R I B E L E M E N T S

Similar documents
S TRUCTUR A L PR E- A N A LYSIS TA B LES

Design of AAC wall panel according to EN 12602

Basic and Special Design Concepts of CLT Elements loaded out-of-plane

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

TECHNICAL REPORT. Bending tests on glulam-clt beams connected with double-sided punched metal plate fasteners and inclined screws.

D DAVID PUBLISHING. Cable-Stay Bridges Investigation of Cable Rupture. 1. Introduction. 2. Basic Conditions. Nguyen Trong Nghia 1 and Vanja Samec 2

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

Theory of structure I 2006/2013. Chapter one DETERMINACY & INDETERMINACY OF STRUCTURES

2D - STRIP ANCHOR LIFTING SYSTEM

Structural Steelwork Eurocodes Development of A Trans-national Approach

Entrance exam Master Course

STRUCTURAL ANALYSIS CHAPTER 2. Introduction


FRAME ANALYSIS. Dr. Izni Syahrizal bin Ibrahim. Faculty of Civil Engineering Universiti Teknologi Malaysia

Underlayment. bonded impact sound insulation

WE COVER EVERYTHING UNDER THE SUN DOME STRUCTURES TIMBER-ZERO CARBON

Case Study in Reinforced Concrete adapted from Simplified Design of Concrete Structures, James Ambrose, 7 th ed.

Structural Calculations for Juliet balconies using BALCONY 2 System (Aerofoil) handrail. Our ref: JULB2NB Date of issue: March 2017

STRUCTURAL CALCULATIONS

ENG1001 Engineering Design 1

Product description. Compact Modules. Characteristic features. Further highlights

ΙApostolos Konstantinidis Diaphragmatic behaviour. Volume B

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German

From Table 1 4. DL = [12 lb/ft 2 # in.(6 in.)] (15 ft)(10 ft) = 10,800 lb. LL = (250 lb/ft 2 )(15 ft)(10 ft) = 37,500 lb.

Example 2.2 [Ribbed slab design]

Beam Design - Shed Roof Back Wall Beam-S

A HIGHER-ORDER BEAM THEORY FOR COMPOSITE BOX BEAMS

Lamp and Control Panel (Lamp Panel)

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Job No. Sheet No. Rev. CONSULTING Engineering Calculation Sheet. Member Design - Steel Composite Beam XX 22/09/2016

Long Carbon Europe Sections and Merchant Bars. Angelina TM beams. A new generation of castellated beams

Modeling the elastic properties of paper honeycomb panels using the finite element method

Design of Reinforced Concrete Structures (II)

8.6 Product data sheet

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: PNEUTEK, INC.

Design of reinforced concrete sections according to EN and EN

Krantz. RL-C2 radial slot outlet. Air distribution systems

COPPER FOR BUSBARS CHAPTER 4: SHORT-CIRCUIT EFFECTS

twenty one concrete construction: shear & deflection ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture

Special edition paper

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

9-3. Structural response

Parametric study on the transverse and longitudinal moments of trough type folded plate roofs using ANSYS

Design of AAC floor slabs according to EN 12602

Serviceability Limit States

THE LEADING TECHNOLOGY IN STANDARDIZED TIMBER CONNECTION SYSTEMS. SHERPA Manual. SHERPA Connection Systems

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER: NEW MILLENNIUM BUILDING SYSTEMS, LLC

8.1 Product data sheet

Design of Beams (Unit - 8)

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

FLEXIBILITY METHOD FOR INDETERMINATE FRAMES

Section Downloads. Design Process. Design Principles Outline. Basic Design Principles. Design Process. Section 06: Design Principles.

Structural, Snow & Wind Loading Appraisal Report

a 1 ft2 144 in 2 b 26 in.

