SCANNING THERMAL MICROSCOPY OF THERMOELECTRIC PULSED LASER DEPOSITED NANOSTRUCTURES

Similar documents
Properties of Thermoelectric Nanocomposite Bi 2 Te 3 Layers Prepared by PLD

Thermal measurements using Scanning Thermal Microscopy (SThM) Micro and Nanoscale measurements

Instrumentation and Operation

Electrical Characterization with SPM Application Modules

Supplementary Information. Characterization of nanoscale temperature fields during electromigration of nanowires

Scanning Probe Microscopy. Amanda MacMillan, Emmy Gebremichael, & John Shamblin Chem 243: Instrumental Analysis Dr. Robert Corn March 10, 2010

CNPEM Laboratório de Ciência de Superfícies

SUPPLEMENTARY NOTES Supplementary Note 1: Fabrication of Scanning Thermal Microscopy Probes

1. Fabrication. Lukáš Ondič a, Marian Varga a, Karel Hruška a, Jan Fait a,b and Peter Kapusta c

Nitride HFETs applications: Conductance DLTS

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

A STRUCTURE AND DIELECTRIC PROPERTIES OF POLYMER NANOCOMPOSITES ON THE BASE OF ISOTACTIC POLYPROPYLENE AND LEAD SULPHIDE NANOPARTICLES

Supplementary Information for. Effect of Ag nanoparticle concentration on the electrical and

Scanning Probe Microscopy (SPM)

Lecture 4 Scanning Probe Microscopy (SPM)

Supplementary Figures

MS482 Materials Characterization ( 재료분석 ) Lecture Note 11: Scanning Probe Microscopy. Byungha Shin Dept. of MSE, KAIST

AP5301/ Name the major parts of an optical microscope and state their functions.

Nanoelectronic Thermoelectric Energy Generation

General concept and defining characteristics of AFM. Dina Kudasheva Advisor: Prof. Mary K. Cowman

Structure-Thermal Property Correlation of Aligned Silicon. Dioxide Nanorod Arrays

Piezoresistive effect in p-type 3C-SiC at high temperatures characterized using Joule heating

Transformation dependence of lead zirconate titanate (PZT) as shown by PiezoAFM surface mapping of Sol-gel produced PZT on various substrates.

Heat transfer in ultrahigh vacuum scanning thermal microscopy

Research to Improve Photovoltaic (PV) Cell Efficiency by Hybrid Combination of PV and Thermoelectric Cell Elements.

Lecture 6. Alternative storage technologies. All optical recording. Racetrack memory. Topological kink solitons. Flash memory. Holographic memory

Supplementary Information for On-chip cooling by superlattice based thin-film thermoelectrics

Supporting Information for

CHARACTERIZATION of NANOMATERIALS KHP

MODELING OF JOULE HEATING AND THERMOELECTRIC TRANSPORT IN THIN FILM SILICON FOR SJEM MEASUREMENT YOUNGJOON KOH THESIS

Segmented Power Generator Modules of Bi 2 Te 3 and ErAs:InGaAlAs Embedded with ErAs Nanoparticles

Final Reading Assignment: Travels to the Nanoworld: pages pages pages

Graphene films on silicon carbide (SiC) wafers supplied by Nitride Crystals, Inc.

nano-ta: Nano Thermal Analysis

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Dopant Concentration Measurements by Scanning Force Microscopy

Application of electrostatic force microscopy in nanosystem diagnostics

Micromachined Chip Scale Thermal Sensor. for Thermal Imaging

ABSTRACT 1. INTRODUCTION 2. EXPERIMENT

Infrastructure of Thin Films Laboratory in Institute of Molecular Physics Polish Academy of Sciences

Newcastle University eprints

Supplementary Information. Large Scale Graphene Production by RF-cCVD Method

Transient Through-Silicon Hotspot Imaging

MS482 Materials Characterization ( 재료분석 ) Lecture Note 12: Summary. Byungha Shin Dept. of MSE, KAIST

Thermal conductivity calibration for hot wire based dc scanning thermal microscopy

