THE MEASUREMENT OF COLOR IN A QUALITY CONTROL SYSTEM: TEXTILE COLOR MATCHING

Similar documents
Introduction to Colorimetry

Visual Imaging and the Electronic Age Color Science Metamers & Chromaticity Diagrams. Lecture #6 September 7, 2017 Prof. Donald P.

Vision & Perception. Simple model: simple reflectance/illumination model. image: x(n 1,n 2 )=i(n 1,n 2 )r(n 1,n 2 ) 0 < r(n 1,n 2 ) < 1

The PUMA method applied to the measures carried out by using a PC-based measurement instrument. Ciro Spataro

Integrating Sphere Spectroradiometer System for LED LPCE-2(LMS-8000A) Brochure. Global Office of Lisun Electronics Inc.

SOME ASPECTS OF PYROMETRY OF "WHITE" OBJECTS V.E.

Uncertainty determination of correlated color temperature for high intensity discharge lamps

Measurement method for the proficiency testing program

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

Thermal Resistance & Spectroradio meter System for LED (TRS-1000) Brochure. Global Office of Lisun Electronics Inc.

Precision and Bias of Spectrocolorimeters

Color perception SINA 08/09

Uncertainty determination of correlated color temperature for high intensity discharge lamps.

The Truth about Neutrality

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

STATISTICAL PROCESS CONTROL - THE IMPORTANCE OF USING CALIBRATED MEASUREMENT EQUIPMENT. CASE STUDY

THERMOFOCUS, a technological innovation

PRACTICAL UNCERTAINTY BUDGETS FOR SPECTRAL MEASUREMENTS OF LEDS

Report No.: EASZF Page 2 of 14

Non-Destructive Inspection of Brazed Joint by Pulsed Phase Thermography

TL6 Ultra Micro-volume Spectrophotometer

Improvement Uncertainty of Total luminous Flux Measurements by Determining Some Correction Factors

TEST REPORT IEC Photobiological safety of lamps and lamp systems

Standard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates 1

Transmission matrices of random media: Means for spectral polarimetric measurements

Experimental confirmation of the negentropic character of the diffraction polarization of diffuse radiation

Test Report. Project No: Report No: aR01 Report Issued Date: Customer Company & Address:

COLOR SCIENCE. Concepts and Methods, Quantitative Data and Formulae, 2nd Edition. John Wiley & Sons New York Chichester Brisbane Toronto Singapore

Compton Camera with PositionSensitive Silicon Detectors

Smart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017

Imagent for fnirs and EROS measurements

White Paper Luminance & Illuminance. Brief explanation of photometry for the application of tunnel lighting control

INFRAMET. 2.1 Basic laws

DAY LABORATORY EXERCISE: SPECTROSCOPY

Experiment 4 Radiation in the Visible Spectrum

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Chapter 1. Blackbody Radiation. Theory

LIBSlab ANALYZERS ANALYZERS

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

( J s)( m/s)

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Signal to Noise Comparison of IS-Instruments Ltd High Throughput OEM Spectrometer and a Czerny Turner Instrument. July 2013

Miniature Fiber Optic Spectrometry StellarNet Tutorial

Compliance with the National requirements of EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES for EN 62471:2008.

AS 101: Day Lab #2 Summer Spectroscopy

THERMAL RADIATION. The electromagnetic radiation emitted by a hot tungsten filament will be studied.

BETTER DESIGN AND NEW TECHNOLOGIES IMPROVE LASER POWER MEASUREMENT INSTRUMENTATION

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

/qirt The influence of air humidity on effectiveness of heat sink work. by M. Kopeć*, R. Olbrycht*

TEST REPORT EN 62471:2008 Photobiological safety of lamps and lamp systems

Designing Information Devices and Systems II A. Sahai, J. Roychowdhury, K. Pister Discussion 1A

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

History & Scope of Remote Sensing FOUNDATIONS

PROCESS CONTROL BASIS FOR A COST-EFFECTIVE SELECTIVE SOLDERING PROCESS

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

Photobiological safety of lamps and lamp systems

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Thermal Resistance Measurement

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Spectroscopy - is the study of the interaction between matter and radiated energy.

EVERLIGHT ELECTRONICS CO., LTD.

