Eppendorf SmartBlock. Instructions for use

Similar documents
N) manual. Biomaster Operating manual

Eppendorf UVette. Instructions for use

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

The Value of Mixing. Eppendorf Temperature Control and Mixing Instruments

Eppendorf Vis Cuvettes. Instructions for use

Multiple Talents. Eppendorf Temperature Control and Mixing Instruments

stance et Helper Eppendorf Pipet Helper Chemical Resistance

NEW: 5.0 ml screw cap tube. The Missing Link. Eppendorf Tubes 5.0 ml Discover a new sample handling system

Electrical safety testing Checklist

The Pure Truth. Eppendorf Forensic DNA Grade according to ISO 18385

ept.i.p.s. Instructions for use Version B

symphony Reference Electrodes

Eppendorf Temperature Verification System. Operating manual /0909

NEW. A class of its own. Centrifuge 5430 / 5430 R

Now also in Eppendorf LoBind. Conical Competence. Eppendorf Conical Tubes 15 ml and 50 ml

Eppendorf Xplorer Eppendorf Xplorer plus. Ordering information. Register your instrument!

N) justment. Register your instrument! Eppendorf Research plus. Factory Adjustment

High-throughput Isolation of Genomic DNA From Buccal Swab on the Eppendorf epmotion 5075 VAC

Eppendorf BioSpectrometer 6135/6136/6137

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

symphony Multisensor Probes

The New Legend. Eppendorf Reference 2 Pipette

Exchangeable Thermoblock for slides DC Operating instructions

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 0

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

ept.i.p.s. Version A

DOC /2013, Edition 1. User Manual

Cleaning and Decontamination of the ept.i.p.s. Box

Automated pipetting made easy new ep Motion 5073 family members for perfect PCR set-up and nucleic acids purifi cation or general liquid handling

PhysioCare Concept. Make your Lab a better place

Centrifuge 5427 R. Sample Handling Centrifuges CENTRIFUGES

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

No 022 December Application-Specific Requirements for Consumables in the Laboratory

Automated purification of high quality genomic DNA

NEW! ep Dualfilter T.I.P.S. Peak of perfection

NGS Made Easy. Optimize your NGS library preparation with the epmotion Automated liquid handling system

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

Lamp and Control Panel (Lamp Panel)

stance 4 Repeater M4 Register your instrument! Multipette M4 Repeater M4 Chemical Resistance

In-Solution Digestion: Multi-Plate v1.0 Quick Start Guide

Requirements to perform accurate dielectric material analysis

u s e r m a n u a l w w w. v e l a. E U

Spa & Wellness for Pipettes

Well within Reach. The Eppendorf Pipette Holder System

mag nanogram kit Description Kit uses

THE POWER OF ASTRONERGY

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

The Next Stage. The new Mastercycler X50

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

Instruction Manual SEFRAM Thermal Camera

Micro Volume QuEChERS kit

PhysioCare Concept improved. The feeling of a new philosophy

PhysioCare Concept improved. The feeling of a new philosophy

3B SCIENTIFIC PHYSICS

The New Legend. Eppendorf Reference 2 Pipette

POWER PUSHER Snowplow

EU-IVD Products included. The Next Benchmark. Eppendorf Centrifuge 5910 R and Centrifuge 5920 R

The information contained in this SOP is general in nature. Any YouTube videos included are as a compliment to the information presented.

3B SCIENTIFIC PHYSICS

Please use only the valid version of the package insert provided with the kit. This kit is intended for Research Use Only.

Cell Biology (Eukaryotic Cells)

Comparative Analysis of Protein Recovery Rates in Eppendorf LoBind and Other Low Binding Tubes

VELA Tango 100. VELA Tango 100A. VELA Tango 200 GAS

Endless Possibilities

Must Read Before Installation TadPoleTM Safety and Warnings

3B SCIENTIFIC PHYSICS

Department of Environmental Health and Safety Laboratory Decommissioning and Clearance

Operating Instructions for Digital Manometer. Model: MAN-SD

Easy Illumina Nextera DNA FLEX Library Preparation using the epmotion 5075t automated liquid handler

Superior well-to-well Consistency with Eppendorf Cell Culture Plates

Technical Report Eppendorf Deepwell Plates and Microplates Investigations of sealing methods

Food Safety and Quality Management System

Applications Note 164 October 2007

Applications Note 202 October 2008

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 1

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7

Technology that counts

Precise and Accurate whole Blood Dispensing with Multipette E3x and Combitips advanced

FOR RESEARCH USE ONLY.

