William E. Barber, Ph.D. Applications Chemist October

Similar documents
Choosing Columns and Conditions for the Best Peak Shape

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

LC and LC/MS Column Selection Flow Chart

A Look at Column Choices. Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009

Tips and Tricks of HPLC System Troubleshooting

Advanced Topic: Tips and Tricks of HPLC Separations and Troubleshooting. Rita Steed LC Advanced Topics Seminar Series August 25, 2010.

Too Polar for Reversed Phase What Do You Do?

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HPLC Column Troubleshooting

HPLC Column Troubleshooting: Is It Really The Column? LC Columns and Consumables. Robyn C. Woolley Online Application Engineer July 24, 2007.

Eliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput

Hypersil BDS Columns TG 01-05

HPLC Method Development: Standard Practices and New Columns

Tips and Tricks of Faster LC Analysis Without Capital Investment It may be easier than you think!

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Validated HPLC Methods

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC

Reversed Phase Solvents

Regis Technologies Ion Pair Reagents and Buffers

Does one-size-fit-all?

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS

Inertsil ODS-EP Technical Information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

State-of-the-art C18 HPLC Columns

HPLC Separation Robustness and Ruggedness Assessing the Effects of Experimental Variables During Method Development

New Product Update. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

Alltech Alltima HP Introduction

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

ACE Ultra Inert Base Deactivated HPLC Columns

Packings for HPLC. Packings for HPLC

How proteins separate on reverse-phase HPLC

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC

HPLC Method Development: Standard Practices and New Columns. Agilent Technologies February 2007

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Silanol. Groups Liquid Chromatography

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Shodex TM ODP2 HP series columns

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

for Acclaim Mixed-Mode HILIC-1 Column

mau 200 ph min

Comparison Guide to C18 Reversed Phase HPLC Columns

A Look at Agilent HPLC Columns Choices

HPLC Column Classification

Acclaim Mixed-Mode WCX-1

High Resolution Fast LC

ProntoSIL HPLC Columns

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

for Acclaim Mixed-Mode WCX-1

Reversed Phase Chromatography: Mobile phase Considerations

Optimisil HPLC & UPLC Column catalogue

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

General Principles of HPLC Method Development

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

A C18 Silica Column With Exceptional Temperature and ph Stability

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

8. Methods in Developing Mobile Phase Condition for C18 Column

High Performance Liquid Chromatography

High Performance Liquid Chromatography

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion

Bringing uhplc Performance to the Separation of Peptides

RP C18 column with feature of a silanol group

Technical Guide Thermo Scientific Syncronis HPLC Columns

Fluophase and Fluofix Columns

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Comparison of different aqueous mobile phase HPLC techniques

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Method Development Kits

Analysis - HPLC A.136. Primesep 5 µm columns B.136

State - of - the -art C18 HPLC Columns

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Overview Applications of NUCLEODUR HPLC Phases

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

InertSustainSwift C8

HPLC UHPLC Columns. Dikma Technologies Inc.

UPLC Method Development and Validation

LC Technical Information

Ronald E. Majors, Ph.D. Product Marketing Specialist Consumables and Accessories Business Unit May 31, 2000

Part 2. Overview of HPLC Media

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Transcription:

William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis

The Secrets of Good Peak Shape in HPLC - Choosing Columns and Conditions for the best peak shape Presented by Dr. Bill Barber Applications Chemist

What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include both peak fronting and tailing. Good peak shape can be defined by. Tailing factor of.0 High efficiency Narrow peak width Good peak shape is important for. Improved resolution (Rs) More accurate quantitation Longer usable column lifetime (based on system suitability criteria) Slide

How is Peak Shape Measured? Measures USP Tailing Factor at 5% of peak height* Asymmetry at 0% of peak height Indicators Efficiency plates* Peak Width peak width at ½ height* * Available in ChemStation reports Slide 4