Visual Imaging and the Electronic Age Color Science

Measuring Laser Diode Optical Power with an Integrating Sphere

PRELIMINARY SPECIFICATIONS

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC LVD TEST REPORT

Color vision and colorimetry

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

Fundametals of Rendering - Radiometry / Photometry

A COMPARISON BETWEEN DGI OBTAINED THROUGH DIFFERENT METHODS AND PERCEIVED EVALUATION INDEX DDG

LATE REQUEST FOR A SPECIAL PROJECT

Numerical and experimental analysis on Double Light Pipe, a new system for daylight distribution in interior spaces.

Optical Measurement Guidelines for High-Power LEDs and Solid State Lighting Products

Photometric Test Report

Illumination, Radiometry, and a (Very Brief) Introduction to the Physics of Remote Sensing!

Tennis player segmentation for semantic behavior analysis

IES LM MEASUREMENT AND TEST REPORT For

A Straight Forward Path (Roadmap) to EUV High Brightness LPP Source

Local Criterion of Quality for Color Difference Formula

Screen-space processing Further Graphics

QUALITY ASSURANCE WITH SPECTROMETER HARDWARE APPS FOR MOBILE SMART PHOTONIC SPECTRAL MEASUREMENTS

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Phys 322 Lecture 34. Chapter 13. Modern optics. Note: 10 points will be given for attendance today and for the rest of the semester.

Practical 1P4 Energy Levels and Band Gaps

CBM-360 LEDs. CBM-360 Product Datasheet. Features: Table of Contents. Applications

Practical 1P4 Energy Levels and Band Gaps

AN3002 Thermocouple measurement

Old painting digital color restoration

Spectroscopy of Various Light Sources: The Interactions between Light and Matter ASTR 170B1, Spring 2017, Lab #2. 1 Introduction.

Digital Image Processing

INC 331 Industrial Process Measurement. Instrument Characteristics

CS681 Computational Colorimetry

Technical Data Sheet Top View LEDs

UNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT

Advanced Laser Surface Analyzer. Francis V. Krantz Ashland Inc Blazer Parkway Dublin, Ohio Abstract

MEASUREMENT ERRORS Introduction

Modeling of Atmospheric Effects on InSAR Measurements With the Method of Stochastic Simulation

Transcription:

th IMEKO TC7 International Symposium June 3 July 2, 24, Saint-Petersburg, Russia THE MEASUREMENT OF COLOR IN A QUALITY CONTROL SYSTEM: TEXTILE COLOR MATCHING Andrea Zanobini, Gaetano Iuculano Department of Electronic and Telecommunication, University of Florence Via Santa Marta, 3 539, Florence, Italy Abstract - In this paper we propose a criterion for uncertainty evaluation in a color quality control. In a joint project between two laboratories of the Faculty of Engineering in Florence we study a PC-CCD system, called Textile Color Match (TCM) for the digital acquisition of the colorimetric coordinates of a wool sample. One of the main result is the achievement of a threshold of tolerance for the reproduction of this colored sample. Keywords: Color quality control, Colorimetric coordinates, Chromatic tolerance. INTRODUCTION It s important to take into consideration all the objective parameters linked to the quality control of a product, expecially those that interfere with human sensations like color perception, smell, taste. In particular the task to find reliable chromatic tolerance in industrial production of tinted wool implies different problems of quality control and, in general, this task is not related to the physical size of the product like its dimension, weight or strenght that are measured during the production cycle. This study interacts with the visual human sensation and with the eye capacity of chromatic discrimination. Usually, the color quality control of a product is made by direct observation: we compare the test color of this product with the sample item, or with a color set (i.e. Pantone [] in textile industry). In advanced production a spectrophotometer is also used to estimate the surface reflectance; in this way it is possible to calculate the colorimetric distance between a sample and the reference. In this paper we propose a criterion for the uncertainty evaluation in a color quality control process It is important to underline that the color perception is linked to the neuro-physiology of our brain. This means that our feelings and our behaviour are anyway related to this color perception. In fact, not only physicians and painters approached this fascinating topic but also poets, philosophers and psychologists. Neuro-science demonstrated recently a direct connection between psychological and physiological stimula: our feelings and emotions are a fascinating theatre in which the color has a primary role. George Simmel [2], a german philosopher and sociologist, put in evidence our habit to consider the prices of the products like an intrinsic property of them and not related to the effect of dynamics between supply and demand. This happens also in the color evaluation, that in opposition to the common perception it is not an intrinsic characteristic of the objects, not a phisical quantity, but a quality, an attribute of the visual feeling and so subjective and inexpressible. This seems to deny every measure of color; but if we consider that different people may agree on color evaluation, we understand that this is not completely true. Moreover the procedures of standardization are not so well defined and, on the other side, the instruments and the techniques for the color meausurament often are not economically suitable to this aim. 2. TEXTILE COLOR MATCHING (TCM) SYSTEM In order to define the criterion to evaluate the color control quality, we have designed a system consisting of a personal computer (Intel Pentium III 7 MHz processor) and a linear scanning system with a professional scanner with optical resolution, dynamic range, scan speed, showed with other important characteristics, in Table I. 497

