close to performances of the turbine gas meters designed for custody transfer measurements.

Similar documents
Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Volumetric Flow Measurement

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Thermal Mass Flow Meter for Gases

Page 1 of 16 Issue No. 0 of IECEx TUN X

14:1400 (0206) KRAL Volumeter - OMG

VD1 CLC. Small Valves DIN-range with a higher k v -value

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

AWM3000 Series Mass flow sensor for gases

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

THREADED CLOSURES. For access to Filter Vessels, Strainers, Pig Launchers & Receivers. Tube Turns Products

Cooling Water Flow Regulator

Oscillation Flow Meter for Gases

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016


Ultrasonic Gas Flow Meter

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

331 Low & Medium Pressure filters

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Suction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters

Full Metal Variable Area Flow Meter and Counter

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

High Pressure fi lters

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

387 Low & Medium Pressure filters

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

Integral V-Cone Flowmeter VD series

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

Electromagnetic Flowmeter

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters

Installation guide 862 MIT / MIR

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Natural Gas Measurement Using Temperature-Dependent Thermal Conductivity

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

Index to Tables in SI Units

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

Ultra-High Vacuum Technology. Sputter Ion Pumps l/s

ED 701 General Industry Pressure Transmitter

ALASTAIR MCLACHLAN Applications Cameron

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

CHEMISTRY MOLES PACKET 2017 NAME: PER:

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

Target Insertion Flowmeter

Conductivity sensor for hygienic applications

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Orifice and Venturi Pipe Flow Meters

Orifice and Venturi Pipe Flow Meters

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

The New ISO Advances and new concepts in the performance evaluation and benchmarking of on line natural gas analysers.

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

Using 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV

tekcor TKC Multivariable Coriolis Flow Sensors

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

Rotary modules.

SST Tag: Message: (32 characters)

Electronic pressure-independent characterised control valve EPIV

Pressure Measurement Single-range transmitters for general applications

V-Cone Flowmeter DATASHEET

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Precision Ball Screw/Spline

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina

SPECIFICATION. Topview 5550 SMD LED IWS 505-UG-K3. Product : Topview 5550 SMD LED Part No : IWS-505-UG-K3 Customer : Date : Ver.1.

INTERNATIONAL STANDARD

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

Relative Sensitivity RS Measurements of Gases

Accumulators Virginia KMP Suction Line Accumulators

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

PR CYCLONE SECONDARY SHUTOFF

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

Model Selection 1. Process Valves. Air. Vacuum

CNG measuring systems for vehicles

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

SPECIFICATION. Checked By Checked By Checked By Checked By Approval. Proposed By Checked By Checked By Checked By Approval

Transcription:

QUANTOMETER

DESIGN AND FUNCTION CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flow measurements. Our great experience in designing and manufacturing of turbine and rotary gas meters resulted in the development of industrial quantometers. Taking into account our customers demands we created the instrument with excellent metrological characteristics and operating performance close to performances of the turbine gas meters designed for custody transfer measurements. Other advantages of the CPT Quantometers are as follows: high quality, easy maintenance, wide range of external devices that can co-operate with the quantometers, e.g. volume correctors, data loggers, data transmission systems. Due to that the CPT Quantometers are well accepted by our domestic and foreign customers. The basic components of the CPT Quantometer are as follows: pressure resistant meter body inlet flow conditioner measuring cartridge with the turbine wheel magnetic coupling as the transferring element between measuring cartridge and the index index head Gas Chemical symbol (formula) Density ρ [kg/m 3 ] Density related to air Gas meter execution Argon Ar,66,38 Butane C 4 H 0 2,53 2,0 Carbon dioxide CO 2,84,53 Carbon monoxide CO,6 0,97 Ethane C 2 H 6,27,06 Ethylene C 2 H 4,7 0,98 Helium He 0,7 0,4 Methane CH 4 0,67 0,55 Natural gas - ~0,75 ~0,63 Nitrogen N 2,6 0,97 Propane C 3 H 8,87,56 Acetylene C 2 H 2,09 0,9 special IIC Hydrogen H 2 0,084 0,07 special IIC Air -,20,00 table : Physical properties of most popular gases that may be measured with the CPT Quantometer; density at 0,325 kpa and at 20 C

2 GENERAL TECHNICAL DATA table 2: DN inch G Maximum flow Q max [m 3 /h] Minimum flow Q min [m 3 /h] LF pulse rate [m 3 /pulse] 50 80 50 2 3 4 6 40 60 60 0 0 60 0 0 0 600 6 0 8 3 20 3 20 32 32 50 80 0, 0 pressure rating: PN6, PN20, ANSI50 nominal diameter: DN50 up to DN50 standard range, other on request meter bodies: aluminium flow: 6 to 600 m 3 /h other on request rangeability: :20 minimum at atmospheric pressure e Some smaller size meters have reduced ranges. temperature range: gas temperature -20 C to +60 C ambient temperature -25 C to +70 C allowed medias: see table operating position: horizontal or vertical DN50 DN80 DN A B C E F G H Weight M6 bolt No x L kg 8 40 99 252 3,6 4 x 80 20 80 2 50 77 2 278 5,3 8 x 200 50 29 9 225 305 7,4 8 x 235 27 50 90 6 243 35,6 8 x 270 Note: No and lenght of bolts is for PN6 flanges only. fig. Basic dimensions of CPT Quantometer

