ept.i.p.s. Instructions for use Version B

Similar documents
ept.i.p.s. Version A

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

Eppendorf Xplorer Eppendorf Xplorer plus. Ordering information. Register your instrument!

NEW! ep Dualfilter T.I.P.S. Peak of perfection

N) manual. Biomaster Operating manual

Eppendorf ept.i.p.s. LoRetention Comparison of low retention pipette tips via simple and fast absorbance measurements in the BioPhotometer plus

N) justment. Register your instrument! Eppendorf Research plus. Factory Adjustment

No 022 December Application-Specific Requirements for Consumables in the Laboratory

Eppendorf UVette. Instructions for use

Raise the limits. Eppendorf Research plus

December 2010 No 036. The electronic Eppendorf Xplorer pipette Versatile adjustment

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 0

Simply Better Pipetting

PhysioCare Concept improved. The feeling of a new philosophy

Peak of Perfection. Made for a faster and easier daily routine: Eppendorf Liquid Handling Consumables

Larger Display Easier to Use. Generation E. Repeater E3 and E3x: Dispense without compromising accuracy or precision

PhysioCare Concept improved. The feeling of a new philosophy

Peak of Perfection. Made for a faster and easier daily routine: Eppendorf Liquid Handling Consumables

The Pure Truth. Eppendorf Forensic DNA Grade according to ISO 18385

NEW: 5.0 ml screw cap tube. The Missing Link. Eppendorf Tubes 5.0 ml Discover a new sample handling system

Now also in Eppendorf LoBind. Conical Competence. Eppendorf Conical Tubes 15 ml and 50 ml

The New Legend. Eppendorf Reference 2 Pipette

Eppendorf SmartBlock. Instructions for use

Eppendorf Vis Cuvettes. Instructions for use

Technical Report Exact dispensing of whole blood using the Eppendorf positive displacement system Multipette Xstream /Repeater Xstream

Eppendorf Reference : The pipette.

stance et Helper Eppendorf Pipet Helper Chemical Resistance

The New Legend. Eppendorf Reference 2 Pipette

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

Eppendorf Consumables it s Your sample. Peak of Perfection. Eppendorf Liquid Handling Consumables

Precise and Accurate whole Blood Dispensing with Multipette E3x and Combitips advanced

Simply better pipetting!

Spa & Wellness for Pipettes

High-throughput Isolation of Genomic DNA From Buccal Swab on the Eppendorf epmotion 5075 VAC

Multipette / Repeater M4 allows for fast, precise and sterile liquid transfer in cell culture

Pipette Tips. Pipette Tips. 1. Pipette Tips from Greiner Bio-One

Technology that counts

Technology that counts

Spa & Wellness for Pipettes

Still Making History. Over 50 years of pipetting

Devyser Index Plate A. Instructions for Use

Applications Note 228 September 2010

Automated purification of high quality genomic DNA

Technology that counts

New Promotion January 1 June 30, Take Good Care of Your Cells. Smart solutions from Eppendorf for your cell biology processes

NGS Made Easy. Optimize your NGS library preparation with the epmotion Automated liquid handling system

Get More! Quality Stability Purity: Eppendorf Plates

stance 4 Repeater M4 Register your instrument! Multipette M4 Repeater M4 Chemical Resistance

Automated Illumina TruSeq Stranded Total RNA library construction with the epmotion 5075t/TMX

Well within Reach. The Eppendorf Pipette Holder System

mag nanogram kit Description Kit uses

Applications Note 164 October 2007

Natural Winners. Eppendorf Liquid Handling Instruments: Unrivaled in technology, efficiency and handling for over 50 years

Automated Illumina TruSeq Stranded mrna library construction with the epmotion 5075t/TMX

New Promotions July 1 December 31, Take Good Care of Your Cells. More great offers for your cell biology processes

NEW! Your bacteria s favorite! Eppendorf Eporator

Natural Winners. Eppendorf Liquid Handling Instruments: Unrivaled in technology, efficiency and handling for over 50 years

symphony Reference Electrodes

Electrical safety testing Checklist

PhysioCare Concept. Make your Lab a better place

Cell Biology (Eukaryotic Cells)

Eppendorf BioSpectrometer 6135/6136/6137

NukEx Nucleic Acid Release Reagent

1. Intended use. 2. Introduction. 3. Assay description. 4. Limitations. Instruction For Use Gyrolab Generic PK Kit

Automated Illumina TruSeq DNA PCR-Free library construction with the epmotion 5075t/TMX

Please use only the valid version of the package insert provided with the kit. This kit is intended for Research Use Only.

