Tower Cranes & Foundations The Interface & CIRIA C654 Stuart Marchand C.Eng. FICE FIStructE Director Wentworth House Partnership

Similar documents
Practical Design to Eurocode 2. The webinar will start at 12.30

Bending and Shear in Beams

EN Eurocode 7. Section 3 Geotechnical Data Section 6 Spread Foundations. Trevor L.L. Orr Trinity College Dublin Ireland.

DESIGN AND DETAILING OF COUNTERFORT RETAINING WALL

DESIGN OF STAIRCASE. Dr. Izni Syahrizal bin Ibrahim. Faculty of Civil Engineering Universiti Teknologi Malaysia

Associate Professor. Tel:

Clayey sand (SC)

RETAINING WALL ANALYSIS

Structural Calculations for Juliet balconies using BALCONY 2 System (Aerofoil) handrail. Our ref: JULB2NB Date of issue: March 2017

O Dr Andrew Bond (Geocentrix)

RETAINING WALL ANALYSIS

GEOTECHNICAL ENGINEERING ECG 503 LECTURE NOTE ANALYSIS AND DESIGN OF RETAINING STRUCTURES

RAMWALL DESIGN METHODOLOGY

Erratum. Chapter 4 - Earth and water pressure 26. Chapter Area loads. q a. c+d ϕ'/2. Piling Handbook, 9th edition (2016)

Detailing. Lecture 9 16 th November Reinforced Concrete Detailing to Eurocode 2

The Concepts of Eurocode 7 for Harmonised Geotechnical Design in Europe

Chapter (11) Pile Foundations

Analysis of the horizontal bearing capacity of a single pile

Safety Concepts and Calibration of Partial Factors in European and North American Codes of Practice

Verification of a Micropile Foundation

30/03/2011. Eurocode 7 Today and Tomorrow. Ground structures t Slope and Retaining wall design in the Netherlands. Contents

Design Example 2.2. Pad foundation with inclined eccentric load on boulder clay

Reinforced Soil Structures Reinforced Soil Walls. Prof K. Rajagopal Department of Civil Engineering IIT Madras, Chennai

INTI COLLEGE MALAYSIA

R.C. FOUNDATION ANALYSIS, DETAILS & DETAILING

Design of AAC wall panel according to EN 12602


Design of reinforced concrete sections according to EN and EN

Job No. Sheet No. Rev. CONSULTING Engineering Calculation Sheet

Engineeringmanuals. Part2

Bored piles in clay and Codes of Practice. Malcolm Bolton

CHAPTER 4. Design of R C Beams

Standardisation of UHPC in Germany

Assignment 1 - actions

Practical Design to Eurocode 2

APOLLO SALES LTD PUBLIC ACCESS SCAFFOLD STEP DESIGN CHECK CALCULATIONS

Seminar Worked examples on Bridge Design with Eurocodes

CRACK FORMATION AND CRACK PROPAGATION INTO THE COMPRESSION ZONE ON REINFORCED CONCRETE BEAM STRUCTURES

Pre-stressed concrete = Pre-compression concrete Pre-compression stresses is applied at the place when tensile stress occur Concrete weak in tension

The Bearing Capacity of Soils. Dr Omar Al Hattamleh

Jose Brito, Cenor, Portugal

Chapter (4) Ultimate Bearing Capacity of Shallow Foundations (Special Cases)

Analysis of a single pile settlement

Reinforced concrete structures II. 4.5 Column Design

Session 3. Calculation Models. EQU, UPL and HYD. Design of Pile Foundations

Verification Manual. of GEO5 Gravity Wall program. Written by: Ing. Veronika Vaněčková, Ph.D. Verze: 1.0-en Fine Ltd.