TABLE I. Characteristics of TCM system Optical resolution Dynamic range * 2 dpi 3.7 D Scan speed ms B/N Scan area A/D Converter Illumination system ms color 6 cm² 4 bit cold cathode lamp The brain of this system includes a software purposely implemented in Visual C++, that supplies the colorimetric distance based on the CIELab coordinates [3] between a sample and the reference standard and all the eventual corrections given to the operator. The selection of the acquisition area is automatically carried on: the operator must only place the reference standard and the test sample on two windows (4 x 4 cm) realized on an appropriate mask of black color equipped with the colorimetric standard scale IT8 7/2 for the system calibration, as we can see in Figure no. coordinates (X n, Y n, Z n ) of the illuminant are related to a perfect reflecting surface. For the assessment of these coordinates we consider the reproduced white standard of IT8 thin cardboard like a perfect reflecting surface, and we calculate the CIELab coordinates measuring this area. In the next step we introduce the reference code of the product and then we save these three images in order to realize a quality control archive. Moreover we also saves the coordinates RGB, XYZ and CIELab of each image, with the values of the colorimetric distances calculated with CIELab, CMC(l:c), CIE94 formulae. [4], [5]. In order to better understand the following result it is useful to put in evidence the techniques adopted to acquire the images with TCM system. In fact, the three fundamental colors, Red, Green and Blue correspond to the three types of CCD sensors, in particular white color corresponds to the following coordinates: red = R = 65535, green = G = 65535 and blue = B = 65535. TCM Software management system offers many possibilities to elaborate the acquired images; one of the most important is the automatic color balance that computes the nearest white point to the theoretical white, calculating the differences between RGB coordinates and those of the theoretical white. In some situations this balance operation changes the colors, rendering the obtained images less reliable and usable for the purposes of this study. However we do not perform any kind of elaboration, assuming all the chromatic information. On the other hand this fact does not exlude however that in the progress of this resarch we can elaborate the acquired images to facilitate the colorimetric comparison in some kind of samples, like those melange or those particularly colored. Finally it is important to emphasize that the reproduction time of this TCM system is maintained less or equal to the two, and this is an important characteristic with respect to the economy of the production. 3. TEMPORAL UNCERTAINTY OF TCM SYSTEM Figure. Chromatic mask for TCM system calibration Three selections allow the user to acquire RGB coordinates with resolution equal to 6 bpp (bit per pixel) of the white standard point, of the reference standard and of the test sample. White standard acquisition is very important because the CIELab In order to characterize the stability of this system, we carried out a temporal analysis by acquiring the white standard point every 2 for the first from the start up of the device. We have chosen to center this analysis on the white standard point because its acquisition is done every time the system is used. The measurement of the white standard point accounts for the radiaton emitted by the system lamp: since this radiation is completely reflected, this point is detected by the CCD sensor. On the other side, studying the answer of the acquisitions of a whichever colored sample, would have been differently stimulated 498

