The fast light of CsI(Na) crystals

Similar documents
Inorganic Scintillators

Chapter 4 Scintillation Detectors

The NaI:Tl and CsI:Tl crystals for effective detection of X-rays and low energy charged particles

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

DETECTORS. I. Charged Particle Detectors

Gamma Spectroscopy. References: Objectives:

Scintillators General Characteristics

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

SCINTILLATION DETECTORS AND PM TUBES

OPPORTUNITY TO JOIN IEEE AND NPSS

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Precision Crystal Calorimetry in High Energy Physics

Introduction to scintillators

Simulation of 4π HPGe Compton-Suppression spectrometer

Radioactivity and Ionizing Radiation

INORGANIC crystal scintillators are widely used in high

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Quality Assurance. Purity control. Polycrystalline Ingots

arxiv: v1 [physics.ins-det] 3 Feb 2011

Test of CsI (Tl) crystals for the dark matter search

arxiv: v1 [physics.ins-det] 29 Jun 2011

Study of absorption and re-emission processes in a ternary liquid scintillation system *

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

The Mössbauer Effect

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

A new scintillator detector for nuclear physics experiments: the CLYC scintillator

Characterization of the new scintillator Cs 2 LiYCl 6 :Ce 3+ *

XMASS: a large single-phase liquid-xenon detector

Week 6: Ch. 8 Scintillation Counters

05 - Scintillation detectors

Scintillation Detector

III. Energy Deposition in the Detector and Spectrum Formation

Scintillation Detectors

Performance study of the ceramic THGEM *

Analysis of γ spectrum

arxiv: v1 [physics.ins-det] 27 Feb 2014

arxiv: v2 [physics.ins-det] 28 Jul 2010

Gamma and X-Ray Detection

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

LSO/LYSO Crystal Development Ren-yuan Zhu

Precision Crystal Calorimetry in High Energy Physics: Past, Present and Future

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Studies of Hadron Calorimeter

Measurements of liquid xenon s response to low-energy particle interactions

New Scintillators for the Border Monitoring Equipment

The 46g BGO bolometer

Waveform Analysis for DM-Ice17. Zachary Pierpoint University of Wisconsin - Madison October 21, 2013 Yale Weak Interactions Discussions Group

PHYS 3446 Lecture #12

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

Scintillators 1. YEAR, I. CYCLE. AUTHOR: BPhys. Manja Ščetinec ADVISOR/MENTOR: Prof. Boštjan Golob

Detectors for the COHERENT neutrino experiment R. Tayloe Indiana U. for the COHERENT collaboration

Large Size LYSO Crystals for Future High Energy Physics Experiments

arxiv: v2 [physics.ins-det] 12 Feb 2014

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

2.5 Physics of the Universe, Astrophysics, Nuclear Planetology Dark Matter and Double Beta Decay Study Planetary Nuclear

Calibration and Monitoring for Crystal Calorimetry

Energy Resolution of Scintillation Detectors New Observations

arxiv:hep-ex/ May 2000

Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

Platinum resistance. also wirewound versions. eg

Study of pure CsI crystal coupling with APD. The University of Tokyo. Yi-Fan JIN

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

Test of CsI(Tl) crystals for the Dark Matter Search

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

arxiv: v2 [physics.ins-det] 8 Feb 2013

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Supporting Information

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Optically-Pumped Ge-on-Si Gain Media: Lasing and Broader Impact

Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay

Scintillation Detectors

Radiation (Particle) Detection and Measurement

Calibration of the BABAR CsI (Tl) calorimeter

Radionuclide Imaging MII Detection of Nuclear Emission

Enhanced α-γ Discrimination in Co-doped LaBr 3 :Ce

Unit 2. Instrumentation. Experts Teaching from Practical Experience

CsI(Tl) for WIMP dark matter searches

Detection and measurement of gamma-radiation by gammaspectroscopy

Lecture # 3. Muhammad Irfan Asghar National Centre for Physics. First School on LHC physics

Characterization of the Lanthanum Chloride Scintillation Detector

Researchers at the University of Missouri-Columbia have designed a triple crystal

