Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

Similar documents
A monolithic array of silicon drift detectors coupled to a single scintillator for γ-ray imaging with sub-millimeter position resolution

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

1842 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER M. Marisaldi, C. Labanti, H. Soltau, C. Fiorini, A. Longoni, and F.

Silicon Drift Detectors for gamma-ray detection: 15 years of research (and collaboration between Politecnico and INAF-Milano)

SILICON DRIFT DETECTORS FOR HIGH RESOLUTION, HIGH COUNT RATE X-RAY SPECTROSCOPY AT ROOM TEMPERATURE

Amonolithic X/gamma-ray detector with an energy range

Semiconductor Drift Detectors: Applications and New Devices

Nuclear Instruments and Methods in Physics Research A

Analysis of Background Events in Silicon Drift Detectors

Outline. Introduction, motivation Readout electronics, Peltier cooling Input J-FETsJ

Key words: avalanche photodiode, soft X-ray detector, scintillation γ-ray detector, imaging device PACS: 07.85;95.55.A;85.60.D

VORTEX A NEW HIGH PERFORMANCE SILICON DRIFT DETECTOR FOR XRD AND XRF APPLICATIONS

Development of High-Z Semiconductor Detectors and Their Applications to X-ray/gamma-ray Astronomy

Silicon Drift Detectors: Understanding the Advantages for EDS Microanalysis. Patrick Camus, PhD Applications Scientist March 18, 2010

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

Semiconductor X-Ray Detectors. Tobias Eggert Ketek GmbH

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

THE spectroscopic performance of large volume CdZnTe

arxiv: v2 [physics.ins-det] 8 Feb 2013

The GERDA Phase II detector assembly

The Mini-Calorimeter detector for the AGILE mission

Development of New MicroStrip Gas Chambers for X-ray Applications

Controlled Si-Drift Detectors

Readout of LYSO using a new silicon photodetector for positron emission tomography

The Mini-Calorimeter for the AGILE satellite

Nuclear Instruments and Methods in Physics Research A

Pulse-shape shape analysis with a Broad-energy. Ge-detector. Marik Schönert. MPI für f r Kernphysik Heidelberg

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

arxiv:physics/ v1 [physics.ins-det] 14 Feb 2005

Measurements of CsI(Tl) Crystals with PMT and APD. ipno.in2p3.fr Jean Peyré Milano - October 2006

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Advances in the Micro-Hole & Strip Plate gaseous detector

On the development of compound semi-conductor thallium bromide detectors for astrophysics

Performance of the Gamma-ray Imaging Detector with Micro-TPC

Laboratory of Radiation Detectors and

Optimization of a Silicon Drift Detector Module for a Gamma Camera

New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Recent Advances of Planar Silicon APD Technology

Measurement of high energy gamma rays with large volume LaBr 3 :Ce scintillators

Silicon Detectors. Particle Physics

Development of a new MeV gamma-ray camera

Silicon Controlled Drift Detectors for Imaging Applications

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

First Results and Realization Status of a Proton Computed Radiography Device

arxiv: v1 [physics.ins-det] 24 Jan 2018

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

arxiv:physics/ v1 3 Aug 2006

Large Area Avalanche Photodiodes in X-rays and scintillation detection

Ground Calibration of X-ray CCD Detectors with Charge Injection for the X-ray Imaging Spectrometer on Astro-E2

Characterization and Monte Carlo simulations for a CLYC detector

Review of Semiconductor Drift Detectors

Design of a Lanthanum Bromide Detector for TOF PET

M. De Napoli, F. Giacoppo, G. Raciti, E. Rapisarda, C. Sfienti. Laboratori Nazionali del Sud (LNS) INFN University of Catania. IPRD Oct.