the three channels of CCD sensors and every comparison between them would be inadequate. Therefore we have considered the first 25 acquisitions of the white standard point, in the same operating conditions, on the three channels R, G and B, every two from the start up of the device and we calculate the average values on three repetitions. Working with 6 bpp the values of the colorimetric coordinates belong to the range (:65535), hence the theoretical white standard point that reflects all the radiance emitted from the lamp, excites the three channels of CCD sensor in the same way (if the spectral power density of the radiant is constant) and we would have values R = G = B = 65535. In the practical case with the spectral power density variable in frequency, the reflected radiance will not be theoretically white, and so the quantic efficiency of the channels will not be the same because the number of absorbed and incident photons would be different. These last considerations put in evidence that the temporal characterization of the channels excitation levels reflect this stochastic behaviour; therefore the value 65535 will be only a useful theoretical reference for the comparison between them. 3.. Temporal characterization of R coordinate In Figure no.2, we can see the time series of the average on three repetitions of the first 25 acquisitions of the R channel, every two from the start up interpolated with a continuous line. The R coordinate varies from 64773.54 to 64956.2 with an average value equal to 67.58 and with a range equal to 82.66, representing the,28% of the average value. From the variance, equal to 2628.42 we compute type A standard uncertainty equal to 5.26. R value 6495 649 65 6 6475 647 6465 Temporal course of R channel 6 8 3 Figure 2. Drift of the R channel, in the first of operation 3.2. Temporal drift of G coordinate In Figure no.3, we can see the time series of the average on three repetitions of the first 25 acquisitions of the G channel, every two from the start up 42 interpolated with a continuous line. The G coordinate varies from 6534.88 to 65233.49 with an average value equal to 6594.86 and with a range equal to 98.6, representing the,5% of the average value. From the variance, equal to 68.7 we compute type A standard uncertainty equal to.87. G value 6525 652 655 65 655 Temporal course of G channel 6 8 3 Figure 3. Drift of the G channel, in the first of operation 3.3. Temporal drift of B coordinate In Figure no.4, we can see the time series of the average on three repetitions of the first 25 acquisitions of the B channel, every two from the start up interpolated with a continuous line. The B coordinate varies from 64989.7 to 6594.5 with an average value equal to 654. and with a range equal to 98.6, representing the,3% of the average value. From the variance, equal to 249.37 we compute type A standard uncertainty equal to 46.. B value 653 652 65 649 6 Temporal course of B channel 6 8 3 Figure 4. Drift of the B channel, in the first of operation 3.4. Comparison between the temporal drifts of the three channels In Figure no.5 we can see the time series of the average of the data showed in the previously three figures (the R, G, B channels) and represented with dotted, continuous and dashed line respectively. Also in this case the acquisition is done every two from the start up for a total of. We also compute the correlation coefficient between the R-G 42 42 499

channels equal to.76, while the same computation between R-B and G-B channels gives us the result of.85 in both cases. R,G,B value Comparison between the temporal drifts of the three channels 654 652 6 646 644 4 8 6 2 28 Figure 5. Comparison between the temporal drifts of the three channels R, G and B, in the first In Table II we can see the variability of the TCM system on the three channel where we approach the theoretical case in which the standard white point would be equal to 65535. In this case, the time series of the average of the values belonging to R remains under the level of. The maximum difference with respect to the average value remains under.5% so that in the first the system remains in a steady state. This is particularly obvious for the G channel, whose variance is approximatively the half than in the other two channels. 32 4 44 TABLE II. Variability of the temporal answer of TCM system on the three channels Coord. R G B Average 67.58 6594.86 654. Variance %.28%.5%.3% Uncertainty %.7%.4%.7% statistic variability during the acquisition of the white standard point, considering 25 reading operations executed during three consecutive days. The time interval between two acquisitions is so variable and connected to the production and quality control. We also think that this spreading of data is related to the normal running of this system. 4.. R channel uncertainty In Figure no.6 we show the values belonging to the red channel in 25 asynchronous acquisitions of the white standard point interpolated with continuous line. The R coordinate varies from 6354.62 to 65279.28 with an average value equal to 64798.4 and with a range equal to 738.66, representing the 2.6% of the average value. From the variance, equal to 2232.89, we compute type A standard uncertainty equal to 469.. R value 655 645 64 635 63 625 23 R channel stability 45 67 89 33 55 77 99 22 3 Figure 6. R coordinate values in 25 acquisitions of the white standard point If we observe the behaviour of the system in the first, we can see that the range of the R coordinate together with the uncertainty value, increases of approximatively 9 times while the average remains approximatively constant (-,%). 4.2. G channel uncertainty The G coordinate varies from 6494.9 to 65276.9 with an average value equal to 6549.92 and with a range equal to 8.9, representing the.6% of the average value. From the variance, equal to 82.79 we compute type A standard uncertainty equal to 287.9 (Figure no.7). 4. ANALYSIS OF THE UNCERTAINTY OF TCM SYSTEM To certify the repeatability and stability characteristics of the system, we have studied the 5

