Investigation of Ce-doped Gd2Si2O7 as a scintillator. Author(s) Kurashige, Kazuhisa; Ishibashi, Hiroyuki; Furusaka, Instructions for use

Similar documents
New Scintillators for the Border Monitoring Equipment

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Design of a Lanthanum Bromide Detector for TOF PET

PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB

SCINTILLATION DETECTORS AND PM TUBES

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

D ue to considerable losses by absorption and reflections, short-wavelength light transmission over long

arxiv: v1 [physics.ins-det] 29 Jun 2011

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

A Study on Radiation Damage in PWO-II Crystals

INORGANIC crystal scintillators are widely used in high

Characterization of the new scintillator Cs 2 LiYCl 6 :Ce 3+ *

DETECTORS. I. Charged Particle Detectors

In our recent paper [1], applicability of the self-activation of an NaI scintillator has been studied for the photo-neutron monitoring around

Improved scintillation proportionality and energy resolution of LaBr 3 :Ce at 80K

BSO Crystals for the HHCAL Detector Concept

M.J. CIESLAK, K.A.A. GAMAGE Department of Engineering, Lancaster University Lancaster, LA1 4YW United Kingdom ABSTRACT

arxiv:physics/ v1 3 Aug 2006

arxiv: v2 [physics.ins-det] 8 Feb 2013

Precision neutron flux measurement with a neutron beam monitor

Characterization of the Lanthanum Chloride Scintillation Detector

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

IN the last decade, cerium doped silicate based heavy

DESIGN OF NEUTRON DOSE RATE METER FOR RADIATION PROTECTION IN THE EQUIVALENT DOSE

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

Quality Assurance. Purity control. Polycrystalline Ingots

Radiation Detection and Measurement

Fast scintillation detectors for high-energy X-ray region

Nuclear Instruments and Methods in Physics Research A

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

Radiation Detection and Measurement

Behavior and Energy States of Photogenerated Charge Carriers

SILVER NEUTRON ACTIVATION DETECTOR FOR MEASURING BURSTS OF 14 MEV NEUTRONS

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Alpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal

BaF 2 :Ce POLYMER COMPOSITE GAMMA-RAY SCINTILLATORS M.B. Barta, J.H. Nadler, Z. Kang, B.K. Wagner

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

2.5 Physics of the Universe, Astrophysics, Nuclear Planetology Dark Matter and Double Beta Decay Study Planetary Nuclear

Supporting Information

Cracking of GSO Single Crystal Induced by Thermal Stress

Large Size LYSO Crystals for Future High Energy Physics Experiments

Excitation-Wavelength Dependent and Time-Resolved Photoluminescence Studies of Europium Doped GaN Grown by Interrupted Growth Epitaxy (IGE)

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Light yield non-proportionality and energy resolution of Lu 1.95 Y 0.05 SiO 5 :Ce and Lu 2 SiO 5 :Ce scintillation crystals

Scintillation Detector

Judd-Ofelt intensity parameters

Site selectively excited luminescence and energy transfer of X 1 -Y 2 SiO 5 :Eu at nanometric scale

Louis Baum University of Michigan, REU Student Summer UM Nuclear Sciences Group

Search for Nuclear Reaction Products in Gas Phase Experiments - Deuterium Permeation and Absorption -

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

Boron-based semiconductor solids as thermal neutron detectors

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

PERFORMANCE IMPROVEMENT OF CZT DETECTORS BY LINE ELECTRODE GEOMETRY

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Mass of the electron m 0

Athens Ag. Spyridonos, Aigaleo, Athens, Greece. Corresponding author:

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

Radiation measurements with heat-proof polyethylene terephthalate bottles

05 - Scintillation detectors

Survey of the performance of scintillation materials at low temperatures

The trap states in the Sr 2 MgSi 2 O 7 and (Sr,Ca)MgSi 2 O 7 long afterglow phosphor activated by Eu 2+ and Dy 3+

A new timing model for calculating the intrinsic timing resolution of a scintillator detector

Measurement of high energy gamma rays with large volume LaBr 3 :Ce scintillators

Title. Author(s)Chiba, Go; Tsuji, Masashi; Narabayashi, Tadashi. CitationAnnals of nuclear energy, 65: Issue Date Doc URL.

The fast light of CsI(Na) crystals

MC simulation of a PGNAA system for on-line cement analysis

SCINTILLATORS AND WAVELENGTH SHIFTERS FOR THE DETECTION OF IONIZING RADIATION *

Neutron Detection. n interactions with matter n detection High/low energy n detectors

Crystals for the HHCAL Detector Concept Rihua Mao, Member, IEEE, Liyuan Zhang, Member, IEEE, and Ren-Yuan Zhu, Senior Member, IEEE

Scintillation Detectors

APEX CARE INSTITUTE FOR PG - TRB, SLET AND NET IN PHYSICS

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

OPPORTUNITY TO JOIN IEEE AND NPSS

Joint ICTP-IAEA Workshop on Physics of Radiation Effect and its Simulation for Non-Metallic Condensed Matter.