Manual Dew point scanner PCE-DPT 1

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

Crime Prep Adem-Kit (Cat #06210) Instruction for manual protocol

LEAPERS, INC. RED/GREEN DOTS

Get More! Quality Stability Purity: Eppendorf Plates

Automated Illumina TruSight HLA v2 Sequencing Panel Library Preparation with the epmotion 5075t

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

THE UNIVERSITY OF NEWCASTLE SCHOOL of BIOMEDICAL SCIENCES

Type B xxx/60. Snowplough // USER MANUAL Version 1.0 EN. Art.Nr.:

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

Technology that counts

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual

Automated Illumina TruSeq DNA PCR-Free library construction with the epmotion 5075t/TMX

Instructions for use. Glycine ELISA BA E-2100

QAM-I-116 Preparation of Labware

Objective: Science Classroom Laboratory Safety

Processing TEM Grids with mprep/g Capsules

Installation guide 862 MIT / MIR

Transcription:

Instructions for use

Instructions Eppendorf see Fig. Tab. p. p. SmartBlock for use Copyright 2016 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication may be reproduced without the prior permission of the copyright owner. Eppendorf and the Eppendorf logo are registered trademarks of Eppendorf AG, Germany. Eppendorf ThermoMixer, Eppendorf ThermoTop, and condens.protect are registered trademarks of Eppendorf AG, Germany. Eppendorf ThermoStat and Eppendorf SmartBlock are trademarks of Eppendorf AG, Germany. Registered trademarks and protected trademarks are not marked in all cases with or in this manual. English Instructions (EN) for use 5363 900.005-03/092016

Operating instructions 3 1 Operating instructions 1.1 Using this manual These instructions for use are a supplement to the operating manual of the Eppendorf ThermoMixer C and Eppendorf ThermoStat C devices. These instructions for use do not replace the operating manual. Read the operating manual of the corresponding device before using the thermoblock for the first time. The current version of the operating manual can be found on our website at www.eppendorf.com/manuals. 2 Safety 2.1 Intended use Eppendorf SmartBlocks are thermoblocks for the devices Eppendorf ThermoMixer C and Eppendorf ThermoStat C and are used to hold tubes and plates during sample preparation and during temperature control and mixing of samples. The thermoblocks are intended exclusively for indoor use. All country-specific safety requirements for operating electrical equipment in laboratories must be observed.only use Eppendorf accessories or accessories recommended by Eppendorf. The thermoblocks must only be operated by appropriately qualified and instructed personnel. The product can be used for training, routine and research laboratories in the areas of life sciences, industry or chemistry. This product is intended to be used for research purposes only. Eppendorf does not provide a warranty for other applications. The product is not suitable for use in diagnostic or therapeutic applications. The product may only be used by skilled personnel who have been trained in the areas mentioned above. 2.2 Danger symbols on the device Depiction Meaning Location Risk of burns from hot surfaces. On the thermoblock Hazard point Risk of injury from moving parts. On the thermoblock Observe the operating manual.

4 Product description 3 Product description 3.1 Features The thermoblocks (SmartBlocks) for the Eppendorf ThermoMixer C and Eppendorf ThermoStat C allow efficient temperature control and mixing of samples in lab vessels in the microliter and milliliter ranges. Thermoblock Vessels/Plates Maximum mixing frequency Maximum temperature SmartBlock 0.5 ml Tube volume 0.5 ml 2 000 rpm 100 C SmartBlock 1.5 ml Tube volume 1.5 ml 2 000 rpm 100 C SmartBlock 2.0 ml Tube volume 2.0 ml 2 000 rpm 100 C SmartBlock 5.0 ml Tube volume 5.0 ml 1 000 rpm 100 C SmartBlock 12 mm Tubes with a diameter 2 000 rpm 110 C* of 11 mm to 11.9 mm SmartBlock cryo Cryotubes 2 000 rpm 110 C* SmartBlock 15 ml Conical tubes 1 000 rpm 100 C volume 15 ml SmartBlock 50 ml Conical tubes 1 000 rpm 100 C volume 50 ml SmartBlock plates** Microplates 3 000 rpm 100 C Deepwell plates 2 000 rpm 1 000 rpm < 80 C > 80 C SmartBlock PCR 96 96-well PCR plates, PCR 2 000 rpm 100 C tubes 0.2 ml SmartBlock PCR 384 384-well PCR plates 3 000 rpm 100 C SmartBlock DWP 500*** Eppendorf Deepwell 1 600 rpm 100 C Plates 96/500 μl SmartBlock DWP 1000*** Eppendorf Deepwell Plates 96/1000 μl 1 600 rpm 100 C * Only in combination with Eppendorf ThermoStat C. ** The height sensor of the SmartBlock plates automatically differentiates between deepwell plates and microplates. *** SmartBlock DWP 500 and SmartBlock DWP 1000 can only be used with Eppendorf Deepwell Plates (optimal fit and temperature transfer).

