Connections Standard. Description

Similar documents
Section 8 Column radiators

Hudevad P100. Technical datasheet

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)

Ascotherm eco KC281 Heating and cooling in 2-conductor system

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Dimensions. Order code. Materials and finish. lindab ceiling diffusers

MR medium rating busbar

Air distribution systems. Adjustable induction outlet IN-V...

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

Krantz. RL-C2 radial slot outlet. Air distribution systems

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

Nozzle diffuser. Dimensions

MYSON COLUMN RADIATORS. MYSON TECHNICAL GUIDE heatingthroughinnovation.

Plain diffuser. Dimensions

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

INTRODUCING HORIZONTAL

Air distribution systems. Linear whirl outlet WL...

Grille. Min. - max. dimensions

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air

VD1 CLC. Small Valves DIN-range with a higher k v -value

Swirl diffusers, Variable swirl diffusers

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air

Air distribution systems. Radial outlet RA-N2...

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

Plain diffuser. Dimensions

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

Cabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors

Cabinets NOVASTAR. Overview Cabinets Wall mounted cases Accessories for cabinets and wall mounted cases 3.

Displacement Flow Diffusers

Surface-mounting Thermostats ATH Type Series

Surface-mounting thermostats Series ATH

GTH. Rectangular double deflection grille QUICK FACTS

12.1 Product data sheet

CIRCO. Sound-attenuating transfer unit QUICK FACTS

2D - STRIP ANCHOR LIFTING SYSTEM

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Introduction...COMB-2 Design Considerations and Examples...COMB-3

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

PRO-CLEAN STRATIFIED TANK

12.1 Schlüter -KERDI-BOARD

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Variable swirl diffusers

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Conductivity sensor for hygienic applications

12.1 Product data sheet

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

PHOS 15 LED PROJECTOR

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Nozzle diffuser. Dimensions

KONTEC KS 20 KS 21 KS 10 KS 11 KS 10 KS 11 KS 21 KS 20. model overview / connection dimensions. KS models vertical design

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Linear ceiling diffuser

Air distribution systems. Adjustable radial outlet RA-V...

FORMWORK SAVINGS ADAPTABILITY LIGHT WEIGHT ECONOMICAL ALUMINIUM SLAB FORMWORK. BV Cert

Linear diffuser. Description

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Chapter 11: Heat Exchangers. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

laminated on both sides for effective anchoring in the tile adhesive.

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

Step Impulse Diffuser Model SIA

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

Multi-cone diffuser. Dimensions

Use. Worth noting. Key figures. Installation. lindab fasadium

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

ED 701 General Industry Pressure Transmitter

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

FRB. Exposed passive chilled beam for suspended installation

Valve Supply and exhaust air

Main Catalogue. Edition 23, chapter minirack: Phase-out product!

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

UvA-DARE (Digital Academic Repository) Converting lignin to aromatics: step by step Strassberger, Z.I. Link to publication

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

8.6 Product data sheet

CNA-CNB. Centrifugal fans

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

series FLOOR

Circular duct grille

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER: NEW MILLENNIUM BUILDING SYSTEMS, LLC

DBQ Painted four four-way square square diffuseurs M A D E L

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

TOWEL RAILS. Serie Comfort PRICE LIST

Mechanical flow-rate controllers

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series

Solar Flat Plate Thermal Collector

THREE HOLE SPLICE CLEVIS FOR B52 Standard finishes: ZN, GRN Wt./C 126 Lbs. (57.1 kg)

Nylon oil filler and air breather filler caps

Transcription:

Section Convectors Description Connections Standard without built-in valve or version with built-in valve Air vent, Drain Fixing Pressure versions, Fittings, Surface finishes, Special versions Heat output Technical data Lengths: 0 000 mm Heights: 0 0 mm Depths: mm Convector WVO With shield for radiated heat on rear Lengths: 0 000 mm Heights: 0 0 mm Depths: mm Universal convector LCR Ideal for stocking Lengths: 0 000 mm Heights: 0 0 mm Depths: mm - - - - - - - - - - - - - - - - - -0-0 -0 - - 0 Subject to technical change without notice. Technical Documentation 0-N -

Description Model C...... C....../ Standard without built-in valve Explanation model code C : convector C : convector... : height in cm... : height in cm... : number of tubes carrying water... : number of tubes carrying water / : with fins at rear Example C/ C : convector : height cm : tubes carrying water / : with fins at rear Model C......V C....../V Version with built-in valve V: with built-in valve 0 General Form and function combine in modern architecture in a harmonious manner. Arbonia convectors support the architect and client in this harmony: the clear emphasis of the horizontal line, clean side connections and the fine structure of the cover permit open installation. High heat output from small dimensions and the diverse range round off the attractive image of this room heater. Convectors C without fins at the rear are GUV-compliant in the special version with top grill. Range available depths: - Without fins at rear:,, and mm - With fins at rear:,, and mm heights: 0, 0, 0 and 0 mm Length: - 0 00 mm: steps: 00 mm - 00 000 mm: steps: 0 mm (manufacturing tolerance: ± mm, measured at C) - Maximum length 000 000 mm, as a function of weight empty -tube connections Rear lugs for depth mm ) Not in all colours Special versions -tube connections Version with built-in valve Built-in air vent with rotating outlet High-pressure version 0 bar (000 kpa) Top grill (GUV-compliant) Screwed feet Angled or curved version Rear lugs for depth mm Fixing as bench: - For convectors with depth mm - Order brackets as accessories Surface finishes AllFinish in pure white (AF) RAL 00 standard version AllFinish in traffic white (AF) RAL 0 Primed in cream-white (ET) Primed in cream-white and packed in plastic sheet (EF) ColorFinish in standard colour (CF) SuperFinish in colour of choice (SF) ) Textured paint after priming - In white (SL) - In colour of choice (KL) ) Clear lacquer (TF) Hot-dip galvanised outside, for wet rooms (swimming pools, cellar rooms for washing etc.), does not apply for damp rooms (bathroom and WC) - Without paint finish (ZN) - With textured paint in white (ZL) - With textured paint in colour of choice (ZK) ) Anti-microbial coating (AM) All finishes are baked at 0 C. For detailed information see "Colour Fashion of the Arbonia Radiators". - Technical Documentation 0-N Subject to technical change without notice.

