INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

Similar documents
Chapter-2 Direct Measurement Indirect Measurement Method of linear measurement Taping corrections Optical measurement Tachometry EDM Measurement

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

CIV : THEODOLITE ADJUSTMENT

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

Cleveland State University

取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02

Measurement of Distance and Elevation Equipment and Procedures

Digital Land Surveying And Mapping(DLS&M) Dr. Jayanta Kumar Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee

~.LIETZ ~. LI ETZ INSTRUCTION MANUAL DOUBLE CENTER THEODOLITE TM-20C THE LIETZ COMPANY E. Del Arno Blvd. Carson, Ca (213)

Leveling. 3.1 Definitions

Automatic Level NP-732

GEOMATICS ENGINEERING

Islamic University of Gaza Civil Engineering Department Surveying II ECIV 2332

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

Carlson CR Robotic/Reflectorless Total Station

22X Builder s Transit Level Model No Instruction Manual

LT8-300LTU Owner s Guide

Fig. 1. instrument is in the case

22X Builder s Level Model No Instruction Manual

SURVEYING 1 CE 215 CHAPTER -3- LEVEL AND LEVELING

DWT-10 Instruction Manual

2-7x32. Instruction manual

DETERMINATION OF AREA OF POLYGON BY CHAIN AND CROSS STAFF SURVEY 1. AIM:

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

GT-510/510L series Instruction Manual

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

SURVEYING 1 CE 215 CHAPTER -3- LEVEL AND LEVELING

NcSTAR SHOOTER II SERIES SCOPE

MARINE BINOCULARS ZHUMELL 7X50 MARINE BINOCULARS WITH COMPASS AND RETICLE

C A S S I N I TRACKER

GY 301: Geomorphology Lab 5: Total Station Mapping Project

SURVEYING INSTRUMENTS DT7C DT20C. Electronic Digital Theodolite OPERATOR'S MANUAL

EE 1/3.5х14 U EE 1/3.5х14 U

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

Measurement of Horizontal Distances. the distance between two points means the horizontal distance

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

Surveying Prof. Bharat Lohani Indian Institute of Technology, Kanpur. Module - 5 Lecture - 3 Theodolites and Total Stations

PLI Support Guide: Robotic Total Station Field Calibration

BINOCULAR. 50 mm Tactical Binocular Manual HD R/T

Cleveland State University

Directions for use

UNIT-4 THEODOLITE SURVEYING

Fig. 8.1 illustrates the three measurements. air medium A. ray 1. air medium A. ray 2. air medium A. ray 3. Fig For Examiner s Use

National 3 Waves and Radiation

Surveying Prof. Bharat Lohani Indian Institute of Technology, Kanpur. Module 5 Lecture 1

COPYRIGHTED MATERIAL INTRODUCTION CHAPTER 1

5-25x56 PMII PSR With Double Turn

Surveying Prof. Bharat Lohani Department of Civil Engineering Indian Institute of Technology, Kanpur. Module - 3 Lecture - 4 Linear Measurements

Pulse Laser Station NPL-302 Series

The 36mm Solo R/T Tactical monocular delivers bright images, is compact, easy to handle, and designed for hard use.

Basic Operation Adjust the eyecup

H050 E 97.1.DF.2. Automatic Levels AS-2 / AS-2C

Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

PULSE TOTAL STATION GPT-3000(L)N SERIES

1 YEAR LIMITED WARRANTY TELESCOPES

AL 22 / 26 Classic Инструкция по использованию FIN RUS / / Rev.01.07

The 50mm Viper R/T binocular is equipped with the Vortex R/T Ranging reticle, designed to assist the user in calculating distances.

SOLO R/T TACTICAL MONOCULAR

Welcome to purchase and use our products and thank you for your confidence in our company s products!

Interferometer for Squareness measurement

CE 271 Spring Survey Camp

Climate & Earth System Science. Introduction to Meteorology & Climate. Chapter 05 SOME OBSERVING INSTRUMENTS. Instrument Enclosure.

