Infrared spectroscopy

Similar documents
Advanced Pharmaceutical Analysis

SPECTROSCOPY MEASURES THE INTERACTION BETWEEN LIGHT AND MATTER

Application of IR Raman Spectroscopy

Infrared Spectroscopy

Infra Red Spectroscopy

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

ORGANIC - BROWN 8E CH INFRARED SPECTROSCOPY.

Learning Guide for Chapter 3 - Infrared Spectroscopy

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 4: Basic principles and Instrumentation for IR spectroscopy

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Infrared Spectroscopy

Lecture 11. IR Theory. Next Class: Lecture Problem 4 due Thin-Layer Chromatography

Radiant energy is proportional to its frequency (cycles/s = Hz) as a wave (Amplitude is its height) Different types are classified by frequency or

Infrared spectroscopy. Siriphorn Laomanacharoen Bureau of Drug and Narcotic Department of Medical Sciences 2 March 2012

Fourier Transform IR Spectroscopy

Instrumental Chemical Analysis

Organic Spectra Infra Red Spectroscopy H. D. Roth. THEORY and INTERPRETATION of ORGANIC SPECTRA H. D. Roth. Infra Red Spectroscopy

Infrared Spectroscopy

Spectroscopy. Fourier Transform Infrared (FT-IR) Spectroscopy

ORGANIC - BRUICE 8E CH MASS SPECT AND INFRARED SPECTROSCOPY

Infrared Spectroscopy: Identification of Unknown Substances

1.1. IR is part of electromagnetic spectrum between visible and microwave

Learning Guide for Chapter 3 - Infrared Spectroscopy

Infrared spectroscopy Basic theory

EXPT. 7 CHARACTERISATION OF FUNCTIONAL GROUPS USING IR SPECTROSCOPY

Molecular Spectroscopy. H 2 O e -

Table 8.2 Detailed Table of Characteristic Infrared Absorption Frequencies

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

Infrared Spectroscopy

Introduction. The analysis of the outcome of a reaction requires that we know the full structure of the products as well as the reactants

Mid-IR Sampling Techniques for Biological Molecules

Structure Determination. How to determine what compound that you have? One way to determine compound is to get an elemental analysis

m m lighter 'atom' dominates 2 INFRARED SPECTROSCOPY All modes of vibrations are not IR active.

Infrared Spectroscopy An Instrumental Method for Detecting Functional Groups

12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy

1. Which compound would you expect to have the lowest boiling point? A) NH 2 B) NH 2

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

6. CHARACTERIZATION OF AS (III) IONS BIOSORPTION BY THE LIVE, HEAT AND ALKALINE- TREATED FUNGAL BIOMASS ON THE BASICS OF SURFACE STUDIES

General Infrared Absorption Ranges of Various Functional Groups

More information can be found in Chapter 12 in your textbook for CHEM 3750/ 3770 and on pages in your laboratory manual.

Educational experiment package Volume 1. Molecular spectroscopy

Symmetric Stretch: allows molecule to move through space

Welcome to Organic Chemistry II

Infra-red Spectroscopy

Fourier Transform Infrared Spectroscopy (Perkin Elmer - Spectrum One)

Infrared Spectroscopy. Provides information about the vibraions of functional groups in a molecule

Química Orgânica I. Ciências Farmacêuticas Bioquímica Química. IR spectroscopy AFB QO I 2007/08 1 AFB QO I 2007/08 2

Chapter 5. Infrared Spectrophotometry

Spectroscopy. Page 1 of 8 L.Pillay (2012)

1901 Application of Spectrophotometry

CHEM 51LB: EXPERIMENT 7 SPECTROSCOPIC METHODS: INFRARED SPECTROSCOPY (IDENTIFICATION OF FUNCTIONAL GROUPS)

Spectroscopic techniques: why, when, where,and how Dr. Roberto GIANGIACOMO

Chem HH W11 Notes - Dr. Masato Koreeda Date: January 5, 2011 Topic: _IR Spectroscopy_ page 1 of 3. fingerprint region

Fourier Transform Infrared Spectroscopy of Metal Ligand Complexes *

MOLECULAR REPRESENTATIONS AND INFRARED SPECTROSCOPY

Determination of Chemical Composition and Molecular Microstructures: Infrared Spectroscopy

Chemistry 343- Spring 2008

Glossary. Analyte - the molecule of interest when performing a quantitative analysis.

