Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

Similar documents
An Introductions to Advanced GPC Solutions

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

GPC/SEC An essential tool for polymer analysis

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Differentiation of polymer branching and composition using the Mark Houwink plot

Practical Steps in GPC Method Development

Comprehensive Polymer Analysis Strategies

GPC/SEC standards. Product guide

Application compendium. Authors. Greg Saunders, Ben MacCreath Agilent Technologies, Inc. A guide to multi-detector gel permeation chromatography

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Maximizing Performance Through GPC Column Selection

GPC/SEC standards. Product guide

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Analysis of polyolefins by GPC/SEC

EcoSEC - semi-micro GPC/SEC system for high throughput polymer analysis

Optimizing GPC Separations

Latest Developments in GPC Analysis of Adhesive and Sealant Polymers Mark Pothecary PhD Americas Product Manager Malvern Instruments

Polymer analysis by GPC-SEC. Technical Note. Introduction

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Gel Permeation Chromatography

CALIBRATING GPC COLUMNS

Benefit of light scattering technologies (RALS/LALS/MALS) and multidetection characterization in life science research?

Gel Permeation Chromatography

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

Tips & Tricks GPC/SEC: Inter-Detector Delay

Macromolecular Chemistry

Polymer Analysis by Gel Permeation Chromatography

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Determination of Polymer Modifier in Asphalt

Aqueous and polar GPC/SEC columns. Product guide

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

GPC/SEC. VARIAN, INC. Engineering Polymers ANALYSIS OF ENGINEERING POLYMERS BY GPC/SEC.

One-pot polymer brush synthesis via simultaneous isocyanate coupling chemistry and grafting from RAFT polymerization

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

How to use GPC/SEC for compositional analysis

Progress toward reliable NC molecular mass distribution by GPC

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

The power of multi-detector SEC in the analysis of antibodies

AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS

How switching mobile phases can improve your OMNISEC results

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Malvern Macromolecular Solutions. Innovative Solutions in Material Characterization

GPC/SEC Start-up Kit

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Setting the Standard for Advanced GPC/SEC Systems

GPC/MS. Analysis of PET

food testing & agriculture

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Supporting Information

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

GPC / SEC Theory and Understanding

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Size exclusion chromatography of branched polymers: Star and comb polymers

SUPPLEMENTARY INFORMATION

Analysis of PEGylated Proteins with Agilent AdvanceBio SEC Columns

The ph-responsive behaviour of aqueous solutions of poly(acrylic acid) is dependent on molar mass

Supporting information

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

of Polystyrene 4-arm Stars Synthesized by RAFT- Mediated Miniemulsions.

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

Relationship of Rheological Behavior and Molecular Architecture for LDPE Designed for Extrusion Coating. Bert Nijhof Technical Paper-7603

How Molecular Weight and Branching of Polymers Influences Laser Sintering Techniques

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

SUPPORTING INFORMATION

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Setting the Standard for GPC. Complete Guide for GPC / SEC / GFC Instrumentation and Detection Technologies. The Right Instrument for Your Application

Tips & Tricks GPC/SEC: From a Chromatogram to the Molar Mass Distribution

[VIM = 4 R3 gx ( 3)

Appendix 1. GPC Characterization of Cyclic Polymers

Zwitterionic Polymerization: A Kinetic Strategy for the Controlled Synthesis of Cyclic Polylactide

Low molecular weight resins Analysis of low molecular weight. resins and prepolymers by GPC/SEC. Application compendium. Authors

GPC/SEC Column Selection & Method Development

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

MALVERN OMNISEC RESOLVE, REVEAL, REALIZE MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

MALVERN OMNISEC RESOLVE, REVEAL, REALIZE MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Field-Flow Fractionation of Macromolecules and Structures That Cannot be Characterized by Conventional GPC/SEC Techniques

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

Long-chain hyperbranched comb-block copolymers: synthesis, microstructure, rheology and thermal behavior

Effect of Molecular Structure of Side Chain Polymers on "Click" Synthesis of Thermosensitive Molecular Brushes

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

ELECTRONIC SUPPORTING INFORMATION Pentablock star shaped polymers in less than 90 minutes via

Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infinity Analytical SFC System

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

Transcription:

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System Application Note Material testing Authors Kayleigh McEwan, Rajan K. Randev, and David M. Haddleton University of Warwick Ben MacCreath Agilent Technologies, Inc. Abstract This Application Note demonstrates the use of the Agilent 1260 Infi nity Multi-Detector GPC/SEC System for the analysis of star polymers. Accurate molecular weights are calculated through the use of a Light Scattering detector and a viscometer is used to determine the number of arms. The excellent stability and sensitivity enable subtle differences in molecular density that occur between stars with differing numbers of arms to be distinguished. Star Verified for Agilent 1260 Infinity II LC GPC/SEC System

