Test Report issued under the responsibility of: UL International Italia srl TEST REPORT IEC 62471 Photobiological safety of lamps and lamp systems Report Reference No.... : 10CA36788M2 Date of issue... : 2010-09-27, Amendment No. 2: 2010-11-26 Total number of pages... : 10 CENELEC Common Modifications.. : Annex (1), 3 pages Labeling requirement Photographs... : Annex (3), 1 page Annex (4), 2 pages Testing Laboratory... : Address... : Tested by (name + signature)... : Istituto Masini S.r.l. a Third Party Test Data Program (TPTDP) laboratory under Underwriters Laboratories Inc Via Moscova, 11 I-20017 Rho (MI) Elena Re (Ist. Masini) Approved by (name+ signature). : Vincenzo La Fragola (Ist. Masini) Reviewed by (name + signature).: Applicant s name... : Walter Parmiani (UL Int. Italia) Cor Light srl Gmbh Address... : Via dell'adige Etschweg 15 Test specification: 39040 Cortaccia Kurtatsch (BZ) Standard... : IEC 62471:2006 (First Edition) Test procedure... : Non-standard test method..: Test Report Form No.... : TRF Originator... : IEC62471A UL International Italia S.r.l. Master TRF... : Dated 2010-02 Test item description... : Trade Mark... : Manufacturer... : Model/Type reference... : Ratings... : cor light Cor Light DS31, DS32 street and DP31 area, 3x3 XP-G 139 lm 700mA 21,6 W
Page 2 of 4 Report No.: 10CA36788M2 Summary of testing: Tests performed (name of test and test clause): Testing location: 5.2.1 Irradiance measurements Applicable Istituto Masini 5.2.2 Radiance measurements Applicable S.r.l. Summary of compliance with National Differences: This test report was issued for classifying evaluation of potential radiation hazards that may be associated with various lamps and lamp systems only Copy of marking plate:
Page 3 of 4 Report No.: 10CA36788M2 Test item particulars... : Tested lamp... : continuous wave lamps pulsed lamps Tested lamp system... : See component list on additional remarks Lamp classification group (200mm)... : exempt risk 1 risk 2 risk 3 Lamp classification group (500lux)... : exempt risk 1 risk 2 risk 3 Lamp system classification group... exempt risk 1 risk 2 risk 3 Lamp cap... : See component list on additional remarks Bulb... : See component list on additional remarks Rated of the lamp... : See component list on additional remarks Furthermore marking on the lamp... : - Seasoning of lamps according IEC standard... : Used measurement instrument... : See measurement equipment list Temperature by measurement... : 20 C Information for safety use... : - Possible test case verdicts: test case does not apply to the test object... : test object does meet the requirement... : P (Pass) test object does not meet the requirement... : F (Fail) Testing: Date of receipt of test item... : 2010-07-21 Date (s) of performance of tests... : 2010-07-27 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. List of test equipment must be kept on file and available for review. Amendment 1 Report: The original Test Report Ref. No. 10CA36788, dated 2010-09-27 was modified on 2010-10-19 to include the following changes and/or additions, which were considered technical modifications: Addition of new model DS31 with tests. Amendment 2 Report: The Amendment of Test Report Ref. No. 10CA36788, dated 2010-10-19 was modified on 2010-11-26 to include the following changes and/or additions, which were considered technical modifications: Correction of model references, trademark and marking plates. No additional tests were considered necessary.
Page 4 of 4 Report No.: 10CA36788M2 General information : Description Nr Manufacturer Type model Ratings / Technical data Led 3X3 Cree XP-G, cool white 139 Lm 6000 K LED control gear 1 - Luminaire was supplied by an appropriate control gear delivering Constant current of 700 ma Fwd Voltage 3,0 V (typical) Max Fwd Current 1500 ma Lens Cor Light PMMA --
Page 1 of 3 Report No.: 10CA36788M2 ANNEX 1 CENELEC COMMON MODIFICATIONS DP 31 area, at a distance which produces an illuminance of 500 lux : Table 6.1a : Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) Risk Action spectrum Symbol Units Emission Measurement Exempt Low risk Mod risk Limit Result Limit Result Limit Result Actinic UV S UV (λ) E s W m -2 0,001 <0,0001 - - - - Near UV E UVA W m -2 0,33 1,8*10-3 - - - - Blue light B(λ) L B W m -2 sr -1 100 54,53 10000 4000000 Blue light, small source Retinal thermal B(λ) E B W m -2 0,01* 1,0 400 R(λ) L R W m -2 sr -1 28000/α = 25455 10 3 5569,2 28000/α 71000/α 545000 Retinal thermal, weak visual stimulus** R(λ) L IR W m -2 sr -1 0,0017 α 0,011 6000/α 0,011 α 0,1 IR radiation, eye E IR W m -2 100 2,04 570 3200 * Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian. ** Involves evaluation of non-gls source NOTE The action functions: see Table 4.1 and Table 4.2 The applicable aperture diameters: see 4.2.1 The limitations for the angular subtenses: see 4.2.2 The related measurement condition 5.2.3 and the range of acceptance angles: see Table 5.5.
