MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8

Similar documents
SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Series CCR-39S Multi-Throw DC-12 GHz, SP7T & SP8T Latching Coaxial Switch

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch

Series CCT-58S Multi-Throw DC 18 GHz, SP7T & SP8T Normally Open Coaxial Switch

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch

24 volts (0.25 amps current-limited)

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

NTE74177 Integrated Circuit TTL 35Mhz Presettable Binary Counter/Latch

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Miniature Electronically Trimmable Capacitor V DD. Maxim Integrated Products 1

Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II)

TEC BACnet MS/TP Network Series Thermostat Controllers Technical Bulletin

Pressure Display Controller

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card

POINTS OF CAUTION BEFORE USE...

MM74C150 MM82C19 16-Line to 1-Line Multiplexer 3-STATE 16-Line to 1-Line Multiplexer

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

NTE74176 Integrated Circuit TTL 35Mhz Presettable Decade Counter/Latch

Installation Instructions

RF (Radio Frequency) C R 20 Type

DS0026 Dual High-Speed MOS Driver

An Autonomous Nonvolatile Memory Latch

Memory, Latches, & Registers

LECTURE 28. Analyzing digital computation at a very low level! The Latch Pipelined Datapath Control Signals Concept of State


Digital Fluxmeter CYHT700SP

Safety Barriers Series 9001, 9002 Standard Applications

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

32 Input AC Block I/O Module

HIGH SPEED-10 MBit/s LOGIC GATE OPTOCOUPLERS

INTEGRATED CIRCUITS. 74LVC138A 3-to-8 line decoder/demultiplexer; inverting. Product specification 1998 Apr 28

MARKING DIAGRAMS DIP PIN ASSIGNMENT ORDERING INFORMATION TRUTH TABLE CDIP 16 L SUFFIX CASE 620 MC10165L AWLYYWW

Common Lightcloud Wiring Applications. Wiring Diagrams. Overview Controller Dimmer Gateway Integrator Sensor Touch. Lightcloud

activar - Performance in Mitigating Voltage Sags Associated with Motor Starting

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

ECE2210 Final given: Fall 13

16 Input AC Block I/O Module

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

INTEGRATED CIRCUITS. 74ALS138 1-of-8 decoder/demultiplexer. Product specification 1996 Jul 03 IC05 Data Handbook

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

PHYS225 Lecture 9. Electronic Circuits

Compact, Dual-Output Charge Pump

INTEGRATED CIRCUITS. 74F154 1-of-16 decoder/demultiplexer. Product specification Jan 08. IC15 Data Handbook

E40M Review - Part 1

SOME USEFUL NETWORK THEOREMS

Tuneable White DMX LED Driver

NTE74HC299 Integrated Circuit TTL High Speed CMOS, 8 Bit Universal Shift Register with 3 State Output

NTE74LS181 Integrated Circuit TTL Arithmetic Logic Unit/Function Generator

INSTRUCTIONS FOR ASSEMBLY AND OPERATION

Instruction Manual. DTP Series DC Termination Panels

MM74C90 MM74C93 4-Bit Decade Counter 4-Bit Binary Counter

Digital Design through Pi

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

EXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00

5.0 CMOS Inverter. W.Kucewicz VLSICirciuit Design 1

13 Amp Programmable DC/DC Regulator PTK series. 3.3VDC, 5VDC, or 12VDC Input

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features

Application Note. Paralleling of EconoPACK TM + Date: Page

Vidyalankar S.E. Sem. III [EXTC] Digital Electronics Prelim Question Paper Solution ABCD ABCD ABCD ABCD ABCD ABCD ABCD ABCD = B

Applications LED READY = READY LED READY LED. Charge mode indicator. max 140 C Shunt Sense Osc. Figure 1 Block diagram with external circuit

Model M3484 Industrial Line Noise Filter Module Customer Reference Manual

3 Channel Constant Current DMX LED Driver

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

2Ω, Quad, SPST, CMOS Analog Switches

INTEGRATED CIRCUITS. 74F85 4-bit magnitude comparator. Product specification 1994 Sep 27 IC15 Data Handbook. Philips Semiconductors

LOGIC CIRCUITS. Basic Experiment and Design of Electronics. Ho Kyung Kim, Ph.D.

DM7445 BCD to Decimal Decoders/Drivers

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

LECTURE 6 MUTUAL INDUCTANCE

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

BCD-TO-DECIMAL DECODER HIGH-VOLTAGE SILICON-GATE CMOS IW4028B TECHNICAL DATA

ECE2210 Final given: Spring 08

EE141Microelettronica. CMOS Logic

Varistor Voltage. D: Disk, S: Square S:Straight, C:Crimped, I:Inner, Y:Y kink Size(mm) B: Bulk (Standard lead 20mm min.)