Introduction Non-linear polymers can provide a range of desirable properties over their linear counterparts, such as increased solubility, low solution viscosities, modified melt rheologies, and high levels of terminal functionality, leading to an increase in applications such as coatings, resins, flow improvers/viscosity modifiers, and drug delivery vehicles. Linear Comb/brush A range of non-linear architectures exist including branched/hyperbranched, comb/brush, dendritic/dendrimers, and stars. The density of non-linear polymers can vary across the volume of each structure depending on the type of branching architecture, and the level of branching can change depending on length of polymer chain. This makes it essential to have a technique that can separate by size while determining density in order to have a full picture of the polymer topology. GPC/SEC is the most common method to analyze polymers, and the technique can be expanded by the use of advanced detectors to provide accurate molecular weights and measure the average functionality (number of arms) of star polymers. This Application Note describes the determination of branching levels in star polymers using the 1260 Infinity Multi-Detector GPC/SEC System. Experimental Instrumentation and software Agilent 1260 Infinity Standard Degasser (G1322A) Agilent 1260 Infinity Isocratic Pump (G1310B) Agilent 1260 Infinity Standard Autosampler (G1329B) Agilent 1260 Infinity Thermostatted Column Compartment (G1316A) Agilent 1260 Infinity GPC/SEC Multi-Detector Suite (G7800A) Branched/hyperbranched Agilent 1260 Infinity MDS RID (G7801A) Agilent 1260 Infinity MDS Viscometer (G7802A) Agilent 1260 Infinity MDS Light Scattering (G7803A) Agilent GPC/SEC Software (G7850AA) Agilent GPC/SEC Multi-Detector Upgrade (G7852AA) Agilent GPC/SEC Instrument Control (G7854AA) All detectors were plumbed in series, Light Scattering to Refractive Index, Detector to Viscometer. Chromatographic conditions Dendritic/dendrimer Table 1. Chromatographic parameters used for GPC/SEC. Star Column set and calibrants 3 PLgel 5 µm Mixed-C, 7.5 300 mm (PL1110-6500) Parameters Conditions Eluent Tetrahydrofuran (stabilized with 250 ppm BHT) TCC temperature 35 C Detectors temperature 35 C Injection volume 100 µl Flow rate 1.0 ml/min Run time 35 minutes Detection Refractive Index at 660 nm Viscometer Inlet Pressure Viscometer Differential Pressure Light Scattering 15 at 660 nm Light Scattering 90 at 660 nm PS nominal Mp 100k (PL2013-5001) EasiVial PS-H 4 ml (PL2010-0200) Samples In the case of star polymers, branching is controlled by the number of arms around a central core. There are two methods for the synthesis of stars, arm first and core first. The core first approach uses a multifunctional initiator as the central core, from which polymer chains are grown from the initiating sites. The number of arms per star is controlled by the number of initiation sites per core. 2

To achieve full control over the amount of arms and to keep the length of the arms consistent, controlled/living radical polymerization techniques (LRP) were employed in the synthesis. Two multiinitiating cores, with both five and eight initiating sites were used, with the molecular weights of the resulting stars controlled by the ratio of core to arms. Samples were dissolved over a period of 3 hours in eluent at nominally 2.0 mg/ml. Calibration Standards The 1260 Infinity Multi-Detector GPC/SEC System, featuring Refractive Index, Viscometer and dual angle Light Scattering detectors was calibrated using a single polystyrene narrow standard of 113,300 g/mol -1. Although not required for this study, the column was calibrated with PS-H EasiVials to highlight difference between conventional and advanced data. Results and Discussion A range of core-first stars were synthesized utilizing living radical polymerization from multi-initiating cores with both 5-arm and 8-arm initiating sites. The ratio of monomer to core was varied in order to provide two distinct molecular weight polymers for both the 5 arm and 8 arm initiators (5-arm Low, 5-arm High, 8-arm Low, and 8-arm High). Core first star Monomer Star Multi-initiating core Response (mv) 20 18 16 14 12 10 8 6 4 2 0-2 -4-6 -8-10 -12-14 -16-18 -20 RID LS 15 LS 90 Viscometer 10 11 12 13 14 15 16 17 18 19 RT (min) 20 21 22 23 24 25 26 27 28 Fi gure 1. Raw data chromatogram showing RID, LS 15 and 90, and Viscometer responses to 5-arm Low star. 3

