Basics of a/b Discrimination for Liquid Scintillation Counting

Similar documents
Time-Resolved Liquid Scintillation Counting

TIME-RESOLVED LIQUID SCINTILLATION COUNTING

Application Note. Abstract. Introduction. Experimental

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

LIQUID SCINTILLATION COUNTERS. {Beta Counters}

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS

Plastic Scintillation and dryness evaporation: a new procedure for Alpha/Beta determination in water samples

Gross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC)

Validation of detection efficiency of alpha particles in commercial liquid scintillation counters

Liquid Scintillation Counting Performance Using Glass Vials in the Wallac 1220 QuantulusTM

arxiv: v1 [physics.ins-det] 3 Feb 2011

A Rapid Procedure for Screening Transuranium Nuclides in Urine Using Actinide Resin and Low

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

RESULTS YOU CAN COUNT ON

Effect of liquid scintillating cocktail volume on 3 H and 14 C measurement parameters using a Quantulus spectrometer

Jerde, Peterson and Stein (1967) indicated that high-energy radiation

Gross alpha and beta measurements by LSC in waters: advantages, problems and limitations. Maurizio Forte Arpa Lombardia

GEMMA RAURET, J S MESTRES and J F GARCIA

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples

BUREAU INTERNATIONAL DES POIDS ET MESURES

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Primary Standardisation of I-125

High Performance Liquid Scintillation Analyzers. For Any Research, Discovery or Environmental Application Challenging Your Lab

Primary Standardization of 152 Eu by 4πβ(LS) γ (NaI) coincidence counting and CIEMAT-NIST method

Acronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second

Northwest University, Mafikeng, Centre of Applied Radiation Science & Technology (CARST), South Africa.

IMPROVED TECHNIQUES FOR THE ACTIVITY STANDARDIZATION OF 109 Cd BY MEANS OF LIQUID SCINTILLATION SPECTROMETRY

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

2100TR Liquid Scintillation Counter

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

A New Measurement Method For Tritium Rapid Detection by LSC. IM.CAEP Xu Qinghua

Activity determination of 88 Y by means of 4πβ(LS)-γ coincidence counting

COMBINED LSC-BASED METHOD FOR RADON IN AIR MEASUREMENTS

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Instrumental Limitations for High Absorbance Measurements in Noise

LSC for Quality Control of 99m TC Eluate from 99 Mo- 99m Tc Generator

LSC-BASED APPROACH FOR RADON IN SOIL GAS MEASUREMENTS. The Marzeev Institute of Hygiene and Medical Ecology 50, Popudrenko str., Kiev 02094, Ukraine.

Hyuncheol Kim*, Yoonhee Jung, Wanno Lee, Guen-Sik Choi, Kun Ho Chung, Mun Ja Kang

DETERMINING FUNDAMENTAL PARAMETERS OF A SINGLE-PHOTOTUBE LIQUID SCINTILLATION COUNTER

Counting Solutions LSC Technical Tips from PerkinElmer

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Calibration & Use of a Capintec CAPTUS 3000 Portable Thyroid Uptake System for Iodine-125 Bioassay Measurements Todd W.

CATALOG OR PART NUMBER SX SX18 4 SX20 5 SX20 SAMPLE SX20-4 SX SX21 5 SX21 SAMPLE SX22 5 SX22 SAMPLE SX23 5 SX23 SAMPLE SX24 5 SX24 SAMPLE

Standardization of Tritium by CIEMAT/NIST Method and TDCR Method

GUIDE TO LABORATORY SURVEYS. Introduction

Radiochemistry Webinars Environmental/Bioassay Radiochemistry Series Applications of Liquid Scintillation Counting

Simultaneous measurement of 89 Sr and 90 Sr in aqueous samples by liquid scintillation counting using the spectrum unfolding method

Determination of H-3 and C-14 in the frame of decommissioning projects at the Paul Scherrer Institute

Čerenkov counting and liquid scintillation counting of 36 Cl

TECHNETIUM-99 IN SOIL

arxiv: v1 [physics.ins-det] 29 Jun 2011

Determination of 210 Pb and 210 Po in Water Samples

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

Practical Approaches using TDCR Measurements and Alpha/Beta Separation

Alpha-particle Stopping Powers in Air and Argon

Digital two-parametric processing of the output data from radiation detectors

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

Figure 1. Decay Scheme for 60Co

DETECTORS. I. Charged Particle Detectors

Radio-HPLC Flow Cells

Contamination Monitoring Radiation Safety Orientation Open Source Booklet 4 (June 1, 2018)

NUCL 3000/5030 Laboratory 2 Fall 2013

HYPHENATED TECHNOLOGY GUIDE

Fundamentals of Radionuclide Metrology

RamanStation 400: a Versatile Platform for SERS Analysis

CIEMAT/NIST STANDARDIZATION METHOD EXTENDED TO ANODE OUTPUTS FOR BETA AND ELECTRON-CAPTURE NUCLIDES J. F. ORTIZ

Radiation Detection. 15 th Annual OSC Readiness Training Program.

