Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures

Similar documents
Natural Convection Heat Loss from A Partly Open Cubic Enclosure Timothy N Anderson 1,a * and Stuart E Norris 2,b

Natural Convection Heat Transfer inside a Narrow Triangular Enclosure with Rectangular Staggered Finned Base Plate: An Empirical Correlation

HEAT LOSS CHARACTERISTICS OF A ROOF INTEGRATED SOLAR MICRO-CONCENTRATING COLLECTOR

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

Effect of an adiabatic fin on natural convection heat transfer in a triangular enclosure

Performance Assessment of PV/T Air Collector by Using CFD

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

Transient Heat Transfer Experiment. ME 331 Introduction to Heat Transfer. June 1 st, 2017

Heat Loss from Cavity Receiver for Solar Micro- Concentrating Collector

Natural Convection in Parabolic Enclosure Heated from Below

Solar Flat Plate Thermal Collector

EXPERIMENTAL INVESTIGATION OF DIFFERENT TRACKING MODES OF THE PARABOLIC TROUGH COLLECTOR

THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE

NUMERICAL ANALYSIS OF NATURAL CONVECTION IN A PRISMATIC ENCLOSURE

ENHANCEMENT OF THE HEAT TRANSFER RATE IN FREE CONVECTION SOLAR AIR HEATER USING PIN SHAPED ARTIFICIAL ROUGHNESS ON ABSORBER PLATE

Natural convective heat transfer in trapezoidal enclosure of box-type solar cooker

Chapter 3 NATURAL CONVECTION

Experimental Analysis for Natural Convection Heat Transfer through Vertical Cylinder

An Evacuated PV/Thermal Hybrid Collector with the Tube/XCPC design

Construction and performance analysis of a three dimensional compound parabolic concentrator for a spherical absorber

Table of Contents. Foreword... xiii. Preface... xv

Natural Convection Inside a Rectangular Enclosure with Two Discrete Heat Sources Placed on Its Bottom Wall

NUMERICAL ANALYSIS OF NATURAL CONVECTION IN A RIGHT- ANGLED TRIANGULAR ENCLOSURE

Experimental Study of Heat Transfer Enhancement in a Tilted Semi-Cylindrical Cavity with Triangular Type of Vortex Generator in Various Arrangements.

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

AN EXPERIMENTAL STUDY OF MIXED CONVECTION HEAT TRANSFER IN AN INCLINED RECTANGULAR DUCT EXPOSED TO UNIFORM HEAT FLUX FROM UPPER SURFACE

Chapter 9 NATURAL CONVECTION

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

NUMERICAL STUDY OF HEAT TRANSFER IN A FLAT PLAT THERMAL SOLAR COLLECTOR WITH PARTITIONS ATTACHED TO ITS GLAZING. Adel LAARABA.

True/False. Circle the correct answer. (1pt each, 7pts total) 3. Radiation doesn t occur in materials that are transparent such as gases.

Journal of Engineering Research and Studies E-ISSN

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

The 5 th TSME International Conference on Mechanical Engineering th December 2014, The Empress, Chiang Mai

Simulation of a linear Fresnel solar collector concentrator

EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF THE HYBRID SOLAR PVT COLLECTOR UNDER DIFFERENT WEATHER CONDITION

Numerical Investigation of Conjugate Natural Convection Heat Transfer from Discrete Heat Sources in Rectangular Enclosure

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

Entropy 2011, 13, ; doi: /e OPEN ACCESS. Entropy Generation at Natural Convection in an Inclined Rectangular Cavity

Thermal modelling of low concentrator photovoltaic systems

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Enhancement of Natural Convection Heat Transfer within Closed Enclosure Using Parallel Fins F. A. Gdhaidh, K. Hussain, H. S. Qi

LAMINAR NATURAL CONVECTION IN VERTICAL 2D GLAZING CAVITIES

Chapter 1 INTRODUCTION AND BASIC CONCEPTS

Experimental Analysis of Natural Convective Heat Transfer Performance From Rectangular Fin Array with Perforations

CHME 302 CHEMICAL ENGINEERING LABOATORY-I EXPERIMENT 302-V FREE AND FORCED CONVECTION

THERMAL PERFORMANCE EVALUATION OF AN INNOVATIVE DOUBLE GLAZING WINDOW

UNIT II CONVECTION HEAT TRANSFER

Lecture 28. Key words: Heat transfer, conduction, convection, radiation, furnace, heat transfer coefficient

Computational Modeling of a Solar Thermoelectric Generator

UNIT FOUR SOLAR COLLECTORS

Study of Temperature Distribution Along the Fin Length

Deposited on: 01 September 2011

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

Numerical Study of Convective Heat Transfer for Flat Unglazed Transpired Solar Collectors

