DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Similar documents
DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

PRODUCT CATALOGUE PREssURE switch

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

ED 701 General Industry Pressure Transmitter

Pressure Transmitter ED 701

Pressure transmitters for industrial applications MBS 32 and MBS 33

Field IT 50T Series Transmitters

Z7A. Load cells. Special features. Data sheet. Wiring code

Conductivity sensor for hygienic applications

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Industrial Pressure Transmitter

Industrial Pressure Transmitter

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Pressure Measurement Single-range transmitters for general applications

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Pressure. 1 Fitting PA R - N R2

ATEX/IECEx RTD temperature probe

Fitting PS P - B - R2

Direct-operated 2/2-way compact solenoid valves Type EV210A

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Solenoid valves 2/2-way direct-operated type EV210A

Operating Instructions for Digital Manometer. Model: MAN-SD


Relative pressure transmitter type 520

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Installation guide 862 MIT / MIR

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Single point load cells

Absolute encoders multiturn

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

Direct-operated 2/2-way solenoid valves Type EV210B

Exchangeable measuring insets SensyTemp TSA101

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

RoHS. Versatile. X g. X 2 e

PHOENIX CONTACT - 04/2016. Features

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

E8EB-N0C2B E8EB-N0B2B

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Field mounted Temperature Transmitter TF212/TF212-Ex

Linear measuring technology

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

all stainless steel transducer multimedia compatibility

TABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic

Ring-Torsion Load Cells RTB

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Reflex-Radar BM 100 A

CS Series. Capacitance Type. Type. Proximity Sensor. Features

BTEL5000 / PTUL5000 Series Precision very low differential pressure transmitters

Solenoid valves Type EVUL

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Capacitive Sensors. Contents

TABLE OF CONTENT. Designation code. Circuit diagrams. Sensors. How to read sensor designations. Connection according to EN

HMA Series Amplified pressure sensors

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

TABLE OF CONTENT Designation code

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Electromagnetic Flowmeter

Cooling Water Flow Regulator

Type UB1 Load Cell. Option Stainless steel cable gland

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

FLOW SENSOR FOR LIQUID MEDIA Serie 210

I Ex d/e Switch- and Control-Equipment I

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

ISEmax CAM40/CAS40. Technical Information

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

AT9000 Advanced Transmitter Differential Pressure Transmitters

ANNEX to IECEx Certificate

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

VD1 CLC. Small Valves DIN-range with a higher k v -value

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Surface-mounting thermostats Series ATH

Certificate No.: IECEx BVS issue No. 1 Annex Page 1 of 8 Subject and Type

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

Full Metal Variable Area Flow Meter and Counter

Temperature sensors SensyTemp TSP311, TSP321, TSP331

Tecnología en Electrónica y Control SRL Ficha Técnica

Transcription:

DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar Output signals -wire:... 0 ma / -wire: 0... 0 V others on request Special characteristics hygienic version diaphragm with low surface roughness CIP / SIP cleaning up to 50 C vacuum resistant Optional versions IS-version Ex ia = intrinsically safe for gases and dust SIL according to IEC 6508 / IEC 65 in Hastelloy or Tantalum The pressure transmitter DMP P was designed for use in the food / beverage and pharmaceutical industry. The compact design with hygienic versions makes it possible to achieve an outstanding performance in terms of accuracy, temperature behavior and long term stability. The modular construction concept allows a combination of various process connections with different filling fluids and a cooling element. Several electrical connections complete the profile of DMP P. Preferred areas of use are Food and Beverage Pharmaceutical Industry Material and test certificates inspection certificate. according to EN 00 test report. according to EN 00 cooling element for media temperatures up to 00 C 7-06 BD SENSORS GmbH BD-Sensors-Straße Tel +9 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax +9 (0) 9 5 / 98 - info@bdsensors.de