Title Sn^2+ center in the SnO-ZnO-P_2O_5. Author(s) Matsumoto, Syuji; Tokuda, Yomei; Yo. Citation Optics Express (2012), 20(25): 2731

Light yield non-proportionality and intrinsic energy resolution of doped CsI scintillators

Readout of LYSO using a new silicon photodetector for positron emission tomography

An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

Neutron and Gamma-ray Emission Double Dierential Cross Sections. *5 Energy Conversion Engineering, Kyushu University, Kasuga-koen, Kasuga-shi 816.

Recent advances and future perspectives of gamma imagers for scintimammography

Chapter 4 Scintillation Detectors

ISMA R&D scintillation detectors for high energy physics projects and medical application

Feasibility of a new polarized active detector for low-energy ν

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Microwave-assisted polyol synthesis of copper nanocrystals without additional protective agents

Advantages / Disadvantages of semiconductor detectors

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

Characterizing, Simulating, and Eliminating Vibration Induced Counts in Measurement While Drilling Gamma Ray Detectors. authors

W. Udo Schröder Departments of Chemistry & of Physics and Astronomy

Supplementary Information for

Supplementary Information. Formation of porous SnS nanoplate networks from solution and their application in hybrid solar cells

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

Study of Isospin simmetry using the PARIS detector. Alice Mentana

Development of New MicroStrip Gas Chambers for X-ray Applications

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

Transcription:

Title Investigation of Ce-doped Gd2Si2O7 as a scintillator Kawamura, Sohan; Kaneko, Junichi H.; Higuchi, Mikio; Author(s) Kurashige, Kazuhisa; Ishibashi, Hiroyuki; Furusaka, Nuclear Instruments and Methods in Physics Research CitationEquipment, 583(2-3): 356-359 Issue Date 2007-12-21 Doc URL http://hdl.handle.net/2115/32338 Type article (author version) File Information A-AC583(2-3).pdf Instructions for use Hokkaido University Collection of Scholarly and Aca

Investigation of Ce-doped Gd 2 Si 2 O 7 as a scintillator material Sohan Kawamura 1, Junichi H Kaneko 1, Mikio Higuchi 1, Fumiyuki Fujita 1, Akira Homma 1, Jun Haruna 1, Shohei Saeki 1, Kazuhisa Kurashige 2, Hiroyuki Ishibashi 2, Michihiro Furusaka 1 1 Hokkaido University, N13W8, Kita-ku, Sapporo 060-8628, Japan, 2 Hitachi Chemical, 1380-1, Tarazaki, Hitachinaka-shi, 305-0047, Japan *Corresponding Author: k-souhan@eng.hokudai.ac.jp Abstract As a novel scintillation material, the use of Ce-doped Gd 2 Si 2 O 7 was investigated. In fact, (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 powder showed about five-times greater light output than Gd 2 SiO 5 (GSO) powder samples for alpha-particles from 241 Am. Furthermore, a fast decay constant of 59 ns was obtained for alpha-particles from 241 Am. Relations between the Ce-concentration, crystal structure and luminescence characteristics were also elucidated. Results of these studies show that heavy Ce-doping alters the Gd 2 Si 2 O 7 crystal structure and that the luminescence intensity is dependent not on Ce-concentration but on the triclinic structure formed by heavy Ce-doping. Keywords- gadolinium compounds, Gd 2 Si 2 O 7, neutron detectors, radiation detectors, scintillators 1. Introduction Rare earth silicon oxide scintillators such as Gd 2 SiO 5 (GSO) and Lu 2 SiO 5 (LSO) are widely used for 1

radiological diagnosis because of their higher density, high light output, and fast decay constant [1 5]. Neutron scattering experiments for material sciences also require high-performance scintillators because higher intensity neutron sources such as J-PARC are under construction. For that reason, GSO is anticipated as a neutron scintillator because of the large neutron capture cross-section of Gd, greater light output [6], and good radiation-damage resistance [7]. However, Uozumi et al. reported higher sensitivity of GSO for detection of background gamma-rays in neutron scattering experiments [8]. Consequently, Reeder used thin GSO for neutron detection [9], and Konishi et al. used plastic as a moderator to reduce gamma-ray sensitivity [10]. Tokanai et al. also applied thin GSO single crystals to a position-sensitive detector for cold neutrons and described that position resolution would be improved using thinner GSO [11]. Another candidate of Gd-based scintillators is Gd 2 O 2 S (GOS), which is used in X-ray detection [12 14]. Although GOS has greater light output, its decay time of 4 μs is too long for application for neutron detection, which requires at least 1 10 6 cps count rate [15]. For those reasons, although we attempted fabrication of GSO film using evaporation or polishing aimed at decreasing gamma-ray sensitivity and improving the position resolution, the fragility of GSO [16] and its melting temperature of 1950 C prevented fabrication of GSO films. Nevertheless, in the process described above, we found that Ce-doped Gd 2 Si 2 O 7 has a lower melting point < 1850 C than GSO and high luminescence intensity [17]. This paper presents results of a study of the relations between Ce-concentration, crystal structure, and luminescence characteristics; 2

