Backscattered Electron Contrast Imaging of Scanning Electron Microscopy for Identifying Double Layered Nano-Scale Elements

Similar documents
Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

Depth Distribution Functions of Secondary Electron Production and Emission

Mercury(II) detection by SERS based on a single gold microshell

Auger Electron Spectroscopy Overview

PHYS-E0541:Special Course in Physics Gas phase synthesis of carbon nanotubes for thin film application. Electron Microscopy. for

Auger Electron Spectroscopy

HOW TO APPROACH SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE SPECTROSCOPY ANALYSIS. SCSAM Short Course Amir Avishai

h p λ = mν Back to de Broglie and the electron as a wave you will learn more about this Equation in CHEM* 2060

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

MSN551 LITHOGRAPHY II

Basic structure of SEM

Microscopy: Principles

The Method of Increasing COMPO Contrast by Linearization of Backscattering Characteristic η =f(z)

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Measurement of XANES Spectra of Biological Molecules in the Soft X-Ray Region

High-Precision Evaluation of Ultra-Shallow Impurity Profiles by Secondary Ion Mass Spectrometry

Everhart-Thornley detector

Monte Carlo study of medium-energy electron penetration in aluminium and silver

CBE Science of Engineering Materials. Scanning Electron Microscopy (SEM)

Auger Electron Spectroscopy (AES) Prof. Paul K. Chu

Geology 777 Monte Carlo Exercise I

Model : JEOL JSM 7610f

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Massachusetts Institute of Technology. Dr. Nilanjan Chatterjee

Electron Microprobe Analysis and Scanning Electron Microscopy

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

EDS User School. Principles of Electron Beam Microanalysis

Highly efficient SERS test strips

SUPPLEMENTARY NOTES Supplementary Note 1: Fabrication of Scanning Thermal Microscopy Probes

Supporting Information. Metallic Adhesion Layer Induced Plasmon Damping and Molecular Linker as a Non-Damping Alternative

Chapter 9. Electron mean free path Microscopy principles of SEM, TEM, LEEM

Supporting Information s for

Precision Cutting and Patterning of Graphene with Helium Ions. 1.School of Engineering and Applied Sciences, Harvard University, Cambridge MA 02138

Gold nanothorns macroporous silicon hybrid structure: a simple and ultrasensitive platform for SERS

Controlled Electroless Deposition of Nanostructured Precious Metal Films on Germanium Surfaces

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

Auger Electron Spectroscopy (AES)

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

Supporting information

ph-depending Enhancement of Electron Transfer by {001} Facet-Dominating TiO 2 Nanoparticles for Photocatalytic H 2 Evolution under Visible Irradiation

theoretical practice on grazing-exit energy dispersive X-ray spectroscopy as a surface analysis

Supplementary Information. Atomic Layer Deposition of Platinum Catalysts on Nanowire Surfaces for Photoelectrochemical Water Reduction

(1) CNR-Istituto LAMEL, Via Piero Gobetti n.101, Bologna, Italy (2) PASTIS-CNRSM SCpA, S.S.7 km 714.3, Brindisi, Italy

Nanosphere Lithography

MS482 Materials Characterization ( 재료분석 ) Lecture Note 5: RBS

Raman spectroscopy study of rotated double-layer graphene: misorientation angle dependence of electronic structure

ABC s of Electrochemistry series Materials Characterization techniques: SEM and EDS Ana María Valenzuela-Muñiz November 3, 2011

Electrochemical Deposition of Iron Nanoparticles on PPY and H terminated Si substrates. Karan Sukhija Co-op Term # 1 April 28 th, 2005

Supporting Information

object objective lens eyepiece lens

Electron-Induced X-Ray Intensity Ratios of Pb Lα/Lβ and As Kα/Kβ by kev Applied Voltages

Micro- and Nano-Fabrication of Stimuli-Responsive Polymers

AP5301/ Name the major parts of an optical microscope and state their functions.