How Histogramming and Counting Statistics Affect Peak Position Precision. D. A. Gedcke

HYPHENATED TECHNOLOGY GUIDE

LS6500 Scintillation Counting Systems

DETERMINATION OF RADON BY LIQUID SCINTILLATION a/f PARTICLE SPECTROMETRY: Towards the Resolution of a 14C Dating Problem

Radionuclide Imaging MII Detection of Nuclear Emission

ACCURATE MEASUREMENTS OF SURFACE EMISSION RATE FOR LARGE-AREA ALPHA AND BETA REFERENCE SOURCES

Overview about the Work with Liquid Scintillators

The LSC Approach to Radon Counting in Air and Water

GM Pancake Probe Victoreen Model D

Automation of the radiochemical procedures for the sequential separation of radionuclides

EVALUATION OF HIGH-PURITY SYNTHETIC SILICA VIALS IN ACTIVE AND PASSIVE VIAL HOLDERS FOR LIQUID SCINTILLATION COUNTING OF BENZENE

The TDCR method in LSC. P. Cassette Laboratoire National Henri Becquerel CEA/LNE, France

COMBINED LSC BASED METHOD FOR RADON IN AIR MEASUREMENTS

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

METHOD TEST METHODS FOR MEASURING RADIONUCLIDE EMISSION FROM STATIONARY SOURCES

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Setup for an in-situ measurement of the total light extinction of Liquid Argon in GERDA

TRITIUM DETERMINATION IN WATER

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

SCINTILLATION DETECTORS AND PM TUBES

BALANCED WINDOW METHOD IN 14 C LIQUID SCINTILLATION COUNTING. P TheodÛrsson 1 S Ingvarsdottir G I Gudjonsson

KamLAND. Studying Neutrinos from Reactor

Understanding the contribution of naturally occurring radionuclides to the measured radioactivity in AWE Environmental Samples

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

TECHNETIUM-99 IN WATER

Verification of Pharmaceutical Raw Materials Using the Spectrum Two N FT-NIR Spectrometer

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

Quality Assurance. Purity control. Polycrystalline Ingots

ISO Water quality Determination of carbon 14 activity Liquid scintillation counting method

LAAPD Performance Measurements in Liquid Xenon

Transcription:

application Note Liquid Scintillation Basics of a/b Discrimination for Liquid Scintillation Counting Author Ronald Edler, PhD and Chuck Passo PerkinElmer, Inc. 940 Winter Street Waltham, MA USA Introduction The a/b discrimination is of major importance for measurement of environmental samples and for the control of nuclear power stations. Samples in these areas often contain a and b emitters in the same sample. For the successful use of the a/b discrimination you need some experience with liquid scintillation counters and the corresponding applications. This application note describes the a/b discrimination including the pulse analysis (pulse decay analysis = PDA) but other methods of the classical scintillation technique are also important such as time-resolved liquid scintillation counting (1,2,3). are longer than b pulses (see figure 1). We already mentioned the low photon conversion rate of a particles. This is due to the fast component that contains a large amount of ionization quench and does not result in photons. The delayed component, compared to the fast component, is much larger in a decays than in b decays. The longer lifetime of signals from a particles in the electronic circuits is the basis of the a/b discrimination. a pulses can be 30-40 ns longer than b pulses. Pulse decay analysis We can detect a particles with almost 100% counting efficiency in a LSC instrument but the ratio of the number of photons formed during the scintillation process to the energy of the a particle is only 1/10 of the ratio that we observe during a b decay. Because we calibrate the energy scale of the LSC with b sources we will see an a particle at 1/10 of its energy. A 5 MeV a particle will appear at approximately 500 KeV. Therefore there will be substantial overlap of many a emitters with b particles in the multichannel analyzer, so discrimination only on the basis of the decay energy is not possible. In order to understand how the separation of a decays from b decays is accomplished, it is necessary to examine the process at a molecular level. a and b events may be distinguished from one another in a liquid scintillation counter by examining the electronic pulses that are produced at the PMT anode of the detector. (4, 5) These pulses are made up of two major components: The prompt component and the delayed component. (6) These components occur in different proportions in a and b pulses with the result that a pulses Intensity b Time Figure 1. Different pulse length of a and b pulse. a

