RHK Technology Brief

Similar documents
Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization

ADHESION OF AN AXISYMMETRIC ELASTIC BODY: RANGES OF VALIDITY OF MONOMIAL APPROXIMATIONS AND A TRANSITION MODEL

SUPPLEMENTARY INFORMATION

Instrumentation and Operation

Cantilever tilt compensation for variable-load atomic force microscopy

A General Equation for Fitting Contact Area and Friction vs Load Measurements

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

Module 26: Atomic Force Microscopy. Lecture 40: Atomic Force Microscopy 3: Additional Modes of AFM

Supporting Information. Interfacial Shear Strength of Multilayer Graphene Oxide Films

Chapter 2 Correlation Force Spectroscopy

Scanning Probe Microscopy. Amanda MacMillan, Emmy Gebremichael, & John Shamblin Chem 243: Instrumental Analysis Dr. Robert Corn March 10, 2010

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Friction at the Nanometer Scale: Recent Experimental Advances

Princeton University. Adhsion and Interfacial Failure in Drug Eluting Stents

M. Enachescu Materials Sciences Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720

Beetle UHV VT AFM / STM

Enrico Gnecco Department of Physics. University of Basel, Switzerland

Lecture 4 Scanning Probe Microscopy (SPM)

Frictional characteristics of exfoliated and epitaxial graphene

Lecture 12: Biomaterials Characterization in Aqueous Environments

Features of static and dynamic friction profiles in one and two dimensions on polymer and atomically flat surfaces using atomic force microscopy

Point mass approximation. Rigid beam mechanics. spring constant k N effective mass m e. Simple Harmonic Motion.. m e z = - k N z

Intermittent-Contact Mode Force Microscopy & Electrostatic Force Microscopy (EFM)

force measurements using friction force microscopy (FFM). As discussed previously, the

Additional information on Rev. Sci. Instrum. H. S. Khare and D. L. Burris

SUPPLEMENTARY INFORMATION

3.052 Nanomechanics of Materials and Biomaterials Thursday 02/15/07 Prof. C. Ortiz, MIT-DMSE I LECTURE 4: FORCE-DISTANCE CURVES

Atomic Force Microscopy (AFM) Part I

Nanotribology. Judith A. Harrison & Ginger M. Chateauneuf. Chemistry Department United States Naval Academy Annapolis, MD

Scanning Force Microscopy

STM: Scanning Tunneling Microscope

Atomic Force Microscopy Study of an Ideally Hard Contact: The Diamond(111)/Tungsten Carbide Interface

Material Anisotropy Revealed by Phase Contrast in Intermittent Contact Atomic Force Microscopy

Nano-Scale Effect in Adhesive Friction of Sliding Rough Surfaces

Noninvasive determination of optical lever sensitivity in atomic force microscopy

Atomic Force Microscopy imaging and beyond

Outline Scanning Probe Microscope (SPM)

MAKING, BREAKING AND SLIDING OF NANOMETER-SCALE CONTACTS

Nanoscale Effects of Friction, Adhesion and Electrical Conduction in AFM Experiments

Introductory guide to measuring the mechanical properties of nanoobjects/particles

Nitride HFETs applications: Conductance DLTS

AFM for Measuring Surface Topography and Forces

Supplementary Materials. Mechanics and Chemistry: Single Molecule Bond Rupture Forces Correlate with

SUPPLEMENTARY INFORMATION

instruments anasys Nanoscale Thermal Analysis Craig Prater, CTO Research Challenges for Nanomanufacturing Systems Februay th, 2008

NIS: what can it be used for?

Fractional Resonance Excitation in Dynamic Friction Force Microscopy

NANOTRIBOLOGY - The road to no WEAR! by Richie Khandelwal (MT03B023) & Sahil Sahni (MT03B024)

SOLID STATE PHYSICS PHY F341. Dr. Manjuladevi.V Associate Professor Department of Physics BITS Pilani

AFM Studies of Pristine PCBM Changes Under Light Exposure. Erin Chambers

General concept and defining characteristics of AFM. Dina Kudasheva Advisor: Prof. Mary K. Cowman