Description Operating conditions For closed water heating systems in accordance with DIN 0 and water quality in accordance with VDI Can be used in conventional and low temperature areas Can be used for district heating and high-rise buildings (high permissible operating pressure) Not suitable for steam-based heating systems Length expansion: 0, mm/m at a temperature difference of K Properties of relevance to operation Minimum water flow rate The minimum water flow rate must not be less than 0 % of the standard water flow rate in accordance with EN to avoid a reduction in the heat output. This applies both to connection on same end and on opposite ends. Pressure drop Δp Δp = ζ x ρ/ x w Standardversion High-pressure version Operating pressure [bar (kpa)],0 (00) 0,0 (000) Test pressure [bar (kpa)], (0),0 (00) Max. temperature [ C] Δp: Pressure drop [Pa] ζ: Resistance coefficient Zeta [] ρ: Density of the water [kg/m ] w: Water velocity [m/s] The ζ values are given in the connection table and apply for a water velocity of up to m/s. Heat outputs The heat outputs given are determined and registered in accordance with the guidelines in EN : DIN CERTCO registered. RAL tested and registered. Tender text Room heaters with up to five 0 x x, mm steel tubes arranged one behind the other and up to four 0 x x, mm steel tubes arranged one above the other with convector fins and collectors on the ends connected by hidden welds and rounded edges all round with R min = mm. Ready to install with to connection threads on the ends in the collectors for flow and return as well as air vent and drain. Version with permanently fitted top grill (at extra charge) complies with the basic principles for the testing of the health and safety of room heaters (statutory accident insurance). Winner of award from the Institut für Umwelt- und Krankenhaushygiene at Philipps-Universität Marburg for compliance with high hygiene requirements. Priming in accordance with DIN 00 part and powder coating in accordance with DIN 00 part. Pressure and leak tested. Heat output tested and measured in accordance with EN. CE marked. Suitable for closed water heating systems in accordance with DIN 0 and water quality in accordance with VDI. Maximum permissible operating temperature C Max. operating pressure: bar / 00 kpa 0 bar / 000 kpa Suitably packed for transport. 0 Subject to technical change without notice. Technical Documentation 0-N -

Connections standard without built-in valve Connection options flow / return Connection system Ord. code ζ value Arrangement Ordering code Connec. size Ordering code Flow Return Dimension drawings -tube, side,0,0 G / G / G / See page Connection dimensions -tube, side -tube, side and bottom,0,0 G / G / G / See page Connection dimensions -tube, side and "Connections dimensions -tube, bottom" -tube, bottom,0,0 -tube, bottom,one behind the other,0,0 G / G / G / G / G / G / -tube, bottom, middle-middle,,0,0 G / vertical underside ) -tube, for valve with dip tube, side, with dip tube Ø mm 0,0,0 G / See page Connection dimensions -tube, bottom See page Connection dimensions -tube, bottom, one behind the other Only possible from C.. See page Connection dimensions -tube, middle See page Connection dimensions -tube -tube, for valve with dip tube, bottom, with dip tube Ø mm 0,0,0 G / See page Connection dimensions -tube -tube, for TKM valve, bottom, with dip tube,0,0 G / See page Connection dimensions -tube 0 ) Maximum length: 00 mm L: recommended position for air vent tapping: Standard baffle; baffle with Ø mm hole; valve with dip tube; TKM valve On models C0, C0/ the connections in arrangement and are only possible in G /. - Technical Documentation 0-N Subject to technical change without notice.

Connections standard without built-in valve Connection dimensions -tube, side Height 0 mm ) C...... C....../ C0/ ) Connection details 0 0 C0 ) C0/ ) 0 0 C0 C0/ 0 0 /" - /" C0 C0/ 0 0 C0 0 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions ) Only G / (for arrangement feature : or ) Subject to technical change without notice. Technical Documentation 0-N -

Connections standard without built-in valve Connection dimensions -tube, side Height 0 mm ) C...... C....../ C/ Connection details 0 0 C C/ 0 0 C C/ 0 0 /" - /" C C/ 0 0 0 C 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions - Technical Documentation 0-N Subject to technical change without notice.

Connections standard without built-in valve Connection dimensions -tube, side Height 0 mm ) C...... C....../ C/ Connection details 0 0 C C/ 0 0 C C/ 0 0 /" - /" C C/ 0 0 C 0 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions Subject to technical change without notice. Technical Documentation 0-N -

Connections standard without built-in valve Connection dimensions -tube, side Height 0 mm ) C...... C....../ C/ Connection details 0 0 C C/ 0 0 C C/ 0 0 /" - /" C C/ 0 0 0 C 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions - Technical Documentation 0-N Subject to technical change without notice.

Connections standard without built-in valve Connections dimensions -tube, bottom Height 0 mm ) C...... C....../ C0/ Connection details 0 C0 C0/ 0 0 C0 C0/ /" - /" 0 0 C0 C0/ /" 0 0 C0 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions 0 Subject to technical change without notice. Technical Documentation 0-N -

Connections standard without built-in valve Connections dimensions -tube, bottom Height 0 mm ) C...... C....../ C/ Connection details 0 C C/ 0 0 C C/ /" - /" 0 0 C C/ /" 0 0 0 C 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions -0 Technical Documentation 0-N Subject to technical change without notice.

Connections standard without built-in valve Connections dimensions -tube, bottom Height 0 mm ) C...... C....../ C/ Connection details 0 C C/ 0 0 C C/ /" - /" 0 0 C C/ /" 0 0 C 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions 0 Subject to technical change without notice. Technical Documentation 0-N -

Connections standard without built-in valve Connections dimensions -tube, bottom Height 0 mm ) C...... C....../ C/ Connection details 0 C C/ 0 0 C C/ /" - /" 0 0 C C/ /" 0 0 0 C 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions - Technical Documentation 0-N Subject to technical change without notice.

Connections standard without built-in valve Connections dimensions -tube, bottom, one behind the other Model C... Version Standard Dimensioned drawing - side view Dimensioned drawing - front view Ordering code / ) : recommended wall spacing Only possible from C.. Connection dimensions -tube, middle Model C... Version Standard Dimensioned drawing - side view Dimensioned drawing - front view Ordering code C.../ Fins at the rear ) : recommended wall spacing Connection only G / Note fixing consultation ) : recommended wall spacing Connection dimensions -tube Version Connection details Plan view For valve with dip tube, side T Distance T C... C.../ : mm : mm For valve with dip tube, bottom 0 for TKM valve, bottom Distance T C... C.../ : mm : mm T Subject to technical change without notice. Technical Documentation 0-N -

Connections standard without built-in valve Coupled convectors Convectors are supplied separately. Connections are to be installed on site Recommended connection size between the room heaters: G / (or one size larger than feed / return) ζ value=,0 applies for inlet and outlet with connection sizes from G / to G / and up to a water velocity of m/s ζ overall value = ζ value x number of inlets and outlets For height 0 mm connection size and coupling size G / From size C0 all coupled convectors can be connected at the bottom using a valve with dip tube or a TKM valve on the right of left Connection system Connection on same end Connection opposite ends, side Description Maximum length: L max = m Please provide a drawing with the order Maximum length: L max = m Please provide a drawing with the order /" /" First room heater Order of coupled room heaters (enter in "Special features" column) Middle room heater L max. = m /" /" L max. = m /" /" Last room heater /" Ordering code L max. = m Connection opposite ends, bottom Maximum length: L max = m Please provide a drawing with the order /" /" /" /" For connection dimensions, see "Connection dimensions" table Special connections Ordering code Description Version as per drawing 0 - Technical Documentation 0-N Subject to technical change without notice.