Advantages / Disadvantages of semiconductor detectors

TIME-RESOLVED LUMINESCENCE SPECTRA IN COLORLESS ANATASE TiO 2 SINGLE CRYSTAL

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Radiation Detection and Measurement

arxiv: v1 [physics.ins-det] 27 Sep 2018

GAMMA RAY SPECTROSCOPY

EEE4106Z Radiation Interactions & Detection

Chinese Physics C. Study of n-γ discrimination in low energy range (above 40. kevee) by charge comparison method with a BC501A liquid

Scintillation Detectors Particle Detection via Luminescence. Kolanoski, Wermes

Crystals for the HHCAL Detector Concept Rihua Mao, Member, IEEE, Liyuan Zhang, Member, IEEE, and Ren-Yuan Zhu, Senior Member, IEEE

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

Status of the ANAIS experiment at Canfranc

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Transcription:

CPC (HEP & NP), 2011, xx(x): 1-5 Chinese Physics C Vol. xx, No. X, Xxx, 2011 The fast light of CsI(Na) crystals Xilei Sun 1;1) Junguang Lu 1 Tao Hu 1 Li Zhou 1 Jun Cao 1 Yifang Wang 1 Liang Zhan 1 Boxiang Yu 1 Xiao Cai 1 Jian Fang 1 Yuguang Xie 1 Zhenghua An 1 Zhigang Wang 1 Zhen Xue 1 Aiwu Zhang 1 Qiwen Lu 2 Feipeng Ning 1 Yongshuai Ge 1 Yingbiao Liu 1 1 Institute of High Energy Physics, CAS, Beijing 100049, China 2 Shanxi University, Taiyuan 030006, China Abstract The responds of different common alkali halide crystals to alpha-rays and gamma-rays are tested in this research. It is found that only CsI(Na) crystals have significantly different waveforms between alpha and gamma scintillations, while others have not this phenomena. It is suggested that the fast light of CsI(Na) crystals arises from the recombination of free electrons with self-trapped holes of the host crystal CsI. Self-absorption limits the emission of fast light of CsI(Tl) and NaI(Tl) crystals. Key words CsI(Na), Waveform, Ionization, Scintillation, Exciton, Self-absorption PACS 29.40.Mc 1 Introduction 2 Experimental set-up CsI(Na) crystals are important scintillators for electromagnetic calorimetry in experimental particle physics. According to catalogues of main scintillation crystals producers (Saint-Gobain, AMCRYS-H et al.), the decay time of γ-scintillations in CsI(Na) amounts to approximately 630 ns with the peak wavelength of 420 nm. In fact, our previous paper reveals that there are fast components hiding in the slow γ-scintillations of CsI(Na) crystals, and the proportion of that is larger responding to higher de/dx particles [1]. In this paper, we report the result of the testing of other common alkali halide crystals responding to alpha-rays and gamma-rays. The luminescence process of common alkali halide crystals is discussed in detail at the end of this paper. The schematic of the experimental set-up is illustrated in Fig. 1. Two R8778 PMTs are directly attached to the top and the bottom surfaces of the crystal. The PMT signals are sent to the oscilloscope and discriminators (NIM CAEN N840) via a fan-out module (NIM CAEN N625). The discriminator thresholds are set to be equivalent to 0.5 single photoelectrons, which are calibrated by a pulsed LED light source. The noises of PMT can then be effectively suppressed to 0.055 Hz, which is mainly caused by Cherenkov light, by the coincidence of the two discriminator signals with a width of 200 ns. The oscilloscope is a TDS3054C with a sampling frequency of 5 GS/s and a memory depth of 2 µs (10000 points, 0.2 ns/channel) for each of 4 channels. The high-speed sampling rate is a necessary condition for fast waveform analysis. Supported by Technological Innovation Project of Institute of High Energy Physics 1) E-mail: sunxl@ihep.ac.cn