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV

ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M

Impedance relay and protection assemblies

Lab Manual Solutions Industrial Control Electronics: Devices, Systems, and Applications

SN74LS151D LOW POWER SCHOTTKY

CANBUS-THERMO-2CH Rev B v Channel CAN-Bus Thermocouple Interface K-Type. V1.0 July SK Pang Electronics Ltd

General Purpose Relays Types K, R, N, and C

Dynamic Combinational Circuits. Dynamic Logic

PHOTO SCR OPTOCOUPLERS

DIM. A (+ 0,05 0,51) .135 ±.015 (3,43 ± 0,38) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE 1/4-32 UNEF-2A THREAD

PHOENIX CONTACT - 04/2016. Features

NTE4514B & NTE4515B Integrated Circuit CMOS, 4 Bit Latch/4 to 16 Line Decoder

VFD- RoHS Compliant M0116MY-161LSBR2-1. User s Guide. (Vacuum Fluorescent Display Module) For product support, contact

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

4-bit magnitude comparator

user's manual nx frequency converters resolver option board opt-bc

CD4514BC CD4515BC 4-Bit Latched/4-to-16 Line Decoders

54AC258 54ACT258 Quad 2-Input Multiplexer with TRI-STATE Outputs

MM82C19 16-Line to 1-Line Multiplexer

Chapter 9 Bipolar Junction Transistor

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Chip tantalum capacitors (Fail-safe open structure type)

U1 is zero based because its noninverting terminal is connected to circuit common. Therefore, the circuit reference voltage is 0 V.

Transcription:

February 1994 20/20 Interface Products MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS & DESCRIPTION The is a Multi-output Programmable Controller which expands the input or output capability of building automation controllers. The has 8 SPDT output relays that provide ON/OFF control from a jumper-selectable or analog (current or voltage) input signal. The sequence of operation can be easily selected by DIP switches. A Dual mode allows two (2) UMXs to be controlled in sequence from a single input signal. HOA switches allow for manual override of each relay output. Feedback and LEDs provide status indication of the. The provides 4 SPDT output relays. All jumper positions and DIP switch settings are identical to the. The operation of the is identical to relays 1-4 on the. Feedback and LEDs provide status indication of the. Standard control sequences include: Multiplexed 4 or 8 relay output expander - provides standard 4 or 8 output expansion from one BAS output. Multiplexed 4 or 8 input expander - provides standard 4 or 8 input expansion from one BAS output and one BAS input. RTU or AHU controller - provides multi-stage heating and cooling sequences with economizer. Sequencer - 4 or 8 stages of sequential control. Custom sequences are available - consult Kele engineering for details. FEATURES Four (4) or eight (8) SPDT relay outputs HOA switches LED status indication Field-selectable programs Output status feedback Override indication Field-selectable or analog current or voltage input Pull-apart terminal blocks SPECIFICATIONS Supply voltage Input signal* Input impedance Output relays Override output status : 24 VDC ±10% @ 90 ma max 24 VAC ±10% @ 210 ma max : 24 VDC ±10% @ 150 ma max 24 VAC ±10% @ 350 ma max, 0-20 ma, 0-5V, 0-10V, 0-15V, jumper-selectable Current: 250 Ω Voltage: 46.4 kω min : 4 SPDT, 5A @ 24 VDC/24 VAC : 8 SPDT, 5A @ 24 VDC/24 VAC Transistor switch, 30 VDC @ 100 ma max Status feedback : 1 output, 1-5V for relays 1-4 : 2 outputs, 1-5V for relays 1-4 and 1-5V for relays 5-8 Feedback load current 3 ma max per output Operating temp 32 to 158 F (0 to 70 C) Humidity 95% noncondensing Dimensions ( & ) 7"W x 3.25"H x 1.56"D 17.78 cm x 8.25 cm x 3.96 cm *Each input command signal (as listed in the control sequence tables) may vary up to 35% of the change to the next highest or lowest command signal (as shown in tables) and still be considered valid. KELE & ASSOCIATES P O Box 34817 Memphis, TN 38184 901-382-4300 FAX 901-372-2531 new 2/94, -8