Connections version with built-in valve Version with built-in valve To ease fitting, Arbonia has developed a built-in valve system for convectors. Along with its practical advantages, this system provides a number of aesthetic features. Range available Built-in valve with adjustable k VS value (valve characteristic) integrated in header piece: - Arranged side top, left or right - As standard arranged at rear (also arranged at front as special design) - Thermostatic head ZV00000 (Z) not included, must be ordered as an accessory Connections: - -tube connection, bottom, integrated into the room heater - Connections adjacent (on valve side or middle), connection centre line mm - Flow always outside (on valve side) - Connection size: G / internal thread - Possibility of connection to a -tube system using on site H-threaded fitting ZV00000 (Z) or ZV00000 (Z) as an accessory - For convectors with a height of 0 mm on request. Maximum operating temperature: C Special versions Convectors with top grill: - Height 0 0: ordering code = AB - Height 0: on request Connection options Description Feature Ordering code Connection system Valve position side top Standard valve with thread M 0 x, Standard valve with clamp thread Valve with fine adjustment and thread M 0 x, Valve with fine adjustment and clamp thread Arrangement Connections bottom, adjacent Valve left, flow left, return left Valve right, flow right, return right Valve right, flow middle right, return middle left (max. length: 00 mm) Valve left, flow middle left, return middle right (max. length: 00 mm) Tapping size G / internal thread feed G / internal thread return VL RL Dimension drawings Model Dimension drawing Side view C../V, C...V C.../V 0 Connections: x G/" internal 0 Valve left Valve right Attention: flow always outside Subject to technical change without notice. Technical Documentation 0-N -

Air vent, Drain Air vent Description Feature Ordering code Version Air vent tapping standard version Built-in air vent with rotating outlet No air vent, only if imperative Arrangement Position recommended by the factory standard version ) Position on request ) Tapping size G / G / G / ) For position see illustration of the arrangement of the connections in the "Connection options flow / return" table ) If the tapping cannot be arranged in the required position for technical reasons, the tapping will instead be arranged in the position recommended by the factory Drain Description Feature Ordering code Version No drain, only if imperative standard version ) Drain tapping Blanking plugs fitted Arrangement Position recommended by the factory standard version ) 0 0 0 Position on request ) Tapping size G / G / ) If a drain tapping is necessary for technical reasons, this will be fitted as standard in the factory ) For position see illustration of the arrangement of the connections in the "Connection options flow / return" table ) If the tapping cannot be arranged in the required position for technical reasons, the tapping will instead be arranged in the position recommended by the factory 0 - Technical Documentation 0-N Subject to technical change without notice.

Fixing Fixing Fixing dimensions 0 H C.../ L C.../ C.../ C.../ C.../ C... C... C... C... 0 Fixing with rear lugs Name Dimension drawing Ordering code Without rear lugs standard version With rear lugs C/, C /, C/ B 0 0 0 0 C, C, C, C, C, C 0 0 0 T C/, C/, C/ 0 0 L 0 0 T Subject to technical change without notice. Technical Documentation 0-N -

Fixing Number of fixing points Number fixing points Dimension drawing L = 0, -,00 m fixing points L =,0 -,00 m fixing points / / L =,0 -,00 m / / / Attention: all models not listed above cannot be fitted with rear lugs. 0 - Technical Documentation 0-N Subject to technical change without notice.

Fixing Fixing with brackets Fixing type Version Model On wall with wall brackets (examples): Length L [mm] Number of brackets 0 00 Suitable brackets ZB000 (W) 00 000 ZB000 (W) ZB000 (W) Wall brackets: ZB000 (W) Wall brackets: ZB00 (W) Wall brackets: ZB000 (W) ZB000 (W with rearlugs ) C C/ C C C C ZB00 (W) ZB000 (W0) ZB000 (W0) 00 000 ZB000 (W0) ZB000 (W0) Wall brackets: ZB000 (W0) ZB000 (W0) ZB000 (W0) ZB000 (W0) ZB000 (W0) Wall brackets: ZB000 (W0) ZB000 (W0) ZB000 (W0) ZB000 (W0) ZB000 (W0) ZB000 (W0) On wall with wall brackets and floor brackets: C0 C C0 C C0 C 0 00 00 000 00 000 without rear lugs C0 C 0 00 00 000 Wall brackets ZB00 (W0) Wall brackets ZB00 (W0) 00 000 0 On floor with wall brackets and floor brackets: without rear lugs C0 C C0 C C0 C C0 C 0 00 00 000 00 000 0 00 00 000 Floor brackets ZB00 (W0) Floor brackets ZB00 (W0) 00 000 ) Rear lugs are only welded to convectors on request (ordering code : B) Attention: characteristics of the wall must be checked. Maximum loading capacity not referred to bracket/wall joint. Subject to technical change without notice. Technical Documentation 0-N -

Fixing Selection of further brackets Model C../ C.. C../ C.. C../ C.. C../ C.. Depth [mm] ZB000 (B0) ZB000 (B0) ZB000 (B0) ZB000 (B0) ZB000 (B0) ZB000 (B0) ZB000 (B0) ZB000 (B0) Floor fixing ZB000 (B) ZB000 (B) ZB000 (B) ZB000 (B) ZB000 (B) ZB000 (B) ZB000 (B) ZB000 (B) Wall fixing ZB00 (B0) ZB00 (W) ZB00 (B0) ZB00 (W) ZB00 (B0) ZB00 (W) ZB00 (B0) ZB00 (W) ZB00 (B0) ZB00 (W) ZB00 (B0) ZB00 (W) ZB00 (B0) ZB00 (W) ZB00 (B0) ZB00 (W) Name Description Floor brackets ZB000 (B0 B) Stepless adjustable in height: - ZB000 (B0 B0): H = mm - ZB000 (B B): H = 0 mm Surface: - Galvanised - Finished AF, CF, SF Universal bracket ZB00 (B0 B0) Stepless adjustable in height and depth Height adjustment range: H = 0 mm Can be cut on site Surface: - Galvanised - Finished AF, CF, SF 0 Wall bracket ZB00 (W W) Stepless adjustable in depth Maximum loading capacity: - ZB00 (W): 0 kg - ZB00 (W): 0 kg - ZB00 (W): 0 kg - ZB00 (W): 0 kg Surface: - Galvanised - Finished IAFI, ICFI, ISFI Please check the characteristics of the wall and choose the fixing variant and the plugs and screws to suit. - Technical Documentation 0-N Subject to technical change without notice.