PDA and TR-LSC Pulse decay analysis is based on the zerocross pulse timing technique. In general, a zero cross sensing circuit has consistently proven to provide excellent a/b separation. (7) The zerocross method is illustrated in figure 2 and 3. To further optimize the separation of a events from b /g decays, the anode pulses are integrated, slowed and further shaped by passing through a low pass filter. This stretches the pulses as represented graphically in figure 2. A derivative of this wave function produces a zero crossover pulse as indicated in figure 3. From this information, an optimum pulse decay discriminator (PDD) may be set between the zerocross time points of the two types of pulses. Because a and b pulses have a different pulse length, setting optimized PDD values allows separating between a and b particles. Pulses which decay in a shorter time than indicated by the PDD values will be classified as b events and consequently will be saved in the b multi channel analyzer (MCA); pulses which are longer will be saved in the a MCA. You can minimize the misclassification of a particles as b particles and vice versa. Additional background discrimination or guard detectors are not necessary for a detection. High energy cosmic rays, interacting with the scintillator, will be discriminated by the PDA in the same way as b radiation. TR-PDA (time resolved PDA) is the combined use of TR-LSC background discrimination and pulse decay analysis. By applying TR-LSC to PDA, a events misclassified as b events are discriminated by TR-LSC since the long tails (delayed component) of a pulses resemble background events. Thus, a decays misclassified as b decays will be eliminated from the b MCA. In addition, the misclassification of b decays will also be reduced since the TR-PDA causes a shift to a higher optimum PDD value. At higher PDD values, fewer b events can satisfy the time requirement for a a pulse which reduces the b spill into the a MCA. The net result of TR-PDA is a reduction of two- to five-fold in the misclassification of b and a events. Alpha/Beta calibration In order to optimize a/b separation performance, it is essential to determine the correct PDD setting as already described. On PerkinElmer TriCarb models with a/b option, the optimum setting is the setting where there is equal and minimum spill of a pulses into the b MCA and b pulses into the a MCA. Figure 2. Low pass filtered pulse processed with pulse decay analysis Figure 4 illustrates the percent spillover or percent misclassification of 241 Am and 36 Cl samples in Ultima Gold AB, a cocktail specifically designed for a/b separation. The determination of an optimum PDD requires two standards, one pure a emitter and one pure b emitter of interest. For the most accurate results, the standards must be as near identical as possible to the unknown samples in their chemistry, volume, vial type etc. For gross a und gross b measurements where the particular radionuclides may not be known, a a and b standard of similar energy to the a and b nuclides in the samples is desirable. To find the optimum PDD settings, each standard is counted individually at a range of PDD settings and the percent misclassification of a into the b MCA and vice versa are plotted against PDD on the same graph. Figure 3. Zero crossover Puls for the Determination of PDD Settings When only the b emitter is of interest, a PDD value below the instrument determined optimum may be used, which minimizes the misclassification of a activity into the b MCA at the expense of reducing the b counting efficiency. Similarly, when only the a emitter is of interest, a PDD value greater than the optimum can be used. This minimizes the misclassification of 2

a misclassified as b b misclassified as a Figure 4. Misclassification plot for the determination of optimum PDD settings b events into the a MCA at the expense of reduced a counting efficiency. As mentioned previously, the instrument determined optimum PDD is at the intersection of the two curves which corresponds to the minimum misclassification of a and b events. Factors influencing the a/b discrimination Quench We have seen how to determine the optimized PDD settings. However, a number of factors have an influence on the PDD settings and a correction of the determined PDD settings might be necessary in some cases. Strong quench in your sample may have an influence on the PDD settings. The PDD settings as well as the amount of misclassification can change with increasing quench. In general the amount of misclassification is increasing with increasing quench. Figure 5. Misclassification of 36 Cl and 241 Am without quench The optimum PDD settings for the example shown in figure 5 have been determined as 188 and the spill of a pulses into the b MCA and vice versa were 0.4% in each case. The same but heavier quenched sample can be seen in figure 6. The PDD settings as well as the misclassification have changed significantly. The optimum PDD value is now 123 and the b spill into the a MCA as well as the a spill into the b MCA is 1.15%. When the degree of quenching for a particular set of samples varies, there are two possible approaches. The first approach is to produce a single pair of a/b standards which are similar in their quench (tsie) value to the least quenched sample. Figure 6. Misclassification of 36 Cl and 241 Am with strong quench 3