OPERATION Single and Dual UMX Control - The UMX can be operated in both a single and dual operating mode. In the single mode, one UMX is controlled from a single analog or signal. In the dual mode, 2 UMXs are controlled in sequence, providing 16 relay outputs from a single analog or signal. This dual UMX control is not available with all control sequences. Refer to the control sequence tables for availability. If single UMX control is to be used, refer to Table 1 for DIP switch settings. For dual UMX control, refer to Table 2. Pulse Width Modulation () To control the UMX from a signal, put the input selection jumper on the UMX in the PW position. Set the operating mode DIP switches (Table 1 or Table 2) as required. Refer to the control sequence tables for time base and control sequence information. Analog Input (ANA) The UMX can be controlled from an analog current or voltage input. To operate in this mode, set the input selection jumpers on the UMX as shown in this table: Analog Input Jumpers Analog input 0-20 ma 0-5V 0-10V 0-15V AN MA 5V 10V 15V OPERATING MODE (DIP SWITCHES 1, 2, 3, & 4) Table 1 Single Unit UMX Control DIP SWITCHES ANA L1 L2 HSL CSL SVT LVT 1 2 3 4 X 0 0 0 1 X X X 0 1 0 0 X X X 0 1 0 1 X X X 0 1 1 0 X X X 0 1 1 1 = Input Signal ANA = Analog Input Signal L1 = Level 1 UMX (Dual UMX Mode) L2 = Level 2 UMX (Dual UMX Mode) HSL = Hold Outputs on Signal Loss (Analog Input Mode) CSL = Clear Outputs on Signal Loss (Analog Input Mode) SVT = Short Signal Validation Time (Analog Input Mode) LVT = Long Signal Validation Time (Analog Input Mode) DIP Switches: 0 = OFF 1 = ON Table 2 Dual UMX Control DIP SWITCHES ANA L1 L2 HSL CSL SVT LVT 1 2 3 4 X X 0 0 1 0 X X 0 0 1 1 X X X X 1 0 0 0 X X X X 1 0 0 1 X X X X 1 0 1 0 X X X X 1 0 1 1 X X X X 1 1 0 0 X X X X 1 1 0 1 X X X X 1 1 1 0 X X X X 1 1 1 1 L1, L2 - UMX Levels - Dual UMX Mode Only - In the Dual UMX mode, two (2) UMXs respond in sequence to a single input signal. Using the DIP switch settings shown in Table 2, assign the first UMX to Level 1(L1) and the second UMX to Level 2 (L2). Dual UMX control is available in most analog and modes. time base doubles in Dual UMX mode. HSL, CSL - Signal Loss Hold - Analog Input Mode Only - When using an analog input, the UMX can be programmed to either hold all relays in their current state (HSL) or turn all relays off (CSL) upon a loss of the input signal. Use DIP switch settings shown in Table 1 or Table 2 to program this feature. SVT, LVT - Signal Validation Time - Analog Input Mode Only - When varying an analog input signal to the UMX, it is necessary for the input signal to remain at the desired value for a set length of time. This prevents other relays on the UMX from energizing while the input signal is changing values. This set length of time, or validation time, can be programmed to either 1 second (SVT) or 3 seconds (LVT). Use the DIP switch settings in Table 1 or Table 2 to select the validation time. 2

CONTROL SEQUENCE TABLES Output Expander with Input (Table 3)...page 5 Output Expander with Analog Input (Table 4)...page 6 Input Expander with or Analog Input (Table 5)...page 7 Multi-stage Sequencer with or Analog Input (Table 6)...page 8 Rooftop Unit or AHU Controller with or Analog Input 2 cooling and 2 heating stages, economizer (Table 7)...page 9 3 cooling and 3 heating stages, economizer (Table 8)...page 10 Alternate control sequence for 3 cooling and 3 heating stages, economizer (Table 9)...page 11 WIRING - SINGLE UMX LED INDICATION : RELAY LEDS (RED): ON WHEN RELAY IS ENERGIZED IN "AUTO" OR "HAND" POSITION LED INDICATION : POWER (GREEN): (YELLOW): OVERRIDE (RED): HAND OVERRIDE OFF AUTO POWER R.E. TECHNOLOGIES INPUT JUMPERS ON WHEN POWER IS PRESENT ON WHEN SIGNAL IS PRESENT ON WHEN ANY OVERRIDE SWITCH IS OUT OF THE "AUTO" POSITION FBK2 FBK1 24V PWR COM ANA OVERRIDE 24V NOTE: R V39ZA1 VARISTOR ANY OUTPUTS DRIVING AN EXTERNAL RELAY OR AN INDUCTIVE LOAD SHOULD HAVE A VARISTOR INSTALLED AT THE RELAY AS SHOWN. FEEDBACK STATUS (1-5 VDC) FOR RELAYS 5-8 FEEDBACK STATUS (1-5 VDC) FOR RELAYS 1-4 24 VAC OR 24 VDC POWER SUPPLY COMPUTER CONTACTS CAN BE INSERTED IN EITHER LEAD. 24 VAC OR 24 VDC FOR SIGNAL (IF USED). SIGNAL IS OPTOISOLATED AND POLARITY INSENSITIVE. ANY 24 VAC OR DC SOURCE CAN BE USED FOR THE SIGNAL ANALOG CURRENT OR VOLTAGE INPUT SIGNAL (IF USED) OVERRIDE OUTPUT, TRANSISTOR SWITCH 30 VDC @ 100 MA MAX, SWITCH CLOSES TO COMMON WHEN ANY OVERRIDE SWITCH IS OUT OF THE "AUTO" POSITION. NOTE: IF DRIVING A DC RELAY, A REVERSE CONNECTION DIODE IS RECOMMENDED ACROSS THE RELAY COIL (SUCH AS 1N4004). 3