EE 527 MICROFABRICATION. Lecture 5 Tai-Chang Chen University of Washington

Scanning Electron Microscopy

Crystalline Surfaces for Laser Metrology

Portable type TXRF analyzer: Ourstex 200TX

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

MSE 321 Structural Characterization

The Effect of Magnetic Field Direction on the Imaging Quality of Scanning Electron Microscope

Elastic Constants and Microstructure of Amorphous SiO 2 Thin Films Studied by Brillouin Oscillations

Photoemission Spectroscopy

Transmission Electron Microscopy

Characterization of zeolites by advanced SEM/STEM techniques

Single ion implantation for nanoelectronics and the application to biological systems. Iwao Ohdomari Waseda University Tokyo, Japan

The Cylindrical Envelope Projection Model Applied to SE Images of Curved Surfaces and Comparison with AFM Evaluations

Secondary Ion Mass Spectroscopy (SIMS)

Imaging Carbon materials with correlative Raman-SEM microscopy. Introduction. Raman, SEM and FIB within one chamber. Diamond.

Characterisation of atmospheric aerosol sampled from an aircraft using scanning electron microscopy

Methods of surface analysis

Friction and Elongation of Al Electrodes due to Micro-Sliding between the Inner Mo Electrode and the Al Electrodes in High-Power Devices

MICRO-FOUR-POINT PROBES IN A UHV SCANNING ELECTRON MICROSCOPE FOR IN-SITU SURFACE-CONDUCTIVITY MEASUREMENTS

The Benefit of Wide Energy Range Spectrum Acquisition During Sputter Depth Profile Measurements

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

Effects of Electron Backscattering in Auger Electron Spectroscopy: Recent Developments

Lecture 5. X-ray Photoemission Spectroscopy (XPS)

Nanotechnology Nanofabrication of Functional Materials. Marin Alexe Max Planck Institute of Microstructure Physics, Halle - Germany

Detector Needs of Spectroscopy

Supplementary information

Modern Optical Spectroscopy

Supplementary Information

SUPPLEMENTARY MATERIALS FOR PHONON TRANSMISSION COEFFICIENTS AT SOLID INTERFACES

Supporting Information. Temperature dependence on charge transport behavior of threedimensional

The Use of Synchrotron Radiation in Modern Research

Digitized single scattering nanoparticles for probing molecular binding

The Standard Auger Electron Spectra in The AIST DIO-DB(111); Ge(111)

The scanning microbeam PIXE analysis facility at NIRS

Spin-resolved photoelectron spectroscopy

Characterisation of Catalysts Using Secondary and Backscattered Electron In-lens Detectors

Cho Fai Jonathan Lau, Xiaofan Deng, Qingshan Ma, Jianghui Zheng, Jae S. Yun, Martin A.

Nanostructure Fabrication Using Selective Growth on Nanosize Patterns Drawn by a Scanning Probe Microscope

Simultaneous visualization of oxygen vacancies and the accompanying cation shifts in a perovskite oxide by combining annular imaging techniques

APPLICATION OF THE NUCLEAR REACTION ANALYSIS FOR AGING INVESTIGATIONS

Visualizing the bi-directional electron transfer in a Schottky junction consisted of single CdS nanoparticles and a planar gold film

Osaka Sangyo University, Nakagaito, Daito, Osaka , Japan

Electron beam scanning

Dual Beam Helios Nanolab 600 and 650

Praktikum zur. Materialanalytik

Transcription:

Journal of Surface Analysis Vol.17, No.3 (211) pp.341-345 Paper Backscattered Electron Contrast Imaging of Scanning Electron Microscopy for Identifying Double Layered Nano-Scale Elements Hyonchol Kim, 1 Tsutomu Negishi, 2 Masato Kudo, 2 Hiroyuki Takei, 1,3 and Kenji Yasuda 1,4* 1 Kanagawa Academy of Science and Technology, KSP East 31, 3-2-1 Sakado, Takatsu-ku, Kawasaki, Kanagawa 213-12, Japan 2 JEOL Ltd., 1-2 Musashino 3-Chome, Akishima, Tokyo 196-8558, Japan 3 Department of Life Sciences, Faculty of Life Sciences, Toyo University, 1-1-1 Izumino, Itakura-machi, Oura-gun, Gunma 374-193, Japan 4 Department of Biomedical Information, Division of Biosystems, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-1 Kanda-Surugadai, Chiyoda-ku, Tokyo 11-62, Japan *yasuda.bmi@tmd.ac.jp (Received: October 3, 21; Accepted: December 12, 21) Identification of double layered thin film elements by backscattered electron (BSE) contrast imaging by scanning electron microscope (SEM) was examined. A flat type sample was formed with an inner layer composed of five different element areas (Au,,, and ) 5 nm thick and a thin gold outer layer 2, 5, or 1 nm thick on a silicon substrate. Dependence of BSE intensities of the sample on the acceleration voltage of incident electrons was measured from 3 to 3 kv, and the acceleration voltage sufficient to discriminate different elements shifted from 8.8 to 1.2 kv depending on the increase of the thickness of outer gold layer. Moreover, the dependence of the substrate shape was also evaluated using /Au double layered spherical nano-shells. The contribution of the nano-shell diameter to the BSE intensity was tested using different sized nano-shells. The contribution was within 1% for times difference of the diameter of nano-shells. Results between flat thin film and the nano-shell were compared and those differences were within 6% for 1 to 2 kv of acceleration voltage, which indicates that inner elements of double layered thin film objects can be identified using BSE observation of the SEM at appropriate acceleration voltage. 1. Introduction Scanning electron microscopy (SEM) is widely used not only for observation of surface conformation but also for element analysis. Secondary electron (SE) imaging is widely used to observe surface conformation because it reveals nanometer-order structures. For the analysis of sample surface elements, one typical way is to use energy dispersive spectroscopy (EDS). In EDS, the analysis is performed with measurements of characteristic x-rays and quantitative evaluation of components on a surface. However, the lateral resolution is 3 to 8 nm even if low acceleration voltage is used to reduce the noise from the substrate layer under the target samples [1]. Backscattered electron (BSE) is a beam electron that is reflected from the sample by elastic scattering. Because the intensity in BSE images is strongly related to the atomic number of the specimen, BSE images can provide information about the distribution of elements in the sample [2 5]. In a previous study, we found that at least six kinds of thin film elements can be simultaneously discriminated with the contrast greater than 1.3 [6]. The lateral resolution of BSE images depended on the size of the incident electron beam as SE imaging; therefore, BSE measurement is suitable for identifying nano-scale elements such as nano-particle mixtures composed of different elements spread on the substrate. Metal nano-particles are used as labels to Copyright 211 by The Surface Analysis Society of Japan -341-