Codal Provisions IS 1893 (Part 1) 2002

MECHANICS OF STRUCTURES SCI 1105 COURSE MATERIAL UNIT - I

Compression perpendicular to the grain

1 Introduction to shells

Made by PTY/AAT Date Jan 2006

Engineeringmanuals. Part2

STRENGTH AND STIFFNESS OF CROSS LAMINATED TIMBER AT IN-PLANE BEAM LOADING. HENRIK DANIELSSON, MARIO JELEC and ERIK SERRANO. Structural Mechanics

A fire resistance assessment case history G.C. and M.E. Giuliani

2012 MECHANICS OF SOLIDS

External Pressure... Thermal Expansion in un-restrained pipeline... The critical (buckling) pressure is calculated as follows:

This equation of motion may be solved either by differential equation method or by graphical method as discussed below:

Bridge deck modelling and design process for bridges

Beam Design - Trotin Project

EFFECTS OF SELF-TAPPING SCREWS AS REINFORCEMENTS IN BEAM SUPPORTS ON THE DETERMINATION OF THE GLOBAL MODULUS OF ELASTICITY IN BENDING

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

ISO 178 INTERNATIONAL STANDARD. Plastics Determination of flexural properties. Plastiques Détermination des propriétés en flexion

Concentrated load introduction in CLT elements perpendicular to plane

Chapter 7: Bending and Shear in Simple Beams

Assignment 1 - actions

Physics 8 Monday, November 23, 2015

PASSIVE COOLING DESIGN FEATURE FOR ENERGY EFFICIENT IN PERI AUDITORIUM

2D - STRIP ANCHOR LIFTING SYSTEM

Analysis of Shear Lag Effect of Box Beam under Dead Load

Longitudinal strength standard

MATERIAL PROPERTIES test methods comment

Hilti North America Installation Technical Manual Technical Data MI System Version

Design of Earthquake-Resistant Structures

Feasibility of dynamic test methods in classification of damaged bridges

Installation guide 862 MIT / MIR

CO~RSEOUTL..INE. revisedjune 1981 by G. Frech. of..a.pqij~t(..~ttsa.fidteconol.q.gy. Sault ",Ste'...:M~ri,e.: SAUl. ir.ft\,nl~t';~l' G ". E b:.

CHAPTER 5. T a = 0.03 (180) 0.75 = 1.47 sec 5.12 Steel moment frame. h n = = 260 ft. T a = (260) 0.80 = 2.39 sec. Question No.

DESIGN OF STAIRCASE. Dr. Izni Syahrizal bin Ibrahim. Faculty of Civil Engineering Universiti Teknologi Malaysia

CHARACTERIZING INFLUENCE OF LAMINATE CHARACTERISTICS ON ELASTIC PROPERTIES OF CROSS LAMINATED TIMBER

IPRO 335. Flying into a New Generation of Design

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Subject code/name: ME2254/STRENGTH OF MATERIALS Year/Sem:II / IV

Type approval granted by the Finnish Ministry of the Environment

DIF SEK. PART 5a WORKED EXAMPLES. DIFSEK Part 5a: Worked examples 0 / 62

Linear guide drives. Synchronous shafts The use of synchronous shafts enables several linear axes to be operated with one drive.

Application nr. 7 (Connections) Strength of bolted connections to EN (Eurocode 3, Part 1.8)

Fundamentals of Structural Design Part of Steel Structures

Rigid Pavement Mechanics. Curling Stresses

Due Tuesday, September 21 st, 12:00 midnight

Earthquake Loads According to IBC IBC Safety Concept

NTNU Faculty of Engineering Science and Technology Department of Marine Technology TMR 4195 DESIGN OF OFFSHORE STRUCTURES

T V P M L R O G W. Sylomer. Material: Colour: Standard Sylomer range. mixed cellular polyurethane brown

Concrete and Masonry Structures 1 Office hours

Transcription:

M a d e f o r b u i l d i n g b u i l t f o r l i v i n g R IB ELEMENTS

I M P R I N T KLH Massivholz GmbH Publisher and responsible for content: KLH Massivholz GmbH Version: 01/2014, Rib Elements The content of this brochure is the intellectual property of the company and is protected by copyright. The statements are recommendations and suggestions only; liability on the part of the publisher is excluded. Any type of reproduction is strictly forbidden and only permitted after written approval from the publisher.