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

FARCOS Femtoscope Array for Correlations & Spectroscopy

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

arxiv: v1 [physics.ins-det] 12 Jan 2016

Radiation Effects nm Si 3 N 4

High-efficiency and fast-timing scintillators

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Factors Affecting Detector Performance Goals and Alternative Photo-detectors

Investigation of fast neutron spectroscopy capability of 7 Li and 6. Li enriched CLYC scintillator for nuclear physics experiments

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

JRA3: Technology development for high-time-resolution astronomy

Pixels GaAs Detectors for Digital Radiography. M.E. Fantacci. and. Abstract

Design and production of Scintillation Detectors

Development of semiconductor imaging detectors for a Si/CdTe Compton camera

1 of :32

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

arxiv: v1 [physics.ins-det] 29 Jun 2011

Charge collection in PET detectors

CADMIUM telluride (CdTe) and cadmium zinc telluride

Results of a Si/CdTe Compton Telescope

InAs avalanche photodiodes as X-ray detectors

GAMMA RAY SPECTROSCOPY

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

The path to Germanium Drift Detectors

Pulse Height Analysis System (PHA) designed for W7-X Presented by Monika KUBKOWSKA

AGILE, a satellite for high energy Gamma Ray Astrophysics: Prospects for the MiniCalorimeter

NEW X-RAY DETECTORS FOR XRF ANALYSIS. Jan S. Iwanczyk & Bradley E. Patt Photon Imaging, Inc., Northridge, CA 91324

High Purity Germanium Detector Calibration at ISOLDE

Chapter 4 Scintillation Detectors

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

1 Introduction Although Ge detectors have been used to detect fl radiation for more than 3 years, new capabilities are still being developed. Constant

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

PERFORMANCE IMPROVEMENT OF CZT DETECTORS BY LINE ELECTRODE GEOMETRY

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

SDDs for Science Applications

GEM: A new concept for electron amplification in gas detectors

ORTEC. SLP Series Silicon Lithium-Drifted Planar Low-Energy X Ray Detector Product Configuration Guide

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

arxiv: v1 [physics.ins-det] 17 May 2017

Position Sensitive Germanium Detectors for the Advanced Compton Telescope

Transcription:

1 Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors C. Fiorini, A. Longoni, F. Perotti, C. Labanti, E. Rossi, P. Lechner, and L. Strüder Abstract-- Silicon Drift Detectors (SDDs) coupled to scintillators have been recently employed successfully in gammaray detection. The low value of output capacitance of a SDD allows to reach a lower electronics noise with respect to a conventional silicon photodiode. Detectors based on array of SDDs are of particular interest for gamma-ray imaging. A first prototype conceived for high-resolution imaging is based on a monolithic array of small SDDs (5 mm 2 each unit) with on-chip JFET. The first results obtained with a seven-elements array are here reported. For the realization of gamma detectors of larger active areas based on assembled units, SDDs of 3 mm 2 of area with external JFET have been produced. We present the experimental results obtained in the characterization of a single CsI(Tl)-SDD unit. R I. INTRODUCTION ecent research has shown that gamma detectors based on CsI(Tl) scintillators coupled to Photodiodes (PDs) arrays offers several advantages with respect to the conventional PMT-based detectors. In fact, the availability of arrays of small PDs can allow the improvement of the spatial resolution for γ-ray imaging while the compactness of a scintillator-pds assembly permits to reduce the size of the detector. Gamma detectors based on arrays of single CsI(Tl)- PD units have been already developed for Nuclear Medicine and for astrophysics experiments [1-3]. Superior performances in scintillation detection with respect to conventional PDs can be obtained by using a Silicon Drift Detector (SDD) [4]. This detector is in fact characterized by a very low value of output capacitance (about.1 pf) which is independent from the active area of Manuscript received November 5, 2. This work was supported in part by Italian ASI and INFN. C. Fiorini is with Politecnico di Milano, Dipartimento di Ingegneria Nucleare, CESNEF, Via Ponzio 34/3, 2133 Milano, Italy (telephone: +39-2-23996147, e-mail: carlo.fiorini@polimi.it). A. Longoni is with Politecnico di Milano, Dipartimento di Elettronica e Informazione, Piazza L. da Vinci 32, 2133 Milano, Italy. F. Perotti is with Istituto di Fisica Cosmica G. Occhialini, C.N.R., via Bassini 15, 2133 Milano, Italy. C. Labanti and E. Rossi are with Istituto di Tecnologie e Studio delle Radiazioni Extraterrestri, C.N.R., via Gobetti 11, 4129 Bologna, Italy. P. Lechner is with KETEK GmbH, Am Isarbach 3, D-85764 Oberschleissheim, Germany. L. Strüder is with MPI für Extraterrestrische Physik Halbleiterlabor, Otto- Hahn-Ring 6, D-81739 München, Germany. the device. If compared with a PD of equivalent area and thickness, the SDD then offers a lower value of electronics noise. An energy resolution of 7.49 % and 4.34 % FWHM at 122 kev and 662 kev, respectively, and an energy threshold of 1 kev have been measured at room temperature (2 C) with a single SDD (7 mm 2 of active area) coupled to a CsI(Tl) scintillator 5 mm thick [5]. With a first prototype of γ-ray detector for 1-D position measurements, based on a single CsI(Tl) crystal coupled to a linear array of single SDDs (5 mm 2 area for each unit), a position resolution better than.5 mm FWHM has been achieved [6]. On the basis of the preliminary results achieved with small SDD units, monolithic arrays of SDDs seems to be a promising solution for the realization of small gamma imaging detectors (sensitive area up to few cm 2 ), based on the Anger Camera scheme, with sub-millimeter position resolution. For this purpose, monolithic arrays of small SDDs have been recently realized. Preliminary results with this kind of detector have been obtained with a prototype based on an array of seven hexagonal SDDs of 5 mm 2 of active area each, arranged in a honeycomb configuration. Each SDD has a JFET integrated directly on the detector chip. This solution is particularly suitable in the case of monolithic arrays of several units because avoids the mounting and connection of a high number of external front-end transistors. A first evaluation of the imaging capability of this prototype is here presented. When the active area required for the gamma detector should exceed several cm 2, a solution based on monolithic arrays of small units becomes no more practical because of the high number of readout channels. In this case, the performances of gamma detectors based on relatively large SDD units should be evaluated. The contribution to the electronics noise which depends on the SDD capacitance does not change with the active area and the increase of leakage current with the area could be minimized either by an optimization of the fabrication process either by cooling the detector. In view of the realization of gamma-detectors of larger areas, single SDD units, each one of an active area of 3 mm 2 have been realized. In the case of a SDD of large area, where the leakage current is the main factor limiting the performance near room temperature, the use of an external