Infrared Spectroscopy: How to use the 5 zone approach to identify functional groups

Chapter 25: The Chemistry of Life: Organic and Biological Chemistry

Reference Standards Page 156 For calibrating your spectrometer. PIKECalc Page 159 For FTIR sampling computations

How to Interpret an Infrared (IR) Spectrum

IR absorption spectroscopy

CHEM 3760 Orgo I, F14 (Lab #11) (TECH 710)

(2) Read each statement carefully and pick the one that is incorrect in its information.

Vibrations. Matti Hotokka

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

Infrared Spectroscopy

PSI Chemistry. 3) How many electron pairs does carbon share in order to complete its valence shell? A) 1 B) 2 C) 3 D) 4 E) 8

CHEM 3.2 (AS91388) 3 credits. Demonstrate understanding of spectroscopic data in chemistry

E35 SPECTROSCOPIC TECHNIQUES IN ORGANIC CHEMISTRY

Organic Compound Identification Using Infrared Spectroscopy. Description

Mid-IR Methods. Matti Hotokka

7a. Structure Elucidation: IR and 13 C-NMR Spectroscopies (text , , 12.10)

Learning Organic Chemistry

ORGANIC - CLUTCH CH ANALYTICAL TECHNIQUES: IR, NMR, MASS SPECT

Characterisation of vibrational modes of adsorbed species

Vibrational Spectroscopies. C-874 University of Delaware

CHEM 3760 Orgo I, S12, Exp 5 (Lab #6) (TECH 710: IR Unknown)

ORGANIC - CLUTCH CH ANALYTICAL TECHNIQUES: IR, NMR, MASS SPECT

Chem 1075 Chapter 19 Organic Chemistry Lecture Outline

video 14.4 isomers isomers Isomers have the molecular formula but are rearranged in a structure with different properties. Example: Both C 4 H 10

ORGANIC - EGE 5E CH UV AND INFRARED MASS SPECTROMETRY

QuickTime and a TIFF (Uncompressed) decompressor are needed to see this picture. Organic Chemistry. QuickTime and a are needed to see this picture.

Molecular Geometry: VSEPR model stand for valence-shell electron-pair repulsion and predicts the 3D shape of molecules that are formed in bonding.

Infrared Spectroscopy used to analyze the presence of functional groups (bond types) in organic molecules How IR spectroscopy works:

C h a p t e r F o u r t e e n: Structure Determination: Mass Spectrometry and Infrared Spectroscopy

Vibrational Spectroscopy

9/28/10. Visible and Ultraviolet Molecular Spectroscopy - (S-H-C Chapters 13-14) Valence Electronic Structure. n σ* transitions

Spectroscopy in Inorganic Chemistry. Vibration and Rotation Spectroscopy

6.2 Polyatomic Molecules

Spectroscopy in Inorganic Chemistry. Vibration and Rotation Spectroscopy

Chap 4 Optical Measurement

Infrared Spectroscopy (IR)

CHAPTER 2: Structure and Properties of Organic Molecules

All the manufacturers use a heated ceramic source.

8. Spectrum continued

Lecture 13 Organic Chemistry 1

Chemistry 2 Summer 2008 Exam 3 KEY Chapters 11, 13, & 15

Transcription:

Infrared spectroscopy Chapter content Theory Instrumentation Measurement techniques Midinfrared (MIR) Identification of organic compounds Quantitative analysis Applications in food analysis Nearinfrared (NIR) Properties of the technique Applications in food analysis Infrared spectroscopy measurement of IR radiation absorbed by or reflected from a sample absorption of IR radiation is related to the changes of vibrational or rotational energy states of molecules applications: analysis of gaseous, liquid or solid samples identification of compounds quantitative analysis information deduced from IR spectrum: functional groups of molecules, constitution of molecules interaction among molecules 1

Vibrational transitions fundamental (normal): change of vibrational quantum number v =1 high probability high values of ε overtones: the difference of vibrational quantum number v =2; 3 lower probability low values of ε combination: simultaneous change of two or more vibrational numbers for a polyatomic molecule Types of vibrations stretching: the length of chemical bond (the internuclear distance) is changed symmetric antisymmetric bending: the valence angle is changed symmetric and antisymmetric vibrations vibrations in plane and vibrations out of plane 2

