NEEL Phase Change in Chromium At the Néel Temperature

Similar documents
HALL. Semiconductor Resistance, Band Gap, and Hall Effect

Temperature Measurements

Studying Phase Transitions with a Strain Gage

Lab E3: The Wheatstone Bridge

Temperature Measurements

Exploring Phase Transitions in Chromium

Sensing, Computing, Actuating

Experiment 3. Electrical Energy. Calculate the electrical power dissipated in a resistor.

Strain Gauge Application and Measurement of Unknown Load

EM375 MECHANICAL ENGINEERING EXPERIMENTATION THERMOCOUPLE LABORATORY

UMEÅ UNIVERSITY Department of Physics Agnieszka Iwasiewicz Leif Hassmyr Ludvig Edman SOLID STATE PHYSICS HALL EFFECT

ME 365 EXPERIMENT 5 FIRST ORDER SYSTEM IDENTIFICATION APPLIED TO TEMPERATURE MEASUREMENT SYSTEMS

DUBLIN INSTITUTE OF TECHNOLOGY Kevin Street, Dublin 8.

Temperature Measurement

The Underground Experimental Investigation of Thermocouples

Veerapong Kanchanawongkul*

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

Laboratory 12: Three Thermodynamics Experiments

ADVANCED UNDERGRADUATE LABORATORY EXPERIMENT 20. Semiconductor Resistance, Band Gap, and Hall Effect

EXPERIMENT VARIATION OF THERMO-EMF WITH TEMPERATURE. Structure. 7.1 Introduction Objectives

Critical parameters of

Thermocouple Calibrations and Heat Transfer Coefficients

EXPERIMENT 9 Superconductivity & Ohm s Law

1. Mark the correct statement(s)

Mechatronics II Laboratory EXPERIMENT #1: FORCE AND TORQUE SENSORS DC Motor Characteristics Dynamometer, Part I

Sensors and Actuators Sensors Physics

Temperature Measurement

ASEN 2002 Experimental Laboratory 1: Temperature Measurement and an Blow Dryer Test

Exercise 1: Thermocouple Characteristics

Using a Mercury itc with thermocouples

The Digital Multimeter (DMM)

Measurements & Instrumentation. Module 3: Temperature Sensors

Determination of freezing points of pure substances with Cobra4 TEC

Lecture 11 Temperature Sensing. ECE 5900/6900 Fundamentals of Sensor Design

Fig. 1. Two common types of van der Pauw samples: clover leaf and square. Each sample has four symmetrical electrical contacts.

The Strain Gauge. James K Beard, Ph.D. Rowan Hall Auditorium November 2, 2006

Mechatronics II Laboratory EXPERIMENT #1 MOTOR CHARACTERISTICS FORCE/TORQUE SENSORS AND DYNAMOMETER PART 1

INDIANA DEPARTMENT OF TRANSPORTATION OFFICE OF MATERIALS MANAGEMENT. VERIFYING THERMOMETERS ITM No T

2.8-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Dew Formation

SENSORS and TRANSDUCERS

HTC High T C Superconductors

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

15. Compare the result with the value you have taken above Compare the calculated pressure value with the actual pressure value that you have

Force and Displacement Measurement

Sensors and Actuators Sensors Physics

Cryogenic Instrumentation I Thermometry OUTLINE Thermometry Pt (pure metal) Temperature Ranges of Thermometer Application Typical Resistive Thermal

PHYSICS EXPERIMENTS 133. P (x 0,y 0 )

I. MEASUREMENT OF TEMPERATURE

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

UNIT II CURRENT ELECTRICITY

I m. R s. Digital. R x. OhmmetersxSeries Shunt Digital. R m

Measurement in Engineering

Temperature Sensors & Measurement

SENSORS AND TRANSDUCERS

Current and Resistance

DC Circuits Analysis

Sensors, Signals and Noise 1 COURSE OUTLINE. Introduction Signals and Noise Filtering Sensors: Strain Gauges. Signal Recovery, 2017/2018 Strain Gauges

Process Control Instrumentation Technology Curtis D. Johnson Eighth Edition

Sensing, Computing, Actuating

Temperature measurement

Experiment A4 Sensor Calibration Procedure

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol

Resistance Learning Outcomes

Simple Battery. Alessandro Volta ( ) A replica of the first battery, built by Volta, can be created and used to understand electricity.