2 JFET mounted close to the detector anode has been preferred. In fact, this solution reduces the number of processing steps for the detector production, by avoiding the JFET integration, with the benefit of a lower leakage current. The results of the experimental characterization of a single detector unit are presented in this work. II. MONOLITHIC ARRAY OF SDDS WITH ON-CHIP JFET A. Methods A first prototype of γ-ray detector for 2-D position measurements has been realized by coupling a single CsI(Tl) scintillator (1.4 mm thick) to an array of seven hexagonal SDDs, arranged in a honeycomb configuration, each one with on-chip JFET. The layout of the array is shown in Fig. 1. Despite the small active area of the array (7 5 mm 2 ), the results achieved with this prototype can be already indicative of the performances achievable with larger detectors based on the same concept. Each SDD unit is characterized by an electronics noise of about 77 and 3 electrons r.m.s., at 2 C and C respectively, at 6 µs shaping time. The typical quantum efficiency at 565 nm, wavelenght of the emission peak of the CsI(Tl) crystal, is of the order of 7 % (antireflecting coatings have not been implemented). A CsI(Tl) crystal, with a cross-section covering completely the SDD active area, has been coupled to the array by means of a.5 µm thick layer of Bicron BC-637 optical coupling. In order to enhance the position resolution capabilities by minimizing light reflections on the crystal surfaces, no reflector was applied to the crystal. This solution, of course, does not optimize the light collection and consequently the energy resolution performances of the detector. For the determination of the position of interaction, by the centroid method, a multi-channel readout electronics including preamplifier, shaping amplifier, peak detector, ADC and a digital acquisition unit was previously developed [7]. B. Results An equivalent gain of 13 e - /kev was measured for the present detector configuration. This parameter has been evaluated first by calibrating the MCA in electrons per channel by irradiating only the SDD with a 55 Fe source and then by irradiating the scintillator-array assembly with a 57 Co source. The position resolution of the detector has been measured by moving a collimated 57 Co source (collimator diameter of.3 mm) over the horizontal axis of the detector in three different points separated by.6 mm. The measured position distributions, reported in Fig. 2, show the capability of the detector to distinguish the three source locations. However, the values of source distances in the measured distributions are significantly reduced with respect to reality, mainly due to edge effects related to the limited size of the scintillator and of the SDD array. The measured energy resolution was 13 % FWHM at 122 kev (Fig. 3). All the measurements have been carried out at C. In Fig. 4a, a test pattern opened on a lead layer (2 mm thick) is shown. A first gamma image of the test drawing has been obtained by irradiating the detector with a 57 Co source through the patterned layer. The result of the measurement is shown in Fig. 4b. Although evident distortions due to border effects of the detector affect the measured image, this first results already shows the detector capability to identify the small details of the drawing. Detector based on SDD arrays of larger size (19 and 61 cells, 1 cm 2 and 3 cm 2 active area respectively), already in production at MPI, could provide in principle the same imaging capability but with a larger active area. III. SDD WITH EXTERNAL JFET A. Methods Single-unit SDDs of larger areas with respect to the ones previously described have been recently realized at MPI. All these detectors have been produced without integrated JFET. The reduced complexity of the production process, with respect to SDDs with on-chip JFET, has allowed to obtain small values of leakage current. A current of about 2 pa has been measured at room temperature (2 C) for a 3 mm 2 detector. In the following, the experimentation of the 3 mm 2 SDD is described. The detector layout is shown in Fig. 5. The detector shape has been chosen to easily realize an array of single units closely assembled. For the connection between SDD and front-end electronics, the detector anode has been bonded to the gate of a Digifet from Gresham (UK), glued on the same ceramic of the detector chip. The Digifet is a n-channel JFET characterized by a nominal gate capacitance of.9 pf and a measured transconductance of 4.4 ms. On the Digifet chip, also a feedback capacitor of.15 pf was integrated. The following part of a charge preamplifier, suitable designed with the Digifet as input transistor and with the on-chip feedback capacitor, has been mounted very close to the ceramic holder. In order to characterize a single unit SDD-scintillator, the SDD has been coupled to a CsI(Tl) scintillator 1 mm thick. The crystal has a cross-section of the same shape of the SDD layout shown in Fig. 5, just slightly smaller (about.2 mm on each side) in order to allow the bonding connections of the SDD at the extremity of its active area. The scintillator was wrapped with white Millipore filter paper and coupled to the SDD by means of a layer of Bicron BC-637 optical coupling. B. Results The SDD was first test with direct X-ray irradiation of 55 Fe and 241 Am radioactive sources. In Fig. 6, the spectrum of the 241 Am source measured at room temperature with a semigaussian shaping time of.5 µm is shown. The measured energy resolution at 6 kev was 55 ev and 6 ev at.5 µs and 6 µs shaping time, respectively. Further studies on the same detector, not here reported, have shown that the