C O N T E N T 01 PR ODUCT DESCRIP TION, ARE A S OF APPLICATION AND ADVANTAGES 02 02 CONSTRUCTION AND CALCUL ATION 06 03 STRUCTUR AL PRE- ANALYSIS TABLE, floor sl ab SINGLE- SPAN GIRDER 10 04 STRUCTUR AL PRE- ANALYSIS TABLE, R OOF SINGLE- SPAN GIRDER 14 0 1

P R O D U C T D E S C R I P T I O N, A R E A S O F A P P L I C A T I O N A N D A D V A N T A G E S rib elements 01 PRODUCT DESCRIPTION. AREAS OF APPLICATION AND ADVANTAGES KLH rib elements provide architects and planners with additional freedom in the design and realisation of longspan rooms. From spans of about 6 m and more, the combination of rib and panel as composite cross-section usually offers more effective and more economical solutions. Moreover, this lightweight type of construction hardly adds any additional weight to a building due to its slim constructional design. The preferred arrangement of the ribs is on the lower side of the KLH solid wood panel. Depending on individual preferences, the area of application or requirements as to the visual appearance, the ribs can also be arranged on the upper side of the KLH solid wood panel. MAIN ADVANTAGES Architectural freedom of design Flexible room concepts Free bridging of long spans Space between ribs can be used Lightweight construction with usable space between the ribs Free from pillars and trussed beams Economically sound solution... Use of KLH rib elements at an event hall 0 2

P R O D U C T D E S C R I P T I O N. A R E A S O F A P P L I C A T I O N A N D A D V A N T A G E S THE USEFUL SPACE IN BETWEEN The space between the ribs can be used in order to route various installations, but it is also suitable for the installation of acoustic or decorative elements. As can be seen in figures 1 and 2, it can be flush with the rib or in a recessed variant. Especially for public buildings such as school buildings, the requirements for pleasant room acoustics are much easier to fulfil this way. FREELY SELECTABLE DIMENSIONS Fig. 1: Room between ribs with acoustic element - variant flush with the surface The dimensions of KLH rib elements can be freely selected. There are no restrictions whatsoever in terms of dimensions or thickness of the elements. The only thing that needs to be taken into consideration is the maximum size of the KLH solid wood panel with its length of 16.5 m and width of 2.95 m, as well as the transport options for an economically sound delivery to the construction site. Fig. 2: Room between ribs with acoustic element recessed variant Acoustic element variants in the space between the ribs 0 3

P R O D U C T D E S C R I P T I O N, A R E A S O F A P P L I C A T I O N A N D A D V A N T A G E S PRODUCTION KLH rib elements are delivered to the construction site in the form of completely prefabricated elements. Glued laminated spruce timber is the preferred type of wood for the ribs. Both the ribs as well as the KLH solid wood panels used have proven to meet the requirements of the E1 formaldehyde emission class. CROSS - SECTIONAL DESIGN The preferred cross-sectional designs are either rib elements with slim edge ribs and element joints in the areas of the ribs or T-elements with floating element joints between the ribs. The production of this composite unit is subject to strict quality controls based on the ÖNORM EN 14080:2013 for a permanent and reliable glued connection between ribs and panel. It is also possible to produce the elements with an additional elevation according to the structural requirements. Fig. 3: Cross-sectional design for connections with top board Both the glued laminated timber ribs and the KLH solid wood panels can be installed in visible and non-visible quality. A mixture of surface qualities such as panels in non-visible quality and ribs in visible quality is also possible. Fig. 4: Cross-sectional design for connections with stepped joint The manipulation is carried out using certified hoisting systems both during pre-manufacturing as well as during the installation at the construction site. TR ANSPORT The elements are best transported lengthwise and horizontally. If the rib elements are very high, it is reasonable to design the elements asymmetrically and to interlace them in pairs in order to optimise transport. Finished rib elements, ready for transport 0 4

0 5 eos-af (estudio Orpinell & Sanchez artesania fotogràfica)