Good practice guide containing experimental results and recommendations for the selection, preparation and calibration of the temperature sensors

However, in matter, magnetic induction depends on magnetization M in the following way:

Lecture 5: Using electronics to make measurements

HEL. Helicons in Metals

Resistance Learning Outcomes. Resistance Learning Outcomes. Resistance

Newton s Second Law of Motion

Measurement of non-electrical quantities

Electromotive Force. The electromotive force (emf), ε, of a battery is the maximum possible voltage that the battery can provide between its terminals

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Superconductivity. Never store liquid nitrogen in a container with a tight fitting lid.

5. TEMPERATURE AND HEAT

Thermoelectric effect

Strain Measurement MEASUREMENT EXPERIMENT

Thermometry. History. History 1/21/18. The art or science of temperature observation

Lab 5a: Magnetic Levitation (Week 1)

Experiment 2-5. Wheatstone Bridge experiment

PHYS 2212L - Principles of Physics Laboratory II

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

EXPERIMENT 11 LINEAR EXPANSION OF A SOLID MATERIAL

An investigation of the relationship between internal pressure and degree of carbonation of soda drinks

Understanding Integrated Circuit Package Power Capabilities

Resistivity and Temperature Coefficients (at 20 C)

Voltaic Cells. 100 ml graduated cylinder Emery cloth 150 ml beakers, 3 Salt bridge Voltmeter Wires with alligator clips, 2

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

ECNG3032 Control and Instrumentation I

The design and operational theory of ph electrodes is a very complex subject, explored only briefly here. What is important to understand is that thes

The Speed of Sound in Air

Part 2. Sensor and Transducer Instrument Selection Criteria (3 Hour)

THERMOCOUPLE CHARACTERISTICS TRAINER

Lab: Phase Change. Introduction. Predict. Computer setup- Equipment setup- Name: Period: Date:

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

KCSE PHYSICS PAPER SECTION A (25 marks) Answer all the questions in this section in the spaces provided.

Semiconductor thermogenerator

REVISED HIGHER PHYSICS REVISION BOOKLET ELECTRONS AND ENERGY

Physics 248, Spring 2009 Lab 9: Franck-Hertz Experiment

Chemistry 213. Electrochemistry

Transcription:

University of Toronto ADVANCED PHYSICS LABOATOY NEEL Phase Change in Chromium At the Néel Temperature evisions: January 2018: January/August 2016: October 2005: Original: Young-June Kim David Bailey <dbailey@physics.utoronto.ca> Jason Harlow John Pitre Copyright 2018 University of Toronto This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported License. (http://creativecommons.org/licenses/by-nc-sa/4.0/)

INTODUCTION Many solids undergo structural transformation as the temperature is changed. These are analogous to phase changes from gas to liquid or from liquid to solid except that in a structural transformation both phases are solid. Some of these transformations result from the onset of magnetic order in the solid, for example the ordering of atomic magnetic moments which occurs at the Curie temperature of a ferromagnet. Chromium is unique among metals in that the magnetic transition is from a paramagnetic (high temperature) phase to an anti-ferromagnetic 1 (low temperature) phase, at the Néel temperature, T N ~37.5 C. Also, the transformation is thermodynamically of the first order, which means that there is a latent heat (L=ΔQ) and a volume change (ΔV) at T N. Most magnetic transitions are second order, with a change in the specific heat (dq/dt) and the thermal expansion (dv/dt) at the transition temperature. The magnetic transition in Chromium is more easily detected by the volume change, ΔV, than by the small changes in the magnetic properties which occur when the metal becomes antiferromagnetic. In this experiment we measure the fractional length change, ( Δ / ), which is related to the volume change by ΔV V = 3 Δ We can calculate the latent heat per unit volume of the transition, L/V, using the Clausius- Clapeyron equation 2, dp dt N L L / V = = (2) T DV T ( DV / V ) and the fact that the Néel temperature is depressed by pressure and the rate of N dt N = 5.1K/kilobar (3) dp As can be seen in the short article by Matsumoto and Mitsui, Chromium undergoes a contraction when it passes from the antiferromagnetic phase to the paramagnetic phase (Matsumoto and Mitsui Figure 1) and also the coefficient of thermal expansion is larger in the paramagnetic phase than it is in the antiferromagnetic phase (Matsumoto and Mitsui Figure 2). EXPEIMENT A semiconductor strain gauge ( gauge rhymes with page ) has been glued to the Chromium sample and immersed in a Silicon oil bath for temperature stability. A copperconstantan thermocouple 3 is also held in place quite close to the sample, as shown in Figure 1. Preliminary temperature measurements may be done with a digital external thermometer dipped in the oil to give a rough indication of temperature. N (1) 1 Introduction to Solid State Physics by Charles Kittel (8th edition 2004 by John Wiley & Sons) Chapter 15, subsection on Antiferromagnetic Order 2 Heat and Thermodynamics by Mark Zemansky and ichard Dittman (7 th edition 1996 by McGraw-Hill) Chapter 11, sub-section on Clapeyron equation 3 Type T Cu versus Cu-Ni Alloy Thermocouples Data Tables, available on reserve in MP250 2