Journal of Surface Analysis Vol.17, No.3 (211) pp.341-345 visualize biomolecules using SEM [7 9]. In a previous study, we proposed a method to use various metal nano-particles as labels and the particles were observed with high spatial resolution using field emission SEM (FE-SEM) [1]. In this method, various metal nano-particles were produced by covering polystyrene bead surfaces with metals using thermal deposition [11]. We also developed metal nano-shells, which have uniform BSE intensities in comparison with nano-particles, by removing polystyrene beads from the metal nano-particles [12]. For practical use, these nano-shells should be produced as double layers with an inner layer composed of various elements for identification of the label and a gold outer layer to immobilize biomolecules through Au-thiol bonding [13]. In this study, identification conditions of double layered elements were quantitatively evaluated. Evaluations were performed using both thin flat films formed on a silicon (Si) substrate as a model and double layered metal nano-shells as a practical example of biological labels. 2. Materials and methods Preparation of double layered thin flat films Element thin films were formed on a Si substrate using thermal deposition as reported in previous literature [6]. An area of the Si substrate, about 5 mm square, was subdivided into six small areas, and five kinds of metals, Au,,,, and, were deposited on these separate areas, with the thickness of 5 nm. Next, a 2-nm layer of Au was formed on the whole substrate as the second layer. After FE-SEM observations, the thickness of the Au layer was increased to 5 and 1 nm by additional deposition, and FE-SEM measurements were performed at each thickness. Preparation of double layered nano-shells Double layered metal nano-shells were fabricated using the same procedure as previously reported [12]. For fabrication, polystyrene beads (STADEX SC-2-S, SC-3-S and SC-51S, nominal diameter is 196, 39 and 56 nm, respectively, JSR Co., Tokyo) were used as casts of the shells and placed on a Si substrate. and Au metals were sequentially deposited on 2 and 3 nm beads 5 and 5 nm thick, respectively, as the inner and outer layers. For 5 nm beads, Au layers 55 nm thick (i.e., 5 nm inner and 5 nm outer Au layers) were deposited and used as a BSE intensity reference in FE-SEM observation. The metal-deposited nano-particles were set into UV-ozone cleaner (UV253HR, Filgen, Inc., Aichi) and they were UV-ozone oxidized to remove the polystyrene casts. Double layered metal nano-shells ( inner and Au outer layers) were then obtained, dislodged from the Si substrate with an application of gentle ultrasound using a desktop sonicator, suspended in water, and placed again on a clean Si substrate. FE-SEM observation Both thin flat films and fabricated nano-shells were observed with BSE detection mode using an FE-SEM (JSM 671-F, JEOL Ltd., Tokyo) having a BSE detector (SM-7471, JEOL). Observation was carried out under the following conditions: 3 to 3 kv acceleration voltage, magnification of 8 (films) and 8, (nano-shells), 2 pa probe current, 8 mm working distance, 2 sec capture time, 128 124 pixels, and BSE detection mode. Incident electrons were vertically applied to the sample surface and BSE was monitored with its scattered angle range between 16º and 6º from the axis of the incident electron beam. The observation area was set as all elements (Au/Au, /Au, /Au, /Au, /Au, and Si/Au subdivided areas for flat films, and 2 nm /Au, 3 nm /Au and 5 nm Au/Au for nano-shells) were simultaneously captured in a picture. Pictures were taken with maximum contrast using the intensities of Au and Si as the brightest and darkest references, respectively. The acceleration voltage, V, was increased from 3 to 3 kv with a 1 kv step. The emission current was reset immediately before taking pictures to make the capture conditions the same. Data analysis Intensities of elements in BSE images were quantified using an image analysis software (Image J 1.4 g, National Institute of Health, Bethesda, MD, USA, http://rsb.info.nih.gov/ij/). These intensities were digitized as 8-bit gray scale values. As large an area as possible was selected for each element in each picture, and the mean value of the intensity was calculated using the software. This measurement was carried out for all elements in all pictures. To compare intensities of elements, the intensities of Au and Si were used as references of maximum intensity, I max, and minimum intensity, I min, respectively. Relative intensity of an arbitrary element, Ĩ, was calculated using I max, I min, and the measured intensity of the element, I, as in [6] Ĩ (I - I min ) / (I max - I min ) (1) -342-

