technical reprint R/P098 fast timing with slow scintillators

Similar documents
a monte carlo simulation of photomultiplier resolution

Chapter 4 Scintillation Detectors

A new timing model for calculating the intrinsic timing resolution of a scintillator detector

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

New Scintillators for the Border Monitoring Equipment

Scintillation Detectors

DELAYED COINCIDENCE METHOD FOR PICOSECOND LIFETIME MEASUREMENTS

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

arxiv: v1 [physics.ins-det] 3 Feb 2011

Hands on Project: Large Photocathode PMT Characterization

Lecture 9. PMTs and Laser Noise. Lecture 9. Photon Counting. Photomultiplier Tubes (PMTs) Laser Phase Noise. Relative Intensity

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

Photomultiplier (PMT) basic elements

PoS(PhotoDet 2012)010

Non-proportionality of organic scintillators and BGO

Performance of the MCP-PMT for the Belle II TOP counter

High quantum efficiency S-20 photocathodes for photon counting applications

arxiv: v1 [physics.ins-det] 29 Jun 2011

Scintillation Detectors

Scintillation Detectors

OPPORTUNITY TO JOIN IEEE AND NPSS

M.J. CIESLAK, K.A.A. GAMAGE Department of Engineering, Lancaster University Lancaster, LA1 4YW United Kingdom ABSTRACT

SCINTILLATION DETECTORS AND PM TUBES

arxiv:hep-ex/ May 2000

Energy Resolution of Scintillation Detectors New Observations

Week 6: Ch. 8 Scintillation Counters

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

MCNP analysis and optimization of a double crystal phoswich detector

Design of a Lanthanum Bromide Detector for TOF PET

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

Charged particles detectors Arrays (1)

Multi-Photon Time Resolution and Applications

Measuring Cosmic Ray Muon Decay Constant and Flux

Waveform Analysis for DM-Ice17. Zachary Pierpoint University of Wisconsin - Madison October 21, 2013 Yale Weak Interactions Discussions Group

Design and production of Scintillation Detectors

Studies of Hadron Calorimeter

Scintillation Detectors

arxiv:physics/ v1 3 Aug 2006

arxiv:hep-ex/ v1 22 Apr 2002

Characterisation of Silicon Photomultipliers for the T2K Experiment

Key words: avalanche photodiode, soft X-ray detector, scintillation γ-ray detector, imaging device PACS: 07.85;95.55.A;85.60.D

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Overview Physical processes PMT and electronics response Some results Plans

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

Sample Spectroscopy System Hardware

The fast light of CsI(Na) crystals

Measurement of Muon Lifetime

Week 4: Chap. 4 Basic Detector Principles

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

MEASURING THE LIFETIME OF THE MUON

INORGANIC crystal scintillators are widely used in high

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

PHOTODETECTORS AND SILICON PHOTO MULTIPLIER

ORTEC. Counters/Ratemeters/ Multichannel Scalers. Choosing the Right Counting Solution. The Basic Functions of Counting Systems

Introduction to Radiation Monitoring

Radioactivity and Ionizing Radiation

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

ORTEC. Time-to-Amplitude Converters and Time Calibrator. Choosing the Right TAC. Timing with TACs

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Development of a Pulse Shape Discrimination IC

Status of KIMS-NaI experiment

EEE4106Z Radiation Interactions & Detection

DETECTORS. I. Charged Particle Detectors

Scintillators General Characteristics

Study of the LHC Luminosity at the ATLAS Experiment using Scintillating Counters

Radiation Detection and Measurement

Characterization of the Lanthanum Chloride Scintillation Detector

The Dual-Phase Liquid Xenon Time Projection Chamber (TPC) of Münster

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

Measurement of the transverse diffusion coefficient of charge in liquid xenon

New solid state photomultiplier. Dmitry Shushakov and Vitaly Shubin

Development of a High Precision Axial 3-D PET for Brain Imaging

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

arxiv: v2 [physics.ins-det] 8 Feb 2013

X-ray ionization yields and energy spectra in liquid argon

Researchers at the University of Missouri-Columbia have designed a triple crystal