C O N S T R U C T I O N A N D C A L C U L A T I O N 02 CONSTRUCTION AND CALCUL ATION EFFECTIVE WIDTH The glued connection between rib and panel is a rigid connection. It must be taken into account that the top layer of the KLH solid wood panel must always run in the direction of the glued laminated timber ribs. The structural calculation of rib elements is performed according to the compound theory in consideration of the shear elasticity of the transverse layers of the KLH solid wood panel. The dimensioning is based on a net cross-section that consists of the cross-section of the ribs and the crosssection of the longitudinal layers of the KLH solid wood panel. The contributing panel width of the KLH solid wood panel depends on a number of factors such as the distance between ribs and its relation to the span and the type of load (uniformly distributed load or concentrated load). Concerning this topic, reference can also be made to the latest research results of the Competence Centre at holz.bau forschungs GmbH at the Graz Technical University that has carried out in-depth research on the scientific determination of the effective width. b b b b ef f h a a Fig. 5: Dimensions of the T-beam cross-section For an economical dimensioning of the KLH rib elements we recommend selecting the distance between the axes of the ribs for slab elements in the range between 40 to 60 cm as well as for roof elements in the range between 60 to 120 cm. Each element requires at least 2 ribs. You can use our KLH structural pre-analysis software available for download at www.klh.at so you can predimension KLH rib elements quickly and easily. 0 6

C O N S T R U C T I O N A N D C A L C U L A T I O N TR ANSVERSE CONNECTION OF ELEMENTS The detailed design of the element transverse connection is best selected in a way that the rib elements can be connected at the construction site by means of simple screw connections. The transverse connection can either be a stepped joint or top board connection. S T E P P E D J O I N T C O N N E C T I O N These shear-resistant connections couple the individual elements to form a structurally effective floor slab or roof diaphragm. If vertical, differential forces can be expected to build up between the elements, then an additional crosswise screw connection of elements is usually made in the joint by means of self-drilling, fully-threaded screws. Fig. 6: Element connection with screw- connected stepped joint T O P B O A R D C O N N E C T I O N Fig. 7: Element connection with screw- connected top board eos-af (estudio Orpinell & Sanchez artesania fotogràfica) Making of transverse connections 0 7

0 8 eos-af (estudio Orpinell & Sanchez artesania fotogràfica)

C O N S T R U C T I O N A N D C A L C U L A T I O N DETAILED DESIGN AT THE SUPPORT S U P P O R T S E T T I N G S The high load-bearing capacity of the KLH rib elements. especially with regard to the bending stiffness and strength in the field area, is due to both the panel and the rib. The greatest transverse forces, and therefore also the greatest shear stress, build up in the area of the supports. These forces are almost exclusively absorbed by the ribs. It is therefore important to design the supports of rib elements in a way that the elements are directly supported by the ribs. As regards the detailed design, it must be taken into account that volume changes due to swelling or shrinking of wood in case of changes in the moisture of the wood are possible without causing any damage. Fig. 8: Adjusted opening for the ribs in the wall element In some cases it might be necessary that only the panel is rested on the support and that the ribs already end before the support and will not actually be supported themselves (e.g. if space is required for transverse installations along the wall). In such cases, thicker KLH solid wood panels must be chosen, because they are able to transmit the transverse forces onto the support. Furthermore, additional transverse force reinforcements between rib and panel must be installed at the rib ends in order to ensure a permanent connection in the glue joint. Fig. 9: Support of ribs at the wall element with suitable filling of the space in between For more detailed information, please contact our technical customer support. Fig. 10: Support of the slab against the wall. The ribs are fixed against the wall element with suitable connectors 0 9

S T R U C T U R A L P R E - A N A LY S I S T A B L E S 03 KLH RIB ELEMENT AS A floor slab SINGLE-SPAN GIRDER 3.1 VIBR ATION TEST FOR LOW REQUIREMENTS Minimum panel thicknesses for R 0 (cold dimensioning) n k g k according to ETA-06/0138:2017 ÖNORM EN 1995-1-1:2009 and ÖNORM B 1995-1-1:2014 ÖNORM EN 1995-1-2:2011 and ÖNORM B 1995-1-2:2011 l Constant load Imposed load REQUIRED RIB HEIGHT [mm] FOR A SPAN OF l k k [kn/m²] KAT [kn/m²] 6.00 m 7.00 m 8.00 m 9.00 m 10.00 m A 2.00 1.00 2.80 160 200 240 280 3.00 B 3.50 C 320 200 240 280 5.00 400 A 2.00 2.80 160 160 200 200 240 240 320 320 3.00 400 B 3.50 C 280 280 200 200 240 240 5.00 320 320 400 320 A 2.00 200 200 240 2.00 2.80 160 160 280 320 3.00 400 B 280 3.50 240 240 C 400 200 200 320 320 5.00 280 280 440 A 2.00 160 160 2.50 2.80 240 240 280 320 3.00 320 440 B 200 200 3.50 C 280 280 320 5.00 240 240 400 400 440 320 A 2.00 3.00 2.80 200 200 240 240 280 320 400 3.00 400 480 B 3.50 C 320 240 240 280 280 5.00 400 440 Dry screed Wet screed *) in addition to the rib elements own weight (the rib elements own weight is already taken into account in the table) 1 0