No. X SUN Xi-Lei et al: The fast light of CsI(Na) crystals 2 The crystals tested in this study are CsI(Na), CsI(Tl), NaI(Tl) and pure CsI. The detail properties of them are listed in Table 1. Gamma-rays from a 0.5 micro-curie 137 Cs source and alpha-rays from a 5 micro-curie 239 Pu source are used to excite the crystals. Table. 1 The crystals tested in the research. Crystals CsI(Na) CsI(Tl) NaI(Tl) CsI Doping Na Tl Tl - Mole% ~ 0.02 ~ 0.2 ~ 0.2 - Size (cm) 2.5 2.5 2.5 Φ 2.5 2.5 2 2 2 Φ 2.5 2.5 the rise time is ~ 5 ns. The decay time of slow components of α-scintillations is shorter than that of γ-scintillations, which is ~ 490 ns. Here, the old surface is the surface layer of CsI(Na) crystals with sodium ions losing caused by the moisture absorption of sodium; the new surface is that of grinding off the old layer. Thallium-doped crystals do not have this Fig. 1. Experimental set-up for the test of the phenomenon. crystals. 3 Results and discussion The measured waveform profile histograms of γ-scintillations and α-scintillations from different crystals are shown respectively below. Here we chose waveforms of full energy deposition to build the histograms, which are 661.7 kev for gamma and 5.2 MeV for alpha. The values of the rise time are read from the amplification plots of the leading edge directly, and that of decay time are get from an exponential fitting of the trailing edge. 3.1 Waveforms of CsI(Na) (5.2 MeV) from CsI(Na) crystals are shown in Fig. 2. The waveforms of γ-scintillations have a rise time of ~ 40 ns and a decay time of ~ 670 ns. In comparison, the waveforms of α-scintillations with old or new surface have significant fast components. The decay time is only ~ 17 ns and Fig. 2 Waveform profile histograms from CsI(Na) α-scintillations of 5.2 MeV with old surface (c) α-scintillations of 5.2 MeV with new surface. 3.2 Waveforms of CsI(Tl) (5.2 MeV) from CsI(Tl) crystals are shown in Fig. 3. The rise time of α-scintillations is ~ 35 ns and the decay time is ~ 670 ns. There is not fast light. Similar, the waveforms of γ-scintillations have a rise time ~ 50 ns and a longer decay time ~ 1080 ns. Although the different decay time can be

No. X SUN Xi-Lei et al: The fast light of CsI(Na) crystals 3 used for alpha-gamma separation, but the performance is much less than CsI(Na) crystals by using the fast light. 3.4 Waveforms of pure CsI Finally, waveform profile histograms of (5.2 MeV) from pure CsI crystals are shown in Fig. 5. The rise time of α-scintillations is ~ 5 ns and the decay time is ~ 15 ns. Similar, the waveforms of γ-scintillations have a rise time ~ 5 ns and a decay time ~ 22 ns. Fig. 3 Waveform profile histograms from CsI(Tl) 3.3 Waveforms of NaI(Tl) (5.2 MeV) from NaI(Tl) crystals are shown in Fig. 4. The rise time of α-scintillations is ~ 10 ns and the decay time is ~ 170 ns. Similar, the waveforms of γ-scintillations have a rise time ~ 20 ns and a slightly longer decay time ~ 250 ns. It is difficult to separate alpha and gamma by the decay time. Fig. 5 Waveform profile histograms from pure CsI The summary of the measured waveform parameters are listed in Table 2. The present measurements of waveforms lead to two facts: (1) The fast light of CsI(Na) crystals can be significantly excited by alpha-rays, while which cannot be excited by gamma-rays. (2) The luminescence of gamma and alpha from the other common alkali halide crystals is not significantly different. It, thus, appears from these two facts that there are different aspects of the luminescence mechanisms between CsI(Na) crystals and CsI(Tl) or NaI(Tl) crystals. Fig. 4 Waveform profile histograms from NaI(Tl)