Promotion period: September 15 - December 31, Super Sale. Quality at unbeatable prices

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

Catalog Liquid Handling, Sample Handling, Cell Handling

E.Z.N.A. MicroElute Clean-up Kits Table of Contents

cfkapture 21 Kit (3-5 ml) Isolation kit for circulating cell-free DNA from stabilized plasma PROTOCOL

Microcystin-LR ELISA Kit

First-Class Filter Tips

PIPETTORS (TIPS) Plastibrand Universal Pipet Tips. BrandTech

MAGBIO MAGBIO. cfkapture 21 Kit (3-5 ml) PROTOCOL Contents. Isolation kit for circulating cell-free DNA from stabilized plasma.

Cleaning and Decontamination of the ept.i.p.s. Box

Automated pipetting made easy new ep Motion 5073 family members for perfect PCR set-up and nucleic acids purifi cation or general liquid handling

Inserting grids into capsule Removing capsules from grid box Immunolabeling using template guide Preparing for TEM insertion

Microcystin-LR ELISA Kit

MAGBIO MAGBIO. cfkapture 21 Kit (1-2ml) PROTOCOL Contents. Isolation kit for circulating cell-free DNA from stabilized plasma.

Get the Eppendorf Advantage!

Routine Challenges in Molecular Biology

The Plus for your lab!

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 1

symphony Multisensor Probes

Technical Report Eppendorf Deepwell Plates and Microplates Investigations of sealing methods

Micropipetting Basics

Eppendorf Plate Deepwell 96 and 384: RecoverMax

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Micro Volume QuEChERS kit

Processing TEM Grids with mprep/g Capsules

Automated Illumina TruSight HLA v2 Sequencing Panel Library Preparation with the epmotion 5075t

Gyrolab Protein A Kit Quantification of residual Protein A ligands in the presence of excess amounts of IgG

Determination of Chloride using Potentiometry

Human IL-1 beta ELISA Kit

New Promotions July 1 December 31, Like It, Order It, Love It! New special offers for all of your laboratory needs

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

Color Compensation Set 1

Transcription:

r N) s use for use Instructions for use Version B

Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the copyright owner. Eppendorf and the Eppendorf logo are registered trademarks of Eppendorf AG, Hamburg, Germany. Biopur, Eppendorf Research, Eppendorf Reference, Eppendorf Xplorer, and ep Dualfilter T.I.P.S. are registered trademarks of Eppendorf AG, Hamburg, Germany. Registered trademarks are not marked in all cases with or in this manual. 0012 580.479-02/032013

Table of contents 3 Table of contents 1 Introduction.................................................4 2 Instructions for use...........................................4 3 Intended use.................................................4 4 Operation...................................................5 5 ep Dualfilter T.I.P.S............................................5 6 ep Dualfilter T.I.P.S. SealMax....................................6 7 ept.i.p.s. LoRetention.........................................6 8 Autoclave pipet tips...........................................7 1. Remove the packaging foil..................................7 9 Transport, storage and disposal.................................7 9.1 Storage................................................7 10 Technical data................................................7 10.1 Ambient conditions.......................................7 11 Purity grades and certificates...................................8 11.1 Eppendorf purity grades...................................8 11.2 Certificates - verifiable safety for you.........................9 12 Troubleshooting.............................................10 12.1 General errors..........................................10 13 Handling reloads............................................11 14 ept.i.p.s. combinations.......................................12