Other SPM Techniques. Scanning Probe Microscopy HT10

STUDY OF LAYERS OF METAL NANOPARTICLES ON SEMICONDUCTOR WAFERS FOR HYDROGEN DETECTION

IR LASER-INDUCED CARBOTHERMAL REDUCTION OF TITANIUM MONOXIDE: CARBON- PHASE SHIELD TO NANOSIZED TiO OXIDATION

Magnetic Force Microscopy (MFM) F = µ o (m )H

SOLID STATE PHYSICS PHY F341. Dr. Manjuladevi.V Associate Professor Department of Physics BITS Pilani

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

Thermoelectricity: From Atoms to Systems

Nanostructure. Materials Growth Characterization Fabrication. More see Waser, chapter 2

Homework Week 3: Nanoscale and macroscale characterization Thermoelectricity: From Atoms to Systems

Module 26: Atomic Force Microscopy. Lecture 40: Atomic Force Microscopy 3: Additional Modes of AFM

Bringing optics into the nanoscale a double-scanner AFM brings advanced optical experiments within reach

Contents. What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages

Nanoscale Heat Transfer at Contact Between a Hot Tip and a Substrate

Accurate thickness measurement of graphene

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

SUPPLEMENTARY INFORMATION

Supplementary Figure 3. Transmission spectrum of Glass/ITO substrate.

Kavli Workshop for Journalists. June 13th, CNF Cleanroom Activities

Investigation of Dynamical and Static Operation Modes of Atomic Force Microscope

Electrospun UV-responsive Supramolecular Nanofibers from Cyclodextrin-Azobenzene Inclusion Complex

Improving nano-scale imaging of of intergrated micro-raman/afm systems using negativestiffness

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

Introduction to Scanning Probe Microscopy Zhe Fei

Keywords- Focused Ion Beams, Nanostructuring, Polymers, Functionalization, Electron Microscopy, Surface Modification

Review. Surfaces of Biomaterials. Characterization. Surface sensitivity

Bridge between research in modern physics and entrepreneurship in nanotechnology. Quantum Physics

Revealing High Fidelity of Nanomolding Process by Extracting the Information from AFM Image with Systematic Artifacts

Transient Harman Measurement of the Cross-plane ZT of InGaAs/InGaAlAs Superlattices with Embedded ErAs Nanoparticles

Low Temperature (LT), Ultra High Vacuum (UHV LT) Scanning Probe Microscopy (SPM) Laboratory

Prototype 16: 3-omega thermal characterization chip (Device C )

Crystalline Surfaces for Laser Metrology

Precision Cutting and Patterning of Graphene with Helium Ions. 1.School of Engineering and Applied Sciences, Harvard University, Cambridge MA 02138

Scanning Tunneling Microscopy

Nanostructure Fabrication Using Selective Growth on Nanosize Patterns Drawn by a Scanning Probe Microscope

STM: Scanning Tunneling Microscope

Experimental methods in physics. Local probe microscopies I

κ T (2.1) In this work κ was not measured directly. Instead the thermal conductivity is expressed

Ecole Franco-Roumaine : Magnétisme des systèmes nanoscopiques et structures hybrides - Brasov, Modern Analytical Microscopic Tools

Controlled Electroless Deposition of Nanostructured Precious Metal Films on Germanium Surfaces

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

5. Building Blocks I: Ferroelectric inorganic micro- and nano(shell) tubes

MIT Department of Nuclear Science & Engineering

From nanophysics research labs to cell phones. Dr. András Halbritter Department of Physics associate professor

MAGNETIC FORCE MICROSCOPY

Program Operacyjny Kapitał Ludzki SCANNING PROBE TECHNIQUES - INTRODUCTION

ADVERTIMENT. Lʼaccés als continguts dʼaquesta tesi queda condicionat a lʼacceptació de les condicions dʼús

MSE 321 Structural Characterization

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

MSE 321 Structural Characterization

Apparatus to measure high-temperature thermal conductivity and thermoelectric power of small specimens