Linker Dependent Bond Rupture Force Measurements in Single-Molecule Junctions

Performance and Control of the Agilent Nano Indenter DCM

Program Operacyjny Kapitał Ludzki SCANNING PROBE TECHNIQUES - INTRODUCTION

FEM-SIMULATIONS OF VIBRATIONS AND RESONANCES OF STIFF AFM CANTILEVERS

EE C247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2014 C. Nguyen PROBLEM SET #4

Scanning Force Microscopy II

Supplementary Materials

CHARACTERIZATION of NANOMATERIALS KHP

Simple Harmonic Motion and Damping

Contents. Preface XI Symbols and Abbreviations XIII. 1 Introduction 1

Effect of sliding velocity on capillary condensation and friction force in a nanoscopic contact

Use of chemically modified AFM tips as a powerful tool for the determination of surface energy of functionalised surfaces

Simulation of atomic force microscopy operation via three-dimensional finite element modelling

Practical Method to Limit Tip Sample Contact Stress and Prevent Wear in Amplitude Modulation Atomic Force Microscopy

Materials Reliability Division, National Institute of Standards and Technology, Boulder, CO 80305

MEMS Metrology. Prof. Tianhong Cui ME 8254

W. DING, A. J. HOWARD, M.D. MURTHY PERI and C. CETINKAYA*

DETERMINATION OF THE ADHESION PROPERTIES OF MICA VIA ATOMIC FORCE SPECTROSCOPY

Improving the accuracy of Atomic Force Microscope based nanomechanical measurements. Bede Pittenger Bruker Nano Surfaces, Santa Barbara, CA, USA

SUPPLEMENTARY NOTES Supplementary Note 1: Fabrication of Scanning Thermal Microscopy Probes

Department of Engineering Mechanics, SVL, Xi an Jiaotong University, Xi an

Supplementary Information

And Manipulation by Scanning Probe Microscope

Crystalline Surfaces for Laser Metrology

Introduction to Scanning Tunneling Microscopy

INTRODUCTION TO SCA\ \I\G TUNNELING MICROSCOPY

The velocity dependence of frictional forces in point-contact friction

Application Note #149 Improving the Accuracy of Nanomechanical Measurements with Force-Curve-Based AFM Techniques

Quantitative Nanomechanical Measurements in HybriD TM Mode Atomic Force Microscopy

Size dependence of the mechanical properties of ZnO nanobelts

Contents. What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages

SPM 150 Aarhus with KolibriSensor TM

Introduction to Scanning Probe Microscopy

Chapter 12. Nanometrology. Oxford University Press All rights reserved.

AFM Imaging In Liquids. W. Travis Johnson PhD Agilent Technologies Nanomeasurements Division

2.76/2.760 Multiscale Systems Design & Manufacturing

Improving nano-scale imaging of of intergrated micro-raman/afm systems using negativestiffness

TECHNIQUE TO EVALUATE NANOMECHANICS OF CANTILEVER AT NANOSCALE BY USING AFM

Measurement of interfacial shear (friction) with an ultrahigh vacuum atomic force microscope

Supporting Information

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

INDIAN INSTITUTE OF TECHNOLOGY ROORKEE NPTEL NPTEL ONLINE CERTIFICATION COURSE. Biomedical Nanotechnology. Lec-05 Characterisation of Nanoparticles

Bridge between research in modern physics and entrepreneurship in nanotechnology. Quantum Physics

Atomic force microscopy study of polypropylene surfaces treated by UV and ozone exposure: modification of morphology and adhesion force

Thermally Activated Friction

Santosh Devasia Mechanical Eng. Dept., UW

2d-Laser Cantilever Anemometer

Accurate thickness measurement of graphene

Nanomechanics Measurements and Standards at NIST

Transcription:

The Atomic Force Microscope as a Critical Tool for Research in Nanotribology Rachel Cannara and Robert W. Carpick Nanomechanics Laboratory, University of Wisconsin Madison Department of Engineering Physics, Madison, WI 53706 www.rhk-tech.com