The next step is to progressively quench them and reoptimize the PDD at each quench level. This produces a series of PDD values and percentage misclassifications for a range of quenching (tsie values). The degree of sample quenching in each unknown sample may then be measured by making a short count on each sample to determine the value of the tsie quench indicating parameter. Then, samples have to be counted at their individual optimum PDD conditions, which could conceivably require a separate protocol for each sample. The alternative approach is to prepare a pair of standards which are equivalent in quenching to the least quenched samples, determine the optimum PDD and then progressively quench the standards. However, in this approach, the misclassification is always determined at the original PDD setting of the least quenched sample. This allows the construction of a plot of percentage misclassification versus tsie for a single PDD setting. All samples may then be counted within a single protocol and a correction for misclassification as a function of quench is applied. This approach would be in addition to a quench curve which relates quenching to detection efficiency. Figure 7 demonstrates the construction of such a correction plot. Naphthalene improves a /b separation and reduces misclassification of Insta-Gel cocktails by acting as an intermediate in the energy transfer process between the solvent and fluor. (9,10) This route increases the production efficiency of excited fluor molecules. Figure 9 illustrates the improvement in separation which is obtained when 20% naphthalene is added to Insta-Gel. Other cocktails, such as the Ultima Gold series of cocktails, are based on diisopropylnaphthaline (DIPN). These cocktails have some advantages over fast classical cocktails with 20% naphthalene. Ultima Gold is non-toxic, non-flammable and biodegradable, and is therefore preferable in cocktail manufacture to naphthalene. (11) Ultima Gold AB, the first cocktail specifically developed for a /b discrimination applications, has also exhibited superior a /b separation compared to fast cocktails with 20% naphthalene, and has an excellent water and acid holding capacity. Table 1 indicates that the addition of Ultima Gold F (UG F) to samples in Ultima Gold AB reduces the misclassification. However, this reduction of misclassification will be achieved at the expense of a lower sample uptake capacity because we replace the emulsifying cocktail UltimA Gold AB with a pure Cocktails Above we discussed that some mathematical operations are necessary to separate a from b pulses. Standard cocktails for b-counting applications which employ fast solvents, such as xylene, pseudocumene, toluene and alkylbenzenes, are less efficient for separating a from b activity. Figure 8 illustrates the misclassification of 238 Pu and 90 Sr/ 90 Y which was achieved using the old InstaGel (xylene cocktail, todays Insta-Gel Plus is based on pseudocumene). This would be a typical misclassification value for a cocktail employing a fast solvent. To overcome the poor separation, 20% naphthalene has been added to standard cocktails for a /b separation applications. (8) Figure 8. Misclassification of 238 Pu and 90 Sr/ 90 Y in Insta-Gel Figure 7. Influence of quench on the misclassification Abb. 9. Misclassification of 238 Pu and 90 Sr/ 90 Y in Insta-Gel + 20% Naphthalin 4

Sample Type Ultima 85 Vol % UG AB, 75 Vol % UG AB, 50 Vol % UG AB, Gold AB 15 Vol % UG F 25 Vol % UG F 50 Vol % UG F Water Sample uptake 0,2-10,0 ml 0,2-10,0 ml 0,2-2,25 ml 0,2-0,5 ml Misclassification 0,74-1,87% 0,70-1,74% 0,58-0,68% 0,42-0,47% 1 M HCL Sample uptake 0,2-5,5 ml 0,2-2,0 ml 0,2-1,25 ml 0,2-0,4 ml Misclassification 0,87-1,73% 0,64-0,79% 0,64-0,75% 0,43-0,52% 2 M HCL Sample uptake 0,2-2,25 ml 0,2-1,25 ml 0,2-1,0 ml 0,2-0,3 ml Misclassification 0,61-1,07% 0,56-0,76% 0,49-0,60% 0,38-0,49% 1 M HNO 3 Sample uptake 0,2-3,25 ml 0,2-1,75 ml 0,2-1,25 ml 0,2-0,4 ml Misclassification 0,75-3,85% 0,66-1,51% 0,55-0,98% 0,48-0,53% 2 M HNO 3 Sample uptake 0,2-2,25 ml 0,2-1,5 ml 0,2-1,0 ml 0,2-0,3 ml Misclassification 0,77-4,21% 0,60-1,91% 0,70-1,17% 0,54-0,62% Table 1. Uptake capacity of UG AB/UG F and corresponding misclassifications organic cocktail Ultima Gold F. Therefore the uptake capacity for aqueous and strong ionic solutions will be reduced drastically with an increasing amount of Ultima Gold F. Sample volume Several experiments have been performed to determine the effect of sample volume on a /b separation. The Plots were acquired with 36 Cl and 241 Am in Insta-Gel + 20% naphthalene. The percentage misclassification and optimum PDD values are presented in table 2. These demonstrate virtually constant PDD over the entire volume range and only a small increase in the misclassification at the 1 and 2 ml volumes. However, this can be accounted for by the increasing importance of the background count rate in the misclassification calculation since background subtraction is not performed in the calculation of the misclassification spill plot. Vial type Table 3 illustrates the change in percentage misclassification of events over a period of 24 days using a- and b-standards prepared in 7 ml and 20 ml glass vials, 20 ml plastic vials and 20 ml low diffusion vials (PerkinElmer low diffusion vials are specially prepared polyethylene vials with a thin Teflon -like inner coating). There appears to be no significant difference in performance between standard 7 ml and 20 ml glass vials, and no Sample volume (ml) Alpha Spill (%) Beta Spill (%) Optimum PDD Settings 16 0,69 0,70 101 10 0,65 0,62 101 8 0,64 0,57 101 4 0,68 0,67 101 2 0,85 0,74 100 1 1,14 1,02 98 Table 2. Dependency of PDD and %Spill on the volume 5

