FHWA Bridge Design Guidance No. 1 Revision Date: July 21, Load Rating Evaluation of Gusset Plates in Truss Bridges

Similar documents
Presented by: Civil Engineering Academy

Job No. Sheet 1 of 6 Rev B. Made by IR Date Oct Checked by FH/NB Date Oct Revised by MEB Date April 2006

Tension Members. ENCE 455 Design of Steel Structures. II. Tension Members. Introduction. Introduction (cont.)

Accordingly, the nominal section strength [resistance] for initiation of yielding is calculated by using Equation C-C3.1.

CHAPTER 2 LITERATURE REVIEW

Numerical Modeling and Analyses of Steel Bridge Gusset Plate Connections

CONNECTION DESIGN. Connections must be designed at the strength limit state

BLOCK SHEAR CONNECTION DESIGN CHECKS

UNIVERSITY OF AKRON Department of Civil Engineering

Timber and Steel Design. Lecture 11. Bolted Connections

twenty steel construction: columns & tension members ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS FALL 2013 lecture

db = 23.7 in B C D 96 k bf = 8.97 in tf = in k = 1.09 in 13 Fy = 50 ksi Fu = 65 ksi Member A-B, Interior column: A E

MODULE F: SIMPLE CONNECTIONS

[5] Stress and Strain

Where and are the factored end moments of the column and >.

Direct Design and Indirect Design of Concrete Pipe Part 2 Josh Beakley March 2011

Roadway Grade = m, amsl HWM = Roadway grade dictates elevation of superstructure and not minimum free board requirement.

SHEAR LAG IN SLOTTED-END HSS WELDED CONNECTIONS

(Round up to the nearest inch.)

Unfinished Bolt ordinary, common, rough or black bolts High strength Bolt friction type bolts

Application nr. 7 (Connections) Strength of bolted connections to EN (Eurocode 3, Part 1.8)

Abstract Block shear is a mode of failure in which a steel member fails in tension along one plane and shear on a

Fundamentals of Structural Design Part of Steel Structures

Appendix J. Example of Proposed Changes

BLOCK SHEAR BEHAVIOUR OF BOLTED GUSSET PLATES

Application nr. 3 (Ultimate Limit State) Resistance of member cross-section

Appendix K Design Examples

SHEAR CONNECTION: DESIGN OF W-SHAPE BEAM TO RECTANGULAR/SQUARE HSS COLUMN SHEAR PLATE CONNECTION

2010 NASCC / Structures Congress Orlando, Florida May 13, 2010

Design of Steel Structures Prof. Damodar Maity Department of Civil Engineering Indian Institute of Technology, Guwahati

It s a bird it s a plane it s Super Table! F y = 50 ksi F u = 65 ksi ASD LRFD ASD LRFD

CHAPTER 6: ULTIMATE LIMIT STATE

Failure in Flexure. Introduction to Steel Design, Tensile Steel Members Modes of Failure & Effective Areas

APOLLO SCAFFOLDING SERVICES LTD SPIGOT CONNECTION TO EUROCODES DESIGN CHECK CALCULATIONS

General Comparison between AISC LRFD and ASD

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

ENCE 455 Design of Steel Structures. III. Compression Members

SHEAR CONNECTION: W BEAM WITH SHEAR PLATE ONE-WAY SHEAR CONNECTION TO W COLUMN WEB

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

the Steel Construction Manual

Seismic Pushover Analysis Using AASHTO Guide Specifications for LRFD Seismic Bridge Design

Duan, L. and Reno, M. Performance-Based Seismic Design Criteria For Bridges Structural Engineering Handbook Ed. Chen Wai-Fah Boca Raton: CRC Press

Steel connections. Connection name : MEP_BCF_W=14.29[mm]_W=6.35[mm]_tp=63.5[mm]_N=0_N=2_N=0_N=1_W=14.29[mm]_W=14.29[mm]_W=14.29[ mm] Connection ID : 1

Example 1 - Single Headed Anchor in Tension Away from Edges BORRADOR. Calculations and Discussion

D e s i g n o f R i v e t e d J o i n t s, C o t t e r & K n u c k l e J o i n t s

Mechanics of Materials Primer

Design of Steel Structures Dr. Damodar Maity Department of Civil Engineering Indian Institute of Technology, Guwahati

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

Why are We Here? AASHTO LRFD Bridge Design Specifications Metal Pipe Section 12.7 Concrete Pipe Section Plastic Pipe Section 12.12

Project data Project name Project number Author Description Date 26/04/2017 Design code AISC dome anchor. Material.