Safety eminders To avoid burns, do not touch the hot plate surface when it is on, or until it has cooled down after being turned off. Silicon oil is slippery and is very hard to wash out of your clothes. Clean up any spills promptly with paper towels. NOTE: This is not a complete list of all hazards; we cannot warn against every possible dangerous stupidity, e.g. opening plugged-in electrical equipment, juggling cryostats,. Experimenters must constantly use common sense to assess and avoid risks, e.g. if you spill liquid on the floor it will become slippery, sharp edges may cut you,. If you are unsure whether something is safe, ask the supervising professor, the lab technologist, or the lab coordinator. If an accident or incident happens, you must let us know. More safety information is available at http://www.ehs.utoronto.ca/resources.htm. to Wheatstone bridge oil to ice bath and Temperature voltmeter Strain Gauge Chromium Sample Copper Base Thermocouple Figure 1: Arrangement of the Chromium Sample, Strain Gauge and Thermocouple in the Silicon oil bath. The Strain gauge is glued to the top of the Chromium Sample. The Chromium Sample sits on the Copper Base. The entire apparatus is immersed in the oil bath in a glass beaker. As the bath temperature is raised, the output of a Wheatstone bridge is plotted versus temperature, and the appearance and approximate magnitude of the singularity due to Δ / at T N is noted. After preliminary setup runs have been performed a final run should be made with decreasing temperature and with the bath wrapped in cloth to ensure that the temperature decreases very slowly. 3

The Strain Gauge This information on the BCM BCM semiconductor strain gauge is taken from the manufacturer specification 4 BCM Gauge Type Number Doping of semiconductor Effective length at zero strain esistance at 23 C Temperature Coefficient of esistance SN5-120-P-1 / SN-120-5-P p-type 5 mm 120 ± 5% Ω <0.15%/ C Gauge Factor at 23 C 110 ± 5% Temperature Coefficient of Gauge Factor <0.15%/ C The gauge factor relates strain to fractional change in resistance, and is defined as F = Δ / Δ / In fact the gauge factor depends on temperature, and is given by F = F 0 + m F (T T 0 ) (5) where T 0 =21 C. Similarly, the total resistance of the gauge at zero strain was measured to have a slight dependence on temperature, so that the total resistance is given by: = 0 + m (T T 0 ) (6) Measuring the Coefficient of Thermal Expansion Since the gauge expands as the chromium expands, the strain we measure is due to the difference in the coefficients of thermal expansion of chromium and the silicon from which the gauge is made. The measurement of the strain is obtained from the change in the resistance as the temperature rises but the resistance of the gauge itself is a function of temperature so this effect must be considered as well. In fact the gauge was chosen to have a negative gauge factor so that effects of thermal expansion would be somewhat compensated for by changes in resistance due to rise in temperature. Strain is defined as Δ /. The apparent strain we measure over a change in temperature, ΔT, which does not include a phase change, is Δ / ΔT = α Cr α Si + m 0 F where the coefficient of thermal expansion of the Silicon strain gauge is α Si =2.52 10 6 C 1, and α Cr is to be determined. Note that in Chromium the coefficient of thermal expansion above the Néel Temperature may be different than that below. Temperature Measurement: Ni-Cu Thermocouple The thermocouple applies the Seebeck effect, which is the production of a small voltage across the length of a wire due to a difference in temperature along that wire. This effect is most easily observed and applied with a junction of two dissimilar metals in contact, each metal (4) (7) 4 https://www.bcmsensor.com/wp-content/uploads/2015/09/semiconductor_strain_gauges.pdf 4