S T R U C T U R A L P R E - A N A LY S I S T A B L E S KLH 3s 108 DL 108 mm h BSH = acc. to table b BSH = 140 mm a = 600 mm Service class 2 k def = 0.8 Imposed load categories A and B (ψ 0 = 0.7 and ψ 2 = 0.3): k mod = 0.8 Imposed load category C (ψ 0 = 0.7 and ψ 2 = 0.6): k mod = 0.9 Deflection limits according to ÖNORM EN 1995-1-1:2009 a) characteristic structural design situation: w Q.inst l/400 and (w fin w G.inst ) l/250 b) quasi-permanent structural design situation: w fin l/300 Vibration test according to ÖNORM B 1995-1-1:2014 a) floor slab class II: slab within the utilisation unit (e.g. detached house); floating wet screed (even without filler); dry screed, floating on heavy filler (at least 60 kg/m²) b) Limit value of the frequency and stiffness criterion: f 1.min 4.5 Hz; f 1 f gr = 6 Hz; w stat w gr = 0.50 mm c) Attenuation factor for cross-laminated timber floor slabs with floating screed and heavy floor structure: ζ = 4.0 % d) Limit value acceleration (required at f 1.min f 1 f gr ): a rms a gr = 0.10 m/s² Load-bearing capacity a) Test of bending stress b) Test of shear stress Structural fire design (one-sided burn-off on panel, 3-sided burn-off on rib) The fire analysis is currently not taken into account in the structural pre-analysis tables. According to our experience, the specified building components achieve a fire resistance of at least REI 30. Higher fire resistance classes require additional measures (increase of board or rib dimensions, panelling of essential building components). This table is only intended for structural pre-analysis purposes and does not replace necessary structural calculations! 1 1

S T R U C T U R A L P R E - A N A LY S I S T A B L E S 3. 2 VIBR ATION TEST FOR INCRE ASED REQUIREMENTS Minimum panel thicknesses for R 0 (cold dimensioning) n k g k according to ETA-06/0138:2017 ÖNORM EN 1995-1-1:2009 and ÖNORM B 1995-1-1:2014 ÖNORM EN 1995-1-2:2011 and ÖNORM B 1995-1-2:2011 l Constant load Imposed load REQUIRED RIB HEIGHT [mm] FOR A SPAN OF l [kn/m²] KAT [kn/m²] A 2.00 2.80 1.00 3.00 B 3.50 C 5.00 A 2.00 2.80 3.00 B 3.50 C 5.00 A 2.00 2.80 2.00 3.00 B 3.50 C 5.00 A 2.00 2.80 2.50 3.00 B 3.50 C 5.00 A 2.00 2.80 3.00 3.00 B 3.50 C 5.00 g k *) n k 6.00 m 7.00 m 8.00 m 9.00 m 10.00 m 240 280 400 480 240 200 280 240 320 400 400 520 480 240 200 280 280 440 440 560 520 240 240 320 320 400 400 480 440 560 520 240 240 320 320 400 400 520 440 600 520 Dry screed Wet screed *) in addition to the rib elements own weight (the rib elements own weight is already taken into account in the table) 1 2