Physics 313: Laboratory 8 - Polarization of Light Electric Fields

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

COPYRIGHTED MATERIAL INTRODUCTION CHAPTER 1

Spotting Scope Instruction Manual

LEAPERS, INC. RED/GREEN DOTS

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands

CASSINI CQR-120 OPERATING INSTRUCTIONS

model SKT05 SKT05L Toll Free: (855) IMPORTANT: Read Before Using IMPORTANT Lire avant usage IMPORTANTE: Leer antes de usar

ZENITHSTAR 61 APO. Owner s Manual ver

0.4 s 0.8 s 1.5 s. 2.5 s. 2. A beam of light from a ray box spreads out as shown in the diagram and strikes a plane mirror.

x Builders Level Service Manual

Name: Number: Class: Date: What is light? 1. What is the name for all these types of light? 2. What type of light can humans see?

What is the maximum distance I can have the remote sensors from the display?

ZFK 4 X 25. Description and Utilization Instructions

2. OPERATIONAL CONDITIONS

10.3 Vertical reticle

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

NEW STANDARD SEXTANT OF THE U. S. NAVY

5-25x56 PMII PSR Illuminated with Double Turn

RP-100 TELESCOPE Instruction Manual

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Physics LESSON PLAN PERFORMANCE OBJECTIVE(S): STUDENTS WILL BE ABLE TO:

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W

Experiment #5: Cauchy s Formula

AGES CF600PM. 50 mm Telescope w/ AZ Pan Tilt Mount Instruction Manual. WARNING! SUN HAZARD: Never look directly at the sun with this device.

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

STONEX ELECTRONIC THEODOLITE STT SERIES. Instruction Manual

Physics 476LW Advanced Physics Laboratory Michelson Interferometer

PRIMARY CONTROL SURVEYS

-I g in y e SURVEYING-I rv u S

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

CONTENT FORWORDS... 1 FEATURES... 5 PRECAUTIONS BRIEF INTRODUCTION... 7

The Accuracy of Electronic Distance Meters over Short Distances

Transcription:

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305) Linear Measurements Sr Dr. Tan Liat Choon Email: tanliatchoon@gmail.com Mobile: 016-4975551 1

EDM, TOTAL STATION, PRISM AND POLE 2

ELECTROMAGNETIC DISTANCE MEASUREMENT (EDM) A major advance in surveying instrument occurred approximately 60 years ago with the development of electronic distance measurement (EDM) instruments. These devices measure lengths by indirectly determining the number of full and partial waves of transmitted, electromagnetic energy required in traveling between the two ends of a line. In practice, the energy is transmitted from one end of the line to the other and returned to the starting points 3

Definition ELECTROMAGNETIC DISTANCE MEASUREMENT (EDM) The electronic distance measurement instrument (EDM) is a relatively new development in the field of surveying. The instrument sends out a beam of light or high frequency microwaves from one end of line to be measured, and directs it towards the far end of the line. A reflector or transmitter receiver at the far end reflects the light or microwaves back to the instrument where they are analyzed electronically to give the distance between the two points (Francis, 1982) 4

ELECTROMAGNETIC DISTANCE MEASUREMENT (EDM) EDM instruments are available to measure distance using light and radio waves. The distance is calculated either from the time difference between a transmitted pulse and a return pulse or the phase difference between a transmitted and a reflected beam of radiation 5

ELECTROMAGNETIC DISTANCE Components of EDM MEASUREMENT (EDM) Light source For transferring the electromagnetic waves Light Modulation Change the light to Electromagnetic waves Phase Difference system Mini PC or Calculator 6