DMP P Input pressure range Nominal pressure gauge - 0 0.0 0.6 0.5 0.0 0.60.6 Nominal pressure abs. - - - - 0.0 0.60.6 Overpressure 5 0.5 5 5 0 Burst pressure 7.5.5.5.5 7.5 7.5 5 Nominal pressure gauge / abs..5 6 0 6 5 0 Overpressure 0 0 0 0 80 80 05 Burst pressure 5 5 50 50 0 0 0 Vacuum resistance P N > bar: unlimited vacuum resistance P N bar: on request consider the pressure resistance of fitting and clamps Output signal / Supply -wire:... 0 ma / V S = 8... V DC SIL-version: V S = 8 V DC Option IS-protection -wire:... 0 ma / V S = 0... 8 V DC SIL-version: V S = 8 V DC Options -wire -wire: 0... 0 ma / V S =... 0 V DC 0... 0 V / V S =... 0 V DC Performance Accuracy standard: nominal pressure < 0. bar: ± 0.5 % FSO nominal pressure 0. bar: ± 0.5 % FSO option: nominal pressure 0. bar: ± 0.5 % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0 A] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time -wire: < 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) / Permissible temperatures Nominal pressure P N - 0 < 0.0 0.0 Tolerance band [% FSO] ± 0.75 ±,5 ± 0.75 in compensated range [ C] -0... 85 0... 50-0... 85 Permissible temperatures medium: -0... 5 C for filling fluid silicone oil -0... 5 C for filling fluid food grade oil electronics / environment: -0... 85 C storage: -0... 00 C Permissible temperature medium filling fluid silicone oil overpressure: -0 00 C vacuum: -0... 50 C 5 for cooling element 00 C filling fluid food grade oil overpressure: -0... 50 C vacuum: -0... 50 C 5 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions. max. temperature of the medium for nominal pressure gauge > 0 bar: 50 C for 60 minutes with a max. environmental temperature of 50 C 5 also for P abs bar Electrical protection Short-circuit protection Reverse polarity protection Electromagnetic compatibility Mechanical stability Vibration according to DIN EN 60068--6 Shock according to DIN EN 60068--7 Filling fluids Options permanent no damage, but also no function emission and immunity according to EN 66 G /": 0 g RMS (5... 000 Hz) G /": 500 g / msec others: 0 g RMS (5 000 Hz) others: 00 g / msec silicone oil food grade oil, compliant with CFR78.570 (Mobil SHC Cibus ; Category Code: H; NSF Registration No.: 500) others on request Materials Pressure port stainless steel.5 (6 L) others on request Housing stainless steel.0 (6 L) Option compact field housing stainless steel.05 (0), cable gland brass, nickel plated others on request Seals (media wetted) Optional Optional Media wetted parts FKM (recommended for medium temperatures 00 C) FFKM (recommended for medium temperatures > 00 C) Clamp, dairy pipe, Varivent : without stainless steel.5 (6 L) Hastelloy C-76 (.89) pressure port, seal, diaphragm others on request Tantalum on request pressure and level

DMP P Explosion protection (only for 0 ma / -wire) Approvals IBExU 0 ATEX 068 X / IECEx IBE.007X DX 9-DMP P zone 0: II G Ex ia IIC T Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh, the supply connections have an inner capacity of max. 7 nf to the housing Ambient temperature range in zone 0: -0... 60 C with p atm 0.8 bar up to. bar in zone or higher: -0... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Option SIL 6 according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight min. 00 g (depending on process connection) Installation position any (standard calibration in a vertical position with the pressure port connection down; differing installation position for P N bar have to be specified in the order) Operational life CE-conformity ATEX Directive 6 only for 0 ma / -wire Wiring diagrams -wire-system (current) p supply + > 00 x 0 6 pressure cycles EMC Directive: 0/0/EU 0//EU -wire-system (current / voltage) supply + p V S V S supply I supply I/U signal + A/V Pin configuration Electrical connection ISO 00 Supply + Supply Signal (only -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) Mx / metal (-pin) Shield ground pin 5 field housing IN + IN - OUT+ cable colour (IEC 60757) wh (white) bn (brown) gn (green) gnye (green-yellow) standard option ISO 00 Binder Series 7 Mx -pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 7 compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 68) 8 universal field housing stainless steel.0 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 7 standard: m PVC cable without ventilation tube (permissible temperature: -5 70 C) 8 different cable types and lengths available, permissible temperature depends on kind of cable www.bdsensors.com