Numerical simulation of heat transfer and fluid flow in a flat plate solar collector with TIM and ventilation channel

A Demonstration Unit to Enhance Heat Transfer Lectures on Natural and Forced Convection

MERGING OF SHEET PLUMES IN TURBULENT CONVECTION

Natural Convection Systems

Study of a new concept of photovoltaic-thermal hybrid collector

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

Supplemental Information. Storage and Recycling of Interfacial. Solar Steam Enthalpy

Influence of Heat Transfer Process in Porous Media with Air Cavity- A CFD Analysis

Thermal Unit Operation (ChEg3113)

Chapter 10: Steady Heat Conduction

Experimental and Theoretical Evaluation of the Overall Heat Loss Coefficient of a Vacuum Tube Solar Collector

ANALYSIS OF FLAT PLATE PHOTOVOLTAIC-THERMAL (PVT) MODELS

Natural Convection in Porous Triangular Enclosure with a Circular Obstacle in Presence of Heat Generation

PROBLEM Node 5: ( ) ( ) ( ) ( )

NUMERICAL STUDY OF MIXED CONVECTION AND THERMAL RADIATION IN A SQUARE CAVITY WITH AN INSIDE INCLINED HEATER

Experimental Evaluation of Natural Convection Heat Transfer for Rough Surface

Numerical investigation of the buoyancy-induced flow field and heat transfer inside solar chimneys

Introduction to Heat and Mass Transfer. Week 14

Experimental Analysis of Rectangular Fin Arrays with Continuous Fin and Interrupted Fins Using Natural and Forced Convection

Chapter 7: Natural Convection

Analysis of Thermoelectric Generator Performance by Use of Simulations and Experiments

Available online at ScienceDirect. Energy Procedia 57 (2014 ) ISES Solar World Congress

Free and Forced Convection Heat Transfer Characteristics in an Opened Box with Parallel Heated Plates

External Forced Convection :

Sigma J Eng & Nat Sci 36 (1), 2018, Sigma Journal of Engineering and Natural Sciences Sigma Mühendislik ve Fen Bilimleri Dergisi

ECE309 INTRODUCTION TO THERMODYNAMICS & HEAT TRANSFER. 10 August 2005

Heat Transfer Analysis of a Between-Panes Venetian Blind Using Effective Longwave Radiative Properties

Chapter 1: 20, 23, 35, 41, 68, 71, 76, 77, 80, 85, 90, 101, 103 and 104.

11. Advanced Radiation

NATURAL CONVECTION AND RADIATION IN CIRCULAR AND ARC CAVITY

c. The Grashof number is the ratio of buoyant forces to viscous forces acting on a fluid.

Optics and Heat Transfer for Asymmetric Compound Parabolic Photovoltaic Concentrators for Building Integrated Photovoltaics

Numerical Study of Conjugate Natural Convection Heat Transfer Using One Phase Liquid Cooling

INTERNATIONAL JOURNAL OF ADVANCED RESEARCH IN ENGINEERING AND TECHNOLOGY (IJARET)

NATURAL CONVECTION AIR FLOW IN VERTICAL UPRIGHT-ANGLED TRIANGULAR CAVITIES UNDER REALISTIC THERMAL BOUNDARY CONDITIONS

CFD MODELLING OF CONVECTIVE HEAT TRANSFER FROM A WINDOW WITH ADJACENT VENETIAN BLINDS

Thermal Analysis of Solar Collectors

4.1 Derivation and Boundary Conditions for Non-Nipped Interfaces

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

International Journal of Engineering Research and General Science Volume 3, Issue 6, November-December, 2015 ISSN

Tick the box next to those resources for which the Sun is also the source of energy.

Experimental Analysis of Wire Sandwiched Micro Heat Pipes

Pin Fin Lab Report Example. Names. ME331 Lab

The digital copy of this thesis is protected by the Copyright Act 1994 (New Zealand).