How is Peak Shape Measured? USP Tailing Factor Efficiency Peak Front Peak Tail h N = 5.54 ( t R ) W ½ h f W 0. 0 5 0.05 h Peak Maximum T f = W 0.05 /f Asymmetry Peak Width at ½ Height Peak Front Peak Tail h h W h / h/ W 0. a b 0. h W t Peak Maximum A s = b/a Slide 5

Factors Affecting Peak Shape Column packing factors Silica type Bonded phase and endcapping Mobile phase factors Sample factors Slide 6

Column Factors Affecting Peak Shape Silica type/acidity Fully hydroxylated silica and silica metal content Silica silanol ionization* Hydrogen bonding with silica silanols* Column bonding Endcapping Type of bonded phase Packing Pore Size/Structure *Controlled by mobile phase Slide 7

Silica Type - Fully Hydroxylated and Metal Free Silica Reduces Acidity H H H H H Si Si Si Si Free Silanols Geminol Silanols Associated Silanols decreasing acidity M + M + Surface Metal H Si Internal Metal (activated silanol) (most acidic) Slide 8

High Purity, Low Acidity Silica Improves Peak Shape Mobile Phase: 5% -Propanol in Heptane Flow Rate:.0 ml/min.temperature: 5 C Standard Silica High Purity, Low Acidity ZRBAX Rx-SIL CH -H NH CH CH NH CH CH CH -H Improve peak shape for basic compounds with high purity, fully hydroxylated silica such as Rx-SIL Slide 9

ZRBAX StableBond with Rx-SIL Improves Peak Shape Mobile Phase: 75% 50 mm KH P 4, ph 4.4 : 5% ACN Flow Rate:.5 ml/min Silica Type More Acidic Column: DS, 4.6 x 50 mm, 5 µm Plates: 9 USP T f (5%):.90 Silica Type High Purity, Rx-Sil Column: SB-C8, 4.6 x 50 mm, 5 µm Plates: 67 USP T f (5%):.09 Propranolol pka 9.5 H CHCHCHNHCH(CH) 0 5 0 5 0 5 0 The high purity Rx-SIL improves the peak shape dramatically on a C8 column Slide 0

Potential Ion Exchange and Hydrogen Bonding Secondary Interactions Ion-exchange Si _ Na+ + R NH + Si _ N + R + Na +. Ionized silanols (Si - ) will ion-exchange with protonated bases (R NH + ) which can cause tailing and method variability. This occurs most often at mid ph where silanols are ionized. Hydrogen Bonding -SiH + RC _ -Si _... H +... _ CR. Unprotonated acids can compete for H + with protonated silanols. This can occur at low ph. Some mobile phase additives can be added to the mobile phase to reduce these interactions and this will be discussed in the mobile phase section. Slide

Bonded Phase Types for Better Peak Shape Bonded phases with endcapping Eclipse XDB columns are double endcapped This minimizes the number of unreacted silanols and potential peak tailing interactions Bonded phases with embedded polar groups Bonus-RP provides unique silanol shielding reducing peak tailing for basic compounds Bonded phases for high ph Extend-C8 is stable at high ph Basic compounds can not ion-exchange with the silica thereby reducing peak tailing Bonded phases for high aqueous SB-Aq is more wettable improving analyte interactions and peak shape Slide

Eclipse XDB is Double Endcapped for Best Peak Shape Improved peak shape for basic compounds especially at intermediate ph Double endcapped with two different reagents for more complete silanol coverage CH Si CH CH CH CH Si Si CH Good for all sample types acid, base, neutral Wide useable ph range ph -9 CH CH Si CH CH Si CH CH Slide

Double Endcapping Improves Peak Shape ph 7 Columns: 4.6 x50 mm, 5 µm Mobile Phase: 60% ACN : 40% 0 mm phosphate buffer ph 7.0 Flow Rate:.5 ml/min. Temperature: 40 C Sample:. Nortriptyline pka 9.7. Doxepin pka 9.0. Amitriptyline pka 9.4 4. Trimipramine Single Endcapped Competitive WS C8 Double Endcapped Eclipse XDB-C8 Tf..95..90..54 4.. 4 Tf..79..4..4 4..0 4 0 4 5 6 7 8 0 4 5 6 7 8 Each column is made from high purity silica Fewer silanol interactions on the double endcapped column reduce tailing and retention Slide 4