ELECTROMAGNETIC DISTANCE MEASUREMENT (EDM) Electromagnetic distance measuring equipment use three different wavelength bands: Microwave systems Range up to 150 km Wavelength 3 cm Unaffected by visibility Light wave systems Range up to 5 km Visible light, lasers 3-distance reduced by visibility Infra red systems 1-Range up to 3 km 2-limited to line of sight 3-limited by rain, fog, and other airborne particles EDM and electronic theodolite The accuracy of the measurement varies from type to type but is usually in the range from ±(1.0 mm + 1.0 ppm) to ±(10.0 mm + 5 ppm). EDM and electronic theodolite 7

ELECTROMAGNETIC DISTANCE MEASUREMENT (EDM) 8

TOTAL STATION A Total Station integrates the functions of a theodolite for measuring angles, an EDM for measuring distances, digital data and information recording. Examples of Total Stations are the Nikon DTM 801, Topcon and Geodimeter 400 series Examples of usage General purpose angle and distance measurements. Provision of control surveys, Contour and detail mapping, setting out and construction work Factors which influence the use of Total Stations A clear line of sight between the instrument and the measured points is essential A well defined measurement point or target/prism is required to obtain the maximum accuracy 9

TOTAL STATION 10

TOTAL STATION INSTRUMENT An electronic digital theodolite and an electronic distance measurement in one integral unit They can automatically record horizontal and vertical angles and slope distances from a single setup Slope distance can be reduced to horizontal and vertical components instantaneously Given initial data they will display positions and elevations of sighted points 11

THREE BASIC COMPONENTS Total station instruments combine three basic components into one integral unit An electronic distance measurement (EDM) instrument An electronic angle measurement component A computer or microprocessor 12

Vertical axis Handle Collimator Objective lens Vertical circle lock Vertical tangent screw Circular level vial Horizontal circle lock Horizontal circle tangent screw Base Vertical circle Horizontal axis Optical plummet lens focus Optical plummet eyepiece Eyepiece focus Display & Keyboard Tribrach lock Tribrach Tribrach levelling screws 13

FEATURES Automatically observe Horizontal and vertical angles Slope distances from a single set up Instantaneously compute Horizontal and vertical distance components Elevations Coordinates of the point sighted Display the result on liquid crystal display (LCD) Store the data, either on board or in external data collectors connected to their communication ports 14

FEATURES The EDM instruments that are integrated into the total station instruments, lengths up to about 4km which is adequate for most job Total station instruments are manufactured with two graduated circles, mounted in mutually perpendicular planes Its horizontal circle is oriented in a horizontal plane, which automatically puts the vertical circle in a vertical plane Horizontal and vertical angles can then be measured directly in their respective planes Averaging of multiple angles and distance measurements Correcting electronically measured distances for prism constants, atmospheric pressure and temperature 15

TURNING ANGLES WITH TOTAL STATION Sight on the backsight utilizing the horizontal adjustment screw Zero set the instrument (this provides an initial reading of 0 seconds) Loosen tangent screw and rotate instrument to foresight Tighten tangent screw and bring cross hair exact on target with adjustment screw Read and record angle as displayed To close the horizon: Sight on foresight point from above and zero set instrument Rotate to former backsight and adjust instrument to exact Read and record angle as displayed Angle from direct and indirect should equal 360 degrees 16

TOTAL STATION DISTANCE MEASUREMENT Point the instrument at a prism (which is vertical over the point) Push the measure button and record the distance You can measure the horizontal distance or the slope distance, it is important that you note which is being collected If you are measuring the slope distance, the zenith angle must be recorded to allow the horizontal distance to be computed If you are collecting topographic data with elevations, it is important that the height of the instrument and the height of the prism be collected and recorded This can also be solved by setting the prism height the same as the instrument height 17

TOTAL STATION RULES When moving between setups in the field, proper care should be taken Before the total station is removed from the tripod, the food screw should be returned to the midpoints of the posts The instrument should never be transported on the tripod With adjustable leg tripods, stress on the legs can be avoided by retracting them to their shortest positions and lightly clamping them in position When returning the total station to its case, all locking mechanisms should be released If the instrument is wet, it should be wiped down and left in an open case it is dry 18