I I Journal of Surface Analysis Vol.17, No.3 (211) pp.341-345 The Ĩ was calculated for all acceleration voltages of incident electrons, V, and the relationship between Ĩ and V was plotted. 3. Results and discussion BSE observation of double layered thin flat films To evaluate the contribution of the outer thin Au layer to the discrimination of inner elements by BSE measurements using FE-SEM, double layered thin film specimens were fabricated on a Si substrate and the relative intensity, Ĩ, was calculated using Eq. (1) by setting the intensities of Au and Si as 1 and %. Figure 1 shows the relationships between calculated Ĩ and V for Au outer layer thicknesses of 2 (Fig. 1a), 5 (Fig. 1b) and 1 nm (Fig. 1c). The ratio of Ĩ to each element was then calculated to find appropriate conditions to discriminate all elements. The criteria for choosing the appropriate voltage is as follows; the ratio of Ĩ for elements closest to each other in the atomic number should be significantly greater than 1 for every such pair. For example, of, and, has the largest atomic number while has the lowest. Thus, the ratio between Ĩ of and, as well as the ratio between and, both must be significantly larger than 1 for clear identification of all three elements when these elements used to present simultaneously. In the current case where Au,,, and need to be identified, the following ratios of Ĩ, Ĩ (Au)/ Ĩ (), Ĩ ()/ Ĩ (), Ĩ ()/ Ĩ () and Ĩ ()/ Ĩ () should all be significantly greater than the unity. For this specimen, we decided that appropriate condition of V satisfy all of the above ratio to be more than 1.3, because the sample on which second Au layer is absence satisfy this condition [6]. Figure 2 shows the relationships between the ratio of Ĩ among each element and V for Au outer layer thicknesses of 2 (Fig. 2a), 5 (Fig. 2b) and 1 nm (Fig. 2c) calculated with results in Fig.1. The appropriate conditions can be found from Fig.2 as (i) intersection point of / with / and (ii) high values of V, which is 28 kv for 2 nm, more than 26 kv for 5 nm, and more than 27 kv for 1 nm. The objective of this study is discrimination of metal nano-shells conjugated with biomolecules such as mrnas or proteins in a cell, and practical use of high V, i.e. case (ii), is not suitable for this purpose because of serious damages of biomolecules. Therefore, we decided the appropriate condition as case (i) in this study. In Fig.2, the solid lines indicate the appropriate V decided in the above case (i) and the dotted lines indicate the appropriate V when there (Au = 1, Si = ) I (Au = 1, Si = ) (Au = 1, Si = ) 1 9 8 7 6 5 4 3 2 1 1 9 8 7 6 5 4 3 2 1 1 9 8 7 6 5 4 3 2 1 Inner layer: 5 nm Outer Au layer: 2 nm Inner layer: 5 nm Inner layer: 5 nm Outer Au layer: 1 nm Figure 1. Relationship between Ĩ and V for 2 nm, 5 nm, and 1 nm of outer Au layer. is no outer Au layer [6]. The thickness increase of the outer Au layer indicates that the V appropriate to discriminate inner layer elements shifted to a higher value. Values of V appropriate for each thickness of the outer Au layer were 8.8 kv for nm [6], 9. kv for 2 nm, 9.4 kv for 5 nm, and 1.2 kv for 1 nm. The increase of appropriate V was proportional to the thickness of the outer Au layer with its gradient of.143 kv/nm (R 2 >.99). Though the thickness of the outer Au layer increased, the ratio of Ĩ at the appropriate V did not decrease between 1.32 and 1.34, which indicated that we can identify inner elements of double layered thin flat films using BSE observation of FE-SEM by selecting an appropriate V. Identification condition of double layered metal nano-shells Next, we examined whether the results of flat thin films apply to nano-scale objects. For this -343-

Journal of Surface Analysis Vol.17, No.3 (211) pp.341-345 3. 2. 1..5 3. 2. 1..5 3. 2. Inner layer: 5 nm Outer Au layer: 2 nm Au/ / / / Inner layer: 5 nm Au/ / / / Inner layer: 5 nm Outer Au layer: 1 nm nm Au nano-shell, outer layer is apparent, (ii) 3 nm /Au nano-shell, outer layer is apparent, (iii) 3 nm /Au nano-shell, inner layer is apparent, (iv) 2 nm /Au nano-shell, outer layer is apparent, and (v) 2 nm /Au nano-shell, inner layer is apparent, respectively. Orientations of the nano-shells can be identified in the SE image as the absence (i, ii, and iv) or presence (iii and v) of an aperture of the nano-shell. The Ĩ of /Au nano-shells whose inner layer is apparent in the picture (i.e. ii and iv) was calculated for each V and was compared with the result of flat film. Figure 3e shows a summary of the relationships between Ĩ and V for 2-nm nano-shells, 3-nm nano-shells, and flat film. (iii) (iv) (i) (ii) (v) (d) 1. Au/ /.5 / / Figure 2. Relationship between the ratio of Ĩ among each element and V for 2 nm, 5 nm, and 1 nm of outer Au layer. Solid lines indicate the appropriate condition of discrimination for each case and dotted lines indicate that for the absence of outer Au. evaluation, was chosen as a model element and /Au double layered nano-shells were fabricated at thicknesses of 5 nm for as the inner layer and 5 nm for Au as the outer layer. An Au nano-shell 55 nm thick and 5 nm in diameter was also fabricated and used as a maximum intensity reference, I max, in BSE images to calculate Ĩ of /Au nano-shells using Eq. (1). Two different diameters of /Au nano-shells (2 and 3 nm) were fabricated to evaluate the contribution of the size effect for BSE intensity. These two different sized nano-shells were mixed with 5 nm Au nano-shells, and the mixture was dropped on a Si substrate. Figures 3 a to d show both SE (Fig. 3a) and BSE (Figs. 3b d) images of the nano-shell mixture. As indicated in Fig. 3a, five types of nano-shells are observed in these pictures; (i) 5 (e) I / % (f) 1 8 6 4 2 2. 1.8 1.6 1.4 1.2 1..8.6.4.2 Inner layer: 5 nm 2 nm 3 nm Film 3nm/2nm Nano-shell/Film Figure 3. Observations of /Au double layered nano-shells. An SE image of five types of nano-shells (see body text). (b-d) BSE images of nano-shells at 5 kv, 1 kv and 2 kv (d) of V. Bar, 1 µm. (e) Relationships between Ĩ and V for 2 nm /Au nano-shell, 3 nm /Au nano-shell and /Au thin flat film. (f) Relationships between ratios of Ĩ among 2- and 3-nm nano-shells (black) and nano-shell and film (white), and V. -344-