Double Endcapping Provides Superior Peak Shape Eclipse XDB-C8 vs. Competitive C8 Columns: 4.6 x 50 mm, 5 µm Mobile Phase: 50% 5 mm Na HP 4, ph 7.: 50% MeH Detection: UV 54 nm Flow Rate:.0 ml/min Temperature: 5 C Sample:. Uracil. Amlodipine. Benazepril Competitive L C8 Eclipse XDB-C8 Tf(5%)..07..50 Tf(5%)..0..08 0 4 6 8 0 4 0 4 6 8 0 4 Eclipse XDB shows superior peak shape for the basic compound, benazepril. Slide 5

Bonus-RP with Embedded Polar Groups R Good peak shape for basic compounds CH Si R PG R Polar alkyl-amide bonded phase Si CH CH R Unique selectivity Si PG R Enhanced low ph stability with sterically protecting bonding R CH Si CH Triple endcapped CH R Si PG R R Slide 6

Polar Alkyl Amide Bonded Phase Provides Better Peak Shape than Traditional Alkyl Phase Columns: 4.6 x 50 mm Mobile phase: 5 mm K HP 4, ph 7. / (MeH: ACN, 50:50), 45/5 Flow rate: ml/min. Detection: UV 54 nm Injection vol: 5 µl Sample: Anorectics ( Fen-phen ). Phentermine pka0.. Fenfluramine pka 9.. Impurity mau 5 0 Bonus-RP 5 0 mau 5 0 5 Alkyl C8 0 0 4 5 6 7 min Good peak shape of highly basic compounds is readily achieved on Bonus-RP. 00767S.PPT Slide 7

ZRBAX Extend-C8 for High ph Superior high ph stability up to ph.5 with silica particles Si C8 Excellent reproducibility Si C8 Patented bidentate, C8 bonding Si C8 Double endcapping Si C8 Slide 8

Extend-C8 Improves Retention and Peak Shape of Basic Compounds at High ph Column: ZRBAX Extend-C8, 4.6 x 50 mm, 5 µm Mobile Phase: 0% buffer: 70% MeH ph 7 buffer=0 mm Na HP ph buffer = 0 mm TEA 4 Flow Rate:.0 ml/min Temperature: RT Detection: UV 54 nm Sample:. Maleate. Scopolamine pka 7.6. Pseudoephedrine pka 9.8 4. Doxylamine pka 9. 5. Chlorpheniramine pka 9. 6. Triprolidine pka 6.5 7. Diphenhydramine pka 9.0 Extend-C8 ph 7 4, 7 Extend-C8 ph t R = 8.5 t R =.4 4 7 5 5 6 6 0 5 0 5 0 The retention of this sample of basic compounds increases at high ph on Extend-C8. Slide 9

ZRBAX SB-Aq for Good Retention and Peak Shape in High Aqueous Mobile Phases Bonded phases that are more wettable in high aqueous mobile phases improve chromatography both peak shape and retention reproducibility. A wettable bonded phase is one that does not fold over or collapse in a high aqueous mobile phase. These types of bonded phases can have polar endcapping or polar groups in the bonded phase, or other modifications to increase polarity. The SB-Aq column is an alkyl chain with more polar character that a typical C8 column. Slide 0

Inconsistent Retention in High Aqueous Mobile Phase with Typical C8/C8 Columns Example: Procainamides on Hydrophobic-C8 Column Equilibrate with 50% ACN, then mobile phase Column: Eclipse XDB-C8 4.6 x 50 mm Mobile Phase: 90% 50 mm KH P 4, ph.5 0% ACN Flow Rate:.0 ml/min Temperature: RT Sample:. Uracil. Procainamide. N-acetylprocainamide 4. N-propionylprocainamide 5. Caffeine Phase Collapse 50% loss in Resolution After equilibrating with 00% buffer Increase in peak tailing 4 5 4 5 0 5 0 0 5 0 Slide