Example 2.2 [Ribbed slab design]

9.5 Compression Members

Introduction to The Design Example and EN Basis of Design

Delhi Noida Bhopal Hyderabad Jaipur Lucknow Indore Pune Bhubaneswar Kolkata Patna Web: Ph:

Concise Eurocode 2 25 February 2010

EUROCODE EN SEISMIC DESIGN OF BRIDGES

Eurocode 7 from soil mechanics to rock mechanics. Luís Lamas, LNEC, Lisbon, Portugal Didier Virely, CEREMA, Toulouse, France

Annex - R C Design Formulae and Data

Design of a Multi-Storied RC Building

3-BEARING CAPACITY OF SOILS

LIVING REINFORCED SOIL - AN ECOLOGICAL METHOD TO STABILISE SLOPES

UNIT II SHALLOW FOUNDATION

Civil Engineering Design (1) Analysis and Design of Slabs 2006/7

DESIGN OF STEEL GRILLAGE FOUNDATION FOR AN AUDITORIUM

INTRODUCTION TO STATIC ANALYSIS PDPI 2013

Appraisal of Soil Nailing Design

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

In-class Exercise. Problem: Select load factors for the Strength I and Service I Limit States for the. Loading Diagram for Student Exercise

Theory of Shear Strength

TABLE OF CONTENTS CHAPTER TITLE PAGE TITLE PAGE DECLARATION DEDIDATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

1 Spread footing: Pole_7 Number: 1

Design of a Balanced-Cantilever Bridge

Strengthening of columns with FRP

HKIE-GD Workshop on Foundation Engineering 7 May Shallow Foundations. Dr Limin Zhang Hong Kong University of Science and Technology

Objectives. In this section you will learn the following. Development of Bearing Capacity Theory. Terzaghi's Bearing Capacity Theory

Talić Z. et al: Geotechnical characteristics... Archives for Technical Sciences 2014, 11(1), 33-39

Civil Engineering Design (1) Design of Reinforced Concrete Columns 2006/7

3.2 Reinforced Concrete Slabs Slabs are divided into suspended slabs. Suspended slabs may be divided into two groups:

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

APOLLO SCAFFOLDING SERVICES LTD SPIGOT CONNECTION TO EUROCODES DESIGN CHECK CALCULATIONS

Seismic design of bridges

Project: Cantilever Steel SheetPile Retaining Wall Analysis & Design, Free Earth Support In accordance Eurocode 7.

Tipologia e dimensionamento estrutural das fundações de Torres de Linhas de Alta Tensão em diferentes condições geotécnicas

Bridge deck modelling and design process for bridges

Worked examples. Dr. Bernd Schuppener German Federal Waterways Engineering and Research Institute, Karlsruhe Past Chairman of CEN TC250/SC 7

10/14/2011. Types of Shear Failure. CASE 1: a v /d 6. a v. CASE 2: 2 a v /d 6. CASE 3: a v /d 2

Chapter (3) Ultimate Bearing Capacity of Shallow Foundations

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

BEARING CAPACITY SHALLOW AND DEEP FOUNDATIONS

Chapter 6 Bearing Capacity

Module 6. Shear, Bond, Anchorage, Development Length and Torsion. Version 2 CE IIT, Kharagpur

vulcanhammer.net This document downloaded from

Serviceability Limit States

Geotechnical Modeling Issues

NAGY GYÖRGY Tamás Assoc. Prof, PhD

Design Manual to BS8110

Example 4.1 [Uni-axial Column Design] Solution. Step 1- Material Step 2-Determine the normalized axial and bending moment value

Comparative Study of Strengths of Two-Way Rectangular Continuous Slabs with Two Openings Parallel to Long Side and Short Side

Harmonized European standards for construction in Egypt

CE5510 Advanced Structural Concrete Design - Design & Detailing of Openings in RC Flexural Members-

Theory of Shear Strength

BE Semester- I ( ) Question Bank (MECHANICS OF SOLIDS)

Module 7 (Lecture 25) RETAINING WALLS

Job No. Sheet No. Rev. CONSULTING Engineering Calculation Sheet. Member Design - Reinforced Concrete Beam BS8110 v Member Design - RC Beam XX

Transcription:

Tower Cranes & Foundations The Interface & CIRIA C654 Stuart Marchand C.Eng. FICE FIStructE Director Wentworth House Partnership

EXAMPLES OF TOWER CRANE FOUNDATION TYPES

Rail mounted

Pad Base

Piled Base

Piled Base

Grillage Base

Grillage Base

SELECTION OF FOUNDATION TYPE This will depend on: The class of crane Light, Medium or Heavy duty and The ground conditions Very soft clay to Rock and The site constraints open area or congested inner city

Mechanical The Interface Civil Thou (μm) EN 13001-02 Regular, Variable, & Occasional Loads 1/16 (mm) EN1990 Permanent, Quasi- Permanent, Variable, & Accidental Actions

Foundation designs are currently carried out in accordance with CIRIA C654 Tower Crane Stability This guide published in 2006 anticipated that the information from crane owners would in future be more detailed so as to align with Eurocodes

CIRIA C654 Tower Crane Stability is currently being re-written to align with Eurocodes This is proving challenging due to the misalignment of the product design code with the general Eurocodes, and the different information provided by different manufacturers.