3 resolution was limited mainly by partial collection of the charge at the SDD anode. This limitations are strictly connected to a low drifting field inside the detector due to a low value of depletion voltage (= the voltage required to fully deplete the detector wafer) which was only 3V. This value in the present detector corresponds approximately to a wafer resistivity of about 6 kωcm, much higher than foreseen. This problem will be overcome in further productions where SDD with higher depletion voltage, leading to a higher drifting field, will be realized. In Fig. 7 the spectrum of a 137 Cs source measured at room temperature (2 C) and with 6 µs shaping time is shown. The resolution at the 662 kev peak is 5.2 % FWHM. An energy threshold around 3 kev can be set by the identification of the Ba-X line. In Fig. 8 the spectrum of a 152m Eu source measured at C and 12 µs shaping time is shown. The resolution at the 122 kev peak is of 8.4 % FWHM (1.9 % FWHM was measured at 2 C). Finally, in Fig. 9 the spectrum of a 241 Am source measured at C and 12 µs shaping time is reported. The energy resolution at the 59.5 kev peak is of 11.9 % FWHM and the energy threshold at this temperature is around 1 kev. With the present detector was also possible to show experimentally the capability of this configuration to operate in an extended energy range, as recently proposed [8]. The two 241 Am spectra shown in the same pulse height distribution reported in Fig. 1 has been measured by placing the source on the opposite side of the SDD with respect to the side where the scintillator was optically coupled. The two spectra are due respectively to direct detection by the SDD and to indirect detection by means of the scintillator. From the spectra, a system gain of 35 e-/kev was also evaluated. This measurement shows how the SDD-scintillator detector could operate in principle in a wide energy range, from few kev (direct detection) to hundreds kev or even few MeV (indirect detection by means of a scintillator). This feature could be of interest in astrophysics applications, where often two sets of different kind of detectors are required to cover the kev-mev energy range, and in X-ray and γ-ray dosimetry. The discrimination between direct spectrum and indirect spectrum could be carried out for instance by implementing a pulse-shape-discrimination. In fact, while the preamplifier pulse (Fig. 11a) corresponding to a direct SDD detection is characterized by a fast rise-time, the pulse corresponding to a SDD-CsI(Tl) detection (Fig. 11b) is characterized by a slow rise-time, limited by the scintillator decay time and by the SDD drift time (this last contribution being negligible in the direct detection). IV. CONCLUSIONS In this work we have presented the recent results obtained in the development of SDDs to be used with scintillators for high-resolution gamma-ray imaging. First, a small imaging detector based on a monolithic arrays of seven SDD with onchip JFET coupled to a single CsI(Tl) scintillator has show a capability of discriminating position of interactions separated by.6 mm, as well as imaging capability. The achieved energy resolution is 16 % FWHM at 122 kev. Detector of the same kind but with larger active are now under development. These detectors, which are identical for topology, are expected to show similar performances. The first results on the characterization of single SDD of larger area and with external JFET have also shown satisfactory performances. An energy resolution of 8.4 % FWHM at 122 kev and a threshold of 1 kev have been measured at C. Detectors of this kind will be assembled in arrays in order to cover a more extended active area, as required by several applications in Astrophysics and Nuclear Medicine. SDD of 1cm 2 have been also produced and they will be tested in the short future. V. ACKNOWLEDGMENT The authors would like to thank A. Delzanno for the help during the measurements. VI. REFERENCES [1] G.J. Gruber, et al., "A discrete scintillation camera module using silicon photodiode readout of CsI(Tl) crystals for breast cancer imaging", IEEE Trans. Nucl. Science, Vol. 45, n. 3, pp. 163-168, 1998. [2] B.E. Patt, et al., "High resolution CsI(Tl)/Si-PIN detector development for breast imaging", IEEE Trans. Nucl. Science, Vol. 45, n. 4, pp. 2126-2131, August 1998. [3] E. Labanti, et al., "PICsIT: the high-energy detection plane of the IBIS instrument on-board INTEGRAL", Proc. SPIE, Vol. 286, p.269, 1996. [4] E. Gatti, and P. Rehak, "Semiconductor drift chamber - An application of a novel charge transport scheme", Nucl. Instr. and Meth., A 225, 68, 1984. [5] C. Fiorini, A. Longoni, F. Perotti, C. Labanti, P. Lechner and L. Strüder, "Gamma Ray Spectroscopy with CsI(Tl) Scintillator coupled to Silicon Drift Chamber", IEEE Trans. Nucl. Science, Vol. 44, n. 6, pp. 2553-256, 1997. [6] C. Fiorini, F. Perotti, C. Labanti, A. Longoni, E. Rossi, "Position and Energy Resolution of a new Gamma-ray Detector based on a single CsI(Tl) Scintillator coupled to a Silicon Drift Chamber Array", IEEE Trans. on Nucl. Sci., Vol. 46, n. 4, 858-864, 1999. [7] C. Fiorini, A. Longoni, F. Perotti, C. Labanti, E. Rossi, P.Lechner and L.Strüder, First Prototype of a Gamma-Camera Based on a Single CsI(Tl) Scintillator Coupled to a Silicon Drift Detector Array, IEEE Trans. on Nucl. Sci, Vol. 47, n. 6, pp. 1928-1932, December 2. [8] C. Labanti, et al., Silicon drift chamber with extended energy range, Proc. SPIE, Vol. 414, pp.324-332, 2.