WIRING - DUAL UMX INPUT SIGNAL LEVEL 1 UMX LEVEL 2 UMX FBK2 FBK1 24V PWR COM ANA OVERRIDE FBK2 FBK1 24V PWR COM ANA OVERRIDE 24 VAC OR 24 VDC POWER SUPPLY COMPUTER CONTACTS CAN BE INSERTED IN EITHER LEAD. 24 VAC OR 24 VDC FOR SIGNAL SIGNAL IS OPTOISOLATED AND POLARITY INSENSITIVE. ANY 24 VAC OR DC SOURCE CAN BE USED FOR THE SIGNAL. (INPUT JUMPERS SET TO "PW" POSITION ON BOTH UMX BOARDS) ANALOG INPUT SIGNAL LEVEL 1 UMX FBK2 FBK1 24V PWR COM ANA OVERRIDE 24 VAC OR 24 VDC POWER SUPPLY LEVEL 2 UMX FBK2 FBK1 24V PWR COM ANA OVERRIDE CURRENT OR VOLTAGE ANALOG INPUT SIGNAL (SEE TABLE FOR INPUT JUMPERS) INPUT JUMPERS INPUT LEVEL 1 LEVEL 2 SIGNAL UMX UMX 0-5 V AN/5V AN/5V 0-10V AN/10V AN/10V 0-15V AN/15V AN/15V 0-20 MA AN/MA AN/5V 4

Table 3 Control Sequences OUTPUT EXPANDER WITH INPUT - Provides 4, 8, 12, or 16 relay outputs controlled from a single BAS pulse-width modulated output. A time base of 9, 18, or 36 seconds is available. OFF,OFF,OFF,OFF OFF,OFF,OFF,ON Level 2 Level 1 0.5 1. 0 1.0 2.0 X X X X X X X 1 1.5 3.0 X X X X X X X 0 2.0 4.0 X X X X X X 1 X 2.5 5.0 X X X X X X 0 X 3.0 6.0 X X X X X 1 X X 3.5 7.0 X X X X X 0 X X 4.0 8.0 X X X X 1 X X X 4.5 9.0 X X X X 0 X X X 5.0 10.0 X X X 1 X X X X 5.5 11.0 X X X 0 X X X X 6.0 12.0 X X 1 X X X X X 6.5 13.0 X X 0 X X X X X 7.0 14.0 X 1 X X X X X X 7.5 15.0 X 0 X X X X X X 8.0 16.0 1 X X X X X X X 8.5 17.0 0 X X X X X X X 9.0 18.0 9.5 19.0 10.0 20.0 X X X X X X X 1 10.5 21.0 X X X X X X X 0 11.0 22.0 X X X X X X 1 X 11.5 23.0 X X X X X X 0 X 12.0 24.0 X X X X X 1 X X 12.5 25.0 X X X X X 0 X X 13.0 26.0 X X X X 1 X X X 13.5 27.0 X X X X 0 X X X 14.0 28.0 X X X 1 X X X X 14.5 29.0 X X X 0 X X X X 15.0 30.0 X X 1 X X X X X 15.5 31.0 X X 0 X X X X X 16.0 32.0 X 1 X X X X X X 16.5 33.0 X 0 X X X X X X 17.0 34.0 1 X X X X X X X 17.5 35.0 0 X X X X X X X 18.0 36.0 5 X X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X X