Consistent Retention of Procainamides on SB-Aq with Good Peak Shape Equilibrate with 50% ACN, then mobile phase Column: ZRBAX SB-Aq 4.6 x 50 mm, 5 µm Mobile Phase: 90% 50 mm KH P 4, ph.5 0% ACN Flow Rate:.0 ml/min Temperature: RT Detection: UV 54 nm, 4 nm Sample:. Uracil. Procainamide. N-acetylprocainamide 4. N-propionylprocainamide 5. Caffeine 4 No Phase Collapse No loss in Resolution After equilibrating with 00% buffer Good peak shape on all peaks 4 5 5 0 5 0 5 min 0 5 0 5 min The SB-Aq column provides both good and consistent retention of the procainamides. Slide

ZRBAX SB-Aq Provides Good Retention and Peaks Shape of Polar Pharmaceutical Compounds Columns: Zorbax SB-Aq, 4.6 x 50 mm, 5 µm Mobile Phase: 90% 0.% TFA 0% ACN Temperature: 5 C Flow Rate:.5 ml/min. Detection: UV 54 nm 4 Sample: 5. Maleate. Phenylephrine. Phenylpropanolamine 4. Pyrilamine 5. Chlorpheniramine 0 4 6 8 0 4 6 These small polar compounds are difficult to retain on most columns. The SB-Aq provides excellent retention with a 90% aqueous mobile phase. Slide

Break Number Please type your question into the Chat Box at any time during the presentation. Slide 4

Large Molecules Need Large Pore Sizes for Good Peak Shape Wide-pore 00Å totally porous columns can be selected for efficient peaks when separating proteins and peptides. Select wide-pore columns for lower molecular weight molecules with large hydrodynamic volumes. Select Poroshell columns for more rapid mass transfer and improved efficiency of large peptides and proteins at higher flow rates. Slide 5

Choose 00Å Columns for Good Peak Shape with Peptides and Proteins Effect of Pore Size and Molecular Size on Peak Width, Gradient Separations 0. 0.8 0.6 00SB-C8 (00Å) SB-C8 (80Å) 0.4 PW / 0. 0. 0.08 0.06 0.04 0.0 0 Leu Enkephalin M.W. = 556 Angiotensin II M.W. = 046 Insulin B M.W. =,496 Cyt C M.W. =,7 RNase M.W. =,684 Lysozyme M.W. =,900 Proper pore size selection results in sharper peaks for large molecules Slide 6

Improved Peak Shape for Large Molecules in Solution with 00Å Columns Columns: 4.6 x 50 mm, 5 µm Mobile Phase: 60% MeH: 40% 0.% TFA Flow Rate: 0.75 ml/min Temperature: RT Detection: UV 8 nm Sample: Tylosin (MW 96) SB-C (80Å) H CH CH H C CH CH CH CH H C CH CH CH H H C H N CH CH 00SB-C (00Å) H CH H CH Pw / = 0.44 Pw / =0.5 0 5 0 0 5 0 The size of a molecule in solution determines which pore size column is best. The narrower peak width indicates unrestricted access to the pores. Slide 7

Mobile Phase Factors for Improved Peak Shape ph Buffers rganic modifiers Additional mobile phase modifiers (TEA, TFA) Slide 8

Good Peak Shape at Low ph ph 7.0 USP TF( 5%) 4..5 ph.0 USP TF (5%) 4.. Column: ZRBAX Eclipse XDB-C8 4.6 x 50 mm, 5 µm 4 5 4 5 Mobile Phase:85% 5 mm Na HP 4 5% ACN Flow Rate:.0 ml/min. Temperature: 5 C Sample: Amphetamines. Phenylpropanolamine pka 9.4. Ephedrine pka 9.6. Amphetamine pka 9.9 4. Methamphetamine pka 0. 5. Phentermine pka 0. 0.0.5 5.0 0.5 5.0 These basic compounds have good peak shape when the ph is lowered and the silica silanols are protonated. Slide 9