Autumn 2005 THERMODYNAMICS. Time: 3 Hours

Transcription:

Peer Reviewed Paper Piratheepan Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures Abstract M Piratheepan 1, T N Anderson 1, S Saiful 1 1 Auckland University of Technology, Auckland, New Zealand E-mail:timothy.anderson@aut.ac.nz The use of building integrated solar concentrators is an area of developing interest within the field of energy-efficient building technology. One way of achieving such a device could be through the use of a flat static reflector used in conjunction with a photovoltaic/thermal absorber and glazing, thus forming a triangular enclosure similar to a single sided V-trough enclosure. Such systems may be well suited to adoption in façade applications. However, in order to precisely predict the performance of such building integrated façade collectors, it is crucial to understand the heat losses from the absorber. Unlike a flat plate collector, the glazing is not parallel to the absorber plate hence we need to develop a relationship that describes the thermal losses through the vertical glazed cover. As the air between the collector and the glass is isolated from the atmosphere, the thermal loss from the absorber to the glass cover will be due to natural convection and radiation. The radiation heat transfer can be readily determined using view factors, however there is no relationship in the literature to describe the natural convection heat transfer in triangular enclosures similar to the one illustrated. In this study, a relationship to describe the natural convection heat transfer in such triangular enclosures was experimentally determined. The relationship shows that the heat transfer, expressed in terms on the Nusselt number, is strongly dependent on the Rayleigh number and can be expressed by a relationship of the form of Nu = ara b. 1. Introduction In an urban environment, with limited supply of roof space, low concentrating façade integration of solar collectors opens an innovative way of harnessing solar energy and is an area of developing interest within the sustainable building practices. One way of achieving such a device could be through the use of static reflectors used in conjunction with glazed photovoltaic/thermal absorbers. Systems of a similar premise to this with photovoltaic absorbers have been discussed by researchers in the UK and Ireland (Zacharopoulos, et al. 2000, Mallick, et al. 2004), Sweden (Brogren 2004) (Brogren and Karlsson 2002), (Gajbert 2008) and Brazil (Zanesco and Lorenzo 2002), with respect to increasing their electrical output. Interestingly, although some of the studies (Brogren and Karlsson 2002), (Gajbert 2008) have used water to cool the absorber in order to improve their electrical performance, none of these studies has taken steps to predict their precise thermal performance by analysing the heat balance of the absorber plate. In an ideal scenario the majority of the energy that reaches the absorber plate should be absorbed and utilised. One promising way of achieving this is by using photovoltaic/thermal absorber plates that can deliver both thermal and electrical energy simultaneously. Here the thermal energy can be carried away by the transport medium as useful energy.

However, thermal losses from the collector to the environment are inevitable. Minimizing the thermal losses and knowing the parameters governing the heat losses will help understand the operation of the collector from the design phase. Previously, (Piratheepan and Anderson, 2014) proposed a design for a low concentration ratio façade-integrated photovoltaic/thermal concentrator which when glazed would form a triangular enclosure filled with air, as shown in Figure 1. Facade Reflector Glass cover Absorber Figure 1 Façade Integrated Concentrator Of the available literature relating to convection heat transfer coefficients in triangular enclosures, the majority have been aimed at attic shaped enclosures. In a recent study (Anderson et al, 2010) examined an attic shaped enclosure with a heated inclined surface and suggested that a correlation given by (Ridouane and Campo, 2005) could be used in the determination of the convective heat transfer coefficient. In another study, (Anderson, 2013) found a relationship between Nusselt number and Rayleigh number in the form of Nu=aRa b that described the heat loss in enclosed V-trough concentrators operating at a range of orientations. However, there are no existing relationships to describe the convection heat transfer between the absorber and glazing in an enclosure such as that shown in Figure 1. In light of this lack of experimental data relating to tilted right triangular enclosures with a heated base, this study experimentally evaluates the convection heat transfer coefficient in the proposed collector, in order to facilitate accurate prediction of the collector s performance. 2. Experimental Method In order to determine the convective heat loss from the absorber, an analogue of the collector was fabricated, where a heating element was used to represent the absorber plate in the proposed collector. It was decided to build a 1.2m long enclosure with cross sectional dimensions of 200mm x 600mm as shown in Figure 2. To achieve a temperature gradient between the cold plate and the hotplate, the hotplate was made with flexible resistance heating wires attached to a 2mm polished aluminium plate. Aluminium plate was used to ensure a uniform temperature along the heater plate (owing to its high thermal conductivity) and also for it s low emissivity, to reduce radiation heat transfer.