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

Steel Post Load Analysis

An investigation of the block shear strength of coped beams with a welded. clip angles connection Part I: Experimental study

Curved Steel I-girder Bridge LFD Guide Specifications (with 2003 Edition) C. C. Fu, Ph.D., P.E. The BEST Center University of Maryland October 2003

Compression Members. ENCE 455 Design of Steel Structures. III. Compression Members. Introduction. Compression Members (cont.)

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

db = 23.7 in B C D 96 k bf = 8.97 in tf = in k = 1.09 in 13 Fy = 50 ksi Fu = 65 ksi Member A-B, Interior column: A E

7.3 Design of members subjected to combined forces

Design of Beams (Unit - 8)

BLOCK SHEAR BEHAVIOUR OF COPED STEEL BEAMS

Design of Shear Tab Connections for Gravity and Seismic Loads

APPENDIX D COMPARISON OF CURVED STEEL I-GIRDER BRIDGE DESIGN SPECIFICATIONS

Determine the resultant internal loadings acting on the cross section at C of the beam shown in Fig. 1 4a.

S E C T I O N 1 2 P R O D U C T S E L E C T I O N G U I D E - H E L I C A L S C R E W P I L E F O U N D A T I O N S

Lecture-03 Design of Reinforced Concrete Members for Flexure and Axial Loads

ε t increases from the compressioncontrolled Figure 9.15: Adjusted interaction diagram

Steel Design. Notation:

Structural Steelwork Eurocodes Development of A Trans-national Approach

DNV DESIGN. POU_Rect - Design Report Page 1 of 11

林保均 / Pao-Chun Lin. National Center for Research on Earthquake Engineering M.S. / Civil Engineering Department, National Taiwan University

Mechanics of Materials CIVL 3322 / MECH 3322

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: PNEUTEK, INC.

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

MODULE C: COMPRESSION MEMBERS

Appendix G Analytical Studies of Columns

Steel Cross Sections. Structural Steel Design

3.032 Problem Set 1 Fall 2007 Due: Start of Lecture,

Moment redistribution of continuous composite I-girders with high strength steel

The first NDS (1944) was based on allowable stress design (ASD). Copyright American Wood Council. All rights reserved.

Mechanics of Materials

Steel Design. Notation: a A A b A e

ERRATA for PE Civil Structural Practice Exam ISBN Copyright 2014 (July 2016 Second Printing) Errata posted

CHAPTER 3 THE EFFECTS OF FORCES ON MATERIALS

ME 243. Mechanics of Solids

SECTION 7 DESIGN OF COMPRESSION MEMBERS

Steel Design. Notation:

SAULTCOLLEGE of AppliedArtsand Technology SaultSte. Marie COURSEOUTLINE

CH. 5 TRUSSES BASIC PRINCIPLES TRUSS ANALYSIS. Typical depth-to-span ratios range from 1:10 to 1:20. First: determine loads in various members

Structural Steelwork Eurocodes Development of A Trans-national Approach

Chapter Two: Mechanical Properties of materials

CO~RSEOUTL..INE. revisedjune 1981 by G. Frech. of..a.pqij~t(..~ttsa.fidteconol.q.gy. Sault ",Ste'...:M~ri,e.: SAUl. ir.ft\,nl~t';~l' G ". E b:.

two structural analysis (statics & mechanics) APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2017 lecture STRUCTURAL ANALYSIS AND SYSTEMS

Materials Selection and Design Materials Selection - Practice

WRAP-AROUND GUSSET PLATES

Slenderness Effects for Concrete Columns in Sway Frame - Moment Magnification Method (CSA A )

FE-Analysis of Stringer-to-floor-beam Connections in Riveted Railway Bridges

Design of Reinforced Concrete Beam for Shear

RESILIENT INFRASTRUCTURE June 1 4, 2016

CHAPTER 5 Statically Determinate Plane Trusses

ALUMINUM STRUCTURAL PLATE HEADWALLS AASHTO LRFD BASIS OF DESIGN

Transcription:

FHWA Bridge Design Guidance No. 1 Revision Date: July 21, 2008 Load Rating Evaluation of Gusset Plates in Truss Bridges By Firas I. Sheikh Ibrahim, PhD, PE Part B Gusset Plate Resistance in Accordance with the Load Factor Rating Method (LFR) Gusset connections of non-load-path-redundant steel truss bridges shall be evaluated during a bridge load rating analysis. Non-load-path-redundant bridges are those with no alternate load paths and whose failure of a main component is expected to result in the collapse of the bridge. The evaluation of gusset connections shall include the evaluation of the connecting plates and fasteners. The capacity (referred to as the resistance in this Guidance) of a gusset connection is determined as the smaller resistance of the fasteners or gusset plates. The following guidance is intended to provide for life safety and thus the resistance of the connection is required to be checked at maximum loads only. The maximum loads are the loadings specified in AASHTO Article 10.47. Owners may require that connections be checked for other loading levels such as overload to minimize serviceability concerns. RESISTANCE OF FASTENERS: For concentrically loaded bolted and riveted gusset connections, the maximum axial load in each connected member may be assumed to be distributed equally to all fasteners. At maximum loads, the fasteners in bolted and riveted gusset connections shall be evaluated to prevent fastener shear and plate bearing failures. The provisions of AASHTO Article 10.56.1.3.2 shall apply for determining the resistance of fasteners to prevent fastener shear and plate bearing failures. For unknown rivet types, the shear resistance of one rivet shall be taken as: φ R = φfma r (1) where: F φ = shear strength of one rivet. The values in Table 1 may be used for φ F based on the year of construction:

Table 1 Year of Construction Constructed prior to 1936 or of unknown origin Constructed after 1936 but of unknown origin φ F ksi 18 21 m A r = the number of shear planes = cross-sectional area of the rivet before driving The shear resistance of a rivet in connections greater than 50.0 in. in length shall be taken as 0.80 times the value given in Eq. 1. RESISTANCE OF GUSSET PLATES: The resistance of a gusset plate shall be determined as the least resistance of the plate in shear, tension including block shear, compression, and combined flexural and axial loads. GUSSET PLATES IN TENSION Gusset plates subjected to axial tension shall be investigated for two conditions: Yield on the effective gross section, and Block shear rupture The resistance for gusset plates in tension, R r, shall be taken as the least of the values given by either yielding on the effective area or the block shear rupture resistance. Effective Gross Section Yielding R = A F (2) r e y where: A e = effective gross cross-sectional area taking into account the possibility of net section fracture. Ae = An + β Ag Ag (3) A n = net cross-sectional area of the plates as specified in AASHTO Article 10.16.14. β = 0.0 for M 270 Grade 100/100W steels, or when holes exceed 1¼ inch in diameter. = 0.15 for all other steels and when holes are less than or equal to 1¼ inch in diameter. = gross cross-sectional area of the plates. A g

F y = minimum yield strength of the plates, as specified in AASHTO Table 10.2A. For the determination of the gross and net section areas, the effective gross width of the gusset plate in tension maybe determined by the Whitmore method. In this method, the effective width is measured across the last row of fasteners in the connection under consideration. The effective width is bound on either side by the closer of the nearest adjacent plate edges or lines constructed starting from the external fasteners within the first row and extending from these fasteners at an angle of 30 degrees with respect to the line of action of the axial force. Figures 1 and 2 provide examples for determining the effective width in tension in accordance with the Whitmore method. Figure 1 Example 1 for using the Whitmore method to determine the effective width in tension

Figure 2 Example 2 for using the Whitmore method to determine the effective width in tension When using the Whitmore method, proximity of the connected members can affect the resistance of gusset plates in tension. Therefore, special attention must be exercised in congested areas to evaluate all possible failure modes of gusset connections. Block Shear Rupture Resistance The resistance to block shear rupture is that resulting from the combined resistance of parallel and perpendicular planes; one in axial tension and the others in shear. The resistance of the plate for block shear rupture shall be taken as: If A, then n 0. 58Avn R r =.85( 0. 58Fy Avg + Fu Atn ) Otherwise: R =.85( 0. 58F A + F A ) Where: r 0 (4) 0 (5) 0.85 = resistance factor for block shear. This ratio is calculated as the LRFD resistance factor for net section tension fracture (0.8) divided by the resistance factor for gross section tension yielding (0.95) A vg = gross area along the plane resisting shear stress A tg = gross area along the plane resisting tension stress = net area along the plane resisting shear stress A vn u vn y tg