Effect of ph on Peak Shape at or Near the Sample pka Column: ZRBAX SB-C8 4.6 x 50 mm, 5 µm Mobile Phase: 40% 5 mm KH P 4 : 60% ACN Flow Rate:.0 ml/min. Temperature: RT ph 4.4 ph.0 CH CHCH CH CH(CH ) Ibuprofen pk a = 4.4 0 4 5 6 7 8 9 0 0 4 5 6 7 8 9 0 Inconsistent and tailing peaks may occur when operating close to an analyte pka and should be avoided. Slide 0

Use Buffered Mobile Phases for Best Peak Shape and Retention Column: ZRBAX Rapid Resolution Eclipse XDB-C8, 4.6 x 75 mm,.5 µm Mobile Phase: 44% A : 56% methanol Flow Rate:.0 ml/min Temperature: 5 C Detection: UV 50 nm Sample:. ketoprofen. ethyl paraben. hydrocortisone pka 5. 4. Fenoprofen pka 4.5 5. propyl paraben 6. Propranolol pka 9.5 7. Ibuprofen pka 4.4 A = ph 7.0 water A = ph 7.0, 5 mm phosphate buffer, 4, 6, 7 4 5 5 6 7 0 4 0 4 5 Buffered mobile phases enhance retention, resolution, and peak shape. Slide

Increasing Buffer Concentration Decreases Tf 0 mm Phosphate ph 7.0 4 5 USP Tf..6..65..6 4..77 5..8 6.. 6 5 mm Phosphate ph 7.0 USP Tf..4..50.. 4..9 5..6 6..00 4 5 Columns: ZRBAX Eclipse XDB-C8 4.6 x 50 mm, 5 µm Mobile Phase:40% phoshpate buffer 60% ACN Flow Rate:.5 ml/min. Temperature: 40 C Sample: Tricyclic Antidepressants. Desipramine. Nortriptyline. Doxepin 4. Imipramine 6 5. Amitriptyline 6. Trimipramine 0.5 5.0 7.5 0.5 5.0 Higher ionic strength at mid ph is very effective at masking silanol interactions and reducing peak tailing. Slide

Mobile Phase rganic Modifier Acetonitrile vs. Methanol 40% 5 mm Na HP 4 ph 7.0 60% ACN 40% 5 mm Na HP 4 ph 7.0 60% MeH 4 5 USP TF 5%....9..66 4..94 5..95 6.. USP TF 5%. 0.7..45..4 4..5 5..09 6..0 Columns: ZRBAX Eclipse XDB-C8 4.6 x 50 mm, 5 µm Flow Rate:.5 ml/min. Temperature: 40 C Sample: Tricyclic Antidepressants. Desipramine. Nortriptyline. Doxepin 4. Imipramine 5. Amitriptyline 6. Trimipramine 6 4 5 6 0.5 5.0 7.5 0 5 50 Changing the organic modifier may improve peak shape due to secondary interactions. Slide

Mobile Phase Modifiers Effect of TEA on Peak Shape of Basic Compounds Column: ZRBAX Eclipse XDB-C8, 4.6 x 50 mm, 5 µm Mobile Phase: 85% 5 mm Na HP 4 : 5% ACN Flow Rate:.0 ml/min. Temperature:5 C Sample: Amphetamines. Phenylpropanolamine. Ephedrine. Amphetamine 4. Methamphetamine 5. Phenteramine ph 7 No TEA 0 mm TEA 4 5 USP TF 5%..9....6 4..5 5..57 4 5 USP TF 5%..9..8..0 4..6 5..4 0.0.5 5.0 0.5 5.0 Slide 4

