Swanning about in Reciprocal Space. Kenneth, what is the wavevector?

Similar documents
Scattering Techniques and Geometries How to choose a beamline. Christopher J. Tassone

Data collection Strategy. Apurva Mehta

Diffractometer. Geometry Optics Detectors

SSRL XAS Beam Lines Soft X-ray

X-ray diffraction is a non-invasive method for determining many types of

Data Acquisition. What choices need to be made?

X-ray, Neutron and e-beam scattering

print first name print last name print student id grade

X-rays. X-ray Radiography - absorption is a function of Z and density. X-ray crystallography. X-ray spectrometry

Introduction to XAFS. Grant Bunker Associate Professor, Physics Illinois Institute of Technology. Revised 4/11/97

X-Ray Emission and Absorption

Anatomy of an XAFS Measurement

Setting The motor that rotates the sample about an axis normal to the diffraction plane is called (or ).

Röntgenpraktikum. M. Oehzelt. (based on the diploma thesis of T. Haber [1])

Diffraction: spreading of waves around obstacles (EM waves, matter, or sound) Interference: the interaction of waves

Basics of Synchrotron Radiation Beamlines and Detectors. Basics of synchrotron radiation X-ray optics as they apply to EXAFS experiments Detectors

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

DETECTORS. I. Charged Particle Detectors

Sample Alignment (2D detector) Part

EEE4106Z Radiation Interactions & Detection

X-Ray Photoelectron Spectroscopy (XPS)

X-ray Absorption Spectroscopy Eric Peterson 9/2/2010

Surface Sensitivity & Surface Specificity

On the use of Kumakhov Polycapillaries to improve laboratory

X-ray diffraction geometry

Determination of the high- pressure phases (II and IV ) ) of. techniques

High-Resolution Neutron Diffraction Monochromators for Neutron Diffractometry

Neutron Instruments I & II. Ken Andersen ESS Instruments Division

Good Diffraction Practice Webinar Series

An Introduction to Diffraction and Scattering. School of Chemistry The University of Sydney

4. Other diffraction techniques

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

AP5301/ Name the major parts of an optical microscope and state their functions.

Introduction to Triple Axis Neutron Spectroscopy

Atomic and nuclear physics

LAB 01 X-RAY EMISSION & ABSORPTION

Structure determination at high pressures: X-ray diffraction

Solid State Physics Lecture 3 Diffraction and the Reciprocal Lattice (Kittel Ch. 2)

SCINTILLATION DETECTORS AND PM TUBES

EXAFS. Extended X-ray Absorption Fine Structure

Synchrotron X-ray surface scattering techniques. Joanne E. Stubbs Center for Advanced Radiation Sources, GeoSoilEnviroCARS, University of Chicago

Muffin-tin potentials in EXAFS analysis

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Data Collection. Overview. Methods. Counter Methods. Crystal Quality with -Scans

Sample Alignment Part

Structure of Surfaces

Studying Metal to Insulator Transitions in Solids using Synchrotron Radiation-based Spectroscopies.

CHEM*3440. X-Ray Energies. Bremsstrahlung Radiation. X-ray Line Spectra. Chemical Instrumentation. X-Ray Spectroscopy. Topic 13

Surface Sensitive X-ray Scattering

Supporting Information

X Rays & Crystals. Characterizing Mineral Chemistry & Structure. J.D. Price

Gamma and X-Ray Detection

Structure Report for J. Reibenspies

Small-Angle X-ray Scattering (SAXS)/X-ray Absorption Near Edge Spectroscopy (XANES).

X-Ray Photoelectron Spectroscopy (XPS)

Chapter 1 X-ray Absorption Fine Structure (EXAFS)

Praktikum zur. Materialanalytik

A facility for Femtosecond Soft X-Ray Imaging on the Nanoscale

Changing and challenging times for service crystallography. Electronic Supplementary Information

Detekce a spektrometrie neutronů. neutron detection and spectroscopy

X-ray Data Collection. Bio5325 Spring 2006

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Atomic and nuclear physics

The Chemical Control of Superconductivity in Bi 2 Sr 2 (Ca 1 x Y x )Cu 2 O 8+±

General theory of diffraction

Neutron and x-ray spectroscopy

X-ray scattering methods for the analysis of advanced materials

Structural characterization. Part 1

Revision Guide. Chapter 7 Quantum Behaviour

Structural Characterization of Giant Magnetoresistance Multilayers with New Grazing Incidence X-ray Fluorescence