Table 4 Control Sequences OUTPUT EXPANDER WITH ANALOG INPUT - Provides 4 or 8 relay outputs controlled from a single BAS analog voltage or current output. "Dual" UMX control is not available with this sequence. OFF, OFF, ON, OFF OFF, OFF, ON, ON 3.5 0.75 1.5 2.25 4.0 1.00 2.00 3.00 4.0 1.00 2.00 3.00 4.9 1.24 2.47 3.71 5.0 1.25 2.50 3.75 5.9 1.47 2.94 4.41 6.0 1.50 3.00 4.50 6.8 1.71 3.41 5.12 7.0 1.75 3.50 5.25 7.8 1.94 3.88 5.82 8.0 2.00 4.00 6.00 8.7 2.18 4.35 6.53 9.0 2.25 4.50 6.75 9.7 2.41 4.82 7.24 10.0 2.50 5.00 7.50 10.6 2.65 5.29 7.94 11.0 2.75 5.50 8.25 11.5 2.88 5.76 8.65 12.0 3.00 6.00 9.00 12.5 3.12 6.24 9.35 13.0 3.25 6.50 9.75 13.4 3.35 6.71 10.06 14.0 3.50 7.00 10.50 14.4 3.59 7.18 10.76 15.0 3.75 7.50 11.25 15.3 3.82 7.65 11.47 16.0 4.00 8.00 12.00 16.2 4.06 8.12 12.18 17.0 4.25 8.50 12.75 17.2 4.29 8.59 12.88 18.0 4.50 9.00 13.50 18.1 4.53 9.06 13.59 19.0 4.75 9.50 14.25 19.1 4.76 9.53 14.29 20.0 5.00 10.00 15.00 20.0 5.00 10.00 15.00 OFF, OFF, OFF, ON OFF, OFF, OFF, OFF 4.0 1.00 2.00 3.00 4.0 1.00 2.00 3.00 5.0 1.25 2.50 3.75 5.0 1.25 2.50 3.75 6.0 1.50 3.00 4.50 6.0 1.50 3.00 4.50 7.0 1.75 3.50 5.25 7.0 1.75 3.50 5.25 8.0 2.00 4.00 6.00 8.0 2.00 4.00 6.00 9.0 2.25 4.50 6.75 9.0 2.25 4.50 6.75 10.0 2.50 5.00 7.50 10.0 2.50 5.00 7.50 11.0 2.75 5.50 8.25 11.0 2.75 5.50 8.25 12.0 3.00 6.00 9.00 12.0 3.00 6.00 9.00 13.0 3.25 6.50 9.75 13.0 3.25 6.50 9.75 14.0 3.50 7.00 10.50 14.0 3.50 7.00 10.50 15.0 3.75 7.50 11.25 15.0 3.75 7.50 11.25 16.0 4.00 8.00 12.00 16.0 4.00 8.00 12.00 17.0 4.25 8.50 12.75 17.0 4.25 8.50 12.75 18.0 4.50 9.00 13.50 18.0 4.50 9.00 13.50 19.0 4.75 9.50 14.25 19.0 4.75 9.50 14.25 20.0 5.00 10.00 15.00 20.0 5.00 10.00 15.00 X X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X X X X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X 1 X X X X X X X 0 X X X X X X X 6

Table 5 Control Sequences INPUT EXPANDER WITH OR ANALOG INPUT - Provides 4, 8, 12, or 16 relay outputs controlled from a single BAS pulse-width modulated output or a single BAS analog voltage or current output. This control sequence allows a single BAS input to sequentially monitor up to 16 input devices. Single or Dual UMX control is available. SINGLE UMX CONTROL OFF, ON, OFF, ON OFF, OFF, ON, ON 4.0 1.00 2.00 3.00 6.0 1.50 3.00 4.50 1. 1 8.0 2.00 4.00 6.00 2.0 0 0 0 0 0 0 1 0 10.0 2.50 5.00 7.50 3.0 0 0 0 0 0 1 0 0 12.0 3.00 6.00 9.00 4.0 0 0 0 0 1 0 0 0 14.0 3.50 7.00 10.50 5.0 0 0 0 1 0 0 0 0 16.0 4.00 8.00 12.00 6.0 0 0 1 0 0 0 0 0 18.0 4.50 9.00 13.50 7.0 0 1 0 0 0 0 0 0 20.0 5.00 10.00 15.00 8.0 1 0 0 0 0 0 0 0 DUAL UMX CONTROL OFF, ON, OFF, ON OFF, OFF, ON, ON Level 2 4.0 1.00 2.00 3.00 5.0 1.25 2.50 3.75 1. 0 6.0 1.50 3.00 4.50 2. 0 7.0 1.75 3.50 5.25 3. 0 8.0 2.00 4.00 6.00 4. 0 9.0 2.25 4.50 6.75 5. 0 10.0 2.50 5.00 7.50 6. 0 11.0 2.75 5.50 8.25 7. 0 12.0 3.00 6.00 9.00 8. 0 13.0 3.25 6.50 9.75 9. 1 14.0 3.50 7.00 10.50 10.0 0 0 0 0 0 0 1 0 15.0 3.75 7.50 11.25 11.0 0 0 0 0 0 1 0 0 16.0 4.00 8.00 12.00 12.0 0 0 0 0 1 0 0 0 17.0 4.25 8.50 12.75 13.0 0 0 0 1 0 0 0 0 18.0 4.50 9.00 13.50 14.0 0 0 1 0 0 0 0 0 19.0 4.75 9.50 14.25 15.0 0 1 0 0 0 0 0 0 20.0 5.00 10.00 15.00 16.0 1 0 0 0 0 0 0 0 Level 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 7