Installation and operation 5 4 Installation and operation 4.1 Installing the thermoblock WARNING! Personal injury or material damage due to chemically or mechanically damaged thermoblocks. Do not use thermoblocks that show signs of corrosion or mechanical damage. Regularly check the condition of the thermoblocks. WARNING! Contamination due to opening seals of consumables. In the following cases, the seals of tubes or plates can spring open. Sample material can escape. high vapor pressure of the content improperly sealed cover damaged sealing lip improperly fastened foil Always check that consumables have been sealed tightly before use. When you attach the thermoblock, the device automatically recognizes the mounted thermoblock. The Eppendorf ThermoMixer C limits the mixing frequency to the maximum value for the used thermoblock. The Eppendorf ThermoStat C limits the temperature to the maximum value for the used thermoblock. 4.1.1 Attaching the thermoblock CLICK 1. First only attach the rear edge of the thermoblock. The writing must face to the front. 2. Push the front edge of the thermoblock down. The thermoblock audibly engages. The display shows the name of the thermoblock.

6 Installation and operation 4.1.2 Removing the thermoblock WARNING! Risk of burns from hot surfaces. The thermoblock and the heating/cooling plate can be very hot after heating and cause burns. Allow the thermoblock and heating/cooling plate to cool down completely before removing the thermoblock. 1. To unlock the thermoblock, press the lever at the front of the thermoblock down. 2. Lift the front edge so that the thermoblock is tilted backwards. 3. Remove the thermoblock upwards. 4.2 Inserting tubes and plates WARNING! Risk of injury due to incorrect consumables. Poorly fitting tubes or plates can become detached from the thermoblock. Glass tubes can smash. Only use the thermoblocks with the consumables designed for them. Never use tubes made of glass or other fragile material. NOTICE! Damage to plates due to too high temperatures. Polystyrene microplates melt at temperatures above 70 C. Polypropylene deepwell plates may deform at temperatures above 80 C. Deformed plates can become detached from the thermoblock or may be more difficult to remove. Only heat polystyrene microplates up to 70 C. NOTICE! Material change of consumables due to extreme temperatures. Extreme temperatures (e.g., during refrigeration or autoclaving) affect consumables material. The mechanical strength, dimensions and shape of the consumable will change. Use consumables that are suitable for the selected temperature range or selected procedure.

Installation and operation 7 4.2.1 Inserting tubes Only use closed tubes. Insert the tubes completely into the bores of the thermoblock. 4.2.2 Inserting the plate The height sensor of the SmartBlock plates distinguishes automatically between deepwell plates and microplates. Make sure not to cover the height sensor when inserting microplates. Take care that the height sensor does not get contaminated. Abb. 4-1:1 Height sensor SmartBlock plates 1 Fig. 4-1: 1 Height sensor SmartBlock plates Only use closed plates. Insert the plate with the back edge first. Then press it down at the front. To ensure uniform temperature control of all wells, place the lid on the thermoblock. 4.3 Removing deepwell plates (only SmartBlock DWP 500 and SmartBlock DWP 1000) In some cases, deepwell plates may be more difficult to remove from the thermoblock after heating to 80 C and then cooling to 10 C. This is caused by the material properties of the deepwell plates. Remove the deepwell plate with both hands.

8 Maintenance 5 Maintenance 5.1 Cleaning WARNING! Risk of burns from hot surfaces. The thermoblock and the heating/cooling plate can be very hot after heating and cause burns. Allow the thermoblock and heating/cooling plate to cool down completely before removing the thermoblock. NOTICE! Damage from the use of aggressive chemicals. Do not use any aggressive chemicals on the device or its accessories, such as strong and weak bases, strong acids, acetone, formaldehyde, halogenated hydrocarbons or phenol. If the device becomes contaminated with aggressive chemicals, clean it immediately using a mild cleaning agent. NOTICE! Corrosion from aggressive cleaning agents and disinfectants. Do not use corrosive cleaning agents, aggressive solvents or abrasive polishes. Auxiliary equipment Lint-free cloth Soft bottle brush or cotton swabs Mild soap-based laboratory cleaner Dist. water Clean the thermoblock immediately if sample fluid enters the bore holes or comes into contact with the surfaces. 1. Clean the thermoblock with a mild soap solution. Clean the bores with a soft bottle brush or cotton swabs. 2. Rinse off the soap solution with dist. water. 3. Let the cleaned thermoblock dry with the bores pointing downwards. Do not dry thermoblocks in a drying cabinet.