we report a comparison of light-output measurements of Ce-doped Gd 2 Si 2 O 7, GSO single-crystals and GSO powder samples using a 241 Am alpha-particle source. 2. Experimental 2-1. Sample preparation These experiments used a (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 powder sample and Gd 2 SiO 5 (GSO) single-crystals purchased from Hitachi Chemical Co. Ltd. and (Gd 1-x Ce x ) 2 Si 2 O 7 (x=0 0.1) powders fabricated by solid state reaction. Then, Gd 2 O 3, SiO 2, and CeO 2 powders whose respective purities were 5N, 5N, and 4N were mixed at a composition of (Gd 1-x Ce x ) 2 Si 2 O 7 (x=0 0.1). The mixed powders were sintered at 1500 C for 8 h in an alumina crucible using an electric furnace in an air atmosphere. The sintered powders were crushed using an agate mortar and passed through sieves. The size of each particle was estimated as 50-100um. X-ray diffraction patterns were measured using Cu-Ka X-ray imaging. The X-ray patterns were compared with Joint Committee on Powder Diffraction Standards (JCPDS) data to determine the crystal structure; each crystal structure concentration was evaluated using Crystal Studio version 8.0 (Crystal Systems Co., Ltd.). 2-2. Luminescence spectra and alpha-particles spectra measurement 3

Photoluminescence spectra of each composition sample were measured under 240-nm wavelength light irradiation using a spectrometer (FP6500; Jasco Inc.). Samples of 100 mg were weighed out and coupled to a glass plate using optical grease. The pulse-height spectrum and decay curves of (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 were also measured to compare the light output of (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 with other scintillators using a 241 Am alpha-particle source. The light output was compared by evaluating the MCA channel of the total energy peak. In this experiment, GSO single crystals and GSO powder sample which was obtained by crushing GSO single crystals were used as references. Figure 1 shows that (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 and GSO powder sample were coupled to a glass plate and set. Ce-concentration of the GSO single-crystals was... GSO single crystals were coupled to photomultiplier by optical grease. The H7195 photomultiplier tube (Hamamatsu Photonics KK), Ortec 113 pre-amplifier, and Ortec 672 spectroscopy amplifier were used for spectroscopy. A digital oscilloscope (LT584; Iwatsu Co.) was used at 1 GHz frequency range and 2 GS/s sampling for decay-curve measurements. 3. Results and discussion 3-1. Crystal structure of the samples Figure 2 shows XRD patterns of (Gd 1-x Ce x ) 2 Si 2 O 7 powder samples with various compositions. Results showed that XRD patterns varied with increased Ce concentration. The crystal structure determined 4

by JSPDS and the relative abundance of each crystal structure are shown in Table 1, which shows that triclinic structure abundance increased with Ce concentration. According to Felsche s study of rare earth disilicate, Gd 2 Si 2 O 7 forms an orthorhombic structure and space group Pna2 1 or Pnam [18]. It is considered that heavy Ce-doping changed the GPS lattice parameter; subsequently, the triclinic structure was formed. 3-2. Luminescence spectrum of (Gd 1-x Ce x ) 2 Si 2 O 7 (x=0 0.1) Fig3 shows the comparison of photo luminescence spectra of (Gd 1-x Ce x ) 2 Si 2 O 7 (x=0 0.1) samples under 240nm wavelength light irradiation. Increase of luminescence intensity with Ce-concentration was observed. The relation between luminescence intensity and abundance of triclinic structure are plotted in Fig4. Of course the luminescence intensity varies from crystal orientation or surface condition etc, however, remarkable increment of luminescence intensity was obtained in large triclinic structure abundance part. It is considered that (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 with triclinic structure contribute to luminescence. The peak wavelength 374nm and 397nm of (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 are due to 5d - 4f transition in Ce 3+ ion of (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7. 3-2. α-particle measurements The (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 powder with the most abundant triclinic structure was used in pulse height 5