Typical Foundation Loads In Operation Out of Operation Erection Storm from rear Storm from front M (knm) H (kn) V (kn) M (knm) H (kn) V (kn) M (knm) H (kn) V (kn) M (knm) H (kn) V (kn) 3343 65 939 2836 129 910 4270 87 912 3488 29 581

Draft revision to C654 treatment of the above loads The Self Weight of the tower crane and of the foundation is taken as a Permanent Action All other loads are taken as Variable Actions

Design of a simple pad base foundation There are 3 main aspects to the design a) Stability the EQU limit state b) Geotechnical Capacity the GEO limit states c) Structural Design STR limit state

Example Design Method Provisional Still Under Development Gravity Crane Base

In order to illustrate the above we will use loading data from the Liebherr 280 EC-H 12 Litronic at a hook height of 47.9m with a 75m jib Ground conditions will be taken as a cohesive material with shear strength of 200 kn/m 2

The EQU limit state Erection Case Wt of base = 6.5m x 6.5m x 1.4m x 24 kn/m 3 = 1420 kn Wt of crane = 581 kn Total = 2001 kn Stabilising Moment = 2001 kn x 6.5m / 2 x 0.9γ = 5852 knm Destabilising Moment =(3488 + 29 kn x 1.4 m)x1.5γ = 5292kNm Stabilising > Destabilising - OK

Storm Case Wt of base = 6.5m x 6.5m x 1.4m x 24 kn/m 3 = 1420 kn Wt of crane = 912 kn Total = 2132 kn Stabilising Moment = 2332 kn x 6.5m / 2 x 1.0γ = 7579 knm Destabilising Moment =(4270 + 87 kn x 1.4 m)x1.0γ = 4391kNm Stabilising > Destabilising - OK

The GEO limit states There are 2 Ultimate GEO limit states to check, one with a material factor of 1.0 on the soil properties, and the other with a capacity reduction factor in this case 1/1.4 on the soil strength. The maximum soil pressures occur with the jib at an angle to the base. Part of the base may not be in contact with the ground.

Contact area Note that the ground capacity varies with the loaded shape

The pressure is calculated based on Meyerhof for an equivalent uniform pressure distribution over a reduced rectangular area

GEO limit state ULS Combination 1 Bearing capacity there are 2 cases to check Factor the variable load (moment) by 1.5 Factor the permanent load (Base and Crane wt.) by Case 1 1.35 Case 2 1.0 Calculate the area of ground under load for a variety of jib angles for each case. Calculate the bearing pressure on the ground Calculate the bearing capacity of the ground for each pressure and loaded area Check that Capacity > Applied Load

GEO ULS Combination 1 Case 1 Erection Stabilising Action = 2001 kn x1.35γ = 2701 kn Destabilising Moment =(3488 + 29 kn x 1.4 m)x1.5γ = 5292kNm Eccentricity = 5292kNm / 2701kN = 1.95m Width of soil loaded = 6.5m 2 x 1.95m = 2.6m Soil Capacity = A' (c ud N c b c s c i c + q) Soil Capacity = 9718 kn 9718 kn > 2701 OK

GEO ULS Combination 1 Case 2 Erection Stabilising Action = 2001 kn x1.0γ = 2001 kn Destabilising Moment =(3488 + 29 kn x 1.4 m)x1.5γ = 5292kNm Eccentricity = 5292kNm / 2001kN = 2.64m Width of soil loaded = 6.5m 2 x 2.64m = 1.22m Soil Capacity = A' (c ud N c b c s c i c + q') Soil Capacity = 4350 kn 4350 kn > 2001 OK

Sliding The horizontal load is a variable load and hence factored by 1.5 The soil resistance is unfactored, but the friction factor between the concrete and soil needs to be incorporated. EC7 does not give any guidance, but BS8002 suggests 0.75 Horizontal Action= 29 x 1.5γ = 43.5 kn Resistance = 100 kn/m 2 x 1.22m x 6.5m * 1.0γ * 0.75 = 594 kn