Transport, storage and disposal 9 5.2 Disinfection/decontamination WARNING! Risk to health due to contaminated accessories. 1. Follow the instructions in the decontamination certificate. You can find it as a PDF file on our webpage (www.eppendorf.com/decontamination). 2. Decontaminate all the parts you would like to dispatch. 3. Include the fully completed decontamination certificate for returned goods in the packing. Select a disinfection method complying with the statutory rules and regulations for your area of application. Use e.g. alcohol (ethanol, isopropanol) or alcohol-containing disinfectants. 6 Transport, storage and disposal 6.1 Disposal In case the product is to be disposed of, the relevant legal regulations are to be observed. Information on the disposal of electrical and electronic devices in the European Community: Within the European Community, the disposal of electrical devices is regulated by national regulations based on EU Directive 2012/19/EU pertaining to waste electrical and electronic equipment (WEEE). According to these regulations, any devices supplied after August 13, 2005, in the business-to-business sphere, to which this product is assigned, may no longer be disposed of in municipal or domestic waste. To document this, they have been marked with the following identification: Because disposal regulations may differ from one country to another within the EU, please contact your supplier if necessary.

10 Ordering information 7 Ordering information 7.1 Device and accessories Order no. (International) Order no. Description (North America) Eppendorf ThermoMixer C basic device without thermoblock 5382 000.015 220 V 240 V 5382000023 100 V 130 V Eppendorf ThermoStat C basic device without thermoblock 5383 000.019 220 V 240 V 5383000027 100 V 130 V Eppendorf ThermoTop 5308 000.003 5308000003 with condens.protect technology Lid for Eppendorf ThermoMixer F0.5/F1.5/F2.0/FP 5363 000.233 5363000233 for SmartBlocks 0.5 ml, 1.5 ml, 2.0 ml, plates, PCR 96, PCR 384, DWP 500, DWP 1000 SmartBlock 0.5 ml 5361 000.031 5361000031 Thermoblock for 24 tubes 0.5 ml SmartBlock 1.5 ml 5360 000.038 5360000038 Thermoblock for 24 tubes 1.5 ml SmartBlock 2.0 ml 5362 000.035 5362000035 Thermoblock for 24 tubes 2.0 ml SmartBlock 5.0 ml 5309 000.007 5309000007 Thermoblock for 8 tubes 5.0 ml SmartBlock 15 ml 5366 000.021 5366000021 Thermoblock for 8 conical tubes 15 ml SmartBlock 50 ml 5365 000.028 5365000028 Thermoblock for 4 conical tubes 50 ml SmartBlock 12 mm Thermoblock for 24 tubes 5364 000.024 5364000024 diameter 11 mm 11.9 mm, height 34 mm 76 mm SmartBlock cryo Thermoblock for 24 Cryo tubes 5367 000.025 5367000025 1.5 ml 2 ml, diameter max. 12,5 mm, all base shapes

Ordering information 11 Order no. (International) Order no. Description (North America) SmartBlock plates Thermoblock for microplates and deepwell plates 5363 000.039 5363000039 incl. Lid SmartBlock PCR 96 Thermoblock for PCR plates 96 5306 000.006 5306000006 incl. Lid SmartBlock PCR 384 Thermoblock for PCR plates 384 5307 000.000 5307000000 incl. Lid SmartBlock DWP 500 Thermoblock for Eppendorf Deepwell Plate 96/ 500 μl 5316 000.004 5316000004 incl. Lid SmartBlock DWP 1000 Thermoblock for Eppendorf Deepwell Plate 96/ 1000 μl 5310 000.002 5310000002 incl. Lid Transfer Rack 0.5 ml 3880 000.305 3880000305 for 0.5 ml tubes Transfer Rack 1.5/2.0 ml 3880 000.151 3880000151 for 1.5/2.0 ml tubes

Evaluate Your Manual Give us your feedback. www.eppendorf.com/manualfeedback Your local distributor: www.eppendorf.com/contact Eppendorf AG 22331 Hamburg Germany eppendorf@eppendorf.com www.eppendorf.com