DMP P Mechanical connection (dimension in mm) Option Option G/" flush DIN 85 9 G /" flush DIN 85 G" flush DIN 85 with ISO 00 with ISO 00 G/" flush G" flush G" cone cooling element 00 C with radial o-ring 9 with radial o-ring (PN bar) with ISO 00 7-06 Varivent dairy pipe (DIN 85) Clamp (DIN 676) PN 5 bar with ISO 00 with ISO 00 dimension in mm size DN 5 DN 0 DN 50 A 5 B 56 68.5 P N 0,5 0 SIL- and SIL-Ex version: total length increases by 6.5 mm! metric threads and other versions on request 9 possible only for P N bar 0,5 0 0,5 5 dimension in mm size ¾ DN 5 DN DN 50 A 5 B 5 50.5 50.5 6 P N 8 7-06 0,5 6 * higher pressure ranges on request 6 6 06 BD SENSORS GmbH The specifications given in this document represent the state of engineeringat the time of publishing. We reserve the right to make modifications to the specifications and materials. DMPP_E_086 pressure Tel +9 and (0) level 9 5 / 98-0 www.bdsensors.com Fax +9 (0) 9 5 / 98 - info@bdsensors.de

DMP P - - - - - - - - - Pressure gauge absolute 5 0 0 5 0 Input 0.0 0 0 0 0.6 6 0 0 0.5 5 0 0 0.0 0 0 0 0.60 6 0 0 0.0 0 0.6 6 0.5 5 0.0 0 0 6.0 6 0 0 0 0 0 6 6 0 5 5 0 0 0 0-0 X 0 9 9 9 Output 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 0 ma / -wire SIL 0 ma / -wire SIL with Intrinsic safety 0 ma / -wire E S ES Accuracy standard for P N 0. bar 0.5 % standard for P N < 0. bar 0.5 % 5 option for P N 0. bar 0.5 % Electrical connection Male and female plug ISO 00 Male plug Binder series 7 (5-pin) Cable outlet with PVC-cable Cable outlet Male plug Mx (-pin) / meta Compact field housing stainless stee stainless steel.05 0 0 0 0 T A 0 T R 0 M 0 8 5 0 9 9 Mechanical connection G/" with flush 5 welded diaphragm (DIN 85) Z 0 0 G/" with flush welded diaphragm (DIN 85) Z 0 G" with flush welded diaphragm (DIN 85) Z G" DIN 85 with rad. o-ring 6 and flush diaphragm Z 5 7 G/" DIN 85 with rad. o-ring 5 and flush diaphragm Z 6 G " cone Clamp DN 5 / " (DIN 676) / A Clamp DN / /" (DIN 676) / A Clamp DN 50 / " (DIN 676) / A Clamp /" (DIN 676) / A Dairy pipe DN 5 (DIN 85) Dairy pipe DN 0 (DIN 85) Dairy pipe DN 50 (DIN 85) Varivent DN 0/50 / A K C 6 C 6 C 6 C 6 9 M 7 M 7 5 M 7 6 P 9 9 Stainless steel.5 (6L) Tantalum T consult Hastelloy C-76 (.89) H Seals for clamp, dairy pipe, Varivent : without 0 for inch thread - standard: FKM for inch thread - option: FFKM 7 Filling Fluids silicone oil food grade oil (FDA) / A Special version standard with cooling element up to 00 C / A 0 0 0 0 0 9 9 absolute pressure possible from 0. bar standard: m PVC cable without ventilation tube (permissible temperature: -5 70 C), others on request Ordering code DMP P cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable The cup nut has to be mounted by production of pressure transmitter with electrical connection field housing and mechanical connection dairy pipe. The cup nut has to be ordered as separate position. 5 possible only for P N bar 6 possible only for P N bar Varivent is a brand name of GEA Tuchenhagen GmbH, Hastelloy is a brand name of Haynes International Inc. 06.05.05 05 BD SENSORS GmbH - The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.