Load cell. Special features. Data sheet

Similar documents
Z7A. Load cells. Special features. Data sheet. Wiring code

Single point load cells

TOP Transfer. Data sheet. Force transfer standard. Special features. B en

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

TOP Transfer. Data Sheet. Force transfer standard. Special characteristics. D 20.TOPTRANS.10 en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

TB2. Data Sheet. Torque reference transducer. Special features. B en

Ring-Torsion Load Cells RTB

Benefits/Application. Very high-cycle fatigue resistant up to 100 % of nominal load. Extremely robust against side forces and bending moments

ZF Series Force Transducers

Specifications. Performance. Mechanical Properties. Optional Accessories SR50. Saddle (CA 10B) (Option) Mount Base. LCR-B-5KNS7 to 50KNS7

Benefits/Application. For static and dynamic tensile and compressive forces. Easy assembling, lots of possibilities. Options/Accessories

Benefits/Application. Very high-cycle fatigue resistant up to 80 % of nominal load. Easy assembling, lots of possibilities. Options/Accessories

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

Surface-mounting Thermostats ATH Type Series

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

D a t a s h e e t. F o r c e T r a n s d u c e r. S e r i e s K. ( 4 k N k N ) Benefits/Application. Options/Accessories

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Fitting PS P - B - R2

EX-EMERGENCY LIGHT FITTINGS

Exchangeable measuring insets SensyTemp TSA101

Type UB1 Load Cell. Option Stainless steel cable gland

BSD MODULFLEX R Torsionally Rigid Couplings

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

D a t a s h e e t. T o r q u e s t a n d a r d. S e r i e s D m - T N. ( 1 N m N m ) Benefits/Application. Options/Accessories

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

ED 701 General Industry Pressure Transmitter

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pressure transmitters for industrial applications MBS 32 and MBS 33

Absolute encoders multiturn

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

ATEX/IECEx RTD temperature probe

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Rotary Switches AC09, 16 and 32

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Pressure. 1 Fitting PA R - N R2

Digital AC Motors MHD

variable flow dampers

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

Surface-mounting thermostats Series ATH

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

Ex floating switches and Ex immersion probes

ZF Maschinenantriebe GmbH Industrial Drives. Planetary gearboxes Economy Series for Servomotors

E8EB-N0C2B E8EB-N0B2B

T e c h n i c a l L e x i c o n

Load Washers. Force kn until kn. Type 9101A A

ISEmax CAM40/CAS40. Technical Information

Linear measuring technology

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us

Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Industrial Pressure Transmitter

Industrial Pressure Transmitter

Pressure Measurement Single-range transmitters for general applications

MODEL NAME : LLDMWW0-15K*0*A

Installation Equipment

VK2 volume flow controller Overview

ANNEX to IECEx Certificate

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Field IT 50T Series Transmitters

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

2-way proportional throttle valve for block installation

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

PHOENIX CONTACT - 04/2016. Features

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

TABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic

Valve Products ADEX Series Valves

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

Single Phase Motors Technical Datasheets

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014

LED light engines LED compact. Module DLE G4 ADV Modules DLE

Field mounted Temperature Transmitter TF212/TF212-Ex

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Operating Instructions for Digital Manometer. Model: MAN-SD

Thermal-Magnetic Circuit Breaker 2210-T2...

Strain Gauges and Accessories

LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Cartridge Valves Technical Information. Quick reference

HR-Z SERIES Mild Radiation Resistance LVDT

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Calio-Therm NC Type Series Booklet

Transcription:

Z6 Load cell Special features - Welded on metal bellows - (rated) loads: 5 kg 1 t - Load cells and installation aids made of rust resistant materials - Verifiable up to 6000 divisions, test report as per OIL R60 - Six wire circuit - Optimized for parallel connection - eets requirements as per IN N 45501:2015 - Options: x protection designs as per TX and Ix, F and U ata sheet imensions (in mm; 1 mm = 0.03937 inches) Z6F; (rated) loads 5 kg...500 kg 123 45 18 82 ounting 10 Load application ounting Z6; (rated) load 500 kg (G), 1 t (F) 70 40 210 133 0.1 22 0.1 Load application able, 6-wire, shielded, shield on enclosure etal bellows able, 6-wire, shielded, shield on enclosure 34 13 etal bellows 44 11.1 +0.1 9.9 31 27 15 38 0.1 42 20 20 60 40 25 58 21 23.4 5...200 kg 8.2 8.2 500 kg 10.5 11.1 able 5.4; 3 m long (standard version) 1010-7.1 en : public