Table 6 Control Sequences MULTI-STAGE SEQUENCER WITH OR ANALOG INPUT - Provides 4, 8, 12, or 16 sequenced relay stages from a single BAS pulse-width modulated output or a single BAS analog voltage or current output. Single or Dual UMX control is available. OFF, ON, OFF, OFF SINGLE UMX CONTROL OFF, OFF, ON, OFF 4.0 1.00 2.00 3.00 0.5 6.0 1.50 3.00 4.50 1. 1 8.0 2.00 4.00 6.00 2.0 0 0 0 0 0 0 1 1 10.0 2.50 5.00 7.50 3.0 0 0 0 0 0 1 1 1 12.0 3.00 6.00 9.00 4.0 0 0 0 0 1 1 1 1 14.0 3.50 7.00 10.50 5.0 0 0 0 1 1 1 1 1 16.0 4.00 8.00 12.00 6.0 0 0 1 1 1 1 1 1 18.0 4.50 9.00 13.50 7.0 0 1 1 1 1 1 1 1 20.0 5.00 10.00 15.00 8.0 DUAL UMX CONTROL OFF, ON, OFF, OFF OFF, OFF, ON, OFF Level 2 4.0 1.00 2.00 3.00 0.5 5.0 1.25 2.50 3.75 1. 0 6.0 1.50 3.00 4.50 2. 0 7.0 1.75 3.50 5.25 3. 0 8.0 2.00 4.00 6.00 4. 0 9.0 2.25 4.50 6.75 5. 0 10.0 2.50 5.00 7.50 6. 0 11.0 2.75 5.50 8.25 7. 0 12.0 3.00 6.00 9.00 8. 0 13.0 3.25 6.50 9.75 9. 1 14.0 3.50 7.00 10.50 10.0 0 0 0 0 0 0 1 1 15.0 3.75 7.50 11.25 11.0 0 0 0 0 0 1 1 1 16.0 4.00 8.00 12.00 12.0 0 0 0 0 1 1 1 1 17.0 4.25 8.50 12.75 13.0 0 0 0 1 1 1 1 1 18.0 4.50 9.00 13.50 14.0 0 0 1 1 1 1 1 1 19.0 4.75 9.50 14.25 15.0 0 1 1 1 1 1 1 1 20.0 5.00 10.00 15.00 16.0 Level 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 1 0 0 0 0 0 1 1 1 0 0 0 0 1 1 1 1 0 0 0 1 1 1 1 1 0 0 1 1 1 1 1 1 0 1 1 1 1 1 1 1 8

Table 7 Control Sequences ROOFTOP UNIT OR AHU CONTROLLER WITH OR ANALOG INPUT - Provides control of RTU or AHU fan, 2 cooling stages, 2 heating stages, and economizer from a single BAS pulse-width modulated output or a single BAS analog voltage or current output. Single or Dual UMX control is available. SINGLE UMX CONTROL ON, OFF, OFF, OFF OFF, ON, ON, OFF Output Description 4.0 1.00 2.00 3.00 1. 0 Off 6.0 1.50 3.00 4.50 2. 1 Fan 8.0 2.00 4.00 6.00 3.0 0 0 0 0 0 0 1 1 Cool 1, fan 10.0 2.50 5.00 7.50 4.0 0 0 0 0 0 1 1 1 Cool 2, cool 1, fan 12.0 3.00 6.00 9.00 5.0 0 0 0 0 1 0 0 1 Heat 1, fan 14.0 3.50 7.00 10.50 6.0 0 0 0 1 1 0 0 1 Heat 2, heat 1, fan 16.0 4.00 8.00 12.00 7.0 0 0 1 0 0 0 0 1 Economizer, fan 18.0 4.50 9.00 13.50 8.0 0 0 1 0 0 0 1 1 Economizer, cool 1, fan 20.0 5.00 10.00 15.00 9.0 0 0 1 0 0 1 1 1 Economizer, cool 2, cool 1, fan DUAL UMX CONTROL ON, OFF, OFF, OFF OFF, ON, ON, OFF Level 2 4.0 1.00 2.00 3.00 1.0 4.9 1.24 2.47 3.71 2.0 5.9 1.47 2.94 4.41 3.0 6.8 1.71 3.41 5.12 4.0 7.8 1.94 3.88 5.82 5.0 8.7 2.18 4.35 6.53 6.0 9.7 2.41 4.82 7.24 7.0 10.6 2.65 5.29 7.94 8.0 11.5 2.88 5.76 8.65 9.0 12.5 3.12 6.24 9.35 10. 0 13.4 3.35 6.71 10.06 11. 1 14.4 3.59 7.18 10.76 12.0 0 0 0 0 0 0 1 1 15.3 3.82 7.65 11.47 13.0 0 0 0 0 0 1 1 1 16.2 4.06 8.12 12.18 14.0 0 0 0 0 1 0 0 1 17.2 4.29 8.59 12.88 15.0 0 0 0 1 1 0 0 1 18.1 4.53 9.06 13.59 16.0 0 0 1 0 0 0 0 1 19.1 4.76 9.53 14.29 17.0 0 0 1 0 0 0 1 1 20.0 5.00 10.00 15.00 18.0 0 0 1 0 0 1 1 1 Level 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 1 0 0 0 0 0 1 1 1 0 0 0 0 1 0 0 1 0 0 0 1 1 0 0 1 0 0 1 0 0 0 0 1 0 0 1 0 0 0 1 1 0 0 1 0 0 1 1 1 9