S T R U C T U R A L P R E - A N A LY S I S T A B L E S KLH 3s 108 DL 108 mm h BSH = acc. to table b BSH = 140 mm a = 600 mm Service class 2 k def = 0.8 Imposed load categories A and B (ψ 0 = 0.7 and ψ 2 = 0.3): k mod = 0.8 Imposed load category C (ψ 0 = 0.7 and ψ 2 = 0.6): k mod = 0.9 Deflection limits according to ÖNORM EN 1995-1-1:2009 a) characteristic structural design situation: w Q.inst l/400 and (w fin w G.inst ) l/250 b) quasi-permanent structural design situation: w fin l/300 Vibration test according to ÖNORM B 1995-1-1:2014 a) floor slab class I: slab between different utilisation units (e.g. separating floor slabs for apartments or offices); wet screed, floating on filler; dry screed, floating on heavy filler (at least 60 kg/m²) b) Limit value of the frequency and stiffness criterion: f 1.min 4.5 Hz; f 1 f gr = 8 Hz; w stat w gr = 0.25 mm c) Attenuation factor for cross-laminated timber floor slabs with floating screed and heavy floor structure: ζ = 4.0 % d) Limit value acceleration (required at f 1.min f 1 f gr ): a rms a gr = 0.05 m/s² Load-bearing capacity a) Test of bending stress b) Test of shear stress Structural fire design (one-sided burn-off on panel, 3-sided burn-off on rib) The fire analysis is currently not taken into account in the structural pre-analysis tables. According to our experience, the specified building components achieve a fire resistance of at least REI 30. Higher fire resistance classes require additional measures (increase of board or rib dimensions, panelling of essential building components). This table is only intended for structural pre-analysis purposes and does not replace necessary structural calculations! 1 3

S T R U C T U R A L P R E - A N A LY S I S T A B L E S 04 KLH RIB ELEMENT AS A ROOF SINGLE-SPAN GIRDER Deflection Appearance and avoidance of damage Minimum panel thicknesses for R 0 (cold dimensioning) µ s k g k according to ETA-06/0138:2017 ÖNORM EN 1995-1-1:2009 and ÖNORM B 1995-1-1:2014 ÖNORM EN 1995-1-2:2011 and ÖNORM B 1995-1-2:2011 l Constant load Snow load on roof REQUIRED RIB HEIGHT [mm] FOR A SPAN OF l g k *) s = µ*s k 8.00 m 9.00 m 10.00 m 11.00 m 12.00 m [kn/m²] 0.50 1.00 2.00 2.50 [kn/m²] 1.00 160 200 240 240 240 2.00 200 240 280 320 3.00 280 320 240 280 320 400 5.00 320 400 440 280 6.00 440 480 400 7.00 320 480 520 1.00 240 280 320 200 240 2.00 280 320 3.00 240 280 320 400 400 440 280 320 5.00 480 440 6.00 400 320 520 7.00 440 480 1.00 200 240 320 280 320 2.00 240 280 3.00 320 400 320 400 440 280 5.00 440 480 6.00 400 520 320 480 7.00 400 560 1.00 320 240 280 280 2.00 400 3.00 400 440 280 320 480 440 5.00 400 320 520 6.00 480 440 7.00 400 520 560 1.00 240 280 400 2.00 3.00 320 400 440 280 440 480 400 5.00 520 320 480 6.00 400 440 560 7.00 520 *) in addition to the rib elements own weight (the rib elements own weight is already taken into account in the table) 1 4

S T R U C T U R A L P R E - A N A LY S I S T A B L E S KLH 3s 95 DL 95 mm h BSH = acc. to table b BSH = 140 mm a = 600 mm Service class 2 k def = 0.8 Snow load at an altitude 1.000 m above sea level (ψ 0 = 0.5 und ψ 2 = 0): k mod = 0.9 Deflection limits according to ÖNORM EN 1995-1-1:2009 a) characteristic structural design situation: w Q.inst l/400 and (w fin w G.inst ) l/250 b) quasi-permanent structural design situation: w fin l/300 Load-bearing capacity a) Test of bending stress b) Test of shear stress Structural fire design (one-sided burn-off on panel, 3-sided burn-off on rib) The fire analysis is currently not taken into account in the structural pre-analysis tables. According to our experience, the specified building components achieve a fire resistance of at least REI 30. Higher fire resistance classes require additional measures (increase of board or rib dimensions, panelling of essential building components). This table is only intended for structural pre-analysis purposes and does not replace necessary structural calculations! 1 5

n o t e s

K L H M A S S I V H O L Z G M B H Gewerbestraße 4 8842 Teufenbach-Katsch Austria Tel +43 (0)3588 8835 0 Fax +43 (0)3588 8835 20 of fice@klh.at www.klh.at For love of nature Printed on ecologically friendly paper