The Atomic Force Microscope as a Critical Tool for Research in Nanotribology Introduction The atomic force microscope (AFM) is an invaluable tool for studying single-asperity contacts and their structural and tribological properties, including friction, adhesion, wear, and topography 1. We use an RHK Technology variable-temperature (VT), ultra-high vacuum AFM (UHV350 AFM/STM) with SPM100 and AFM100 electronics to characterize micro- and nano-scale interfaces in controlled or UHV environments (base pressure < 10-10 mbar). The unique beetle -type 2 design of this AFM exhibits low thermal drift, making it possible to image pristine surfaces (vacuum-cleaved or annealed/prepared in situ) with a high level of mechanical stability. We regularly obtain low-noise, atomic lattice resolution images (in contact mode) for a variety of materials. Figure 2 shows room temperature deflection and stickslip images of the NaCl (100) surface, cleaved in situ at < 10-10 mbar. The slope-shaded topographical image shows steps and terraces, as well as a screw dislocation (top right region). A smaller, 10nm scan on a terrace reveals the NaCl lattice. load is critical for developing a complete understanding of the physics and tribological properties at sliding interfaces. In the sections below, we describe our basic procedure to obtain and interpret friction versus load data using the RHK system. Figure 1: Schematic diagram of an atomic force microscope with optical beam deflection detection of cantilever deformation due to normal and lateral forces on the tip. A large portion of our most recent work relies on the VT capability of the UHV350. At elevated temperatures, we have observed the NaCl surface undergo remarkable topographical changes, including the creation and motion of dislocations. Figure 3 shows images that illustrate this behavior, which is enhanced in the lateral force image. In addition, we have achieved stick-slip friction at low temperatures. While some thermal drift occurs in an image (see Figure 4 on next page), the stick-slip behavior persists, and it is possible to correct for the small amount of distortion due to drift. With little known about the processes that govern stick-slip at the atomic scale, the UHV350 enables us to study this phenomenon with tremendous flexibility and control over experimental conditions. Scan Direction Figure 2: 2x2 μm 2 deflection (left) and 10x10 nm 2 friction trace (right) showing stick-slip behavior with periodicity equal to the lattice constant of NaCl (5.65 Å); raw data is shown without filtering. Figure 3: 2x2 μm 2 topography (left) and lateral force (right) images, revealing screw dislocations at 450 K. In addition to stick-slip behavior, measuring and interpreting friction as a function of applied 2

Selecting an Appropriate Cantilever and Probe For friction measurements, we typically purchase commercially-available, contact mode (~10-20 khz flexural resonance frequency) cantilevers with integrated tips composed of either bare silicon or silicon nitride, or coated with a second material chosen based on specific properties, Scan Direction Figure 4: Lateral force image and line trace at 128 K. such as hardness or conductivity. In some experiments (e.g., to measure the lateral deflection sensitivity from lateral force-distance curves), we glue colloidal probes to the tip end of a commercial cantilever. In addition, we coat tips with amorphous carbon coatings of different thicknesses using the 100-200 kv electron beam in a transmission electron microscope (TEM). Figure 5: TEM micrographs of a tungsten carbide-coated Si AFM tip before (left) and after (right) scanning on a Si surface show how contamination and tip erosion can occur. TEM is ideal for measuring the dimensions and tip shape of each cantilever, as well. normal and torsional spring constants are easily characterized with the flexural and torsional Sader methods 3-4,eliminating a large source of error that results from using nominal manufacturer values. Optical microscopy is sufficient for measuring the length and width of a cantilever and the distance of the tip to the free end of the lever (at x10 and x40 magnification). Using TEM, we determine the cantilever thickness, as well as the height and position of the tip (making certain that it is centered along the width of the lever), its radius at the apex, and its structure (i.e., whether it is amorphous or crystalline). Figure 5. TEM micrographs of a tungsten carbide-coated Si AFM tip before (left) and after (right) scanning on a Si surface show how contamination and tip erosion can occur. In general, a tip is chosen based on its shape and material properties, and we perform TEM before and after an experiment to record how much a tip may have changed. It is very common for tip erosion to occur during sliding. Figure 5 shows an example of an AFM tip that has been contaminated and worn by scanning. It is crucial to use TEM or some other tip characterization method (e.g., an image-tip reconstruction algorithm) to track variations in tip shape. Aligning the Laser and Centering the PSD Compliant cantilevers are preferred for their increased sensitivity to lateral forces relative to stiffer levers. Accordingly, it is important to align the laser as close to the free end of the cantilever as possible. It is also critical to center the laser spot on the four-quadrant photosensitive detector (PSD) both to minimize uncertainty in an experiment and to avoid truncating the laser spot at the edge of the photodetector. Figures 6a and 6b (on next page) show the optical arrangement and the dependence of (lateral) deflection sensitivity, or change in signal per change in displacement, on the position of the laser spot with respect to the center of the PSD. In general, both the normal and lateral deflection sensitivity decreases with increasing PSD offset (e.g., as it moves from position 1 to 3 in Figure 6a). This occurs as a result of the non-uniform intensity distribution of lasers, regardless of truncation. 5 Figure 7 (on page 5) helps illustrate this effect schematically with a cantilever undergoing a (small) sinusoidal oscillation about its long axis. The output response depends on the laser spot position on the PSD. Thus, while the lateral signal output for the laser spot at position 1 represents the true 3