TOTAL STATION RULES Never point the instrument at the sun, this can damage the components of the instrument as well as cause immediate blindness Never move or transport the total station unless it is in the case provided Do not attempt to rotate the instrument unless the tangent screw is loose Avoid getting the instrument wet, if it does get wet, wipe it down and allow to dry in a safe area before storage Batteries of the total station must be charged regularly. At least once per month, the battery should be cycled Care should be taken at all times, these units are expensive ($8,000 - $45,000) 19

TOTAL STATION SIGHTING

TOTAL STATION SIGHTING

PRISM A corner-cube or reflective prism is essential for most Total Stations and EDM. The prism is used to return the transmitted beam to the instrument to allow a distance to be determined by time of flight or phase comparison Total stations allow for the direct input of temperature and pressure and automatic application of meteorological corrections. Most of the current EDM instruments use LASER beams and reflectors The latest models provide for reflector-less measurements, thus improving efficiency for certain applications drastically 22

ROUTINE CARE OF TOTAL STATION 23

ROUTINE CARE OF TOTAL STATION Before making the first set up of the day, visually inspect the instrument for damage. Check the machined surfaces and the polished faces of the lenses and mirrors. Try the clamps and motions for smooth operation Clean the exterior of the instrument frequently. Any accumulation of dirt and dust can scratch the machined or polished surfaces and cause friction or sticking in the motions. Remove dirt and dust with a clean, soft cloth or with a brush. Clean non-optical parts with a soft cloth or clean chamois Clean the external surfaces of lenses with a fine lens brush and, if necessary, use a dry lens tissue. Do not use silicone-treated tissues because they can damage coated optics. The lens may be moistened before wiping it, but do not use liquids for cleaning. Do not loosen or attempt to clean the internal surfaces of any lens After an instrument has been used in damp or cold situation, use special precautions to prevent condensation of moisture inside the instrument. If the instrument is used in cold weather, leave it in the carrying case in the vehicle during non-working periods rather take it into a heated room. If you store the instrument in a heated room overnight, remove it from the carrying case. If the instrument is wet, bring it into a warm, dry room, remove it from its case and leave it at room temperature to dry it 24

VEHICULAR TRANSPORT Transport and store instrument in positions that are consistent with the carrying case design. For example, total station should be carried and stored in their correct position. Many instrument cases indicate the position in which they should be transported Treat tribrachs, prism and tripods with care. Carry them in their shipping cases or cushion them with firm polyfoam or excelsior-filled cases to protect the from jolting or vibrating excessively 25

CASING AND UNCASING Before removing an instrument, study the way it is placed and secured in the case. Place it in the same position when you return it to the case. In removing the instrument from the case, carefully grip it with both hands, but do not grip the vertical circle standard or where pressure will be exerted or tubular or circular level vials 26

SOURCES OF ERROR IN TOTAL Instrument Errors STATION WORK Plate bubble out of adjustment Horizontal axis not perpendicular to vertical axis Axis of sight not perpendicular to horizontal axis Vertical circular index error Eccentricity of centres Circle graduation errors Errors caused by peripheral equipment 27

SOURCES OF ERROR IN TOTAL Natural Errors STATION WORK Wind Temperature effects Refraction Tripod settlement 28

SOURCES OF ERROR IN TOTAL Personal Errors STATION WORK Instrument not set up exactly over point Bubbles not centred perfectly Improper use of clamps and tangent screws Poor focusing Overly careful sights Careless plumbing and placement of rod 29

MISTAKES Some common mistakes in angle measurement work are: Sighting on, or setting up over the wrong point Calling out or recording an incorrect value Improper focusing of the eyepiece and objective lenses of the instrument Partiality on the tripod, or placing a hand on the instrument when pointing or taking readings 30

Thank You & Question and Answer 31