G value 655 645 64 G channel stability respectively. We also compute the correlation coefficents between the R-G, R-B, G-B channels and we found them equal to.76,.73 and.82 respectively. In conclusion we can say that the correlation cofficients between the same three channels are approximatively of the same order and that there is not any appreciable difference between the starting behaviour of the system and its statistical average. 635 23 45 67 89 33 55 77 99 22 3 Figure 7. G coordinate values in 25 acquisitions of the white standard point. If we observe the behaviour of the system in the first, we can see that the range of the R coordinate together with the uncertainty value increases of approximately times while the average remains approximatively constant (-,2%). 4.3. B channel uncertainty The B coordinate varies from 6378.77 to 65273.93 with an average value equal to 6573.33 and with a range equal to 493.2, representing the 2.2% of the average value. From the variance, equal to 57444.99 we compute type A standard uncertainty equal to 239.67 (Figure no.8). B valore 655 645 64 635 63 B channel stability 47 7 93 6 39 62 85 28 23 R,G,B value 25 acquisitions White: channels R, G and B 655 645 64 635 63 625 22 43 64 85 6 7 69 9 2 Figure 9. Comparison between uncertainty of the three channels: R, G and B. In Table III we can see the comparison between the variability of the system in the first and in 25 asynchronous acquisitions of the white standard point. These data approached the theoretical case in which the white standard point would have coordinates equal to 65535. In spite of this fact the R coordinate is maintained under the level of but however, in all the three cases, the average is near to this value. 232 Figure 8. B coordinate values in 25 acquisitions of the white standard point If we observe the behaviour of the system in the first, we can see that the range of the R coordinate together with the uncertainty value increases of approximatively 7 times while the average remains approximatively constant (-, %). 4.4. Comparison between the three channels In Figure no.9 we can see the time series of the 25 acquisitions of white standard point showed in the previously three figures (the R, G, B channels) and represented with dotted, continuous and dashed line 5

TABLE III. Comparison between the variability of system TCM in the first and in 25 asynchronous acquisitions of the white standard point. 25 acquisitions Coordinate R G B Average 64798.4 6549.92 6573.33 Variance % 2.6%.6% 2.2% Uncertainty %.72%.44%.% First min. Coordinate R G B Average 67.58 6594.86 654. Variance %.28%.5%.3% Uncertainty %.7%.4%.7% We can therefore assert that this system demonstrates good stability on the three channels. There is not any appreciable difference between the starting behaviour of the system and its statistical average that maintains its value less than %: this is a typical value in chromatic acquisition systems using cameras or spectrophotometer. 5. CONCLUSION The observation and the study of the methods which the operators traditionally adopt to keep the system under control, put in evidence the need to investigate from the theoretical point of view what it is commonly called color. This word, always present in every moment of our life, is today still wrapped in the fog of common sense. All the theoretical recognition brought back this study to the search of an optimal chromatic tolerance. We move our resarch from the subjective level of the chromatic feelings to the level of the colorimetric science. We have been studied all those reproductions that exceed the factory traditional control, acquiring the colorimetric coordintaes through a PC-CCD system called TCM. This system was purposely implemented and tested in a joint research project between the Electronic and Telecommunication Department and the Energetic Department of the Faculty of Engineering in Florence, Italy. The main results obtained in this study concerns the analytical evaluation of the operators in quality control also in relation to the definition of chromatic tolerance classes. We also study the stability of TCM system for the digital acquisition of the colorimetric coordinates of the sample to achieve the definition of a threshold of chromatic tolerance, for reproducing a wool sample of a given color. We also supply the company with an analytical criterion on which setting up the chromaticity verification of the realized sample. It has been possible to reduce the customer claims from 4% to 6%. The future development of this research implies the verification of the goodness of the proposed method through a wide sample diversification, expecially for chromatic characteristics. Moreover some techniques that allow to take into account the various chromatic yields of several natural fibers or crafts ( melangé, puntinato ) are necessary to better evaluate the colorimetric distance in function of these kinds of samples. With TCM system is also possible, in spite of the spectrophotometer instrument usually used in the company, to analyze the variation of the colorimetric coordinates between the reference and sample test, in function of the image single pixel. REFERENCES [] Pantone Color Formula Guide, Pantone, Inc., 59 Commerce Boulevard, Carlstadt, N.J. [2] Simmel G Philosophy of value, American Journal of Sociology, vol. 5, 9. [3] CIE Publication n.6, Industrial color-difference evaluation, CIE, Wien, vol. 5, 995. [4] CIE Publication n. 5.2, Colorimetry, CIE, Wien, vol. 5, 986. [5] CIE Publication n., Parametric effects in colordifference evaluation, CIE, Wien, vol. 5, 993. Author: Ing. Andrea Zanobini, Department of Electronic and Telecommunication, University of Florence, Via Santa Marta, 3 539, Florence, Italy. Tel: +39554796392, Fax: +3955494569 Email: willis@ingfi.ing.unifi.it 52