producing a different Seebeck voltage along its length, which translates to a voltage between the two unjoined wire ends, as shown in Figure 2. T Figure 2: A single junction of two different metals (Nickel and Copper), which produces a small voltage between the free ends. This voltage increases with the temperature of the junction, T. The problem with this effect is that it is impossible to measure for a single junction. Once you attach a voltmeter to the free ends, you will always create another junction of dissimilar metals. For example, if your voltmeter uses copper leads, there will be a new Nickel-Copper junction which will also produce a voltage. For this reason, a thermocouple is always composed of two junctions, and only temperature differences can be measured, not absolute temperature. Figure 3 shows the setup used in this experiment, where T 1 is the temperature of an ice-water bath, and T 2 is the temperature of the oil in the beaker that contains the Chromium sample. T 1 Ni Cu Cu T 2 Ni Cu V Figure 3: Two junctions combined in a circuit with a voltmeter. T 1 is a reference temperature, T 2 is the temperature we wish to measure. The measured voltage is proportional to the difference T 2 T 1. The voltage produced by the thermocouple is on the order of a milli-volt. To measure this with the computer, it is first amplified by the high impedance voltmeter. You must calibrate the output of the voltmeter by comparing it to the reading on the dial, and perhaps adjusting the isolated output and zero dials on the voltmeter. You may assume that the dial is calibrated properly. Strain Gauge esistance Measurement: The Wheatstone Bridge There are several acceptable arrangements of the Wheatstone Bridge which can produce usable results for measurement of strain gauge resistance. The suggested arrangement shown in Figure 4 was designed to give maximum sensitivity to departures from equilibrium. 5

V 1 2 1.5 V v SG Figure 4: Wheatstone Bridge When 1 = 10 2, and V = 10 SG, the voltage across the bridge read by the voltmeter will read zero. Small changes in SG due to strain will lead to easily measureable voltages across the bridge. In this particular system, the two fixed resistances are 1 =1000 Ω and 2 =100 Ω, the resistance of the strain gauge is approximately SG 120 Ω, so variable decadal resistor should be set to approximately V 1200 Ω. To aid in calibration of the system, it may be noted that a change of 1 Ω in the variable resistor, V, causes a voltage change from equilibrium which is almost identical in magnitude to a change of 0.1 Ω in the strain gauge. Finally, the condition that the power dissipated in the strain gauge (6 mw) is less than 20 mw is fulfilled with this setup. The voltage you wish to measure is on the order of milli-volts, and should first be amplified by the milli-microvoltmeter. You should check the output is calibrated properly, so that the computer readings match that of the dial on the milli-microvoltmeter. In this experiment, the computer is being used as a two-channel volt-meter. The first channel voltage, which is related to the strain gauge resistance, is plotted on the y-axis. The second channel voltage, which is related to the temperature difference of the two ends of the thermocouple, is plotted on the x-axis. Data may be printed directly or saved in text format and read into an analysis program, such as Excel. Measurements to be Made The following points could be considered in presenting and discussing your experimental data: The magnitude of Δ / at T N should be determined with as high accuracy as possible, since this is the main purpose of the experiment. 6

The sign of Δ / should be shown to be consistent with the sign of dt N /dp and a positive latent heat, L, in going from the low temperature antiferromagnetic phase to the high temperature paramagnetic phase. Evaluate L from equation ΔV V = 3 Δ (1). Determine T N. Determine the width of the transition by changing the temperature very slowly through T N. Use equation Δ / ΔT = α α + m Cr Si to evaluate the coefficient of thermal 0 F expansion of Chromium, α Cr, both above and below the Néel temperature. Is there thermal hysteresis 5 in the system? For example, does a plot of D! /! versus temperature depend on whether the temperature is rising or falling? BIBLIOGAPHY T. Matsumoto and T. Mitsui, Thermal Expansion of Chromium Single Crystals at the Néel Temperature, Journal of the Physical Society of Japan, 27 (1969) 786; http://dx.doi.org.myaccess.library.utoronto.ca/10.1143/jpsj.27.786. 5 I. S. Williams and. Street, Investigation of thermal hysteresis near the Neel transition in chromium, Journal of Physics F: Metal Physics 10 (1980) 2551-2553; http://iopscience.iop.org/article/10.1088/0305-4608/10/11/026/pdf 7