Radioactivity. Lecture 6 Detectors and Instrumentation

2D XRD Imaging by Projection-Type X-Ray Microscope

Calibration of the IXPE Instrument

Laser-Modulator System

Basics of XRD part III

Biophysics Collaborative Access Team Basic Techniques for EXAFS Revision date 6/25/94 G.Bunker. Optimizing X-ray Filters

COST MP0601 Short Wavelength Laboratory Sources

Detection and measurement of gamma-radiation by gammaspectroscopy

Understanding X-rays: The electromagnetic spectrum

INTRODUCTION TO THE APPLICATION AND LIMITS OF ANOMALOUS X-RAY DIFFRACTION IN THE DETERMINATION OF PARTIAL STRUCTURE FACTORS*

Laboratory Manual 1.0.6

Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

What use is Reciprocal Space? An Introduction

Semiconductor Detectors

Main Notation Used in This Book

EDS Mapping. Ian Harvey Fall Practical Electron Microscopy

Diffraction Gratings, Atomic Spectra. Prof. Shawhan (substituting for Prof. Hall) November 14, 2016

Silicon Drift Detectors: Understanding the Advantages for EDS Microanalysis. Patrick Camus, PhD Applications Scientist March 18, 2010

PHYS Introduction to Synchrotron Radiation

Atomic Motion via Inelastic X-Ray Scattering

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Design of multilayer X-ray mirrors and systems

ANALYSIS OF SYNCHROTRON RADIATION USING SYNRAD3D AND PLANS TO CREATE A PHOTOEMISSION MODEL

HOW TO APPROACH SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE SPECTROSCOPY ANALYSIS. SCSAM Short Course Amir Avishai

Neutron facilities and generation. Rob McQueeney, Ames Laboratory and Iowa State University

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

Signal to noise Source of noise Signal to noise enhancement

Transcription:

Swanning about in Reciprocal Space or, Kenneth, what is the wavevector? Stanford Synchrotron Radiation Laboratory

Principles The relationship between the reciprocal lattice vector and the wave vector is the key to understanding how to scan Inverse nature of real and reciprocal space drives the scan parameters Reciprocal space is a very big space to get lost in Once you understand the kinds of scans you want and the signal leaving the sample, you can choose a detector for the experiment

Memorize: q = 4 sin / (units of 1/Å) E = hc / where hc = 12400 ev-å q max ~ E (in kev) s = r

What energy should I use? Are you doing anomalous scattering? Typically work 100 and 10 ev below the edge Does the sample fluoresce? One solution: use energy less than edge Second: Use either crystal analyzer or solid-state detector to discriminate against fluorescence Tune photon energy to deal with sample absorption edges

What energy should I use? What r-space resolution do you need? Good r-space resolution = large q-max. Do you want to look at multiple reflections in the same zone? Higher orders require higher energy Are there sample environment issues (penetration problems)? Higher energies will penetrate more, but flux lower at higher energy Not as many photons at high energy (> 20 kev) Energy above mirror cutoff -> unfocused experiment It is amazing how many synchrotron experiments use Cu Ka (8048 ev) If none of the above matter, I will use 10 kev as a good balance between resolution and flux

What Slits should I use? Incident vertical beam divergence typically 0.1 mrad. 17 mrad~1 degree Beam divergence drives powder diffraction collection strategy If information is slowly varying in angle-space, use large slits Amorphous materials Crystal truncation rods Small grain-size materials with large rocking curve widths Typical HeNe laser pointer has a divergence of 1 mrad

What Slits should I use? Analyzer crystal: Very good angular resolution (Ge(111) ~100 microradian acceptance) Soller slits: parallel plates to accept same angular value from a large sample- typical angular resolution 1mradespecially effective for grazing incidence scattering from thin films Detector Soller Slits Cable (mangled by previous user)

Scan rules of thumb 8 7 Data Fit Scan step size ~ slit size 1mm slit @ 1 m = 1 mrad 0.05 deg steps ~ 1 mrad ~20 points to determine peak position 6 5 4 3 2 1 0 2.4 2.41 2.42 2.43 2.44 2.45 2.46 2.47 Xpos Not really enough points to effectively determine background, ok for peak position.