Specifications Type Z6(F/G)1 Z6(F/G)3 Z6F3I Z6F4 Z6F6 ccuracy class to OIL R 60 Number of scale intervals (n L ) 1 1000 (rated) load ( max ) kg 5; 10; 20; 30; 50; 100; 200; 500 3 3000 10; 20; 30; 50; 100; 200; 500 3/I7.5 3000 50; 100; 200 4 4000 20; 30; 50; 100; 200; 500 6 6000 20; 30; 50; 100; 200; t 1 1 inimum scale division (v min ) % of max 0.0360 0.0090 0.0083 (30 kg) 0.0066 Return of minimum dead load signal ( R ) 0.5 max / 7500 (rated) sensitivity ( n ) mv/v 2 Sensitivity tolerance with load appl. in spec. direction % +(1; 0.1) 0.05 1) Temperature coefficient of sensitivity (T S ) 2) 0.0500 0.0080 0.0080 0.0070 0.0040 Temperature coefficient of zero signal (TK 0 ) % of n /10 K 0.0500 0.0125 0.0093 0.0093 0.0093 0.016 (30 kg) Relative reversibility error (d hy ) 2) % of n 0.0500 0.0170 0.0066 0.0130 0.0080 Non linearity (d lin ) 2) 0.0500 0.0180 0.0180 0.0150 0.0110 Load creep (d R ) in 30 min. 0.0490 0.0166 0.0098 0.0125 0.0083 Input resistance (R L ) 350...480 Ω Output resistance (R 0 ) 356 0.2 356 0.12 Reference voltage (U ref ) 5 V supply voltage range ( u ) 0.5...12 Insulation resistance (R is ) GΩ 5 ambient temperature range ( T ) Operating temperature range ( tu ) Storage temperature range ( tl ) Limit load ( L ) reaking load ( d ) o 10...+40 30...+70 50...+85 % of max 150 (rated) load kg 5 10 20 30 50 100 200 500 1000 Relative permissible oscillatory stress % of max 100 100 100 100 100 100 100 70 100 (rated) displacement (s nom ) approx. mm 0.24 0.3 0.29 0.28 0.27 0.31 0.39 0.6 0.55 Weight, (G) approx. kg 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 2.3 egree of protection (IP) as per N60529 IP 68 (tougher test conditions: 1 m water column; 100 h ) (I529) aterial: easuring body ellows able inlet gland able sheath Stainless steel 3) Stainless steel 3) Stainless steel / Viton PV 1) For load cell Z6F3/10kg: 0.1 %. 2) The values for linearity deviation, relative reversibility error and temperature effect on sensitivity are typical values. The sum of these values is within the cumulative error limits laid down by OIL R60. 3) s per N 10088-1 300 2 1010-7.1 en : public

able assignment (6-wire configuration) With this cable assignment, the output voltage at the measuring amplifier is positive when the transducer is loaded. (gray) (black) (white) (blue) (green) (red) (stranded wire) Sense lead ( ) xcitation voltage ( ) easurement signal (+) xcitation voltage (+) Sense lead (+) easurement signal ( ) able shield connected to enclosure ground Installation aids, not included in scope of delivery (imensions (in mm; 1 mm = 0.03937 inches)) Note: ll installation aids are made of non-rusting material. The rubber parts of the ZL are made of chloroprene rubber. Oscillating loading foot ZFP for nominal (rated) loads 5 kg...200 kg eight adjustable 69... 75 Steel 50 60 irection of load Rubber Z6/ZFP/200kg Knuckle eye ZGWR (maintenance-free) for nominal (rated) loads 5 kg...1 t Screw and washer are included in the scope of delivery Z6/.../ZGWR W N F K J L G SW 2 Force feedback ZRR for nominal (rated) loads 5 kg... 200 kg 1 F 1 1 G 2 F2 w G1 1 a Z6/200kg/ZRR (rated) load ZGWR F G J K L SW W N 5...200 kg Z6/200kg/ZGWR 16 8 7 24 36 48 9 12.5 16 5 8 14 12 46 500 kg Z6/1t/ZGWR 20 10 7 28 43 57 10.5 15 19 6.5 10 17 14 53 1 t Z6/1t/ZGWR 20 10 7 28 43 57 10.5 15 19 6.5 10 17 14 55.5 ZRR 1 2 F 1 F 2 G 1 G 2 1 a w epth (rated) load 5...200 kg Z6/200kg/ZRR 16 30 30 65 85 46 77 8 8x30 80 1.1 123 15 1010-7.1 en : public 3

Oscillating loading foot ZKP for nominal (rated) loads 5 kg...200 kg 8 Z6/.../ZKP ø25 ø25 77...82 one, conical pan ZK for nominal (rated) loads 5 kg...1 t 16 64...69 F19 SW13* * Tightening torque: 30 N m onical pan 90 one 60 U X Z6/.../ZK ø80 (rated) load one, conical pan ZK U X 5...200 kg Z6/200kg/ZK 15 16 21 8.1 0.05 26 500 kg Z6/1t/ZK 18 24 32 11 0.05 34 1 t Z6/1t/ZK 18 24 32 11 0.05 36.5 Oscillating loading foot PX for nominal (rated) loads 5 kg... 500 kg (Z6/PX/500kg); 1 set comprising 4 pieces Z6/PX/500kg Spacer ngle: max. 5 69... 75 64... 70 Pos. 1, F13 Pos. 2, F17 Pos. 3, F17 F = cross Flats 10 Ø50 Ø60 ase plate / ounting set for nominal (rated) loads 5 kg (Z6/ZPU/200kg)... 500 kg (Z6/ZPU/500kg) Load application (Z6/...kg/ZPL; Z6/...kg/ZL ; Z6/...kg/ZK) View from below * 100 65 79 82 0.1 Gap 15 31 66 14 * Tightening torque : 23 N m (200 kg) ; 45 N m (500 kg) Gap : In a load cell loaded with the nominal (rated) load, there should be a gap width 0.05 mm 155 200 22.5 4 1010-7.1 en : public