Example: vibrations of a threeatomic nonlinear molecule and a group of three atoms in a multiatom molecule H 2 O symmetric stretch antisymmetric stretch scissoring bend + + + CH 2 rocking bend wagging bend twisting bend Which substances give a signal in IR spectrum? molecules that contain polar bonds i.e. molecules composed of atoms of different elements = organic compounds and inorganic compounds (H 2 O, CO 2, NO 2, HCl, salts...) NO pure chemical elements in molecular or crystal state = e.g. Ar, O 2, O 3, N 2, Cl 2, S 8, silicon, graphite, diamond IR signal of a molecule is proportional to square of the change of dipole moment that occurs during vibrational motion of the molecule. 3

Spectral regions and corresponding analytical techniques Near infrared region (near infrared spectroscopy, NIR) Mid infrared region (mid infrared spectroscopy, Mid IR, MIR) Far infrared region (far infrared spectroscopy, FIR) λ (µm) 0.8 2.5 2.5 25 25 1 000 ~ ν (cm 1 ) 12 500 4 000 4 000 400 400 10 MIR normal vibrational transitions NIR overtones FIR normal vibrations of weak bonds and bonds of heavy atoms Instrumentation for IR spectroscopy Main components of an instrument radiation source measuring (and reference) cell wavelength selector detector (transducer) Types of instruments simple instruments with a filter classical instruments with a monochromator instruments based on an interferometer (FTIR) 4

Double beam vs. single beam spectrometers Sources of IR radiation for NIR: tungsten lamp for MIR: Globar = electrically heated (1100 C) silicon carbide rod it gives maximum intensity at λ = 2 µm; at lower temp. shift of maximum to a longer wavelength (600 C λ max = 3,5 µm) lasers CO 2, PbS λ max = 9 11 µm 5

Transducers of IR radiation pyroelectric triglycine sulphate detectors work at the normal temperature photoconductive detectors MCT (HgTe/CdTe) work at the temp. of liquid nitrogen (196 C) high sensitivity fast response are used for MIR and FIR germanium bolometers are used for FIR work at the temp. of liquid helium (271,7 C) Fourier transform IR spectrometers (FTIR) based on Michelson interferometer The beam from source is divided on splitter into two halves; the first is reflected to the fixed mirror, while the second is transmitted to the movable one; the reflected beams are recombined in the splitter again and an interference of waves occurs. For monochromatic radiation, a destructive interference of beams occurs, when δ = (n+0,5) λ δ is optical retardation (= twotimes the difference between the distance of the fixed mirror to the splitter and the distance of the movable one to the splitter). The constructive interference occurs, when δ = λ; 2 λ;3 λ; n λ When polychromatic radiation passes through the interferometer and the sample, the obtained record is an interferogram, which is converted into IR spectrum by Fourier transformation. 6

Advantages of FTIR dispersion elements are not necessary more energy enters the sample fast spectrum recording (< 1s) high resolution (up to 0.01 cm 1 ) Measurement techniques of IR spectroscopy Sample types and sample preparation Cells for transmission measurements have windows made of NaCl, KBr, CaF 2, ZnSe, AgCl, TlBr/TlI pro MIR CsBr, polyethylene (for FIR) glass, quartz glass (for NIR) Gaseous samples Cells are firstly evacuated and then filled with a sample; cell path length ranges from 10 cm to 80 m (multiple reflection of the beam inside the cell, outer size of cell is up to 1 m) 7

Liquid samples Demountable cell for liquid samples For aqueous solution it is necessary to use windows made of CaF 2 or ZnSe (insoluble in water). The measurement is possible only within the interval of 1400 1000 cm 1, used e.g. for the analysis of sugars in fruit juices based on the measurement of thin films (10 50 µm). Liquid samples Solvents for samples applicable in MIR Solvent Measurement in wavenumber region 4000 1600 cm 1 and 1500 850 cm 1 CCl 4 CHCl 3 4000 1250 a cm 1 and 1150 850 cm 1 CS 2 4000 1650 b cm 1 and 1400 500 cm 1 a with exception of strong bands at 3050 and 940 cm 1 b with exception of strong bands at 2350 and 2200 cm 1 Pure liquid samples (e.g. oils) and gels can be measured in a very thin film (1 µm) by transmission technique of by ATR technique. 8