Application of the GD-Profiler 2 to the PV domain

Iodine-Mediated Chemical Vapor Deposition Growth of Metastable Transition Metal

SUPPLEMENTARY INFORMATION

Characterization of MEMS Devices

STRUCTURE AND DIELECTRIC PROPERTIES OF NANOCOMPOSITES ON THE BASIS OF HIGH-DENSITY POLYETHYLENE AND LEAD SULFIDE

Transcription:

SCANNING THERMAL MICROSCOPY OF THERMOELECTRIC PULSED LASER DEPOSITED NANOSTRUCTURES VANIŠ Jan 1,2, ZELINKA Jiří 1, ZEIPL Radek 1, JELÍNEK Miroslav 1, KOCOUREK Tomáš 1, REMSA Jan 1, NAVRÁTIL Jiří 3 1 Institute of Physics AS CR, v.v.i., Na Slovance 2, 18221, Prague, Czech Republic, EU 2 Institute of Photonics and Electronics AS CR, v.v.i., Chaberská 57, 18251, Prague, Czech Republic, EU 3 Institute of Macromolecular Chemistry, AS CR, v.v.i., Heyrovského nám. 2, 16206 Prague, Czech Republic, EU Abstract New materials with high possible figure of merit ZT are of high interest as a promising candidates for thermoelectric applications such as energy harvesting. Miniaturization of such systems tends toward developing of the suitable characterization method with nanometer resolution ability. In our contribution, we present the development and experimental results of a simple scanning probe microscopy method for the relative thermal conductivity characterization. The possibility of the setup is demonstrated on the set of different thin thermoelectric layers grown from hot pressed targets by pulsed laser deposition on the reference Si substrate. All the measurements were performed on the commercial Veeco Multimode scanning AFM/STM microscope with home developed controller and by using PicoCal Inc. bolometer probes with tungsten resistive path. All the experiments were done in the air at the ambient condition. Additional sample treatment for the measurement will be also briefly described Keywords: scanning thermal microscopy, figure of merit, thermoeletric materials 1. INTRODUCTION Thin layers, multi-layered structures and superlattices are suitable as a starting structures for thermoelectric nanodevices [1]. Knowledge of properties of such structures with lateral resolution in the nanometer scale is crucial from the point of view of nanophysics, nanoelectronics, nanomechanics and nanomedicine. Hence, there is need of techniques able to reach a nanometric spatial resolution. Scanning thermal microscopy (SThM), member of a family of scanning probe microscopies (SPM), shows its abilities since its invention in 1986 [2]. It is based on atomic force microscope (AFM) equipped with a thermal probe to carry out thermal images together with simultaneously obtained contact mode topography image[2,3]. At the beginning, thermocouple probes like AFM cantilever were used, in order to profit from force feedback. Nowadays mainly resistive thermal probes are used. They can operate in passive or active mode. In the passive mode, the temperature of the probe is estimated during scanning by measuring the voltage across the probe by means of the connected bridge. In an active mode, larger currents, which induce Joule heating in the probe, are passed through the probe resistor, inducing Joule heating in the probe. The heat flow between the probe and the sample is influenced by the thermal conductivity of the sample as well as of the thermal resistance at the probe-sample contact area. The active mode can be operated either in constant current mode or in constant temperature mode. In the constant current mode the resistance of the probe changes as a function of the heat flux between the probe and the sample. In the constant temperature mode the feedback loop cause a change of the current through the probe, so that the resistance of the probe does not change during the measurement [4,5]. We introduce a low frequency pulse current mode scanning thermal microscope method for the thermal conductivity evaluation of thin thermoelectric layers. The fast heating response of the cantilever tip on current flow is utilized as a scanning thermal probe. The ability of the suggested method is