CPC (HEP & NP), 2011, xx(x): 1-5 Chinese Physics C Vol. xx, No. X, Xxx, 2011 Table. 2 Summary of waveform parameters. Crystals CsI(Na) CsI(Tl) NaI(Tl) CsI Source γ α γ α γ α γ α Rise time (ns) 40 5 50 35 20 10 5 5 Decay time (ns) 670 17 fast 1080 670 250 170 22 15 490 slow 3.5 Discussion The scintillation process in common alkali halide crystals has been discussed by Stephen E. Derenzo and Marvin J. Weber in reference [2], which can be described in several steps: i. Ionization Ionization occurs when the particles injected into the crystals, and the average energy needed to produce an electron-hole pair is about 20 ev for CsI and NaI crystals. ii. Relaxation of Electrons and Holes The electrons and the holes resulting from the ionization process form separated charge carriers that cause the surrounding atoms to rearrange themselves. In CsI and NaI crystals, the self-trapped hole takes the form of a so-called V k center, where two Iodine atoms share the hole by pulling together and forming a covalent bond. iii. Carrier Diffusion In CsI and NaI crystals, the valance bands are filled and an excess electron is spatially diffuse in an essentially empty conduction band. On the other hand, holes are generally localized and will only diffuse if thermal vibrations are able to move the hole from one trapping site to another. iv. Formation of different excitons A diffuse electron may be trapped by an activator atom and then a self-trapped hole also be captured by it through thermal migration. The result is an activator-trapped-exciton. A diffuse electron may also be trapped immediately by a self-trapped hole resulting a self-trapped-exciton. The probability that a given electron will recombine with a self-trapped hole rather than suffer capture at activator atom site will be an increasing function of the density of self-trapped holes, hence, an increasing function of ionization density, while a decreasing function of concentration of activator atoms. v. Radiative Emission The de-excitation of two different kinds of excitons results two different scintillations. Thermal quenching is a common non-radiative process and occurs if thermal vibrations can deform exciton to ground state. Self-absorption is another constraint of scintillations if the emission band overlaps with the absorption band. Based on the above process, it is noted that the fast scintillations with decay time of about 20 ns and wavelength of about 310 nm from pure CsI or NaI crystals are dominated by self-trapped-excitons for both gamma and alpha particles. The fast light of α-scintillations from CsI(Na) crystals arises from self-trapped-excitons, while slow components of both alpha and gamma scintillations are dominated by activator-trapped-excitons. Fortunately, the absorption bands of CsI(Na) are all below 300 nm [3], thus, the fast light can be propagation through crystals. CsI(Tl) and NaI(Tl) crystals have the same mechanism of scintillation, while, a discrepancy is that the emission bands of fast light overlaps with the absorption bands [4] [5], hence, the fast light of high ionization density particles cannot be significantly observed. UV self-absorption of CsI(Tl) and NaI(Tl) crystals may be due to the presence of Tl atom, which can be excited by the UV light. The transmittance of different crystals measured by a DH-2000-BAL Deuterium-Halogen Light Source and a QE65000 Scientific-grade Spectrometer is

No. X SUN Xi-Lei et al: The fast light of CsI(Na) crystals 5 shown in Fig. 6. It can clearly be seen that the light of wavelength less than 320nm is strongly absorbed for CsI(Tl) crystals. The decay length of 310nm light is ~ 33 cm for CsI(Na) crystals according to the measurements. 6 References [1] arxiv:1102.2727v1 [physics.ins-det] [2] Stephen E. Derenzo and Marvin J. Weber. Nucl. Instr. and Meth. A, 1999, 422: 111-118 [3] Olive Lee Hsu. Phys. Rev. B, 1977, 15: 5821-5833 [4] R. Gwin and R. B. Murray. Phys. Rev, 1963, 131: 508-512 [5] Eiichi Matsui. J. Phys. Soc. Jpn, 1967, 22: 819-830 Fig. 6 Transmittance of different crystals. 4 Conclusions Different alkali halide crystals are tested, the fast components of α-scintillations only can be significantly found from CsI(Na) crystals. Self-absorption limits the emission of fast light from CsI(Tl) and NaI(Tl) crystals. Hence, CsI(Na) is the unique crystals among common alkali halide crystals, which can be used to doing particle identification by different kinds of luminescence mechanisms. The fast light of CsI(Na) crystals can be significantly excited by particles with high ionization density like alphas rather than electrons. As a result, the high de/dx particles can be easily distinguished from gamma-rays and electrons. Therefore, CsI(Na) crystals are suitable materials for neutron detection and dark matter detection. 5 Acknowledgments We are thankful to Liangjian Wen for his support.