Journal of Surface Analysis Vol.17, No.3 (211) pp.341-345 The ratio of Ĩ between the 3-nm and 2-nm nano-shells were calculated (Fig.3f, black points), and was between.94 and 1.1 for the same V, which indicated that the contribution of the nano-shell diameter to the BSE intensity is within 1% for times difference of the diameter. In a comparison of the BSE intensities of nano-shells with that of flat film, the ratio of Ĩ between an average of 2- and 3-nm nano-shells and the film for the same V was also calculated (Fig.3f, white points) and was.94 to for V from 1 to 2 kv. This indicated that results of thin flat films are applicable to the nano-shell evaluations within an error of 6% in this range of V. The large difference of Ĩ between nano-shell and flat film for low V could be caused by the contribution of element composition of quite surface region for BSE intensity, especially void of the nano-shell which is absent from the film specimen. The difference of Ĩ for high V could be also caused by complicated contribution of Si bulk substrate to the BSE intensity. 4. Conclusion The relationship between Ĩ and V was studied for double layered thin film-like elements with outer layers made of thin Au surfaces that can immobilize biomolecules. Though the thickness of the outer Au layer increased, the ratio of Ĩ among various elements at appropriate V did not decrease for flat film specimens. The difference of Ĩ between nano-shells and flat film for the same V was within 6% for V between 1 and 2 kv. On the basis of these results, we concluded that we could identify the inner elements of double layered thin film-like specimens using BSE observation of FE-SEM with the selection of appropriate V. Acknowledgements We greatly thank Ms. A. Kusano and Ms. M. Murakami for their technical assistance. This work was supported by Kanagawa Academy of Science of Technology. References [1] T. Sakurada, S. Hashimoto, Y. Tsuchiya, S. Tachibana, M. Suzuki and K. Shimizu, J. Surf. Anal. 12, 118 (25). [2] G. Neubert and S. Rogaschewski, Physica Status Solidi A Appl. Res. 59, 35 (198). [3] H. Niedrig, J. Appl. Phys. 53, R15 (1982). [4] G. Neubert and S. Rogaschewski, Physica Status Solidi A Appl. Res. 75, K191 (1983). [5] A. Jablonski, H.S. Hansen, C. Jansson and S. Tougaard, Phys. Rev. B 45, 3694 (1992). [6] H. Kim, T. Negishi, M. Kudo, H. Takei and K. Yasuda, J. Electr. Microsc. doi:1.193/jmicro/ dfq12 (21). [7] T.M. Mayhew and J.M. Lucocq, Histochem. Cell Biol. 13, 299 (28). [8] T.M. Mayhew, Recent Developments. Placenta 3, 565 (29). [9] R. Socher and D. Benayahu, J. Microsc. 23, 233 (28). [1] H. Kim, K. Yasuda and H. Takei, Sens. Actuators B: Chem. 142, 1 (29). [11] H. Takei, J. Vac. Sci. Tech. B 17, 196 (1999). [12] H. Kim, H. Takei and K. Yasuda, Jpn. J. Appl. Phys. 49, 484 (21). [13] H. Kim, H. Takei and K. Yasuda, Jpn. J. Appl. Phys. 49, 871 (21). -345-