spectrum measurements using a 241 Am alpha-particle source. To compare the light output of (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7, a GSO powder sample was also used in measurements. The total energy peak channel in Fig. 5 indicated that (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 had five-times greater light output than GSO. However, two peaks exist in the spectrum of (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7. A typical decay curve of (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 was plotted in Fig. 6. The decay constant obtained from exponential function fitting was 52 ns and... This decay constant is 1/67 of the decay time of GOS, so higher counting rate is expected than GOS. 4. Conclusion As the first step toward novel scintillator development, the relations between Ce-concentration of Gd 2 Si 2 O 7, crystal structure, and luminescence characteristics were examined in this study. Results showed variation of the crystal structure by Ce-doping and a relation between the abundance of triclinic structure and luminescence intensity. According to Felsche, a triclinic structure is not formed in Gd 2 Si 2 O 7 [18], but we considered that heavy Ce-doping changed the lattice parameter of Gd 2 Si 2 O 7 and that the triclinic structure was formed. Pulse-height spectrum measurements using an 241 Am alpha-particle source showed that (Gd 0.9 Ce 0.1 ) 2 Si 2 O 7 has five-times greater light output than GSO and a fast decay time of 59 ns. These results support the possibility of the use of Ce-dopedGd 2 Si 2 O 7 as a scintillation material. 6

References [1] Carel W E van Eijk, Phys. Med. Biol. 47 (2002) R85 R106 [2]L. Pidol et al., J. Phys. Condens. Matter 15 (2003) 2091 2102 [3] A. Lempicki, Nuclear Instruments and Methods in Physics Research A 416 (1998) 333 344 [4] S Yamamoto et al., Phys. Med. Biol. 51 (2006) 457 469 [5] R Boellaard et al., Phys. Med. Biol. 48 (2003) 429 448 [6] H. Ishibashi et al., IEEE Trans. Nucl. Sci. NS45 (3) (1998) 518 [7] M. Kobayashi et al., Nucl. Instr. and Meth. A 330 (1993) 115 [8] Y. Uozumi, K. Anami, A. Nohtomi, T. Saeki, M. Matoba, J. Nucl. Sci. Tech. 34 (1997) 80 [9] P.L. Reeder, Nucl. Instr. and Meth. A 353 (1994) 134 136 [10] D. Konishi, Y. Uozumi, H. Yoshida, M. Matoba, Nucl. Instr and Meth. A 420 (1999) 467 472 [11] F. Tokanai et al., Nuclear Instruments and Methods in Physics Research A 452 (2000) 266 272A [12] G. Glendinning, et al., Phys. Med. Biol. 46 (2001) 517 530 [13] J. Zhang, Journal of Luminescence 117 (2006) 141 146 [14] C. Greskovich, Annu. Rev. Mater. Sci. 27 (1997) 69 88 [15] N. Martin, Meas. Sci. Technol. 17 (2006) R37 R54 [16] K. Kurashige et al., Jpn. J. Appl. Phys. 36 (1997) 2242 7

[17] J.H. Kaneko et al., Nucl. Instrum. Meth. A529 (2004) 307 309 [18] J. Felsche. J. Less-Common Metals, 21 (1970) 1 14 Figure caption Table 1 Abundance of triclinic structure in (Gd1-xCex)2Si2O7 Fig.1 Experimental set-up of alpha-particle spectra measurement. Fig.2 XRD patterns obtained for (Gd1-xCex)2Si2O7. Fig.3 Photoluminescence spectra of (Gd1-xCex)2Si2O7 under 250 nm irradiation Fig.4 Relation between triclinic abundance and luminescence intensity. Fig.5 Comparison of light outputs (Gd0.9Ce0.1)2Si2O7 with GSO. Pulse height spectra were measured using a 241 Am alpha-particle source. Fig.6 Typical decay curve of (Gd0.9Ce0.1)2Si2O7 for alpha particles. 8

Table 1. Abundance of triclinic structure in (Gd1-xCex)2Si2O7 Composition Abundance of triclinic structure (%) Other crystal structure (%) Gd2Si2O7 0 100 (Gd0.99Ce0.01)2Si2O7 0 100 (Gd0.95Ce0.05)2Si2O7 17 83 (Gd0.90Ce0.10)2Si2O7 35 65 86 14 (Gd0.90Ce0.10)2Si2O7 96 4 (Hitachi Chemical Co. Ltd.)

Figure caption Fig. 1 Experimental set-up of alpha-particle spectra measurement. Fig. 2. XRD patterns obtained for (Gd1-xCex)2Si2O7. Fig. 3 Photoluminescence spectra of (Gd1-xCex)2Si2O7 under 250 nm irradiation Fig.4 Relation between triclinic abundance and luminescence intensity. Fig. 5 Comparison of light outputs (Gd0.9Ce0.1)2Si2O7 with GSO. Pulse height spectra were measured using a 241 Am alpha-particle source. Fig.6. Typical decay curve of (Gd0.9Ce0.1)2Si2O7 for alpha particles. Fig1 1

Fig. 2.. Fig. 3 2

Fig.4 Fig. 5 3

Fig.6. 4