(a) (b) Figure 6: (a) Arrangement of cantilever, focused laser beam and photo-sensitive detector (PSD) in an atomic force microscope (AFM) (beam waist drawn to scale relative to PSD); the initial laser spot position may be offset from the center of the PSD, indicated by positions 1, 2 and 3. (b) Lateral deflection sensitivity versus PSD offset signal and displacement with positions 1, 2 and 3 indicated; data were obtained from the slope of the contact region in a lateral force versus distance curve for a colloidal probe against a rigid, vertical surface. 5 mechanical behavior of the cantilever, a lateral offset of the laser spot relative to the center of the PSD (positions 2 and 3) yields a distorted response. Unlike other commercial UHV AFMs, the PSD in the UHV350 may be adjusted both vertically and horizontally with internal stepper motors. This feature permits us to make fine alignments to the position of the reflected beam relative to the center of the PSD, thereby maximizing detection sensitivity and minimizing measurement uncertainty in an experiment. Force-Distance Curves and Ramping Applied Load With the point spectroscopy mode in the software, we take normal force-versusdistance curves to measure the pull-off force between the tip and surface and to establish the range of loads to investigate in a friction versus load study. There are several ways to ramp the load in an experiment: (1) by varying the setpoint with the feedback on, (2) by changing the z-displacement, or (3) by modulating the setpoint with the feedback gains near zero. The best approach depends on the scan size and surface properties (e.g., rms roughness, chemical inhomogeneity, etc.) Greater inhomogeneity or topographical variation calls for feedback control. For stick-slip measurements, we minimize the gains or disable the feedback loop entirely, because cantilever torsion is accompanied by small but physical changes in the normal signal which can induce a feedback response that interferes with the measurement. The image spectroscopy mode controls the setpoint or z-voltage ramp during images. The geometry of every AFM requires that the cantilever be tilted by some angle relative to the sample. In the RHK AFM, this angle is 22.5. Cantilever tilt produces different effects depending on the type of measurement, such as in-plane contributions to damping in intermittent contact mode AFM. 6 Similarly, for contact mode measurements, including friction versus load and force-distance measurements, this tilt causes the relative position of the tip and surface to change depending on the applied load. Consequently, when a surface is chemically or topographically inhomogeneous, or if different load measurements must be recorded on the same scan line, it is necessary to use cantilever tilt compensation. 7 While other systems require external control to achieve compensation, it is accomplished quite easily 4