Days after sample formulation Percentage misclassification of a particles in the b MCA/b particles in the a MCA 20 ml Glass Vial 7 ml Glass vial 20 m Plastic vial 20 ml low diffusion vial 0 0,47/0,51 0,56/0,58 0,56/0,65 0,46/0,53 1 0,42/0,51 0,49/0,62 0,59/0,90 0,43/0,61 2 0.49/0,51 0,48/0,62 0,96/1,01 0,53/0,63 6 0,41/0,55 0,47/0,55 1,39/1,51 0,68/0,81 9 0,38/0,51 0,43/0,54 1,61/1,78 0,96/0,95 16 0,41/0,49 0,46/0,56 1,94/2,24 1,22/1,28 24 0,49/0,51 0,49/0,54 2,18/2,53 1,40/1,67 Table 3. a/b misclassification as a function of time and vial type. change in misclassification over time. On the other hand, the misclassification from standard plastic vials systematically increases throughout the time-course of the experiment. The low diffusion vials are similar in response to plastic vials except that there is a lag period of about two days before there is an increase in misclassification. The effect of the plastic vials is due to diffusion of some component into the vial wall, since decanting the vial contents into a glass vial restores the misclassification to that which is typically observed in a glass vial. The diffusion of cocktail into the plastic wall results in a stretching of the beta pulses which is known for solid scintillators, thus reducing the difference in the pulse length between a and b pulses. Further improvement can be obtained by etching the inner wall of glass vials. Etching the vials improves the light output and thus improves the ability to separate a and b events. This procedure also improves the spectral resolution. Literature 1.) PerkinElmer LAS (Germany) GmbH, 63110 Rodgau- Jügesheim, LSC Application note 4, Environmental Sample Preparation for LSC, July 2004. 2.) PerkinElmer LAS (Germany) GmbH, 63110 Rodgau- Jügesheim, LSC Application note 11, Time Resolved Liquid Scintillation Counting (TR-LSC) in TriCarb Models from PerkinElmer LAS, July 2004. 3.) PerkinElmer LAS (Germany) GmbH, 63110 Rodgau- Jügesheim, LSC Application note 15, TR-LSC with Delay before Burst, October 2006. 4.) J. H. Thorngate; W. J. McDowell; D. J. Christian; An application of pulse shape discrimination to liquid scintillation counting, Health Physics, 27, 123-126 (1974). 5.) J. W. McKlveen; W. R. Johnson; Simultaneous counting of low alpha and beta particle assay using liquid scintillation counting with pulse shape discrimination, Health Physics, 28, 5-11 (1975). 6.) D. L. Horrocks; Applications of Liquid Scintillation Counting, New York, Academic Press, 1974. 7.) W. J. McDowell, B. L. McDowell; Liquid Scintillation Alpha Spectrometry, CRC Press, 1994. 8.) T. Oikari, H. Kojola, J. Nurmi, L. Kaihola; Simultaneous counting of low alpha and beta particle activities with liquid scintillation spectrometry and pulse shape analysis, J. Appl. Rad. Isot. 38, 875-878 (1987). 9.) F. D. Brooks; Development of organic scintillators, Nucl. Instr. Meth. 162, 477-505 (1979). 10.) W. J. McDowell; Alpha counting and spectrometry using liquid scintillation methods, Nuclear Sciences Series on Radiochemical Techniques, 1986. 11.) J. Thomson; Diisopropylnaphthalene a new solvent for liquid scintillation counting. In Liquid Scintillation Counting and Organic Scintillators, ed. H. Ross, J. E. Noakes, J. D. Spaulding, Lewis Publishers, 19-34 (1991). PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2007-2010, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009379_01 Oct. 2010