Fixing Fixing with screwed feet Description Dimension drawing For models C...- C...- with a depth of mm without rear fins L Only available for convectors with connection type -tube, bottom, opposite ends (ordering code : or ) Height foot: mm -part feet cover the fixings and the fittings Screw-on brackets open to the outside are mounted on site and closed using cover plates supplied A screw-on bracket with break-out Dimensions in mm mm to the inside for thermostatic Cover: head (thermostatic head available as accessory, mounted on site) Screw-on brackets, cover plates and screws included H T Length L [mm] Number of feet 0 00 00 000 Ordering code FUS Cover plate Screw-on bracket 00 000 Fixing with soil stand bracket Description Dimension drawing Bench holder set For models C...- and C...- Can be added later, also for universal convectors Shelf not in product range For use in conjunction with bracket ZB00 (W0) Do not use shelf as bench! (see fixing as bench) L 00-00 00- BH max. 0 Length L [mm] Number of feet 0 00 00 000 00 000 Suitable brackets ZM000 (B) Bench holder set For models C...- and C...- Can be added later, also for universal convectors Seat not in product range For use in conjunction with bracket ZB00 (W0) L 00-00 00- BH max. 0 0 00 00 000 00 000 ZM000 (B) 0 Subject to technical change without notice. Technical Documentation 0-N -

Fixing 0 Fixing as bench Description Dimensioned drawing Drawing For convectors C with a depth of mm T ZB00 Convector can be used as H seat, window sill or shelf Brackets and fixing must be ZB00000 ordered separately as accessories Bench or shelf not in product range and must be provided ZB00 on site H A Brackets are finished (AF, CF or SF) B ZB00000 Dimensions in mm A: mounting on finished floor, B: mounting on unfinished floor with adjusting screw Brackets with different dimensions are available on request as special version. Selection of the brackets and fixings C0 C0/ C0 C0/ C0 C0/ C C/ C C/ C C/ C C/ C C/ C C/ C C/ C C/ C C/ Depth [mm] Height [mm] Brackets under room heater For finished floor For unfinished floor Brackets above Brackets Adjusting screws room heater Ordering Ordering Ordering Ordering Length[mm] Number code Number code Number code Number code Number 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00(B ZB00000 ZB00 00 000 (B) ) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00(B ZB00000 ZB00 00 000 (B) ) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 0 0 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 0 0 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 0 0 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 0 0 (B) (B) (B0) (B) 00 000 0 0 0 Suitable brackets ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) Fixing room heater Ordering code ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) - Technical Documentation 0-N Subject to technical change without notice.

Fixing Mounting in floor channel Wall spacing and floor spacing must match depth as a minimum Open cross-section of the grill cover must be at least 0 % Reduction of the heat output by to % (as a function of the grill cover) Panel must reach the cover grill Bottom edge of the panel must be flush with the bottom edge of the convector Types of mounting Installation situation Heat output = cold air dropping from the window above Dimension drawing W T 0-0- BA Heat output > cold air dropping from the window above Dimensions in mm BA: floor spacing W: Wall spacing W T W 0-0- BA Dimensions in mm W: outside wall spacing W: inside wall spacing BA: floor spacing 0 Subject to technical change without notice. Technical Documentation 0-N -

Pressure versions, Fittings, Surface finishes, Special versions Pressure versions, fittings and attachments Ordering code Description Standard version bar (00 kpa) High-pressure version 0 bar (000 kpa) 0 Version Description Dimension drawing With top grill Reduction in heat output: % Top grills for screwless mounting. For, convectors with fins on rear, special fixings are included Bracket ZB00 (W0) cannot be used with welded top grill and galvanised convector Dimensions in mm Ordering code AB Surface finishes 0 Description Finish Ordering code Colour Ordering code /0 AllFinish in white Pure white RAL 00 standard version AF RAL 00 Traffic white RAL 0 AF RAL 0 Primed in cream-white ET Primed in cream-white and packed in plastic sheet EF ColorFinish, finished in standard colour ) RAL colour SuperFinish in colour of choice ) ) SF ) For information on ordering, see ordering process section : General information and colour chart ) Not in all colours CF CF SF Sanitary colour ) Manufacturer's colour Arbonia special colour ) Colour number Ordering code Colour number from colour card Colour number manufacturer's colour SuperFinish in gloss silver SF GLS Clear lacquer TF Textured paint after priming Pure white RAL 00 standard version Traffic white RAL 0 SL SL RAL RAL 00 0 In colour of choice (manufacturer's colour) ) ) ) ) In colour of choice (Arbonia special colour) KL KL Manufacturer's colour Colour number manufacturer's colour Arbonia special colour ) Hot-dip galvanised, outside, for wet rooms Without paint finish With textured paint in pure white RAL 00 standard version With textured paint in traffic white RAL 0 ) ) With structured paint in colour of choice (manufacturer's colour) With textured paint in colour of choice (sanitary colour) ) ) With textured paint in colour of choice (Arbonia special colour) ) ) Anti-microbial coating Pure white RAL 00 standard version Traffic white RAL 0 ZN ZL ZL ZK ZK ZK AM AM RAL RAL Manufacturer's colour Sanitary colour ) Arbonia special colour ) RAL RAL 00 0 Colour number manufacturer's colour 00 0 - Technical Documentation 0-N Subject to technical change without notice.

T W Convectors Pressure versions, Fittings, Surface finishes, Special versions Special versions Ordering code Description Version as per drawing Angled version Angle α can be between 0 and 0 Number of angles limited Only available for versions with top grill (ordering code : AB) Not available in all dimensions in hot-dip galvanised version. On request Convector must be suitable for transport Please provide a drawing with dimensions or template with the order Description / dimension drawings Ordering code L L W T L L, L: Length of the limb, measured on the wall α: Angle W: Wall spacing L 0 Subject to technical change without notice. Technical Documentation 0-N -

Pressure versions, Fittings, Surface finishes, Special versions Curved version Minimum bending radius R min : 00 mm Only for convectors in high-pressure version (ordering code : 0) Not in all dimensions in hot-dip galvanised version. On request Convector must be suitable for transport Please provide a drawing with dimensions or template with the order Special top grill on request Description / dimension drawings L W Ordering code R Inside radius W T L R Outside radius T 0 W: Wall spacing R: Bending radius (inside radius / outside radius) 0 - Technical Documentation 0-N Subject to technical change without notice.

Heat output per room heater Height 0 mm with heat outputs as a function of length and depth Model C0/ C0 C0/ C0 Height H [mm] 0 0 0 0 Depth T [mm] Weight per metre M [kg/m],0,,,0 Surface per metre A [m²/m] 0,,,,0 Volume per metre V [dm³/m] 0,,,, Standard water flow rate per metre q ms [kg/h m],,,0, Radiated portion s [%] 0 Radiator classification n [Exp],,,, Φ L ΔT K [Watt/m] 0 Length L [mm] Φ S ΔT K // C Φ S ΔT K: standard heat output at // C (ΔT K) (EN ) ΔT K: standard temperature rise Weight per radiator > kg (dry) Φ S ΔT K // C Φ S ΔT K // C Φ S ΔT K // C 0 00 00 00 00 000 0 0 0 00 00 0 0 0 0 00 00 00 00 0 0 00 0 00 0 0 0 00 00 0 0 0 00 0 000 0 0 00 00 00 000 0 0 0 00 0 00 0 0 00 00 00 0 0 0 00 00 00 000 0 Max. length L [mm] 000 000 000 000 0 Subject to technical change without notice. Technical Documentation 0-N -

Heat output per room heater Height 0 mm with heat outputs as a function of length and depth 0 Model C0/ C0 C0/ C0 Height H [mm] 0 0 0 0 Depth T [mm] Weight per metre M [kg/m],,0,, Surface per metre A [m²/m],,,, Volume per metre V [dm³/m],,,, Standard water flow rate per metre q ms [kg/h m],,,, Radiated portion s [%] 0 0 0 0 Radiator classification n [Exp],,,, Φ L ΔT K [Watt/m] 0 Length L [mm] Φ S ΔT K // C Φ S ΔT K: standard heat output at // C (ΔT K) (EN ) ΔT K: standard temperature rise Weight per radiator > kg (dry) Φ S ΔT K // C Φ S ΔT K // C Φ S ΔT K // C 0 0 00 00 00 00 000 0 0 0 0 0 0 0 00 0 00 0 0 00 0 0 0 00 0 00 00 0 00 0 00 0 00 00 0 000 0 0 0 0 00 00 0 00 0 0 000 00 0 0 00 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 00 000 Max. length L [mm] 000 000 000 000 - Technical Documentation 0-N Subject to technical change without notice.