GEO limit state ULS Combination 2 Bearing Capacity Factor the variable load (moment) by 1.3 Factor the permanent load (Base and Crane wt.) by 1.0 Calculate the area of ground under load for a variety of jib angles for each case. Calculate the bearing capacity of the ground for each pressure and loaded area Compare this with the failure capacity of the ground with strength reduced by 1.4

GEO ULS Combination 2 Erection Stabilising Action = 2001 kn x1.0γ = 2001 kn Destabilising Moment =(3488 + 29 kn x 1.4 m)x1.3γ = 4587kNm Eccentricity = 4587kNm / 2001kN = 2.29m Width of soil loaded = 6.5m 2 x 2.29m = 1.92m Soil Capacity = A' (c ud N c b c s c i c + q') Soil Capacity = 8221 kn 8221 kn > 2001kN OK

Sliding The horizontal load is a variable load and hence factored by 1.3 The soil resistance is factored by 1/1.4, and the friction factor between the concrete and soil is incorporated. Horizontal Action= 29 x 1.3γ = 37.7 kn Resistance = 100 kn/m 2 x 1.92m x 6.5m * 0.75 / 1.4γ = 668 kn

GEO limit state SLS Calculate the settlement of the ground under SLS loads and confirm this is acceptable with the Tower crane Manufacturer OR Based on UK custom and practice, calculate the bearing pressure on the ground under SLS loading, and if this is < 1/3 of the failure capacity, deem that settlements will be acceptable

STR limit state Design with jib orthogonal Take the worst case from the GEO analysis Calculate the maximum moment which is at the point of zero shear

GEO ULS Combination 1 Case 2 Design the reinforcement The base projects 2m beyond the tower crane leg (point of zero shear) Ground Pressure = 2001 kn / 1.22m / 6.5 m = 252 kpa Design moment = 252 kpa * 1.22m *(3.25 m 1.22m/2) 33.6kPa *(2.25m) 2 /2 = 520 knm/m

Using 25/30 concrete f ck = 25 N/mm 2 Effective depth = 1.4m 50mm cover 40mm bar allowance = 1310mm K = M ed / (bd 2 f ck ) = 520 x 10 6 / 1000/1310 2 / 25 = 0.012 Lever arm Z = d(0.5 + Sqrt(0.25 K / 0.9)) but < 0.95 x d Z = 0.95 x 1310 = 1245mm Area of reinforcement required A s = M / f yd z = 520 knm / (500/1.15γ x1245mm) = 960 mm 2 /m

Check minimum reinforcement = 0.26 x (f ctm /f yk )b t d >0.0013b t d where f ctm = 0.30f ck 0.666 = 0.30 x 25 0.666 = 2.56 Mpa Minimum reinforcement = 0.26 x (2.56/500) x 1000 x 1310 0.0013 x 1000 x 1310 1744 mm 2 / m but > 1703 mm 2 / m Hence minimum reinforcement governs 1744 > 960 mm 2 / m

Check Shear Design Shear at d from support 252 kpa * 0.94m - 33.6kPa *0.94m = 205 kn/m Shear stress v Ed = 205 kn/m / 1310mm / 1m = 0.16 kpa v Rd,c = (0.18/γ c )k(100r l f ck ) 0.333 0.035k 1.5 f 0.5 ck where γ c = 1.5 k = 1 + (200/d) 0.5 2.0: k = 1 + (200/1310) 0.5 = 1.39 r l = A sl /bd = 1744/(1000x 1310) = 0.00133 f ck = 25 MPa v Rd,c = (0.18/1.5)x 1.39 x (100 x 0.00133 x 25) 0.333 0.035 x 1.38 1.5 x 25 0.5 = 0.284> 0.249 0.16 MPa

Pull out/push through of the anchors The CIRIA guide states If the manufacturer s recommendations regarding shear reinforcement are followed, punching and pull out shear should be satisfactory I have yet to see any manufacturer s recommendations regarding shear reinforcement, apart from sketches indicating where it should go.

Foundation Anchors

This is fundamentally a punching shear issue With some types of anchor it is clear where the failure cone will occur

With others it is less clear, but Liebherr now suggest

Discussion Points Storm from front condition should this be a general design case or a special case? Why can we not have loadings which are Eurocode compliant? What load factors are appropriate to the erection case? Are current expendable anchor designs sustainable and what can be done to improve them?