4 Introduction 1 Introduction ept.i.p.s. pipette tips are disposable plastic tips made of polypropylene (PP). ept.i.p.s. stands for Eppendorf Totally Integrated Pipetting System which means that form, material properties and fit are optimized for Eppendorf s manual and electronic piston-stroke pipettes. The pipette tips are available in different finishes and with different properties (filters, surfaces and purity grades). Pipette tips in the purity grade Sterile, Sterile + PCR clean, and Biopur are sterilized by electron beam. Every tray is color-coded and corresponds to the color of the control buttons of Eppendorf pipettes. 2 Instructions for use All tips and relevant pipettes must be used by trained laboratory workers. Before using tips familiarize yourself with the operating manual of the relevant instrument. Before using the tips, check pack and contents carefully for any damage. For filter tips, check whether there is a dualfilter in every tip and whether it is correctly positioned, undamaged and not twisted. If you detect any fault, do not use the tip. The tips should always be emptied into a container so that no fluid sprays into the environment. Dispose of tips in accordance with the relevant legal regulations. Tips should not be filled with fluids which attack PP, or in the case of filter tips also PE. 3 Intended use ept.i.p.s., in combination with adequate pipettes, are intended for dispensing liquids in the volume range of 0.1 μl 10 ml. In vivo applications (applications in or on the human body) are not allowed. ept.i.p.s. and the appropriate pipettes only must be used by correspondingly trained specialists. The user must have read thoroughly the operating instructions of the pipette and the instructions for use of the ept.i.p.s. and must have made himself familiar with the functioning of the pipette with the pipette tips.

Operation 5 4 Operation You will find recommendations for handling in the operating manual for the instrument you are using. The dispensing techniques used most frequently are forward pipetting, reverse pipetting, dispensing, sequential dispensing and diluting. Mechanical pipettes are only suitable for forward and reverse pipetting. Irrespective of the dispensing technique used, the following items should be taken into consideration during pipetting: When aspirating the liquid, the tip should only be immersed a few millimeters into the medium. The filled tip should be moved up against the wall of the vessel to avoid residues of liquid on the outside of the tip. Pre-wetting the tip up to three times will improve the accuracy and precision of the results. Liquid should be aspirated slowly and evenly. A waiting period of 3 seconds should be allowed for the liquid to rise in the tip. The pipette should be held vertically during aspiration. 5 ep Dualfilter T.I.P.S. During pipetting liquid flows through a small opening. A possible outcome of this are aerosols (dispersion of solid or liquid particles in gas). Aerosols, drops and splashes could contaminate the pipette and contaminations could be transferred to other samples. To avoid these unintended and unnoticed contaminations ep Dualfilter T.I.P.S. pipette tips should be used. The dualfilter is made up of hydrophobic polyethylene (PE). The first white layer defends from splashes and drops and the second blue layer builds an aerosol barrier.

6 ep Dualfilter T.I.P.S. SealMax 6 ep Dualfilter T.I.P.S. SealMax In addition to providing dual protection against aerosols and biomolecules, the ep Dualfilter T.I.P.S. SealMax builds a barrier against liquid in case of accidental over-pipetting. The violet layer blocks the liquid, preventing it from passing through the filter. The self-sealing filter release mechanism enables immediate recovery of nearly all pipetted sample by simple dispensing. When pipetting liquids with low surface tension (lower than water), the blocking effect might be reduced. 7 ept.i.p.s. LoRetention ept.i.p.s. LoRetention pipette tips are particularly suited to the dispensing of liquids containing detergents. The optimized surface of the ept.i.p.s. LoRetention pipette tips counteracts the reduced surface tension caused by detergents and also with corresponding solvents, so that the liquid runs off without forming a film. This increases sample recovery and pipetting accuracy. Please note: The filter in the pipette tip can clog if too much liquid is aspirated. The pipette tip may fall off during dispensing operations. Do not aspirate more than the nominal volume. The small amounts of residual moisture that may occur with ept.i.p.s. LoRetention pipette tips can appear to be higher than with standard ept.i.p.s. pipette tips as the residual moisture does not remain in the tip as a film, but collects as droplets due to the physical properties. Due to the physical properties of the surface of ep T.I.P.S. LoRetention pipette tips 0.1 10 μl S and 0.5 20 μl L the dispensing volume is slightly lower than the nominal volume when dispensing purely aqueous solutions. Reproducibility still has the same high performance as standard ept.i.p.s. pipette tips