Table 8 Control Sequences ROOFTOP UNIT OR AHU CONTROLLER WITH OR ANALOG INPUT - Provides control of RTU or AHU fan, 3 cooling stages, 3 heating stages, and economizer from a single BAS pulse-width modulated output or a single BAS analog voltage or current output. Single or Dual UMX control is available. SINGLE UMX CONTROL OFF, ON, ON, OFF OFF, ON, OFF, OFF Output Description 4.0 1.00 2.00 3.00 1. 0 Off 6.0 1.50 3.00 4.50 2. 1 Fan 8.0 2.00 4.00 6.00 3.0 0 0 0 0 0 0 1 1 Cool 1, fan 10.0 2.50 5.00 7.50 4.0 0 0 0 0 0 1 1 1 Cool 2, cool 1, fan 12.0 3.00 6.00 9.00 5.0 0 0 0 0 1 1 1 1 Cool 3, cool 2, cool 1, fan 14.0 3.50 7.00 10.50 6.0 0 0 0 1 0 0 0 1 Heat 1, fan 16.0 4.00 8.00 12.00 7.0 0 0 1 1 0 0 0 1 Heat 2, heat 1, fan 18.0 4.50 9.00 13.50 8.0 0 1 1 1 0 0 0 1 Heat 3, heat 2, heat 1, fan 20.0 5.00 10.00 15.00 9.0 1 0 0 0 0 0 0 1 Economizer, fan DUAL UMX CONTROL OFF, ON, ON, OFF OFF,ON,OFF,OFF Level 2 4.0 1.00 2.00 3.00 1.0 4.9 1.24 2.47 3.71 2.0 5.9 1.47 2.94 4.41 3.0 6.8 1.71 3.41 5.12 4.0 7.8 1.94 3.88 5.82 5.0 8.7 2.18 4.35 6.53 6.0 9.7 2.41 4.82 7.24 7.0 10.6 2.65 5.29 7.94 8.0 11.5 2.88 5.76 8.65 9.0 12.5 3.12 6.24 9.35 10. 0 13.4 3.35 6.71 10.06 11. 1 14.4 3.59 7.18 10.76 12.0 0 0 0 0 0 0 1 1 15.3 3.82 7.65 11.47 13.0 0 0 0 0 0 1 1 1 16.2 4.06 8.12 12.18 14.0 0 0 0 0 1 1 1 1 17.2 4.29 8.59 12.88 15.0 0 0 0 1 0 0 0 1 18.1 4.53 9.06 13.59 16.0 0 0 1 1 0 0 0 1 19.1 4.76 9.53 14.29 17.0 0 1 1 1 0 0 1 1 20.0 5.00 10.00 15.00 18.0 1 0 0 0 0 0 0 1 Level 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 1 0 0 0 0 0 1 1 1 0 0 0 0 1 1 1 1 0 0 0 1 0 0 0 1 0 0 1 1 0 0 0 1 0 1 1 1 0 0 0 1 1 0 0 0 0 0 0 1 10

