent damping ratio is given by Fig. 14. Additional masses. The performance of the isolated cabinet was evaluated by means of the acceleration response of the isolated structure and its relationship with the ground acceleration.

, July 3-5, 2013, London, U.K. Harmonic type excitations with different intensities were used to investigate the dynamic characteristics of the isolated cabinet. Furthermore, an earthquake record was used to evaluate the seismic behaviour of the cabinet in the presence of a realistic seismic excitation [10]. A. Dynamic characteristics The tests were conducted for two different values of the amplitude (0.005 m and 0.010 m) and forcing fruency in the 0.5 5.0 Hz range. Using two accelerometers, the accelerations of the platform and of the cabinet were detected and the two time histories were compared. For each test, a fruency analysis of the two time histories (platform and cabinet accelerations) was performed and the amplitudes of the components, synchronous with that one, imposed to the platform, were compared; their ratio, reported as function of the forcing fruency (Fig. 15), shows that the cabinet acceleration is amplified in the neighbourhood of 1 Hz and that the system is isolated for forcing fruencies greater than about 1.5Hz; An approximation of the isolated cabinet natural fruency can be easily obtained considering an uivalent linear mass-spring-damper system; hence, the cabinet was modelled as a single degree of freedom system with four linear spring-damper devices. Since the shear tests have shown that it is not possible to find constant values of stiffness and damping for the considered system, the isolator uivalent shear stiffness adopted in the natural fruency calculation was chosen ual to the mean of the 12 values reported in table I. f n 1 4k 1 4 1695 1.02 Hz 2 m 2 3.14 165 (4) where m is the cabinet mass. The value obtained in (4) is in agreement with the experimental results reported in Fig. 15. Fig. 15. Acceleration ratio vs. forcing fruency. The dependence of the dynamic response of the isolated cabinet on the intensity of the ground motion highlights the nonlinear property of the WRS-BTU isolator. B. Earthquake responses Fig. 16 shows the cabinet and the platform acceleration for an earthquake ground excitation (Friuli 1976). In this case, the overall mass of the cabinet was chosen ual to 185 kg. The isolation system reduces the acceleration transmitted to the cabinet by 52 % over the ground acceleration. Fig. 16. Comparison between the ground and the cabinet acceleration. V. CONCLUSION An experimental investigation of the performances of a WRS-BTU seismic isolator was presented. The proposed isolator is cheap and easy to realize by coupling a BTU with WRS springs; both the components are of normal industrial production and are already characterized by the manufacturers. The tests on the WRS-BTU isolator were performed with a multi-purpose machine able to execute both shear tests on seismic isolators and shake-table tests on seismically isolated structures. The results concerning the shear tests showed a nonlinear behaviour of the device. Moreover, shake-table experiments, conducted on a laboratory cabinet uipped with four WRS-BTU isolators, demonstrated their nonlinear dynamic characteristic and, at the same time, highlighted their good seismic isolation performance in terms of ground acceleration reduction. REFERENCES [1] G. Di Massa, M. Migliaccio, S.Pagano, A seismic insulator based on wire rope spring and BTU, 2nd European Conference on Tribology (ECOTRIB2009), Pisa, Italy, June 7-10, 2009. [2] G. Di Massa, S. Pagano, E. Rocca, S. Strano, Characterization of a seismic WRS-BTU insulation system, XX AIMETA congress, ISBN: 9788890634017, Bologna, october 12-15, 2011. [3] R. Brancati, S. Strano, F. Timpone, An analytical model of dissipated viscous and hysteretic energy due to interaction forces in a pneumatic tire: Theory and experiments, Mechanical Systems and Signal Processing, vol. 25, no. 7, pp. 2785 2795, 2011. [4] M. Cardone, S. Strano, Fluid-Dynamic Analysis of Earthquake Shaking Table Hydraulic Circuit (ESDA2012-82422), in Proc. of the ASME 11th Biennial Conference on Engineering Systems Design and Analysis (ESDA2012), vol. 2, pp. 343 350, 2012. [5] G. Di Massa, S. Pagano, E. Rocca, S. Strano, Sensitive uipments on WRS-BTU isolators, Meccanica, DOI: 10.1007/s11012-013- 9708-9, 2013. [6] S. Pagano, R. Russo, S. Strano, M. Terzo, Modelling and Control of a Hydraulically Actuated Shaking Table Employed for Vibration Absorber Testing (ESDA2012-82118), in Proc. of the ASME 11th Biennial Conference on Engineering Systems Design and Analysis (ESDA2012), vol. 1, pp. 651 660, 2012. [7] S. Pagano, R. Russo, S. Strano, M. Terzo, Non-linear modelling and optimal control of a hydraulically actuated seismic isolator test rig, Mechanical Systems and Signal Processing, vol. 35, no. 1 2, pp. 255 278, 2013. [8] S. Pagano, M. Russo, S. Strano, and M. Terzo, A mixed approach for the control of a testing uipment employed for earthquake isolation systems, Proceedings of the Institution of Mechanical Engineers,

, July 3-5, 2013, London, U.K. Part C: Journal of Mechanical Engineering Science, DOI: 10.1177/0954406213484424, 2013. [9] C. Onorii, M. Spizzuoco, A. Calabrese, G. Serino, Applicability and reliability of innovative low-cost rubber isolators, XIV ANIDIS congress, Bari, September 18-22, Italy, 2011. [10] A. H. Muhr, G. Bergamo, Shaking Table Tests On Rolling-Ball Rubber-Layer Isolation System, in Proc. of the 14 th European Conference on Earthquake Engineering, vol. 7, pp. 5703-5710, Ohrid, Republic of Macedonia, 30 August -3 September, 2010.