Solid samples preparation of KBr discs (pellets): 115 mg of sample + 200 mg KBr the well powdered mixture is pressed under vacuum to form a pellet which is inserted into a holder in the spectrometer (disadvantage: KBr absorbs some water, the bands of which may interfere with the sample spectrum) preparation of Nujol mull: powdered sample is dispersed in mineral (paraffin) oil to form a suspension (disadvantage: bands CH a CC bonds of the sample are overlapped with those of paraffin oil) Measurement techniques in IR spectroscopy Transmission technique the measurement of transmittance, absorbance T = I / I 0 = 10 εbc I 0 / I = 10 εbc A λ = log 10 (1/T) = log 10 T = log 10 (I 0 /I) = ε λ. b. c 9

Reflection techniques the measurement of the radiation reflected from sample reflectance R = I / I 0 optical density OD = log 10 (1/R) = log 10 R Specular Diffusion reflection: reflection: common technique in NIR for solid powdered samples Special arrangement: measurement of interactance the use of optical cables ATR technique (attenuated total reflectance, or internal reflectance) n 1 n 2 n 1 a sample (liquid, semisolid, solid) is placed in a layer on the surface of the crystal; pressure is applied for solid samples to achieve good contact between the sample and the crystal the crystal must have high refractive index n 2 (higher than that of sample n 1 ) the beam enters the crystal at the incidence angle θ higher than critical angle θ c = arcsin (n 1 /n 2 ); under this condition, the beam is totally caught by the crystal, i.e. a complete internal reflection occurs and the beam travels in the crystal; after one or multiple reflections, the beam leaves the crystal and reaches the detector at the crystalsample interface, the beam actually penetrates a very short distance (<2 µm) into the sample and the absorption of specific wavelengths occurs penetration depth depends on the wavelength: d p = λ/2π [sin 2 θ(n 1 /n 2 ) 2 ] 0,5 [µm] 10

Advantages of ATR simple preparation of sample before measurement nontransparent samples can be analysed Requirements for a sample and a crystal good adherence of the sample to the crystal mechanical strength of the crystal (when the sample is pressed against the crystal) inertness of the crystal against samples removal of sample residue from the crystal using various solvents Kind of crystal diamond sapphire NaCl ZnSe Ge Si TlBr/TlI Spectral range 30 000 200 cm 1 50 000 1 780 40 000 590 20 000 454 5 500 600 8 300 6 600 20 000 250 n at 1000 cm 1 2.4 1.74 1.49 2.4 4.0 3.4 2.37 Midinfrared spectroscopy (Mid IR) the mid IR spectra consist of the bands corresponding mainly to normal (fundamental) vibrations the number of vibrations of a molecule composed of N atoms is 3N6 (for nonlinear molecules) or 3N5 (for linear molecules) absorption bands are stronger, when two or more vibrations have the same frequency (wavenumber); such vibrations are called degenerated vibrations strong signals are caused by vibrations of polar bonds, especially multiple polar bonds, such as C=O single bonds of a low polarity (especially CC) give very weak signals (and totally non polar bonds give no signal) 11

Identification of organic compounds using Mid IR Mid IR region is divided into two subregions: region of characteristic vibrations of functional groups 2.5 8 µm (4000 1250 cm 1 ) contains the characteristic bands of individual bonds and functional groups that correspond mainly to stretching vibrations fingerprint region 8 25 µm (1250 400 cm 1 ) contains the bands corresponding mainly to bending vibrations the spectrum in this region characterises each molecule as an integral whole Example of spectra of isomeric monoterpenes the spectra are very similar in in the region of characteristic vibrations (even almost identical around 3000 cm 1 ) but very different in the fingerprint region 12

Steps of identification process 1. searching for functional groups on the basis of characteristic vibrations (using tables) 2. confrontation with the results of other tests elementary analysis of the compound stoichiometric formula of the compound determination of molecular mass (from mass spectrum) molecular formula of the compound calculation of unsaturation index U = 1 + 0.5 (2. number of C + number of N+P number of H number of halogen atoms) U=0 no multiple bond, no ring U=1 1 double bond or 1 ring U=2 2 double bonds or 1 triple bond or 1 double+1 ring U=3 3 double bonds or 3 rings or 1 double+1 triple bond or 2 double bonds+1 ring or 1 double bond+2 rings or 1 triple + 1 ring Steps of identification process 3. drawing of all possible structures that correspond to the presence of groups, molecular formula and unsaturation index 4. comparison of the measured IR spectrum with the spectra of the suggested compounds found in an atlas or a database of spectra identification 5. verification of identity using other spectral methods (MS, NMR) 13