Heat output per room heater Height 0 mm with heat outputs as a function of length and depth Model C/ C C/ C Height H [mm] 0 0 0 0 Depth T [mm] Weight per metre M [kg/m],,,, Surface per metre A [m²/m],,,, Volume per metre V [dm³/m],,,, Standard water flow rate per metre q ms [kg/h m],,,0, Radiated portion s [%] 0 Radiator classification n [Exp],,0,, Φ L ΔT K [Watt/m] Length L [mm] Φ S ΔT K // C Φ S ΔT K: standard heat output at // C (ΔT K) (EN ) ΔT K: standard temperature rise Weight per radiator > kg (dry) Φ S ΔT K // C Φ S ΔT K // C Φ S ΔT K // C 0 00 00 0 00 0 00 0 000 0 0 00 0 0 00 0 00 0 0 0 0 00 0 00 00 0 0 00 0 00 0 0 0 00 0 0 00 0 00 00 000 0 0 00 00 00 000 0 0 0 00 00 0 00 0 0 00 0 0 0 00 00 0 0 00 000 Max. length L [mm] 000 000 000 000 0 Subject to technical change without notice. Technical Documentation 0-N -

Heat output per room heater Height 0 mm with heat outputs as a function of length and depth 0 Model C/ C C/ C Height H [mm] 0 0 0 0 Depth T [mm] Weight per metre M [kg/m],,,, Surface per metre A [m²/m],,,, Volume per metre V [dm³/m],,,, Standard water flow rate per metre q ms [kg/h m], 0,,, Radiated portion s [%] 0 0 0 0 Radiator classification n [Exp],,,, Φ L ΔT K [Watt/m] 0 0 Length L [mm] Φ S ΔT K // C Φ S ΔT K: standard heat output at // C (ΔT K) (EN ) ΔT K: standard temperature rise Weight per radiator > kg (dry) Φ S ΔT K // C Φ S ΔT K // C Φ S ΔT K // C 0 0 00 00 0 00 00 00 0 000 0 0 0 0 0 00 00 00 0 0 0 00 00 00 00 00 0 0 0 0 0 00 00 00 0 00 0 000 0 00 0 00 00 0 000 0 0 0 0 00 00 00 0 0 00 00 0 00 0 00 0 00 0 00 000 Max. length L [mm] 000 000 000 000-0 Technical Documentation 0-N Subject to technical change without notice.

Heat output per room heater Height 0 mm with heat outputs as a function of length and depth Model C/ C C/ C Height H [mm] 0 0 0 0 Depth T [mm] Weight per metre M [kg/m],,,, Surface per metre A [m²/m],0,,, Volume per metre V [dm³/m],,,, Standard water flow rate per metre q ms [kg/h m],,,, Radiated portion s [%] 0 Radiator classification n [Exp],,,, Φ L ΔT K [Watt/m] Length L [mm] Φ S ΔT K // C Φ S ΔT K: standard heat output at // C (ΔT K) (EN ) ΔT K: standard temperature rise Weight per radiator > kg (dry) Φ S ΔT K // C Φ S ΔT K // C Φ S ΔT K // C 0 00 00 00 0 00 0 000 0 0 0 0 0 00 0 00 0 0 00 0 00 00 00 00 0 0 0 00 0 00 0 0 00 000 0 0 00 00 0 00 000 0 0 0 0 0 00 00 00 00 0 0 00 0 0 00 0 00 0 00 00 000 0 Max. length L [mm] 000 000 000 000 0 Subject to technical change without notice. Technical Documentation 0-N -

Heat output per room heater Height 0 mm with heat outputs as a function of length and depth 0 Model C/ C C/ C Height H [mm] 0 0 0 0 Depth T [mm] Weight per metre M [kg/m] 0,,,0, Surface per metre A [m²/m],,,, Volume per metre V [dm³/m],,, 0, Standard water flow rate per metre q ms [kg/h m],, 0,0,0 Radiated portion s [%] 0 0 0 0 Radiator classification n [Exp],,,, Φ L ΔT K [Watt/m] 0 0 Length L [mm] Φ S ΔT K // C Φ S ΔT K: standard heat output at // C (ΔT K) (EN ) ΔT K: standard temperature rise Weight per radiator > kg (dry) Φ S ΔT K // C Φ S ΔT K // C Φ S ΔT K // C 0 0 0 0 00 0 00 00 00 000 0 0 0 0 0 0 0 0 00 0 00 0 0 00 00 0 0 00 00 00 0 0 0 0 0 00 00 0 00 000 0 00 00 0 00 0 000 0 0 0 00 00 00 00 00 0 0 00 00 0 0 00 00 0 00 0 000 0 0 Max. length L [mm] 000 000 00 - Technical Documentation 0-N Subject to technical change without notice.

Heat output per room heater Height 0 mm with heat outputs as a function of length and depth Model C/ C C/ C Height H [mm] 0 0 0 0 Depth T [mm] Weight per metre M [kg/m],, 0,,0 Surface per metre A [m²/m],0,,0, Volume per metre V [dm³/m],,,, Standard water flow rate per metre q ms [kg/h m],, 0,,0 Radiated portion s [%] 0 Radiator classification n [Exp],0,,, Φ L ΔT K [Watt/m] 0 Length L [mm] Φ S ΔT K // C Φ S ΔT K: standard heat output at // C (ΔT K) (EN ) ΔT K: standard temperature rise Weight per radiator > kg (dry) Φ S ΔT K // C Φ S ΔT K // C Φ S ΔT K // C 0 0 0 00 0 00 0 00 00 00 0 000 0 0 0 0 00 0 0 0 00 0 0 00 00 0 00 00 0 0 00 0 0 0 00 0 00 0 0 000 00 000 0 0 00 00 0 00 0 000 0 00 0 0 00 0 00 00 00 0 0 00 0 00 0 00 00 0 000 Max. length L [mm] 000 000 000 000 0 Subject to technical change without notice. Technical Documentation 0-N -

Heat output per room heater Height 0 mm with heat outputs as a function of length and depth 0 Model C/ C C/ C Height H [mm] 0 0 0 0 Depth T [mm] Weight per metre M [kg/m],,0,, Surface per metre A [m²/m],0,,0, Volume per metre V [dm³/m],,,, Standard water flow rate per metre q ms [kg/h m],,,, Radiated portion s [%] 0 0 0 0 Radiator classification n [Exp],,0,, Φ L ΔT K [Watt/m] 0 Length L [mm] Φ S ΔT K // C Φ S ΔT K: standard heat output at // C (ΔT K) (EN ) ΔT K: standard temperature rise Weight per radiator > kg (dry) Φ S ΔT K // C Φ S ΔT K // C Φ S ΔT K // C 0 0 0 00 00 00 00 00 000 0 0 0 00 00 0 0 00 0 0 00 0 0 00 0 00 0 00 0 0 0 00 0 00 0 00 0 0 000 0 0 0 0 00 0 0 00 0 00 0 000 0 0 0 00 0 00 00 0 0 00 00 00 0 00 0 00 Max. length L [mm] 00 00 000 - Technical Documentation 0-N Subject to technical change without notice.