Autoclave pipet tips 7 8 Autoclave pipet tips Do not use any additional desinfectants during autoclaving for box and rack. Product Temperature Pressure Time Number of possible cycles ep T.I.P.S. and ep T.I.P.S. 121 C 1 bar 20 min 5 times LoRetention ep T.I.P.S. Rack 121 C 1 bar 20 min 10 times ep T.I.P.S. Box 121 C 1 bar 20 min 100 times ep Dualfilter T.I.P.S. Can not be autoclaved. ep Dualfilter T.I.P.S. SealMax ep Dualfilter T.I.P.S. LoRetention 1. Remove the packaging foil. 2. Autoclave the pipet tips. 9 Transport, storage and disposal 9.1 Storage Air temperature 10 Technical data 10.1 Ambient conditions Relative humidity Atmospheric pressure In transport packaging -25 C 55 C 10 % 95 % 70 kpa 106 kpa Without transport packaging -5 C 45 C 10 % 95 % 70 kpa 106 kpa Ambience Only for use indoors. Ambient temperature 5 C 40 C Relative humidity 10 % 95 %, non-condensing. Atmospheric pressure 79.5 kpa 106 kpa

8 Purity grades and certificates 11 Purity grades and certificates 11.1 Eppendorf purity grades Eppendorf Quality Sterile PCR clean Sterile + PCR clean Biopur Batch testing (certified) for the following purity criteria Human-DNA-free DNA-free (free of human + bacterial DNA) DNase-free RNase-free PCR inhibitor-free ATP-free Pyrogen-free (endotoxin-free) Sterile (European Pharmacopoeia/ USP) ept.i.p.s. ept.i.p.s. Standard + Box + Set ept.i.p.s. Reloads ept.i.p.s. Racks ept.i.p.s. Singles ep Dualfilter T.I.P.S. ept.i.p.s. LoRetention ep Dualfilter T.I.P.S. LoRetention ep Dualfilter T.I.P.S. SealMax

Purity grades and certificates 9 11.2 Certificates - verifiable safety for you The number of standards, guidelines and specifications that apply to biological, diagnostic and industrial laboratories is constantly on the rise. As a result, the need to provide proof of observing these requirements has also increased. Three certificate categories are available for Eppendorf liquid handling consumables: 1. Batch-specific certificates are prepared by externally commissioned and recognized laboratories for the following purity grades: Biopur PCR clean PCR clean and Sterile You can access the batch-specific certificate at www.eppendorf.com/ consumables/certificates after entering the batch number of your product. 2. General certificates of conformity such as: Certificate of conformity for products in the PCR clean purity grade Certificate of conformity for verifying metal trace concentrations Certificate of conformity on the absence of surface active additives Certificate of conformity for HEPA classification of ep Dualfilter T.I.P.S. filter tips 3. Quality management and ISO certificates which verify conformity to ISO All certificates can be downloaded from our homepage www.eppendorf.com/ certificates.

10 Troubleshooting 12 Troubleshooting 12.1 General errors Symptom/ message Liquid is dripping from the tip and/or the dispensed volume is incorrect. Cause The tip is loose or the pipette tip is poorly fitted. Pipetting was too quick. The tip is withdrawn from the liquid too quickly. Remedy Firmly attach the pipette tips. Use ept.i.p.s. pipette tips. Withdraw the tip slowly from the liquid with a time delay (approx. 3 seconds).

Handling reloads ept.i.p.s. 11 13 Handling reloads "c lic k"

12 ept.i.p.s. combinations 14 ept.i.p.s. combinations Eppendorf Reference Reference 0.1 μl 10 μl S 0.1 μl 10 μl M 0.1 μl 20 μl M 0.5 μl 20 μl L 2 μl 20 μl 2 μl 100 μl 2 μl 200 μl 20 μl 300 μl 50 μl 1 000 μl 50 μl 1 250 μl 50 μl 1 250 μl L 500 μl 2 500 μl GELoader Microloader Color dark gray medium gray medium gray light gray orange blue green dark green red light gray ept.i.p.s. ept.i.p.s. LoRetention ep Dualfi lter T.I.P.S. ep Dualfi lter T.I.P.S. LoRetention ep Dualfi lter T.I.P.S. Sealmax Fixed volume 1 μl, 2 μl, 5 μl, 10 μl medium gray 10 μl 20 μl 25 μl, 50 μl, 100 μl 200 μl, 250 μl, blue 500 μl, 1 000 μl blue 1 500 μl, 2 000 μl, 2 500 μl red Variable volume 0.1 μl 2.5 μl dark gray 0.5 μl 10 μl medium gray 2 μl 20 μl light gray 2 μl 20 μl 10 μl 100 μl 50 μl 200 μl 50 μl 250 μl blue 100 μl 1 000 μl blue 500 μl 2 500 μl red compatible limited volume