Molecular Weight Distribution The majority of star polymers analyzed displayed narrow Gaussian peak distributions characteristic of polymers synthesized by living radical techniques. However, some high molecular weight shoulders were apparent on certain samples, indicative of star-star coupling. This is an undesired side-reaction during the synthesis which is easily detected when looking at the molecular weight distribution from GPC/SEC. These key factors are obtained using conventional GPC however; an underestimation of the molecular weights is attained due to the star like architecture of the polymers. This applies to all stars, but the extra arms in the 8-arm star effect a more contracted hydrodynamic volume than in the 5-arm star. This is clearly seen using just the high molecular weight arm stars as example. Both the 5- and 8-arm high molecular weight stars had identical molecular weights targeted but looking at the elution volume this is not apparent, the 8-arm star elutes after the 5-arm star, indicating a lower molecular weight. The light scattering detector responds directly to molecular weight and therefore is not affected by this hydrodynamic change, thus the results from LS show near identical, much higher molecular weights (Table 2 and Figure 2). Ta ble 2. Molecular weight averages comparing conventional GPC to Triple GPC for the high molecular weight stars. Molecular weight averages (g/mol -1 ) Sample name Mp Mn Mw PD 5-arm high (Conv) 124,900 114,900 147,800 1.29 5-arm high (Triple) 219,200 206,800 249,400 1.21 8-arm high (Conv) 105,400 98,500 110,500 1.12 8-arm high (Triple) 215,900 205,200 223,500 1.09 dw/dlogm 3.6 3.4 3.2 3 2.8 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 5-arm High (Conv) 5-arm High (Triple) 8-arm High (Conv) 8-arm High (Triple) 1e5 Fitted MW (g/mol) 1e6 F igure 2. Overlaid Molecular Weight Distributions of the 5-arm and 8-arm High stars by Conventional and Triple GPC. 4

Branching Comparison of the intrinsic viscosity of a branched polymer and its linear analog over the same molecular weight range, (Figure 3) is used to obtain information on the contraction factor, g. 1e 0 Linear analog 5-arm High 5-arm Low 8-arm Low 8-arm High IV (dl/g) 1e 1 1e 5 Fitted MW (g/mol) Fi gure 3. Mark-Houwink plot from Triple analysis showing all star polymers overlaid. 1.0 0.9 0.8 5-arm High 5-arm Low 8-arm Low 8-arm High 0.7 0.6 g 0.5 0.4 0.3 0.2 0.1 0.0 1e5 Log MW Fi gure 4. Branching contraction factors for all of the star polymers. 5

Additionally, the level of functionality of star polymers can be modeled using the relationship which exists between g and number of arms (functionality). A choice of models exist for this in Agilent GPC/SEC Software, which vary, dependent on whether uniform or random architectures are obtained. LRP create stars of a regular structure, where both the number and length of arms is constant, therefore a Regular Star Branched Model was used (Figure 5). From the functionality plots, it is observed that the results obtained are close to those expected from the number of initiation sites on the two cores. All of the stars have a flat profile, indicating that the length of arms is consistent across the molecular weight distribution a key factor in the proof of a successful LRP. The 8-arm Low star polymer possesses a functionality of 8.0, which suggests that the polymerisation progressed from all eight initiation sites from the core. As more arms are targeted, steric crowding of the core can be a detrimental factor and often lower functionalities than expected are obtained due to this, therefore design of the initiator is key. Testing of the functionality is very difficult by methods other than GPC/SEC with Viscometry/Light Scattering. The 8-arm High star also displays a level of functionality close to its expected value at approximately 7.5. This, together with the deviation from linearity suggests that the polymerisation did not quite work perfectly. The functionality of the 5-arm Low is slightly lower than expected at approximately 4.0. However, the 5-arm High star displays a functionality of approximately 5.0, which again shows a high level of control over functionality. Functionality (f) 10.0 9.5 9.0 8.5 8.0 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 1e 5 1e 6 Log MW 5-arm High 5-arm Low 8-arm Low 8-arm High Figure 5. Plot to show functionality of the star polymers. 6

Conclusions The Agilent 1260 Infinity Multi-Detector GPC/SEC System provides an excellent tool to help characterize and understand advanced materials. A range of star polymers were analyzed and the true molecular weight and number of arms was calculated with excellent agreement with theoretical. This highlights the importance of not only characterizing the polymer but also validating the synthetic pathway. The market-leading low dispersion advanced detectors provided critical data with excellent signal-noise without compromising the chromatography, especially important when using advanced detectors to look at narrowly disperse polymers. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 2013-2016 Published in the USA, May 1, 2016 5991-2887EN