Technical data per metre Height H [mm] 0 0 0 0 Depth T [mm] Model ΦΔT 0K 0/0/ C [Watt/m] Heat output EN Φ L ΔT K // C [Watt/m] ΦΔT K 0// C [Watt/m] ΦΔT 0K // C [Watt/m] Individual calculation of heat outputs see section : General information Radiator classification n [Exp] Weight per metre M [kg/m] Surface per metre A [m²/m] Volume per metre V [dm³/m] Standard water flow rate per metre q ms [kg/h m] Radiated portion s [%] C0/,,0 0, 0,, C0,,,,, C0/ 0,,,,,0 C0,,0,0,, 0 C0/,,,,, 0 C0 00,,0,,, 0 C0/ 0,,,,, 0 C0 0,,,,, 0 C/,,,,, C,0,,,, C/ 0,,,,,0 C 0,,,,, 0 C/ 0,,,,, 0 C 0,,,, 0, 0 C/ 0,,,,, 0 C,,,,, 0 C/,,,0,, C,,,,, C/,,,,, C,,,,, 0 C/, 0,,,, 0 C 0 0,,,,, 0 C/ 0 0 0 0,,0,, 0,0 0 C 0,,, 0,,0 0 C/,0,,0,, C 0 0 0,,,,, C/, 0,,0, 0, C 0,,0,,,0 0 C/ 0,,,0,, 0 C,0,0,,, 0 C/ 0,,,0,, 0 C 0,,,,, 0 0 Subject to technical change without notice. Technical Documentation 0-N -

Convector WVO Description Model Standard without built-in valve C....../W Explanation C : convector model code... : height in cm... : number of tubes carrying water / : with fins at rear W : with shield for radiated heat Example C/W C : convector : height cm : tubes carrying water / : with fins at rear W : with shield for radiated heat Model C....../WV Version with built-in V: with built-in valve valve 0 General Form and function combine in modern architecture in a harmonious manner. Arbonia convectors support the architect and client in this harmony: the clear emphasis of the horizontal line, clean side connections and the fine structure of the cover permit open installation. High heat output from small dimensions and the diverse range round off the attractive image of this room heater. Convectors WVO are GUV-compliant in the special version with top grill. On convectors in WVO-version, the continuous, insulated shield reduces the heat radiated in this direction. Arbonia recommends the use of convectors WVO for window areas. Rear view: Layout of the shield for radiated heat: Aluminiumlining Range available depths:,, and mm - All models with fins at rear and shield for radiated heat on the rear heights: 0, 0, 0 and 0 mm Length: - 0 00 mm: steps: 00 mm - 00 000 mm: steps: 0 mm (manufacturing tolerance: ± mm, measured at C) - Maximum length 00 000 mm Shield for radiated heat: - Continuous, sheet metal shielding for the rear fins, cannot be removed - With polystyrene insulation and aluminium lining as reflective shield - k value < 0, Watt/m K -tube connections Polystyrene 0 mm Steel sheet mm - Technical Documentation 0-N Subject to technical change without notice.

Convector WVO Description Special versions -tube connections Version with built-in valve Built-in air vent with rotating outlet High-pressure version 0 bar (000 kpa) Top grill (GUV-compliant) Screwed feet Angled or curved version Fixing as bench: - For convectors with depth mm - Order brackets as accessories Surface finishes AllFinish in traffic white (AF) RAL 0 AllFinish in pure white (AF) RAL 00 Primed in cream-white (ET) Primed in cream-white and packed in plastic sheet (EF) ColorFinish in standard colour (CF) SuperFinish, finished in colour of choice (SF) ) Anti-microbial coating (AM) Warning on painting of convectors WVO on site The polystyrene insulation for the shield for radiated heat must not come into contact with solvents or paint thinners. The paint finish is not allowed to be baked. Forced drying at C is allowed. All finishes are baked at 0 C. For detailed information see "Colour Fashion of the Arbonia Radiators". Operating conditions For closed water heating systems in accordance with DIN 0 and water quality in accordance with VDI Can be used in conventional and low temperature areas Can be used for district heating and high-rise buildings (high permissible operating pressure) Not suitable for steam-based heating systems Length expansion: 0, mm/m at a temperature difference of K Properties of relevance to operation Standardversion High-pressure version Operating pressure [bar (kpa)],0 (00) 0,0 (000) Test pressure [bar (kpa)], (0),0 (00) Max. temperature [ C] Minimum water flow rate The minimum water flow rate must not be less than 0 % of the standard water flow rate in accordance with EN to avoid a reduction in the heat output. This applies both to connection on same end and on opposite ends. Pressure drop Δp Δp = ζ x ρ/ x w Δp: Pressure drop [Pa] ζ: Resistance coefficient Zeta [] ρ: Density of the water [kg/m ] w: Water velocity [m/s] The ζ values are given in the connection table and apply for a water velocity of up to m/s. Heat outputs The heat outputs given are determined and registered in accordance with the guidelines in EN : DIN CERTCO registered. RAL tested and registered. Tender text Room heaters with up to five 0 x x, mm steel tubes arranged one behind the other and up to four 0 x x, mm steel tubes arranged one above the other with convector fins and collectors on the ends connected by hidden welds and rounded edges all round with R min = mm. Ready to install with to connection threads on the ends in the collectors for flow and return as well as air vent and drain. Shield for radiated heat with polystyrene insulation and aluminium laminate, cannot be removed, with a k-value < 0, Watt/m K. Version with permanently fitted top grill (at extra charge) complies with the basic principles for the testing of the health and safety of room heaters (statutory accident insurance). Priming in accordance with DIN 00 part and powder coating in accordance with DIN 00 part. Pressure and leak tested. Heat output tested and measured in accordance with EN. CE marked. Suitable for closed water heating systems in accordance with DIN 0 and water quality in accordance with VDI. Maximum permissible operating temperature C Max. operating pressure: bar / 00 kpa 0 bar / 000 kpa Suitably packed for transport. 0 ) Not in all colours Subject to technical change without notice. Technical Documentation 0-N -