Insulation Reflector Rear Bottom End Cold plate Heating element (Hotplate) Figure 2: Module to be used for the heat transfer experiment In an effort to minimize the heat losses through the rear and sides of the heater, the rear side of the heater and the reflector plate were filled with 100mm thick mineral wool fibre with nominal R-value of 2.8 and enclosed by 18mm plywood. The ends were fabricated with 18mm plywood. The inclined reflector module was constructed with 2mm alumium plate to minimize thermal radiation from it (low emissivity). The vertical façade (cold plate) was built with 2mm aluminium sheet in order to keep the temperature uniform over the entire area. Furthermore, this surface was cooled by two fans to ensure the majority of the heat from the enclousure was taken away through this surface. Finally the edges of the whole enclosure were sealed with high temperature aluminium duct tape to reduce any undesirable heat losses by air leakage. Now, in order to vary the Rayleigh number, either the temperature difference between the plates or the characteristic length has to be varied. To vary the temperature difference, the power supplied to the electrical heater was varied by a variable transformer (Variac) and the amount of power supplied was measured by a single-phase MS6115 power meter. The mean temperature of the hotplate was measured by six T-type thermocouples (±0.3K) attached uniformly along the length of the hotplate. Nine more T-type thermocouples were used over the surface of the cold plate to measure its mean temperature. The ambient temperature was measured by another T-type thermocouple. Subsequently all of these thermocouples were connected to two Picolog TC-08 data loggers connected to a computer through a USB interface. The schematic diagram of the experimental configuration is illustrated in Figure 3. The difference between hot and cold plate temperature (ΔT) was calculated using the mean hot and cold plate temperatures. Thermocouples Heater Fan Data Data Variac Power meter Grid Figure 3 Schematic of the experimental setup

The series of thermocouple readings were used to identify the region of steady state. Here the steady state condition was determined by taking the region where the difference between the mean temperature of the heater and the cooled surface was not fluctuating more than 0.6K over a 60 minute time period. 3. Analysis From the experimental result, the overall heat transfer coefficient (U) can be derived from Newton s cooling law. Here, the heat transfer coefficient between two plates under steady state conditions can be given as a function of the input electrical power (Q e ), the temperature difference between the plates (ΔT) and the area of the hotplate (A h ) as shown in Equation 1. U = Q e /(A h ΔT) (1) This provides an approximate indication of the convective heat transfer coefficient inside the enclosure. In order to obtain the heat that is being transferred by the convection (Q convection ) however, a complete heat balance should be undertaken. Thus, the Q convection can be expressed in terms of total electrical energy input and the other means of heat losses as given by Equation 2. Q convection = Q e Q conduction Q radiation (2) Here Q conduction is the sum of rear, base and end conduction losses while the Q radiation is the amount of heat loss by radiation. The rear, bottom and end heat losses by conduction (Q conduction ) can be calculated by applying Fourier s law over the areas of interest (A i ) across the thickness (L) where (k) is the thermal conductivity of the wall and temperature difference across the wall is (T i -T a ) as given in Equation 3. In this T a is the ambient air temperature and in the case of rear and bottom heat losses T i was the temperature of the hot plate. However, the end loss was calculated using the bulk temperature of the air inside the enclosure as T i. Q conduction = ka I(T i T a ) (3) L Now, the radiation heat transfer between the hot and cold plate (Q radiation ) is another portion of the thermal losses from the hotplate. However it was assumed to be negligible in this case given that both hot and cold plate were fabricated using low emissivity aluminium plate (ε p 0.06). Furthermore, as the inclined reflector surface of the enclosure was heavily insulated, it can be assumed to be an adiabatic surface under steady state conditions and the radiation losses can be discounted. To confirm the decision to discount the radiation from the heat balance calculation, the enclosure was assumed to be a two-surface enclosure consisting of the aluminium heater and the cold plate. Hence the expression of the Q radiation can be written in terms of area of the hotplate (A h ), area of the cold plate (A c ), both made up of aluminium with the emissivity of ε p and the view factor (F) (Cengel 2007), as given by Equation 4. Q radiation = 4 σ(t h Tc 4 ) 1 ε p εp 1 + 1 A h Ac + 1 A h F Here T h and T c are hot and cold plate temperatures. The analysis found that Q radiation accounted for less than 4% of the heat transferred by convection and hence it is reasonable to assume it to be negligible. Based on this assumption, Equation 2 can be reduced to Equation 5 without the radiation component. Q convection = Q e Q conduction (5) (4)