ept.i.p.s. combinations 13 Eppendorf Research / Eppendorf Research plus 0.1 μl 10 μl S 0.1 μl 10 μl M 0.1 μl 20 μl M 0.5 μl 20 μl L 2 μl 20 μl 2 μl 100 μl 2 μl 200 μl 20 μl 300 μl 50 μl 1 000 μl 50 μl 1 250 μl 50 μl 1 250 μl L 500 μl 2 500 μl 100 μl 5 000 μl 1 ml 10 ml GELoader Research plus 1 ml 10 ml L Microloader Color dark gray medium gray medium gray light gray orange blue green dark green red violet turquoise light gray ept.i.p.s. ept.i.p.s. LoRetention ep Dualfi lter T.I.P.S. ep Dualfi lter T.I.P.S. LoRetention ep Dualfi lter T.I.P.S. SealMax Fixed volume 10 μl medium gray * 20 μl light gray * 10 μl 20 μl 25 μl, 50 μl, 100 μl 200 μl * 200 μl, 250 μl, 500 μl, 1 000 μl blue Variable volume 0.1 μl 2.5 μl dark gray 0.5 μl 10 μl medium gray 2 μl 20 μl light gray * 2 μl 20 μl 10 μl 100 μl 20 μl 200 μl 30 μl 300 μl orange 100 μl 1 000 μl blue 500 μl 5 000 μl violet 1 ml 10 ml turquoise compatible * Research plus limited volume

14 ept.i.p.s. combinations Eppendorf Research pro 0.1 μl 10 μl S 0.1 μl 10 μl M 0.1 μl 20 μl M 0.5 μl 20 μl L 2 μl 20 μl 2 μl 100 μl 2 μl 200 μl 20 μl 300 μl 50 μl 1 000 μl 50 μl 1 250 μl 50 μl 1 250 μl L 500 μl 2 500 μl 100 μl 5 000 μl 1 ml 10 ml GELoader Research pro 1 ml 10 ml L Microloader Color dark gray medium gray medium gray light gray orange blue green dark green red violet turquoise light gray ept.i.p.s. ept.i.p.s. LoRetention ep Dualfi lter T.I.P.S. ep Dualfi lter T.I.P.S. LoRetention ep Dualfi lter T.I.P.S. SealMax 0.5 μl 10 μl medium gray 5 μl 100 μl 15/20 μl 300 μl orange 50 μl 1 000 μl blue 50 μl 1 200 μl green 0.1/0.25 μl 5 ml violet compatible limited volume Eppendorf Xplorer/Xplorer plus 0.1 μl 10 μl S 0.1 μl 10 μl M 0.1 μl 20 μl M 0.5 μl 20 μl L 2 μl 20 μl 2 μl 100 μl 2 μl 200 μl 20 μl 300 μl 50 μl 1 000 μl 50 μl 1 250 μl 50 μl 1 250 μl L 500 μl 2 500 μl 100 μl 5 000 μl 1 ml 10 ml GELoader Xplorer 1 ml 10 ml L Microloader Color dark gray medium gray medium gray light gray orange blue green dark green red violet turquoise light gray ept.i.p.s. ept.i.p.s. LoRetention ep Dualfi lter T.I.P.S. ep Dualfi lter T.I.P.S. LoRetention ep Dualfi lter T.I.P.S. SealMax 0.5 μl 10 μl medium gray 5 μl 100 μl 15/20 μl 300 μl orange 50 μl 1 000 μl blue 50 μl 1 200 μl green 0.1/0.25 μl 5 ml violet 0.5 ml 10 ml turquoise compatible limited volume

Evaluate your manual Give us your feedback. www.eppendorf.com/manualfeedback Your local distributor: www.eppendorf.com/worldwide Eppendorf AG Hamburg Germany Phone: +49 40 538 01-0 www.eppendorf.com