Convector WVO Connections standard without built-in valve Connection options flow / return Connection system Ord. code ζ value Arrangement Ordering code Connec. size Ordering code Flow Return Dimension drawings -tube, side,0,0 G / G / G / See page Connection dimensions -tube, side -tube, side and bottom,0,0 G / G / G / See page Connection dimensions -tube, side and "Connections dimensions -tube, bottom" -tube, bottom,0,0 -tube, bottom, one behind the other,0,0 G / G / G / G / G / G / See page Connection dimensions -tube, bottom See page Connection dimensions -tube, bottom, one behind the other Only possible from C../W -tube, bottom, middle-middle,,0,0 G / vertical underside ) -tube, for valve with dip tube, side,with dip tube Ø mm -tube, for valve with dip tube, bottom,with dip tube Ø mm 0,0,0 G / 0,0,0 G / See page Connection dimensions -tube, middle See page Connection dimensions -tube See page Connection dimensions -tube -tube, for TKM valve, bottom, with dip tube,0,0 G / See page Connection dimensions -tube 0 ) Maximum length: 00 mm L: recommended position for air vent tapping: Standard baffle; baffle with Ø mm hole; valve with dip tube; TKM valve On models C0/W the connections in arrangement and are only possible in G /. - Technical Documentation 0-N Subject to technical change without notice.

Convector WVO Connections standard without built-in valve Connection dimensions -tube, side C0/W ) C....../W C....../W Connection details Height 0 mm ) Height 0 mm ) C/W 0 0 C0/W C/W 0 0 C0/W C/W /" - /" 0 0 C0/W C/W 0 0 0 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions ) Only G / (for arrangement feature : or ) Subject to technical change without notice. Technical Documentation 0-N -

Convector WVO Connections standard without built-in valve Connection dimensions -tube, side C/W C....../W C....../W Connection details Height 0 mm ) Height 0 mm ) C/W 0 0 C/W C/W 0 0 C/W C/W 0 0 /" - /" C/W C/W 0 0 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions -0 Technical Documentation 0-N Subject to technical change without notice.

Convector WVO Connections standard without built-in valve Connections dimensions -tube, bottom C0/W C....../W C....../W Connection details Height 0 mm ) Height 0 mm ) C/W 0 0 C0/W C/W /" - /" C0/W C/W 0 0 0 0 /" C0/W C/W 0 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions 0 Subject to technical change without notice. Technical Documentation 0-N -

Convector WVO Connections standard without built-in valve Connections dimensions -tube, bottom C/W C....../W C....../W Connection details Height 0 mm ) Height 0 mm ) C/W 0 0 C/W C/W /" - /" C/W C/W 0 0 0 0 /" C/W C/W 0 0 0 Dimensions in mm ) Wall and floor spacings are recommended minimum dimensions - Technical Documentation 0-N Subject to technical change without notice.

Convector WVO Connections standard without built-in valve Connections dimensions -tube, bottom, one behind the other Model Version Dimensioned drawing - side view Dimensioned drawing - front view C.../W Version with shield for radiated heat min. 00 Ordering code / Only possible from C../W Connection dimensions -tube, middle Model Version Dimensioned drawing - side view Dimensioned drawing - front view C.../W Version with shield min. 00 for radiated heat Ordering code Connection only G / Note fixing consultation Connection dimensions -tube Version Connection details Plan view For valve with dip tube, side T Distance T C.../W : mm For valve with dip tube, bottom T Distance T for TKM valve, bottom C.../W : mm 0 Subject to technical change without notice. Technical Documentation 0-N -

Convector WVO Connections standard without built-in valve Coupled convectors Convectors are supplied separately. Connections are to be installed on site Recommended connection size between the room heaters: G / (or one size larger than feed / return) ζ value=,0 applies for inlet and outlet with connection sizes from G / to G / and up to a water velocity of m/s ζ overall value = ζ value x number of inlets and outlets For height 0 mm connection size and coupling size G / From size C0 all coupled convectors can be connected at the bottom using a valve with dip tube or a TKM valve on the right of left Connection system Connection on same end Connection opposite ends, side Connection opposite ends, bottom Description Maximum length: L max = m Please provide a drawing with the order Maximum length: L max = m Please provide a drawing with the order Maximum length: L max = m Please provide a drawing with the order /" /" /" For connection dimensions, see "Connection dimensions" table Order of coupled room heaters(enter in "Special features" column) First room heater Middle room heater L max. = m /" /" L max. = m /" /" L max. = m /" /" Last room heater /" /" Ordering code Special connections Ordering code Description Version as per drawing 0 - Technical Documentation 0-N Subject to technical change without notice.

Convector WVO Connections version with built-in valve Version with built-in valve To ease fitting, Arbonia has developed a built-in valve system for convectors. Along with its practical advantages, this system provides a number of aesthetic features. Range available Built-in valve with adjustable k VS value (valve characteristic) integrated in header piece: - Arranged side top, left or right - As standard arranged at rear (also arranged at front as special design) - Thermostatic head ZV00000 (Z) not included, must be ordered as an accessory Connections: - -tube connection, bottom, integrated into the room heater - Connections adjacent (on valve side or middle), connection centre line mm - Flow always outside (on valve side) - Connection size: G / internal thread - Possibility of connection to a -tube system using on site H- threaded fitting ZV00000 (Z) or ZV00000 (Z) as an accessory - For convectors with a height of 0 mm on request. Maximum operating temperature: C Special versions Convectors with top grill: - Height 0 0: ordering code = AB - Height 0: on request Connection options Model Dimension drawing Side view C.../WV 0 Connections: x G/" internal Valve left Valve right Attention: flow always outside Dimension drawings Description Feature Ordering code Connection system Valve position side top Standard valve with thread M 0 x, Standard valve with clamp thread Valve with fine adjustment and thread M 0 x, Valve with fine adjustment and clamp thread Arrangement Connections bottom, adjacent Valve left, flow left, return left Valve right, flow right, return right Valve right, flow middle right, return middle left (max. length: 00 mm) Valve left, flow middle left, return middle right (max. length: 00 mm) Tapping size G / internal thread feed G / internal thread return VL RL 0 Subject to technical change without notice. Technical Documentation 0-N -

Convector WVO Air vent, Drain Air vent Description Feature Ordering code Version Air vent tapping standard version Built-in air vent with rotating outlet No air vent, only if imperative Arrangement Position recommended by the factory standard version ) Position on request ) Tapping size G / G / G / ) For position see illustration of the arrangement of the connections in the "Connection options flow / return" table ) If the tapping cannot be arranged in the required position for technical reasons, the tapping will instead be arranged in the position recommended by the factory Drain Description Feature Ordering code Version No drain, only if imperative standard version ) Drain tapping Blanking plugs fitted Arrangement Position recommended by the factory standard version ) 0 0 0 Position on request ) Tapping size G / G / ) If a drain tapping is necessary for technical reasons, this will be fitted as standard in the factory ) For position see illustration of the arrangement of the connections in the "Connection options flow / return" table ) If the tapping cannot be arranged in the required position for technical reasons, the tapping will instead be arranged in the position recommended by the factory 0 - Technical Documentation 0-N Subject to technical change without notice.