By combining Equations 1 and 5, the convection heat transfer coefficient (h c ) can be expressed in terms of Q convection, area of the hotplate (A h ) and the temperature difference (ΔT) between the hot and cold plate as given in Equation 6. h c = (Q e Q conduction )/(A h ΔT) (6) 4. Results In order to determine the natural convection heat transfer coefficient of the proposed enclosure, the heat supplied to the hotplate was varied. By changing the heater power, the mean temperature of the hotplate was varied from 48 C to 112 C. Using the recorded temperature difference and the amount of heat supplied, it was possible to calculate the convection heat transfer coefficient from Equation 6. Figure 5 indicates that there is an increasing trend in heat transfer coefficient as the temperature difference increases. This matches with the characteristics of the natural convection flows. As the temperature difference increases, the degree of turbulence in the fluid increases, and hence the heat transfer increases (Cengel 2007). 10 8 h c (W/m 2 K 6 4 2 0 0 20 40 60 80 100 ΔT (K) Figure 4 Temperature difference v heat transfer coefficient Although the results given in Figure 4 relate the temperature gradient to the heat transfer coefficient, this relationship cannot be used directly to find the heat transfer coefficient in different sized enclosures. Therefore it was decided to find a relationship between the dimensionless parameters (Nusselt number and Rayleigh number) so that it can be used to obtain the heat transfer coefficient of geometrically similar enclosures of various sizes. In achieving this, the air in the enclosure was assumed to be a real fluid and its thermophysical properties were calculated at the bulk enclosure temperature (the average temperature of hot and cold plate). These properties were then used to find the Rayleigh and Nusselt number, where the temperature change from 48 C to 112 C, corresponded a Rayleigh number change from 5 x 10 7 to 1 x 10 9 taking the characteristic length to be the height of the cold plate. From Figure 5, it can be seen that there exists a relationship between the Nusselt number and Rayleigh number that can be expressed in the general form given in Equation 7. Nu = 0.11Ra 0.35 (7)

This is a typical relationship of the correlations that exist for turbulent natural convection in enclosures, with an exponential value close to 1/3 often being used in enclosures with isothermal surfaces (Cengel 2007). Nusselt Number 200 160 120 80 40 0 0.0E+00 5.0E+08 1.0E+09 Rayleigh Number 1.5E+09 Figure 5 Rayleigh number v Nusselt number 5. Conclusion The triangular shaped enclosure proposed in this study offers a simple solution to increase the solar radiation on the absorber plate in a façade integrated solar system. In this way, the electrical/thermal output from such façade collector system can be improved. However, in order to precisely predict the performance of the system, it is essential to understand the heat losses from it. In light of the unavailability of the correlations relating the convection heat transfer coefficient in proposed façade enclosed system, this study shows that the natural convection heat loss can be predicted by the relationship Nu = 0.11Ra 0.35 for the Rayleigh number range of 5 x 10 7 to 1 x 10 9. Furthermore, this correlation can be applied for geometrically similar enclosures with different dimensions, given that the Rayleigh number is within the range of experimental values. The empirical equation suggests this simple relationship is a good representation of the heat transfer coefficient in the triangular enclosures and is similar to existing relationships for enclosures in general. 6. References Anderson, T., Duke, M., and Carson, J. 2010, Experimental determination of natural convection heat transfer coefficients in an attic shaped enclosure International Communications in Heat and Mass Transfer, Volume37, p360-363. Anderson, T. 2013 Natural convection heat transfer in V-trough solar concentrators Solar Energy, Volume 95, p224-228. Brogren, M. 2004 Optical efficiency of low-concentrating solar energy systems with parabolic reflectors, Doctoral thesis, p98-107. Brogren, M., and B. Karlsson. 2002 Low-concentrating water-cooled PV-thermal hybrid systems for high latitudes Photovoltaic Specialists Conference, p1733-1736. Cengel,Y. 2007 Heat & mass transfer: a practical approach Tata McGraw-Hill Education, p503-504.

Gajbert, H. 2008 Solar thermal energy systems for building integration Doctoral thesis, p163-173. Iyican, L., Witte,L and Bayazitoglu Y. 1980, An experimental study of natural convection in trapezoidal enclosures Journal of Heat Transfer, Volume 102, p648-653. Mallick, T., Eames, P., Hyde,T., and Norton B 2004 The design and experimental characterisation of an asymmetric compound parabolic photovoltaic concentrator for building facade integration in the UK. Solar Energy, Volume 77, p319-327. Piratheepan,M., Anderson,T., 2014. Experimental evaluation of low concentration collectors for façade applications Proceeding of Solar 2014 Conference & Exihibition. Ram,K., Anandalakshmi,R., and Tanmay,B. 2010 Bejan s heatline analysis of natural convection in right-angled triangular enclosures: Effects of aspect-ratio and thermal boundary conditions International Journal of Thermal Sciences Volume 49, p1576-1592. Ridouane, E., and Campo,A. 2005 Experimental-based correlations for the characterization of free convection of air inside isosceles triangular cavities with variable apex angles. Experimental Heat Transfer Volume 18, p81-86. Zacharopoulos,A.,Eames,P.,McLarnon,D. and Norton,B. 2000 Linear dielectric nonimaging concentrating covers for PV integrated building facades. Solar Energy Volume 68, p439-452. Zanesco, I. and and Lorenzo, E. 2002 Optimisation of an asymmetric static concentrator: the PEC 44D. Progress in Photovoltaics: Research and Applications, Volume 10, p361-376.