4 Fig. 1. Layout of the monolithic array of seven-sdds. The detector side where the drift rings and the front-end JFET are integrated is shown in the figure. The scintillator is coupled to the opposite side of the detector. 4 3.5 3 2.5 Y 2 [mm] 1.5 1.5 1 2 3 4 X [mm] Fig. 2. Measured position distribution corresponding to three different interaction points separed by.6 mm.

5 3 25 122 kev 2 15 16 % FWHM 1 5 5 1 15 2 Energy [kev] Fig. 3: Energy spectrum measured with the SDD array coupled to the single CsI(Tl) scintillator at C.

6.5 mm 1 mm (a) (b) Fig. 4. (a) Pattern opened on a lead collimator. (b) Measured position distribution of the gamma-ray interactions produced by the 57 Co source through the collimator.

7 Fig. 5. Layout of the 3 mm 2 SDD with external JFET. 1 1 1 11.9 kev 13.9keV 17.6 kev 2.9keV 26.3keV 241 Am T=24 C 59.5 kev 1 1 1 2 3 4 5 6 Energy [kev] Fig. 6. Spectrum of the 241 Am source measured at room temperature (24 C) with the SDD at.5 µs shaping time.

8 5 4 32 kev Ba X-ray 137 Cs T=2 C 3 2 1 5.2% FWHM 662 kev 1 2 3 4 5 6 7 8 Energy [kev] Fig. 7. Spectrum of the 137 Cs source measured at room temperature with the CsI(Tl)-SDD detector. 3 152m Eu T= C 122 kev 2 4 kev 8.4% FWHM 1 escape Fig. 8. Spectrum of the 135m Eu source measured at C. 2 4 6 8 1 12 14 16 Energy [kev]

9 4 241 Am T= C 59.5 kev 3 2 17.6 kev 11.9% FWHM 1 escape 1 2 3 4 5 6 7 8 Energy [kev] Fig. 9: Spectrum of the 241 Am source measured at C. 8 6 59.5keV 6 4 17.6 kev 59.5keV 241 Am 4 17.6 kev 2 13.9keV 11.9 17.6keV kev 2 4 6 2 13.9keV 17.6keV 2.9keV 59.5keV 5 1 15 2 Channels Fig. 1. Spectra of the 241 Am source measured at C respectively by means of direct detection with the SDD and by means of detection with the scintillator-sdd system (patterned region of the pulse height distribution).

1 (a) (b) Fig. 11. Examples of two pulses at output of the preamplifier in correspondence of (a) an event detected directly by the SDD, (b) an event detected by the scintillator. The different rise times in the two cases are clearly visible.