Trends in wavenumbers of carbon chemical bonds effect of carbon hybridization: CC bond C H bond C C 1200 cm 1 sp 3 C H 2900 cm 1 C=C 1650 sp 2 C H 3100 C C 2150 sp C H 3300 effect of mass of X atom in C X bond: C H 2900 cm 1 C C 1200 C O 1100 C Cl 750 C Br 600 C I 500 Look on IR spectrum: identification of functional groups 1. carbonyl groups START strong band 18201660 cm1 (C=O group) NO 2 KETONE NO wide band 35503200 cm1 (sometimes overlaps with the band of CH groups) NO medium NO strong band NO two strong bands NO band 13001100 cm1 1810 and 1760 cm1 ca 3400 cm1 (CO bond) (C=O groups) (NH group) two weak bands 2850 and 2750 cm1 at the right side of CH band CARBOXYLIC ACID AMIDE ESTER or LACTONE ANHYDRIDE ALDEHYDE 2 14

O C=O O O CH C=O CO Look on IR spectrum: identification of functional groups 2. other functional groups 2 band 13001000 cm1 (CO bond) NO medium to strong band(s) at 3400 cm1 (NH bond) NO strong band bellow 800 cm1 (CX bond) NO 2 strong bands 16001530 cm1 and 13901300 cm1 NO wide band at 34003300 cm1 (OH bond) NO ALCOHOL or PHENOL ETHER AMINE HALIDE NITROCOMP. 3 15

CH 3 CH 3 C OH CH 3 pure tert. butanol diluted solution of tert. butanol in CHCl 3 OH OH CO OH OH OCH 3 C=C CO 16

Look on IR spectrum: identification of functional groups 3. double bond and aromatic ring 3 sharp band at ca 1650 cm1 (C=C bond)* * the peak can be overlapped with the signal of carbonyl group medium band(s) 16001450 cm1 ALKEN E or ARENE band(s) at ca 3030 cm1 890680 cm1 optionally also 17001500 cm1 ARENE NO NO 4 1ALKENE CH 3 CH 3 CH 3 CH 3 CH NH 2 NH CBr Br benzene ring 17

Look on IR spectrum: identification of functional groups 4. triple bond 4 medium sharp band 2250 cm1 (C N group) NITRILE NO weak sharp band 2150 cm1 (C C bond) ALKYNE 3300 cm1 ( CH bond) 1ALKYNE If the spectrum does not contain any of above mentioned bands, the compound is probably a saturated hydrocarbon. Spectra of these hydrocarbons are simple and contain : strong band at ca 2900 cm 1 (CH stretching), medium and sharp band at ca 1470 cm 1 (CH 2 bending), weak sharp band at ca 1400±50 cm 1 (CH 3 bending), optionally a band at 720 cm 1 (signal of longer hydrocarbon chains) Quantitative analysis using Mid IR Measured quantities: absorbance A or optical density OD (OD = log 1/R) integral intensity (area bellow the curve in appropriate wavenumber boundaries, the background spectrum is firstly subtracted) Applications in food analysis 1. Determination of transunsaturated fatty acids in fats wavenumber 960970 cm 1 (cis double bonds absorbs at 700±50 cm 1, terminal double bonds at ca 900 cm 1 ) TAG are converted to fatty acid methylesters, which are dissolved in CS 2 and the absorbance is measured; elaidic acid methylester is used as the calibration standard 18

Applications in food analysis 2. Determination of main food components using ATR technique water carbohydrates fat water A: spectrum of chocolate B: spectrum of bread Near infrared spectroscopy (NIR) NIR region: 800 to 2500 nm or 12 500 to 4 000 cm 1 NIR spectra contain less intensive signals combination bands overtone bands the change of vibration quantum number v is 2; 3; 4 ; if the fundamental vibration occurs at the wavelength of λ 0, the first overtone appears at λ 1 λ 0 /2, the second at λ 2 λ 0 /3, the third at λ 3 λ 0 /4, etc., the strength of signal gradually decreases NIR spectra are measured by transmission technique diffusionreflection technique or ATR technique 19

NIR spectra of some food samples NIR spectrum of wheat gluten signals of proteins: 1190, 1488, 1735, 1974, 2054, 2162 nm NIR spectrum of starch main signal 2100 nm NIR spectra of some food samples NIR spectrum of dried egg white signals of proteins 2054 and 2162 nm NIR spectrum of dried eggs peak of proteins 2162 nm is distorted peaks of lipids 1200, 1750 and 2350 nm 20