Mobile Phase Modifiers Effects of Competing Acids on the Peak Shape of Acidic Compounds A: ph 5 mm NaH P 4 ph 5 mm NaH P 4 % acetic acid ph.5 0.% TFA Column: ZRBAX StableBond SB-C8 4.6 x 50 mm, 5 µm Mobile Phase: 40% A: 60% ACN Flow Rate:.0 ml/min. Temperature: Room Temperature Sample: Ibuprofen pka 4.4 T f =.8 T f =.0 T f =.09 Both acetic acid and TFA (trifluoroacetic acid) act as competing acids. TFA can be used at a lower concentration and is the preferred choice. Slide 5

Break Number Please type your question into the Chat Box at any time during the presentation. Slide 6

Sample and Additional Considerations for Good Peak Shape Sample overload (mass/volume) Sample solvent/injection solvent Metal complexation Slide 7

Sample verload May Cause Peak Fronting and Tailing Peak fronting from sample mass overload more sample than can effectively partition results in some sample preceding the rest of the peak Peak tailing from overload of silanols with basic compounds may be seen as peak tailing Reduce sample load to eliminate 00 mau for compounds with average absorptivity Slide 8

Strong Injection Solvent May Cause Poor Peak Shape Column: ZRBAX StableBond SB-C8, 4.6 x 50 mm, 5 µm Mobile Phase: 8% H : 8% ACN Injection Volume: 0 µl Sample:. Caffeine. Salicylamide A. Injection Solvent 00% Acetonitrile B. Injection Solvent Mobile Phase 0 0 0 0 Injecting in a solvent stronger than the mobile phase can cause peak shape problems, such as peak splitting or broadening. Slide 9

Metal Complexation May Cause Poor Peak Shape Analytes that may complex with metals may show poor peak shape Both tailing and fronting may result from metal complexation Metals are present in LC systems from solvents, tubing, and stainless steel frits High purity silica eliminates silica as a source of metals Slide 40

Metal Sensitive Compounds Can Chelate Hint: Look for Lone Pair of Electrons on :: or N Which Can Form 5 or 6 Membered Ring with Metal : C : H : H C M + H + M + : : H Salicylaldehyde 6-membered ring complex N: M + H : : C C : : N : H M + 8-hydroxyquinoline 5-membered ring complex a-benzoinoxomine 5-membered ring complex Slide 4

Acid Wash Can Improve Peak Shape Before Acid Wash After Acid Wash 50 00 mls % H P 4 H H H H H.... H H H Columns: ZRBAX SB-Phenyl 4.6 x 50 mm Mobile Phase: 75% 5 mm ammonium phosphate buffer 5% ACN Flow Rate:.0 ml/min. Temperature: RT Sample Size: 5 µl Tf:.7 Tf:. A % H P 4 solution is used on SB columns, 0.5 % can be used on endcapped columns. Slide 4

Purpurin Column: Zorbax SB-C8, 4.6 x 50 mm, 5 µm Mobile Phase: 0% 0.0% TFA in water: 80% MeH Flow Rate: ml/min Detection: UV 54 nm Temperature: 4 C A. Before Acid Wash B. After Acid Wash % phosphoric acid, 0 min. Purpurin H H H Tf=.6 Tf=.8 0 4 5 6 0 4 5 6 Both fronting and tailing are evident on purpurin before the acid wash Slide 4

Guidelines for Improved Peak Shape Select columns based on high purity fully hydroxylated silica Zorbax Rx-Sil based columns, such as StableBond, Eclipse XDB, Bonus-RP and Extend Select double endcapped columns for mid ph or difficult basic compounds, such as Eclipse XDB Select special bonded phases (Bonus-RP, Extend-C8) for better peak shape at mid and high ph Select wide-pore columns for high molecular weight analytes Use buffered low ph mobile phases to reduce secondary interactions Use 5 50 mm buffered mobile phases at every ph Use additional additives only when needed Check sample solvents Slide 44

Wrap-up E-Seminar Questions Thank you for attending Agilent e-seminars. ur e-seminar schedule is expanding every week. Please check our website frequently at: www.agilent.com r register for Stay current with e-notes to receive regular updates Slide 45