3 MEASUREMENT OUTPUTS PRESSURE OUTPUT The operating pressure (reference pressure) can be taken from the pressure tap, marked pr, located on one side of the meter body. PULSE SENSORS The mechanical index unit indicates the actual volume of the measured gas at operating temperature and operating pressure. It can be rotated axially by 350 in order to facilitate the readings and enable easier connection of pulse sensor plugs. The index unit is provided with one low frequency LFK reed contact pulse transmitter, as a standard. On request the index may be equipped with: - LFI inductive pulse sensor (NAMUR) - HF inductive pulse sensor (NAMUR) HF, HF2 Ui = 6 V DC Ii = 25 ma Pi = 64 mw Li = 50 μh Ci = 30 nf LFI, HF3 Ui = 5,5 V DC Ii = 52 ma Pi = 69 mw Li 40 μh Ci = 28 nf LFK, AFK Ui = 5,5 V DC Ii = 52 ma Pi = 69 mw Li 0 Ci 0 table 3: Permissible supply parameters of intrinsically safe circuits. fig. 2 Location of measurement outputs (top view) The CPT Quantometers may be provided with up to 7 pulse sensors: LFK low frequency reed contact pulse sensor LFK, LFK 2 LFI low frequency inductive pulse sensor LFI, LFI 2 HF inductive pulse sensor in the index unit HF, HF 2 HF inductive pulse sensor over the turbine wheel HF 3 AFK anti-fraud reed contact AFK The turbine wheel, as a standard, is made of aluminium. This allows to provide each CPT Quantometer with one HF3 inductive pulse sensor. There are no extra costs due to the replacement of the turbine wheel. Pin No Socket pulse sensors Socket 2 pulse sensors Pin No HF over turbine wheel - 4 LFK (standard) LFK 2 3-4 HF 3 2-5 LFI LFI 2 3-6 HF or AFK HF 2 fig. 3 Pulse sensor pin numbering in sockets and 2 installed in the index. The sockets match the TUCHEL plug No C09 3H006 2 fig. 4 Pulse sensor pin numbering in socket of the HF3 pulse transmitter installed in the meter body. The sockets match the TUCHEL plug No C09 3D004 2

4 SELECTION OF CPT QUANTOMETER In order to choose the proper size of the turbine quantometer the following operating condition parameters should be known: flow range Q min m and Q max m, pressure range p min m and p max m, gas temperature range T min m and T max m Usually flow range is given at standard conditions: Q min s and Q max s. Base conditions (NPTconditions: base temperature and base pressure) are country specific. The following formula is to be used when converting standard flow cubic meters per hour into actual flow at operating conditions: Q min m = Q min s Z p max m T min m T s Q max m = Q max s Z T max m p min m T s The quantometer size should be chosen (using actual flow at operating conditions) according to the following formula: Q min (Q min C ) < Q min m Q max > Q max m where Q min and Q max minimum and maximum flow, according to table 2. The measurement range increases with increase of operating pressure. The corrected Q min C value decreases, and it may be calculated from the following formula: Q min C = Q min ρ a / ρ m where ρ m = (p m +) ρ s DEFINITION: Q min m = minimum fl ow at operating conditions [m 3 /h] Q max m = maximum fl ow at operating conditions [m 3 /h] Q min s = minimum flow at base conditions [Nm 3 /h] Q max s = maximum flow at base conditions [Nm 3 /h] Q min C = corrected minimum flow [m 3 /h] = base pressure (according to national standards) [bar a] T s = base temperature (according to national standards) [K] ρ s = standard density of the gas [kg/m 3 ], see table p m ρ m ρ a p max m p min m T max m T min m Z = gauge pressure at operating conditions [bar g] = density at operating conditions [kg/m 3 ] = standard density of air,2 kg/m 3 = maximum operating pressure [bar a] = minimum operating pressure [bar a] = maximum operating temperature [K] = minimum operating temperature [K] = real gas factor at operating conditions (for PN6 Z ) COMMON S.A. has continuing program of product research and development. Technical specifications and construction may change due to improvements. This publication serves as general information only, and all specifications are subject to confirmation by COMMON S.A.

5 6 PRESSURE LOSS The inevitable pressure loss during the gas flow through the meter is determined at the atmospheric conditions. ρ To determine pressure losses at other, higher p = ( s p ) ( m + ) p pressures, the following formula applies: ρ a 3000 0 p[pa] 0 DN50 DN80 DN DN50 0 0 Q [m 3 /h] fig. 5 Diagram of pressure loss related to ρ =,2 kg/m 3 DEFINITION: p = pressure loss at p p = pressure loss from the diagram, fi g. 5 p m = gauge pressure at operating conditions [bar g] ρ s = standard density of gas [kg/m 3 ] ρ a = standard density of air,2 kg/m 3 = base pressure (,0325 bar) INSTALLATION AND OPERATION RECOMMENDATIONS 2000 Meters should be shipped in their original package to the place of installation. The measured gas should be clean, dry and free from solid impurities. It is recoended that the upstream pipe installation is to be equipped with a filter (0 micron). Prior to installation the upstream and downstream pipe fl anges should be aligned properly. The gas fl ow should be in accordance with the arrow placed on the meter body. When used outdoors the meter should be protected against direct weather infl uence. When starting the gas flow through the installation, the valves should be opened slowly to ensure a gradual increase of pressure. ALWAYS REMEMBER TO START UP THE METERS IN A PROPER WAY! COMMON S.A. ul. Aleksandrowska 67/93 9-205 Łódź, Poland tel. + 48 42 253 66 57 + 48 42 253 66 58 fax + 48 42 253 66 99 http://www.coon.pl e-mail:coon@coon.pl Your Partner PR: CPT/EN/0/03.06