Page 2 of 3 Report No.: 10CA36788M2 ANNEX 1 CENELEC COMMON MODIFICATIONS DS32 street, at a distance which produces an illuminance of 500 lux : Table 6.1a : Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) Risk Action spectrum Symbol Units Emission Measurement Exempt Low risk Mod risk Limit Result Limit Result Limit Result Actinic UV S UV (λ) E s W m -2 0,001 <0,0001 - - - - Near UV E UVA W m -2 0,33 2*10-3 - - - - Blue light B(λ) L B W m -2 sr -1 100 64,82 10000 4000000 Blue light, small source Retinal thermal B(λ) E B W m -2 0,01* 1,0 400 R(λ) L R W m -2 sr -1 28000/α = 25455 10 3 15266,93 28000/α 71000/α 545000 Retinal thermal, weak visual stimulus** R(λ) L IR W m -2 sr -1 0,0017 α 0,011 6000/α 0,011 α 0,1 IR radiation, eye E IR W m -2 100 2,65 570 3200 * Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian. ** Involves evaluation of non-gls source NOTE The action functions: see Table 4.1 and Table 4.2 The applicable aperture diameters: see 4.2.1 The limitations for the angular subtenses: see 4.2.2 The related measurement condition 5.2.3 and the range of acceptance angles: see Table 5.5.
Page 3 of 3 Report No.: 10CA36788M2 ANNEX 1 CENELEC COMMON MODIFICATIONS DS31 street, at a distance which produces an illuminance of 500 lux : Table 6.1a : Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) Risk Action spectrum Symbol Units Emission Measurement Exempt Low risk Mod risk Limit Result Limit Result Limit Result Actinic UV S UV (λ) E s W m -2 0,001 <0,0001 - - - - Near UV E UVA W m -2 0,33 0,13*10-3 - - - - Blue light B(λ) L B W m -2 sr -1 100 93,06 10000 4000000 Blue light, small source Retinal thermal B(λ) E B W m -2 0,01* 1,0 400 R(λ) L R W m -2 sr -1 28000/α = 25455 10 3 155,38 28000/α 71000/α 545000 Retinal thermal, weak visual stimulus** R(λ) L IR W m -2 sr -1 0,0017 α 0,011 6000/α 0,011 α 0,1 IR radiation, eye E IR W m -2 100 2,05 570 3200 * Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian. ** Involves evaluation of non-gls source NOTE The action functions: see Table 4.1 and Table 4.2 The applicable aperture diameters: see 4.2.1 The limitations for the angular subtenses: see 4.2.2 The related measurement condition 5.2.3 and the range of acceptance angles: see Table 5.5.
Page 1 of 1 Report No.: 10CA36788M2 ANNEX 3 LABELING REQUIREMENT DS31, DS32 street and DP31 area, at a distance which produces an illuminance of 500 lux : Table 1 Hazard Hazard-related risk group labelling of lamps systems Exempt Risk Group Ultraviolet hazard 200-400 nm Not required NOTICE UV emitted from this Group Risk 1 Group Risk 2 Group Risk 3 CAUTION UV emitted from this Retinal blue light hazard 300-700 nm Not required Not required CAUTION Possibly hazardous optical radiation emitted from this Retinal thermal hazard 380-1400 nm Not required Not required CAUTION Possibly hazardous optical radiation emitted from this Cornea/Lens infrared hazard 780-3000 nm Not required NOTICE IR emitted from this Retinal/thermal hazard, weak visual stimulus 780-1400 nm Not required NOTICE IR emitted from this NOTICE IR emitted from this NOTICE IR emitted from this WARNING UV emitted from this CAUTION Possibly hazardous optical radiation emitted from this CAUTION Possibly hazardous optical radiation emitted from this NOTICE IR emitted from this NOTICE IR emitted from this
Page 1 of 2 Report No.: 10CA36788M2 ANNEX 4 PHOTOGRAPHS Photograph No. 1 : DP31 area; Photograph No. 2 : DS32 street
Page 2 of 2 Report No.: 10CA36788M2 ANNEX 4 PHOTOGRAPHS Photograph No. 3: DS31 area;