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Chapter 6: Basic radiation detectors

Primary Standardization of 152 Eu by 4πβ(LS) γ (NaI) coincidence counting and CIEMAT-NIST method

PHYS 3446 Lecture #12

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

Calibration and Comparison of Chlorine Decay Models for a Test Water Distribution System

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

CCD readout of GEM-based neutron detectors

arxiv: v1 [nucl-ex] 6 May 2008

05 - Scintillation detectors

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Counting Photons to Calibrate a Photometer for Stellar Intensity Interferometry

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Unit 2. Instrumentation. Experts Teaching from Practical Experience

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

Alpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal

Precision Polarimetry at JLab, 6 GeV Era G. B. Franklin Carnegie Mellon University

Advances in the Micro-Hole & Strip Plate gaseous detector

Introduction to scintillators

Transcription:

technical reprint R/P98 fast timing with slow scintillators

fast timing with slow scintillators Q(t) = 1 (1 - exp (-t/ ô )) A G Wright, Electron Tubes Ltd., Bury Street, Ruislip, HA4 7TA, UK Q(t) note gap actual emission times technical reprint R/P98 1 introduction This study concerns timing with slow, inorganic scintillators; particularly where the emission involves few photons. Monte Carlo simulations are used to mimic the statistical nature of both the light emission and the photomultiplier (pmt) behaviour. Simulated waveforms highlight practical difficulties concerning multiple triggering. Important pmt attributes are discussed. This topic was extensively studied fifty years ago following the seminal paper by Post and Shiff [1] which set an upper limit to timing fidelity. Gatti [2] and his co-workers allowed for pmt parameters, such as single electron response (SER) and transit time jitter. Although analytic solutions can sometimes be found, most authors ultimately resort to Monte Carlo simulations, and this approach has been adopted in the present work. Early work (τ ~1ns) concerned fast plastic scintillators but currently there is growing interest in timing with high Z, slow scintillators (τ ~5 ns). These are listed in table 1 together with the relatively new, high Z, scintillators. The intention in this paper is to understand how pmt parameters affect timing with slow scintillators, especially where photon numbers are low. Consideration is given to Constant Fraction (CF) discrimination. 2 time distribution of photons.5 1 figure 1 the random nature of photon emission from a scintillator - the accentuated time gaps are of particular concern. table 1 timing characteristics. ρ is the density g/cm 3 and ph/kev is the photon yield per kev scintillator ρ τ, ns ph/kev R/τ(FOM) BC418 1.3 1.4 8 5.7 BC4 1.3 2.4 8 3.3 LaCl 3 3.79 28 49 1.8 LuAP 8.3 18 2 1.1 YAP(Ce) 5.55 28 7.25 NaI(Tl) 3.67 25 4.16 CsI(Tl) 4.51 1 6.6 BGO 7.13 3 8.3 CdWO 4 8. 5 14.3 The probability distribution, P(t), for the arrival of the Qth photon, at a time between t and t + dt is given by [1] and [3], where R is taken as the mean of a Poisson distribution p(n) = R n e -R /n! P(t) = R Q exp(-r(1-e -t/τ ))(1-e -t/τ ) Q-1 e -t/τ dt...(2) Timing distributions for various values of Q are plotted in figure 2 for R = 1 and τ = 25 ns. The variance of P is given in [1], subject to R>>1 and R>>Q, as var(q) = Q (τ/r) 2 (1 + 2(1+Q)/R + )...(3) Restricting ourselves to small volume scintillators, the light output from to t may be taken as.5 Q = 1 Q = 1 Q(t) = R(1- e -t/τ )... (1) where R is the total number of photons in the pulse. (1) is plotted in figure 1 together with a simulation showing how an actual event follows a random walk. dp(t)dt.25 Q = 2 Q = 3.4.8.12.16.2 Q = 4 figure 2 timing distributions for the arrival of the Qth photon out of R. Best timing is obtained with Q = 1, where P(t) ~ R/τ exp(-(r+1)τ/t).