Convector WVO Fixing Fixing Safety distance convector WVO Minimum distance for single pane safety glass (ESG): recommendation 00 mm 00 min Shield for radiated Fixing with brackets Fixing type Version Model Length L [mm] Number of brackets Suitable brackets On wall with wall brackets and floor brackets: C0/W C/W C0/W C/W C0/W C/W 0 00 00 000 00 000 without rear lugs C0/W C/W 0 00 00 000 Wall brackets ZB00 (W0) Wall brackets ZB00 (W0) On floor with wall brackets and floor brackets: without rear lugs C0/W C/W C0/W C/W C0/W C/W 00 000 0 00 00 000 00 000 0 00 ZB00 (W0) C0/W C/W 00 000 0 Floor brackets ZB00 (W0) Floor brackets ZB00 (W0) 00 000 Attention: characteristics of the wall must be checked. Maximum loading capacity not referred to bracket/wall joint. Subject to technical change without notice. Technical Documentation 0-N -

Convector WVO Fixing Selection of further brackets Model C../W C../W C../W C../W Depth [mm] Floor fixing ZB000 (B0) ZB000 (B) ZB00 (B0) ZB000 (B0) ZB000 (B) ZB00 (B0) ZB000 (B0) ZB000 (B) ZB00 (B0) ZB000 (B0) ZB000 (B) ZB00 (B0) Wall fixing ZB00 (W) ZB00 (W) ZB00 (W) ZB00 (W) Name Description Floor brackets ZB000 (B0 B) Stepless adjustable in height: - ZB000 (B0 B0): H = mm - ZB000 (B B): H = 0 mm Surface: - Galvanised - Finished AF, CF, SF Universal bracket ZB00 (B0 B0) Stepless adjustable in height and depth Height adjustment range: H = 0 mm Can be cut on site Surface: - Galvanised - Finished AF, CF, SF 0 Wall bracket ZB00 (W W) Stepless adjustable in depth Maximum loading capacity: - ZB00 (W): 0 kg - ZB00 (W): 0 kg - ZB00 (W): 0 kg - ZB00 (W): 0 kg Surface: - Galvanised - Finished IAFI, ICFI, ISFI Please check the characteristics of the wall and choose the fixing variant and the plugs and screws to suit. - Technical Documentation 0-N Subject to technical change without notice.

Convector WVO Fixing Fixing with screwed feet Description Dimension drawing For convectors WVO with a depth of mm L Only available for convectors with connection type -tube, bottom, opposite ends (ordering code : or ) Height foot: mm -part feet cover the fixings and the fittings Screw-on brackets open to the outside are mounted on site and closed using cover plates supplied A screw-on bracket with break-out mm to the inside for thermostatic head (thermostatic head available as accessory, mounted on site) Dimensions in mm Screw-on brackets, cover plates and Cover: screws included T WVO overhang Length L [mm] Number of feet 0 00 00 000 Ordering code FUS 00 000 Cover plate Screw-on bracket Fixing with soil stand bracket Description Bench holder set For models C...-/W and C...-/W Can be added later, also for universal convectors Shelf not in product range Height foot: mm For use in conjunction with bracket ZB00 (W0) Not suitable for use as seat Dimension drawing L 00-00 00- BH max. 0 Length L [mm] Number of feet 0 00 00 000 00 000 Suitablebrackets ZM000 (B) Bench holder set For models C...-/W and C...-/W Can be added later, also for universal convectors Seat not in product range Height foot: mm For use in conjunction with bracket ZB00 (W0) L 00-00 00- BH max. 0 0 00 00 000 00 000 ZM000 (B) 0 Subject to technical change without notice. Technical Documentation 0-N -

Convector WVO Fixing 0 Fixing as bench Description Dimension drawing Drawing For convectors WVO with a depth of mm T ZB00 Convector can be used as H seat, window sill or shelf Brackets and fixing must be ZB00000 ordered separately as accessories Bench or shelf not in product range and must be provided ZB00 on site H A Brackets are finished (AF, CF or SF) B ZB00000 Dimensions in mm A: mounting on finished floor, B: mounting on unfinished floor with adjusting screw Brackets with different dimensions are available on request as special version. Selection of the brackets and fixings Convector WVO C0/W C0/W C0/W C0/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W Depth [mm] Height [mm] Brackets under room heater For finished floor For unfinished floor Brackets above Brackets Adjusting screws room heater Ordering Ordering Ordering Ordering Length[mm] Number code Number code Number code Number code Number 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00000 ZB00 00 000 B (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00000 ZB00 00 000 B (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 0 0 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 0 0 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 0 0 (B) (B) (B0) (B) 00 000 0 00 ZB00 ZB00 ZB00000 ZB00 00 000 0 0 (B) (B) (B0) (B) 00 000 0 0 0 Suitable brackets ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) Fixing room heater Ordering code ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) ZB00 (B) - Technical Documentation 0-N Subject to technical change without notice.

Convector WVO Pressure versions, Fittings, Surface finishes, Special versions Pressure versions, fittings and attachments Ordering code Description Standard version bar (00 kpa) High-pressure version 0 bar (000 kpa) 0 Version Description Dimension drawing With top grill Reduction in heat output: % Top grills for screwless mounting. For, convectors with fins on rear, special fixings are included Bracket ZB00 (W0) cannot be used with welded top grill and galvanised convector Dimensions in mm Ordering code AB Surface finishes Description Finish Ordering code Colour Ordering code /0 AllFinish in white Pure white RAL 00 standard version AF RAL 00 Traffic white RAL 0 AF RAL 0 Primed in cream-white ET Primed in cream-white and packed in plastic sheet EF ColorFinish, finished in standard colour ) RAL colour SuperFinish in colour of choice ) ) SF ) For information on ordering, see ordering process section : General information and colour chart ) Not in all colours Warning on painting of convectors WVO on site The polystyrene insulation for the shield for radiated heat must not come into contact with solvents or paint thinners. The paint finish is not allowed to be baked. Forced drying at C is allowed. Special versions CF CF SF Sanitary colour ) Manufacturer's colour Arbonia special colour ) Colour number Ordering code Colour numberfrom colour card Colour numbermanufacturer's colour SuperFinish in gloss silver SF GLS Anti-microbial coating Pure white RAL 00 standard version Traffic white RAL 0 Ordering code Description Version as per drawing AM AM RAL RAL 00 0 0 Subject to technical change without notice. Technical Documentation 0-N -

T W Convectors Convector WVO Pressure versions, Fittings, Surface finishes, Special versions Angled version Angle α can be between 0 and 0 Number of angles unlimited Only available for versions with top grill (ordering code : AB) Not available in all dimensions in hot-dip galvanised version. Please request information Convector must be suitable for transport Please provide a drawing with dimensions or template with the order Description / dimension drawings Ordering code L W T L L L, L: Length of the limb, measured on the wall α: Angle W: Wall spacing L 0 - Technical Documentation 0-N Subject to technical change without notice.