A tn = net area along the plane resisting tension stress F y = minimum yield strength of the plate, as specified in AASHTO Table 10.2A F u = minimum tensile strength of the plate, as specified in AASHTO Table 10.2A The analysis of block shear rupture involves the evaluation of several patterns of planes to arrive at the governing pattern. Figure 3 provides some examples of potential block shear rupture planes for gusset plates in tension. Figure 3 Examples of potential block shear rupture planes for gusset plates in tension GUSSET PLATES SUBJECT TO SHEAR The shear resistance, R r, for gusset plates subject to shear shall be taken as the lesser of the shear yield and the shear fracture resistance specified in Equations 6 and 7, respectively: where: Rr = 0. 58Fy Ag Ω (6) R = 0.85 0. 58F A (7) r u n 0.85 = resistance factor for shear fracture on the net section. This ratio is calculated as the LRFD resistance factor for net section tension fracture (0.8) divided by the resistance factor for gross section tension yielding (0.95) A g = gross area of the plates resisting shear A n = net area of the plates resisting shear F y = minimum yield strength of the plates F u = minimum tensile strength of the plates Ω = reduction factor taken as:

Ω = 1.00 for the case of uniform shear stress distribution where the gusset plates are of ample stiffness to prevent buckling and develop the plastic shear force of the plates, or Ω = 0.74 for the case of flexural shear stress distribution, and in the absence of a more rigorous analysis or criterion to assure and quantify the stiffness requirements to develop the plastic shear force of the plates. The analysis of gusset plates for shear involves the evaluation of several shear sections to arrive at the governing section. Figures 4 and 5 provide examples of shear sections to be evaluated in gusset plates in gross section shear yielding and net section shear fracture. Figure 4 Examples of gross section shear yielding planes

GUSSET PLATES IN COMPRESSION The proximity of connected members, complex state of stress, and boundary conditions can influence the resistance of gusset plates in compression. Therefore, special care must be exercised to properly assess the buckled shape and compressive resistance of gusset plates in compression. In the absence of a more rigorous analysis, the resistance of gusset plates in compression may be determined as that of idealized members in compression, in accordance with the provisions of AASHTO Article 10.54.1.1. The unbraced length, L c, may be determined as the distance between the last row of fasteners in the compression member under consideration and the first row of fasteners in the closest adjacent member measured along the line of action of the compressive axial force. When lateral sway of gusset plates is possible, the effective length factor, K, for gusset plates may be taken from Table 2 for Cases (d), (e), or (f), depending on the anticipated buckled shape. When lateral sway of gusset plates is not possible, the effective length factor, K, for gusset plates may be taken from Table 2 for Cases (a), (b), or (c), as appropriate. The effective width of the idealized compression member may be determined in accordance with the Whitmore method. Figure 6 provides an example showing the unbraced length and effective width for a gusset plate in compression. Table 2 K Values (a) (b) (c) (d) (e) (f) Buckled shape Theoretical K value 0.5 0.7 1.0 1.0 2.0 2.0 Design K value 0.65 0.80 1.0 1.2 2.1 2.0

GUSSET PLATES UNDER COMBINED FLEXURAL AND AXIAL LOADS The resistance for gusset plates subject to combined flexural and axial stresses on the gross area of the plate may be taken as F y. where: F y = minimum yield strength of the plate. Gusset plates behave as deep members and; therefore, the application of flexural theory to gusset plates may not be applicable. Therefore, the combined flexural and axial stress at the extreme fiber is simplified and limited to F y. The analysis of gusset plates for combined flexural and axial loads involves the evaluation of several sections to arrive at the critical section. Figure 7 provides examples of sections to be evaluated in gusset plates under combined flexure and axial loads. Note that the sections in Figure 7 are placed such that the applied eccentricity is maximized.