Otherwise the variance must be calculated from the curves of figure 2. Equation 3 suggest a Figure of merit (FOM) = R/τ for σ(q), the standard deviation. Table 1 lists a range of scintillators and their major properties of interest. So far we have considered the statistics of light emission from a scintillator. Considering the pmt the foregoing treatment, however, applies equally to photoelectron emission and we need only take the quantum efficiency into account. 3 effect of pmt parameters 3.2 noisy gain, (noise factor = NF) The single electron response (SER) of a pmt is the pulse height distribution for anode signals initiated by single photons. A noiseless multiplier is characterised by a δ-function response, such as (a) in figure 4. Plot (b) illustrates a 'good' SER, showing a peak in the distribution, whereas curve (c) shows a noisy multiplier with an exponential-like distribution. We define a noise factor, NF = [1+ ε A ] 1/2, where ε A = var(h)/<h> 2, is the gain dispersion, calculated directly from the SERs shown in figure 4. 1 3.1 transit time dispersion, ε ph Simulations were run to select photoemission times in accordance with (1). The time dispersion of the multiplier was mimicked by randomising the arrival time of each pulse at the anode in accordance with a normal distribution, characterised by (µ,ε ph ), p(h)dh (c) (a) SER NF = [1 + var(h)/h 2 ] 1/2 (a) 1 (b) 1.17 (c) 2 1/2 (b) where µ is the mean transit time and ε ph is its standard deviation. The arrival times at the anode were then ordered to provide the time signature of an R- photoelectron event. This was repeated many times yielding a distribution from which to calculate σ(q). The results shown in figure 3 illustrate that pmt jitter is not significant where photon-poor signals are concerned, whereas for R = 5 (~5 kev in NaI(Tl)), for example, the timing is dominated by the pmt performance. sigma ns 4 3 2 1 (a) R = 1 1 1 1.5 1 1.5 2 2.5 3 h photoeletrons equivalent figure 4 pmt single electron response curves, SER.(a) noiseless gain (b) a 'good' SER and (c) a poor SER. 4 the signal forming process at the anode We assume a characteristic anode pulse shape, i(t), prescribed for every photoelectron-initiated event. If q = e<g> then i(t) = q/τ s exp(-t/τ s ) where τ s is the characteristic width of the anode pulse. More complicated forms may be assumed for i(t) but the above is sufficient. The signal at the anode, describing the entire scintillation event is given by convolution. I(t) = Q'(t)! i(t) = Rq /(t - τ s ) [exp(-t/τ)- exp(-t/τ s )]...(4) 4 (b) R = 5 Q/R % We can derive an expression for the voltage signal across an anode load of R' // C' from (4), thus sigma ns 3 2 v (t) = R'qRτ / [(τ - τ s )(τ - τ)] (e -t/τ - e t/τ ) -R'qRτ s / [(τ - τ s )( τ - τ s )] (e t/τ s - e t/τ )...(5) 1.1.1 1 1 1 Q/R % figure 3. σ(q) determined directly from (2),+, compared with (3), solid line. R = 1 and 5 for (a) and (b) respectively. The marked effect of pmt jitter is evident in (b) where it dictates the performance for Q/R <1%. The sporadic error bars give an indication of the precision of the simulations.!: ε ph = 1 ns; ": = 2.5 ns; x = 5 ns The anode waveform generated by the light emission profile of Figure 1 is now analysed. First, in figure 5(a) we consider the current waveform I(t) = Σ i(τ n ) where n = to 1. The amplitude of i(t) is allowed to vary in accordance with the SER of figure 4(b). Note the ragged appearance of the pulse; the excessive gap in arrival times after about 8 ns, in the particular example given in figure 1, causes the output signal to drop to zero. It is clear