Reflection and transmission NIR spectra A: NIR reflection spectrum of wheat components: starch (1), protein (2), fat (3), water (4) B: NIR transmission spectrum of wheat and its components Note: some foods in a 12 cm layer are transparent for the radiation at 700 1100 nm Applications of NIR in food analysis Determination of water NIR spectra of whet flour (1) and dried wheat flour (2) absorption bands of water in NIR: 1940, 1450, 1190, 970 and 760 nm position of peaks is moderately affected by molecular interactions among water and other sample components 1450, 970, 760 nm are the first, the second and the third overtone of OH bond vibration, resp. 1940 and 1190 are combination bands 21

Modes of water determination measurement of A 1940 (linear range 0 2.5 % H 2 O) or A 1450 (0 4 % H 2 O) of the water extract obtained from solid samples using a polar solvent that does not contain an OH group (N,Ndimethylformamide) applied e.g. for analysis of dried vegetables and spices azeotropic distillation of water with 1,4dioxane and measurement of A 1910 of distillate applied for coffee bean analysis measurement of A 970 analysis of beer, meat, cereal grain preparation of a suspension of a powdered sample in CCl 4 and the measurement of OD 940 and OD 2080 ; water content is proportional to the difference of values; a calibration using an independent method is necessary measurement of reflectance of solid samples (flour, grain, malt, milk powder, various seeds, hop ) at 1940 nm and at another reference wavelength (2310, 1850, 2000 nm) a calibration using an independent method of water determination is necessary Plot of moisture content in flour and OD 1940 = log 1/R 1940 (data for 40 samples) Plot of moisture content in flour and the difference OD 1940 OD 2310 Example of regression equation Water content = 12.69 + 81.49. (log 1/R 1940 log 1/R 2310 ) [%] The equation is valid only for the specific kind of samples (e.g. wheat flour but not rye flour) and the type of instrument. 22

Determination of proteins is usually based on the measurement of reflectance at 2180 nm completed with several reference values Example of regression equation for whet flour: Protein content = 12.68 + 493.7. log 1/R 2180 323.1. log 1/R 2100 234.4. log 1/R 1680 [%] Accuracy of protein determination: plot of the results of NIR analysis (y) and those of Kjeldahl method (x) Determination of fat the main absorption bands of fats in NIR belong to vibrations of CH 2 groups of fatty acids chains; they include: first overtones 1734 and 1765 nm, the second overtone 1200 nm, combination bands 2310 a 2345 nm. NIR spectra of groundnut oil (1) and paraffin oil (2) 23

Modes of fat analysis via NIR reflectance measurement e.g. analysis of meat by the measurement at 1725 nm and the reference value at 1650 nm; similar procedures were described for cereals, cocoa, cheese, milk powder, oilseeds etc. transmission measurement in 8001100 nm range in the second derivative spectrum of absorbance the ratio of values at 931 and 946 nm or those at 931 and 1062 nm is proportional to the fat content applied for analysis of meat Fat unsaturation determination NIR spectra of fats contain bands at 1180, 2143 and 2190 nm that correspond to the presence of cis CH=CH bonds; the measurement of log 1/R 2143 can be an easy accessible indicator of unsaturation, equivalent to the iodine value Determination of carbohydrates NIR spectra of individual carbohydrates are very similar and contain a lot of peaks see the table glucose sucrose starch cellulose glucose sucrose starch cellulose 1198 nm 1196 nm 1202 nm 1207 nm 2008 nm 1269 1276 1274 1278 2073 2073 1371 1368 1360 1365 2103 2100 2088 1440 1493 1436 1489 1432 1492 1431 1487 2154 2200 2150 2191 2190 2200 1589 1586 1580 1584 2275 2255 2278 2273 1705 1688 1702 1707 2318 2318 1729 2330 2336 1750 1789 1762 1773 1772 2364 2368 2360 2347 1834 1823 1824 1824 24

Some applications of NIR for the analysis of sugars determination of Glc, Fru, Suc in powdered mixtures determination of sucrose in wine (0.8 9 %), determination of sugars in fruit juices transmission measurement in a 1 2mm layer determination of sucrose in chocolate and sweets NIR spectra of sucrose (1), fat (2) and chocolate (3) Determination of alcohols direct determination of ethanol in wine by the measurement of absorbance in a 1mm cell (range 11 17 % v/v EtOH) determination of glycerol NIR spectra of ethanol (1) and wine (2) NIR spectra of pure glycerol and ethanol 25