Pendulum bearing ZPL for nominal (rated) loads 5 kg...1 t T F U O Z6/200kg/ZPL Z6/500kg/ZPL Z17/2t/ZPL (for 500 kg, large and 1 t nominal (rated) load 2 dust protection rings included in ZPL scope of delivery Fastening screw included in ZPL scope of delivery (rated) load Pendulum bearing ZPL O T F U F * R (% of the load) 5...200 kg Z6/200kg/ZPL 20 0.2 45 89 +0.6-0.8 8 30 6.5 17 9 20 10 2.8 3.5 500 kg Z6/500kg/ZPL 20 0.2 45 89 +0.6-0.8 8 30 6.5 17 9 20 10 2.8 3.5 1 t Z17/2t/ZPL 30 0.1 60 126.5 10 46 8 22 14 30 10 2 7.5 * F R : Force feedback in N, with 1 mm lateral displacement ** s max : aximum perm. lat. displacement with nominal (rated) loading s max ** (mm) Rubber-metal bearing ZL for nominal (rated) loads 5 kg...200 kg For nominal (rated) loads 1 t L Z6/1t/ZL F G Z6/200kg/ZL For nominal (rated) load 500 t K F Screws offset by 35 N L Z6/1t/ZL F P R orrect installation position of the rubber-metal bearing (rated) load ZL F G K L N P R F R * s max ** 5...200 kg Z6/200kg/ZL 75 12 12 40 79 1.3 18.5 8 SW17 19 163 3 500 kg Z6/1t/ZL 80 10 10 39 +2.1 105 26 SW27 20 120 100 9 60 400 4.5 2.2 1 t Z6/1t/ZL 80 10 10 39 117 +2.1-2.2 * F R : Force feedback in N, with 1 mm lateral displacement ** s max : in mm, aximum perm. lat. displacement with nominal (rated) loading 26 SW27 20 120 100 9 60 400 4.5 1010-7.1 en : public 5

Z6 Load cells, versions and options Order no. K-Z6 ode Option 1: esign F Z6F G Z6G (big) [only with Option 2 = 3 + Option 3 = 500] ode Option 2: ccuracy 1 1 (OIL) [not with Option 1 = G] 3 3 (OIL) 4 4 (OIL) [only with Option 3 = 20 / 30 / 50 / 100 / 200 / 500 + Option 5 = S3] 6 6 (OIL) [only with Option 3 = 20 / 30 / 50 / 100 / 200 / 500 + Option 5 = S3] ode Option 3: apacity 5 5 kg [only with Option 2 = 1] 10 10 kg [only with Option 2 = 1 / 3] 20 20 kg 30 30 kg [only with Option 4 = N/(I2/21)] 50 50 kg 100 100 kg 200 200 kg 500 500 kg [only with Option 2 = 1 / 3 / 4] 1000 1 t [only with Option 2 = 1 / 3] ode Option 4: x protection N No x protection I1/21 Ix-TX zone 1/21 and F I2/21 Ix-TX zone 2/21 R1/21 U zone 1/21 R2/21 U zone 2/21 ode Option 5: able length S3 3 m (standard) 6 6 m [not with Option 2 = 6] 12 12 m [not with Option 2 = 6] ode Option 6: iscellaneous N Without K-Z6 - - - - - - N Options x protection versions per Ix, TX and F I1/21 Ix+TX zone 1/21 + F intrinsically safe, II 2G x ia II T6/T4 Gb, II 2 x ia III T125 b* I2/21** Ix+TX zone 2/21 not intrinsically safe, II 3G x n II T6/T4 Gc, II 2 x tb III T125 b* * with U type examination certificate (VS13TX 108 X) and Ix ertificate of onformity (Ix VS 13.0109 X) ** Ix zone 2/21 includes option TX2/22 and also offers the additional customer benefit of usage with conductive dust as well. x protection versions per (urasian economic union with the member states: Russia, elarus, rmenia, Kazakhstan, Kyrgyzstan) R1/21 U zone 1/21 TR ZU 012/2011 x certificate, 1 x ia II T6/T4 Gb X / x ia III T125 b X*** R2/21 U zone 2/21 TR ZU 012/2011 x certificate, 2 x ia II T6/T4 Gc X / x tb III T125 b X*** *** with certificate СЕРТИФИКАТ СООТВЕТСТВИЯ ТС RU -.ГБ08.В.01138 Subject to modifications. ll product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure and predict with confidence 6 ottinger aldwin esstechnik Gmb Im Tiefen See 45 64293 armstadt Germany Tel. +49 6151 803 0 Fax +49 6151 803 9100 mail: info@hbm.com www.hbm.com 1010-7.1 en : public 1010-7.1 en : public