demonstrated with a set of thermoelectric thin films of different thicknesses prepared by pulsed laser deposition (PLD) on silicon substrates. 2. EXPERIMENTAL RESULTS AND DISCUSSION For our experiments Bi2Te3, FeSb2Te and Ce0.1Fe0.7Co3.3Sb12 thermoelectric materials were used. The starting polycrystalline materials were synthesized from 99.999% starting compounds in evacuated silica ampoules at 1073 K for 48 hours. After verification of the homogeneity of the prepared compound by means of X-ray powder diffraction, the polycrystalline ingot was broken into small pieces with an agate mortar and sieved to obtain particle sizes below 100 μm. The target for PLD deposition of 20 mm in diameter and of 2 mm in height was prepared by the hot pressing method. The measured density of the pressed target reached about 96-98 % of the theoretical expected density. Layers were grown by PLD in apparatus described elsewhere [5, 6], where several improvements in hardware setup and growth procedure for achieving of smooth surface for every type of material were involved [6]. All layers were deposited on 10 mm x10 mm Si (100) substrate. For each type of material several thicknesses were grown. For all grown layers crystallinity, stoichiometry, roughness, Seebeck coefficient, in-plane electrical resistivity, and figure of merit (ZT) were measured by conventional analytical methods. For the thermal characterization of our samples in micron and submicron range using current pulse method we have used commercial SPM - Veeco MultiMode system with NanoScope IVa controller equipped with V version leak resistance ("J") scanner with a scanning range of 180 x 180 μm. For all measurements only one probe with the conductive path resistance of 49.3 Ohm and mean temperature coefficient of 1307 ppm/k was used. Cantilever is of 100 µm width, 2-3 µm thickness and 200 µm length. Over the tip deposited tungsten resistive stripe is two pole terminated. SEM picture of the used probe is shown in Fig. 1a). The probe is produced by Picocal Inc. To increase the system stability and sensitivity, the pulse regime instead of DC mode was used. Our method accounts the thermal characteristics of the used probe types, which have characteristic heating time constant of 0.4 ms (only the tip of cantilever is heated). We assume, that the time constant of the tip is substantially smaller then the rest part of the cantilever. Utilizing this knowledge, we drive the probe with about 400Hz rectangular current pulses of 50% duty cycle (1.2 ms heating up pulse width = 3 x heating time constant). Thus only the tip and the close vicinity area to the tip thermally pulsates, while the rest of the probe remains at its mean constant temperature. The lock in Fig. 1a) SEM image of the used thermal probe, 1b) general setup of the current pulse thermal conductivity measurement.

detector evaluates the amplitude of the signal from the differential amplifier, which is proportional to the difference of the tip resistivity during the heating pulses. Thus this significantly reduces the DC part of the signal proportional to the ambient temperature drifts. The general scheme of the current pulse thermal conductivity measurement using thermal microscope is shown in Fig.1b). The output controller voltage is indirectly proportional to the heat drain from the tip. In our case when the input power to the probe is set to 10 mw, it rises the mean temperature of the tip by 15 C and the pulses generates an extra 15 C. Hardware of our Veeco microscope heat up itself to 30 C, so the temperature of the tip pulsates within the range 45 C- 60 C. The measurements were taken in air at ambient condition. Although, the utilization of the new instrument in the measuring system increases sensitivity of the measurement for about two orders in comparison with the constant DC current mode and minimizes the influence of ambient interferences on the measurement, a comparison of the properties on each measured sample is possible only with respect to the reference silicon substrate. To obtain such structures, where is a steep edge between the reference silicon layer and the deposited material layer, ion induced milling process controlled by time of flight secondary ion mass spectrometer (TOF-SIMS) was involved. On each examined layer three 200 m x 200 m craters were milled of directly to the interface. Depth of the interface was determined from the TOF-SIMS depth spectra. All the milling processes were done away from the edges of the sample and Si/layer boundary, thus we expect that evaporated layer has the homogeneous thickness. The whole process was performed in SEM-FIB-GIS-SIMS Lyra TESCAN apparatus, where Ga + ion gun was used. For the atomic force thermal microscope characterization a set of three layers of different thickness were prepared for each material type. The FeSb2Te layers were 136 nm, 264 nm and 510 nm in thickness, Ce0.1Fe0.7Co3.3Sb12 were 146 nm, 300 nm and 738 nm in thickness, and Bi2Te3 layers were 155 nm, 415 nm and 900 nm in thickness. The typical image of measured topography and corresponding thermal signal is shown in Fig. 3 for the Bi2Te3 layer, the left-hand side shows the topography image and the right-hand side shows the corresponding thermal signal. The Si and Bi2Te3 parts of the sample are also marked in the image. The discontinuity of the thermal signal (-100 m) on the straight edge is due to the parasitic heat flow through the air surrounding the tip, which we will not describe here. As the samples are prepared on the same substrate and undergo same pre-measurement procedures, while the measurement parameters and conditions are also set to identical values, we can take the value of the relative change of thermal signal on the Si part as a reference. Fig. 2 Surface topography (on the left-hand side) and corresponding relative change of thermal signal (on the right-hand side) with corresponding step profile from the whole area (128 scans) for the edge of the milled crater on the Bi2Te3 layer with a thickness of 900 nm.