(a) output (b) (c) (d) R'C' = 5 ns.3.6.9 1.2 that if discrimination were attempted on this waveform, at a threshold of say two units on the ordinate, then multiple triggering would result. Figure 5(b) refers to (4) and it is the average profile followed by events of type (a). (c) refers to (5) where R'C' has been taken as 5 ns while (d) is the average profile followed by (c). figure 5 a simulation with R = 1, τ = 25 ns, τ s = 5 ns, τ = 5 ns NF = 1.17 and ε ph = 5 ns. Note the area under all curves is the same. figure 7 for two hundred simulations. The sigma of the distribution is degraded directly by the noise factor NF and pmt jitter is responsible for the early arrival times. 5 4 5 discriminator considerations The effect of pmt jitter overules the prediction that timing based on the detection of the first photon (Q = 1) will always lead to optimal timing (see figure 3) We can take advantage of this to get better timing at the higher Q values while overcoming the possibility of multiple triggering, as observed in figure 5. A discriminator based on the constant fraction (CF) technique [4] is preferred for experimental work because it avoids the problem of walk. An inverted fraction of the pulse is added to a delayed version of the pulse itself making the time of zero-crossing walk-free, as illustrated in figure 6. output v(t) 2 1.5 1.5 -.5 delayed arrival of first photoelectron (2) (1) + (2) CF zero crossing time = 78 ns (1).1.2.3.4 figure 6 applying the CF technique to the waveform of figure 5(c). (2) is the main signal delayed by 5 ns; (1) is an attenuated version of (1) without delay; (1)+(2) is the sum of these two signals. The distribution for zero-crossing times is shown in P(t)dt 3 2 1 figure 7 CF timing distributions based on 2% and 5 ns delay.! noiseless gain (NF =1); " NF = 1.17 ;! NF = 1.414. The solid line is equation (2) with Q = 5. 6 conclusions from (2) Q = 5 6 7 8 9 1 11 t ns fast timing with slow scintillators is possible if R/τ is sufficiently large although the scintillator decay time is much larger than the pmt jitter, pmt jitter is important at low Q values a poor SER degrades timing under all conditions and directly as the noise factor NF smoothing is necessary to prevent multiple triggering with a constant fraction discriminator, limited smoothing does not degrade performance. always resort to experiment with regard to smoothing, threshold, delay and trigger fraction Important pmt properties are: high QE, good collection efficiency, good SER and low jitter as always.

7 references [1] R. F. Post and L.I. Shiff. Phys. Rev. 8 (195) 1113 [2] E. Gatti and V. Svelto Nucl. Instr.and Meth. 43 (1966) 248 [3] G. Ranucci. Nucl. Instr. and Meth. A 335(1993) 121 [4] D.A. Gedcke and W.J. McDonald Nucl. Instr. and Meth. 58 (1968) 253

talk to us about your application or choose a product from our literature: photomultipliers, voltage dividers, signal processing modules, housings and power supplies ET Enterprises Limited 45 Riverside Way Uxbridge UB8 2YF United Kingdom tel: +44 () 1895 288 fax: +44 () 1895 27873 e-mail: sales@et-enterprises.com web site: www.et-enterprises.com ADIT Electron Tubes 3 Crane Street Sweetwater TX 79556 USA tel: (325) 235 1418 toll free: (8) 521 8382 fax: (325) 235 2872 e-mail: sales@electrontubes.com web site: www.electrontubes.com choose accessories for this pmt on our website an ISO 91 registered company The company reserves the right to modify these designs and specifications without notice. Developmental devices are intended for evaluation and no obligation is assumed for future manufacture. While every effort is made to ensure accuracy of published information the company cannot be held responsible for errors or consequences arising therefrom. ET Enterprises Ltd, 211 DS_ R/P98 Issue 3 (18/1/11)