with the RHK AFM by selecting an asymmetric image size in the software (where the y-scan size can be greater than the x-size) or with the electronics (separate vs. ganged x and y range switch on the SPM100). Analyzing Friction Versus Load Data Friction is half of the difference between the lateral signal in the trace and retrace directions. In the RHK software, we use the difference option in image processing to subtract the trace and retrace images and then plot the line-by-line average (e.g., software y-average option) of the difference versus the line-by-line average of the deflection signal. This ability to analyze data in real time helps expedite the process of measurement and to make informed decisions about the direction to take in an experiment. Later, we employ a combination of several calibration schemes to convert normal and lateral signals to nano-scale forces with optimal accuracy and precision. The data can then be compared and contrasted with other data or fit to a contact mechanics model. The shape of a friction versus load curve depends on multiple factors: the geometry of the contact (e.g., sphere on flat, flat on flat, etc.); the contact mechanics (elasticity and deformation); and the shear strength, which results from chemical interactions (making and breaking bonds) and can exhibit a separate load dependence. Several well-established models exist which describe single-asperity contact mechanics (or, more specifically, how contact area depends on load). The most well-known of these models are the Derjaguin-Muller-Toporov (DMT) model 8,the Johnson-Kendall-Roberts (JKR) model 9, and an approach that combines DMT and JKR into a single transition model. 10-11 Figure 7: Schematic representation of the cantilever undergoing a torsional, sinusoidal oscillation at different lateral offsets of the laser spot relative to the PSD. The lateral signal (A1+B1-A2-B2) output from the PSD depends on laser spot position. If it is offset from the center of the PSD, the output signal will be distorted from the sinusoidal signal that represents the true mechanical behavior. Calibrating Forces To calibrate normal and lateral spring constants, we use the Sader methods mentioned above. The normal force calibration factor is the normal spring constant divided by the magnitude of the slope of the repulsive region in a normal force distance curve taken on a hard surface. There are several lateral calibration methods discussed in the literature; however, Ogletree s variable-load wedge method 12 is the most widely accepted approach. If this wedge method is not possible or if the probe cannot be scanned on a calibration surface, the lateral force calibration may be obtained in a fashion similar to normal force calibration. Lateral force-distance measurements with a colloidal probe against the vertical edge of a GaAS sample (Figure 8) can be used to calculate the lateral deflection sensitivity in an experiment. 5 Regardless of the normal or lateral force calibration method, the laser must be centered on the photodetector to optimize precision. An offset of the spot from the center of the PSD leads to increased measurement uncertainty, as 5

shown in Figure 9. Lateral calibration is a crucial step in friction force microscopy in which the best results can be compared quantitatively with other work. Choosing both the appropriate calibration method and an AFM with the most control over tip-sample geometry and detector alignment produces the most robust measurements. Conclusion Until recently, tribology has remained a mere phenomenology, having lacked the tools that are necessary for studying single-asperity contacts. In the last decade or so, the AFM has enabled scientists to peer into the atomic regime and begin to uncover the fundamental mechanisms of frictional energy dissipation. To explore the contribution of each mechanism, we need controlled environments, thermal and mechanical stability, and the ability to take accurate and precise measurements. The RHK design makes all of this possible. Figure 8: Lateral force-distance curve for a colloidal probe against a vertically-oriented (110)plane of a GaAs crystal. Figure 9: The lateral force calibration factor versus lateral PSD offset in volts (out of ~6V) and microns (where the width of each PSD sector is 1.3 mm). Dashed line is a parabolic curve fit. The absolute uncertainty is a percentage of the calibration value and, therefore, increases with increasing displacement of the laser spot relative to the center of the PSD. References 1. Carpick, R.W. and M. Salmeron, Chem. Rev. 97, 1163-94 (1997). 2. Meyer, G., Rev. Sci. Instrum. 67, 2960-5 (1996). 3. Sader, J.E., Rev. Sci. Instrum. 70, 3967-9 (1999); 4. Green, C.P., H. Lioe, J.P. Cleveland, R. Proksch, P. Mulvaney, and J.E. Sader, Rev. Sci. Instrum. 75, 1988-96 (2004); 5. Cannara, R.J. M. Eglin (2006) 6. Cannara, R.J., M. Eglin and R.W. Carpick, Lateral force calibration in atomic force microscopy II: The effect of laser offset and guidelines for optimization, Rev. Sci. Instr. (2006) 7. Carpick, R.W. and M.A. Eriksson, MRS Bulletin 29, 472 (2004). 8. Cannara, R.J., M.J. Brukman, and R.W. Carpick, Rev. Sci. Instrum. 76, 053706 (2005). 9. Derjaguin, B.V., V.M. Muller, and Y.P. Toporov, J. Coll. Interf. Sci. 53, 314-26 (1975). 10. Johnson, K.L., K. Kendall, and A.D. Roberts, Proc. Roy. Soc. Lond. A 324, 301-13 (1971). 11. Carpick, R.W., D.F. Ogletree, and M. Salmeron, J. Coll. Interf. Sci. 211, 395-400 (1999). 12. Grierson, D.S., E.E. Flater, and R.W. Carpick, J. Adh. Sci. Tech. 19, 291-311 (2005). 13. Ogletree, D.F., R.W. Carpick, and M. Salmeron, Rev. Sci. Instrum. 67, 3298-306 (1996). RHK Technology, Inc. 1050 East Maple Road, Troy, MI 48083 248-577-5426 www.rhk-tech.com info@rhktech.com 6