Table 9 Control Sequences ROOFTOP UNIT OR AHU CONTROLLER WITH OR ANALOG INPUT Provides control of RTU or AHU fan, 3 cooling stages, 3 heating stages, and economizer from a single BAS pulse-width modulated output or a single BAS analog voltage or current output. Single or Dual UMX control is available. SINGLE UMX CONTROL OFF, ON, ON, ON OFF, ON, OFF, ON Output Description 4.0 1.00 2.00 3.00 0 0 0 0 1 1 1 1 Heat 3, heat 2, heat 1, fan 6.0 1.50 3.00 4.50 1.0 0 0 0 0 1 1 1 1 Heat 3, heat 2, heat 1, fan 8.0 2.00 4.00 6.00 2.0 0 0 0 0 0 1 1 1 Heat 2, heat 1, fan 10.0 2.50 5.00 7.50 3.0 0 0 0 0 0 0 1 1 Heat 1, fan 12.0 3.00 6.00 9.00 4. 0 Off 14.0 3.50 7.00 10.50 5.0 0 0 0 1 0 0 0 1 Economizer, fan 16.0 4.00 8.00 12.00 6.0 0 0 1 0 0 0 0 1 Cool 1, fan 18.0 4.50 9.00 13.50 7.0 0 1 1 0 0 0 0 1 Cool 2, cool 1, fan 20.0 5.00 10.00 15.00 8.0 1 1 1 0 0 0 0 1 Cool 3, cool 2, cool 1, fan DUAL UMX CONTROL OFF, ON, ON, ON OFF, ON, OFF, ON Level 2 4.0 1.00 2.00 3.00 4.9 1.24 2.47 3.71 1.0 5.9 1.47 2.94 4.41 2.0 6.8 1.71 3.41 5.12 3.0 7.8 1.94 3.88 5.82 4.0 8.7 2.18 4.35 6.53 5.0 9.7 2.41 4.82 7.24 6.0 10.6 2.65 5.29 7.94 7.0 11.5 2.88 5.76 8.65 8.0 12.5 3.12 6.24 9.35 0 0 0 0 1 1 1 1 13.4 3.35 6.71 10.06 9.0 0 0 0 0 1 1 1 1 14.4 3.59 7.18 10.76 10.0 0 0 0 0 0 1 1 1 15.3 3.82 7.65 11.47 11.0 0 0 0 0 0 0 1 1 16.2 4.06 8.12 12.18 12. 0 17.2 4.29 8.59 12.88 13.0 0 0 0 1 0 0 0 1 18.1 4.53 9.06 13.59 14.0 0 0 1 0 0 0 0 1 19.1 4.76 9.53 14.29 15.0 0 1 1 0 0 0 0 1 20.0 5.00 10.00 15.00 16.0 1 1 1 0 0 0 0 1 Level 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 0 1 1 1 0 0 0 0 0 0 1 1 0 0 0 1 0 0 0 1 0 0 1 0 0 0 0 1 0 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 11

FEEDBACK The has two feedback voltage output circuits labeled FBK1 (relay outputs 1-4) and FBK2 (relay outputs 5-8). The has one feedback voltage output circuit labeled FBK1 (relay outputs 1-4). When a relay output is energized, the following voltage is added to the feedback output. FBK1 - Feedback Circuit #1 Relays 1,2,3,4 OFF 1.0V Relay 1 ON ADD 0.27V Relay 2 ON ADD 0.53V Relay 3 ON ADD 1.07V Relay 4 ON ADD 2.13V FBK2 - Feedback Circuit #2 Relays 5,6,7,8 OFF 1.0V Relay 5 ON ADD 0.27V Relay 6 ON ADD 0.53V Relay 7 ON ADD 1.07V Relay 8 ON ADD 2.13V Example: If outputs 1 and 3 are energized and 2 and 4 are de-energized, the voltage output on FBK1 will be 2.34V (1V + 0.27V +1.07V = 2.34V). The same would be true for FBK2 if relay outputs 5 and 7 were energized, and 6 and 8 were de-energized. FEEDBACK DECODING FLOWCHART This flowchart represents the program logic that allows an automation system to determine the state of each UMX output. The logic shown decodes the states of outputs 1-4 using the FBK1 signal. Outputs 5-8 are decoded exactly the same way using the FBK2 signal. 1. In your program, create the variables FBK1, OUT1, OUT2, OUT3, OUT4. The FBK variables must be able to hold analog values. The OUT variables can be binary (OFF/ON) variables. 2. Read the value of the UMX FBK1 signal into the FBK1 variable. SET OUT4 (OUT8) TO OFF. SET OUT3 (OUT7) TO OFF. NO NO START IS FBK1 (FBK2) GREATER THAN 3.00 V? IS FBK1 (FBK2) GREATER THAN 1.93 V? YES YES SET OUT4 (OUT8) TO ON. SET OUT3 (OUT7) TO ON. SUBTRACT 2.13 FROM FBK VALUE SUBTRACT 1.07 FROM FBK VALUE 3. Then, beginning at START, work your way down the flow chart to determine the status of each output relay. SET OUT2 (OUT6) TO OFF. NO IS FBK1 (FBK2) GREATER THAN 1.40 V? YES SET OUT2 (OUT6) TO ON. SUBTRACT 0.53 FROM FBK VALUE SET OUT1 (OUT5) TO OFF. NO IS FBK1 (FBK2) GREATER THAN 1.13V? YES SET OUT1 (OUT5) TO ON. FINISHED Model Model ORDERING INFORMATION 4 Stage Multiplexer with HOA Switches 8 Stage Multiplexer with HOA Switches KELE & ASSOCIATES P O Box 34817 Memphis, TN 38184 901-382-4300 FAX 901-372-2531