Powder diffraction: Reciprocal lattice is spherically averaged Match step size to 2theta resolution Incident beam divergence too good, need to rotate sample to get good powder average Rock sample (flat plate) Spin sample (capillary sample) Make sure sample is ground sufficiently small

What is the Orientation Matrix? Data collection program needs to know how the crystal is mounted on the diffractometer to know where a reflection is Needs to know crystal parameters (a 0,b 0,c 0,,, ) Needs to know angle settings for two roughly orthogonal reflection (zones, e.g. 100 and 010) Only needs to know Omega, Chi, Phi for each reflection Omega is the difference between Theta and 1/2(2Theta)

What is Calculation Mode? 4-circle diffractometer has too many degrees of freedom. Must set one additional boundary condition. Simplest B.C. is to fix Theta = 1/2(2Theta), aka "Omega= zero". For 2-circle diffractometers, still several modes: powder, 2circle, nocell Kappa geometry can also have a symmetric mode (komega) For real power-users, there is "psi" mode and its siblings.

Thin film Scattering: Set up orientation matrix so that h,k in plane, l along plane normal Scans at constant l are scans at constant incident and take-off angle Soller slits critical for good angular resolution sin( ) sin( ) = sin( ) where is angle of incidence

Amorphous or Liquid Scattering: r-space resolution defined by q max q max of 20 -> 2 /20 ~ 0.6 Å resolution q-space resolution defines r max q of 0.2 -> r max of 31 Å Counting for constant signal better than constant I 0 Reduction of background critical

Single Crystal Phase Transitions: First-order phase transition occurs throughout entire crystal, so need v. good q-space resolution Match Analyzer crystal to monochromator to minimize dispersion Scan along principle RLV (h,k,l) rather than pure radial scan

Detectors for SR experiments What is quantum efficiency of detector? What is energy resolution of detector? At what count rate does it go non-linear? How well does it monitor the beam?

Ion Chamber Different gases used for different energies Linearity depends on what gas is used Is capable of absolute flux measurement (if done correctly) Must ensure voltage is in plateau region

Schematic of an Ion Chamber High Voltage Supply (negative bias) X-rays Nitrogen Gas Current to voltage amplifier

Convert ion chamber current to photon flux: Flux [hv/sec] = I abs [coul/sec] * 34.6 [ev/e-] (1-e -mu*l )*1.6e-19[coul/e-]*Energy[ev/hv] 0.1 microamp absorbed current 15 cm chamber length 10 kev photons 0.0044 [1/cm] mu (N 2, 10 kev) 0.1 µa ~ 3.4 x 10 10 ph/s Ion trapping (incomplete charge collection) occurs at high fluxes (> 10 11 ph/sec). Increasing voltage on ion chamber can help, but reducing absorption cross-section of gas is better solution.

Bicron (NaI detector) Based on conversion of x-ray photon into visible light which is converted to electrons (aka scintillator) Fast (linear up to ~40 kps) Deadtime correction at higher count rates 50% energy resolution Ok for separation of harmonic from fundamental Not sufficient to remove most fluorescence NOT happy looking at main beam Low background (few cps)

Solid State Ge detector Good energy resolution (200-300 ev resolution) Trade energy resolution for count rate Moderate count rate (linear to ~10 kps) Good choice if fluorescence background Not sufficient for elastic-k b separation Need regular (2x per day) N 2 filling Very low background (< 1cps)

Vortex (Si drift) detector V. high count rate (linear to 100 kps?) V. good energy resolution (150 ev) No need for LN (Peltier-cooled) Compact, so easy to install on 2theta Small detector effective area Not an issue with slits An issue with Soller slits

Conclusions Work with scientific staff before arrival to determine best energy, detector, slits, etc Familiarize yourself with SCALC (available on SSRL alpha) Think about the information you want: Peak shape? Peak position? Variation of peak with q? How long will you need to count? 10 k cts has sqrt(n) < 1% Is that sufficient? If you are unfamiliar with the instrument, plan to sit in with another team and ask questions.