Numerical values of the relative change of thermal signal for Si and Bi2Te3 are taken in sufficient distance from the edge, where the signal is equalized. Such normalized thermal signals with respect to the silicon substrate (left part of the image) is shown in Fig. 3 for Bi2Te3 of different thickness (right part of the image). Fig. 3 Response of the thermal signal for the Bi2Te3 layers of different thickness equalizes with the respect to silicon layer. Computed difference of these levels is directly proportional to the thermal resistivity of the measured material and its dependence on the thickness of layer for all FeSb2Te, Ce0.1Fe0.7Co3.3Sb12 and Bi2Te3 materials is shown in Fig. 4. The shown dependence on the layer thickness has a linear character for Bi2Te3 and Ce0.1Fe0.7Co3.3Sb12 whereas for the FeSb2Te, it cannot be estimated because of the value spread. Fig. 4. Dependence of the relative change of the thermal signal on the layer thickness for FeSb2Te, Ce0.1Fe0.7Co3.3Sb12 and Bi2Te3. 3. CONCLUSION In our contribution we demonstrate the feasibility of the relative thermal conductivity measurement with the new electronic instrument working in pulsed current mode. The specific heating behavior of our Picocal Inc. thermal probes is used. We prove higher sensitivity of the method in comparison with DC method. The nanometer range resolution of FeSb2Te, Ce0.1Fe0.7Co3.3Sb12 and Bi2Te3 layers with different thickness is shown, where linear dependence of the relative thermal conductivity on thickness was found. To validate our

results, additional measurements on different layer thickness are required and a comparison with 3 method would be also interesting. The bottleneck of the method is parasitic heat flow through air, which should be cut off by performing the measurements in the vacuum. ACKNOWLEDGEMENTS This work was supported by the Grant Agency of the Czech Republic project no. GA13-33056S. REFERENCES [1] VENKATASUBRAMANIAN R.,COLPITS T.S.,MALTA D.,MANTINI M.,PROCEEDINGS OF THE EUROPEAN THERMOELECTRIC SOCIETY, ST. PETERSBURG, 1995, P.490 UNITED STATES PATENT NO. 5,747,728 (MAY 5, 1998). [2] WILLIAMS C.C., WICKRAMASINGHE H.K. Scanning thermal prfoiler, Applied Physics Letters Vol. 49, 1986, pp. 1587. [3] MAJUMDAR A.,LAI J,CHANDRACHOOD M.,NAKABEPPU O.,WU Y.,SHI Z. Thermal imaging by atomic force microscopy using thermocouple cantilever probes, Review of Scientific Instruments. 66, 1995, pp. 3584. [4] MAJUMDAR A. Scanning thermal microscopy, Annu. Rev. Mater. Sci. 29, (1999), pp. 505-585. [5] ZEIPL R., JELINEK M.,KOCOUREK T.,REMSA J.,VANIŠ J.,VLČEK M. Properties of Thermoelectric Nanocomposite Bi2Te3 Layers Prepared by PLD, Sensors and Transducers Journal 183(12), 2014, pp. 103-109 [6] REMSA J.,JELINEK M.,KOCOUREK T.,ZEIPL R., NAVRATIL J., Very smooth FeSb2Te and