Exchangeable measuring insets SensyTemp TSA101

Similar documents
A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

Temperature sensors SensyTemp TSP311, TSP321, TSP331

Field mounted Temperature Transmitter TF212/TF212-Ex

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Field IT 50T Series Transmitters

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

ATEX/IECEx RTD temperature probe

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

ED 701 General Industry Pressure Transmitter

Operating limits and tolerances of platinum resistance thermometers per EN 60751: 2008

Mineral-insulated thermocouples to DIN and EN

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

SensyTemp TSP341-N High-precision non-invasive temperature measurement

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Z7A. Load cells. Special features. Data sheet. Wiring code

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Wake Frequency Calculations Solid Drilled Thermowells

Construction and application of resistance thermometers

Pressure Measurement Single-range transmitters for general applications

Single point load cells

Temperature measurement

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

Measurement of Temperature in the Plastics Industry

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

ct m ive p 5/EC Thermal cut-outs

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Introduction to Edition II with comparative measurements

Pressure transmitters for industrial applications MBS 32 and MBS 33

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Temperature Measurement

Industrial Resistance Thermometers according to DIN Model MWD

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

Installation guide 862 MIT / MIR

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Physikalisch-Technische Bundesanstalt

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

PHOENIX CONTACT - 04/2016. Features

Operating Instructions for Digital Manometer. Model: MAN-SD

EX-EMERGENCY LIGHT FITTINGS

SEN TRONIC AG 1 A 6 6 / "

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

Pressure Transmitter ED 701

Type UB1 Load Cell. Option Stainless steel cable gland

Ex floating switches and Ex immersion probes

Air velocity & IAQ measuring instruments

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Solenoid valves Type EVUL

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

Temperature. 3

ZF Series Force Transducers

Switches in conformity with ATEX directive

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Ring-Torsion Load Cells RTB

Air velocity & IAQ measuring instruments

Certificate No.: IECEx BVS , issue 3 Annex Page 1 of 9

SmartLine Radar Level Meter RM70

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

473 Dew Point Hygrometer

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Qualification Test Report. Modular Plugs, Unshielded and Shielded

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

473 Dew Point Hygrometer

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Linear measuring technology

Reflex-Radar BM 100 A

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

PRODUCT CATALOGUE PREssURE switch

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

ISEmax CAS40D. Technical Information

BMXART0814 analog input module M340-8 inputs - temperature

g/cm³ DAkkS Calibration Laboratory for Temperature and Density High-precision calibration for temperature and density

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

ISEmax CAM40/CAS40. Technical Information

CDS. high density spring connection

Ultrasonic Gas Flow Meter

8 Installation Equipment

5SJ4...-.HG Circuit Breakers to IEC and UL 489

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Absolute encoders multiturn

TÜV NORD CERT GmbH Hanover Office Am TÜV Hanover Germany. Testing Laboratory Explosion Protected Equipment and Monitoring Devices

all stainless steel transducer multimedia compatibility

Transcription:

Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular design - Less effort for recovery with maximum flexibility and system uptime Functionality of the modular system - Protection against mechanical and chemical stress based on thermowells of various designs - Exchangeable measuring inset generates measuring signal - Transmitter provides interface to latest process management systems Areas of application - Offshore and coastal areas - Petroleum and natural gas production and transport - Petrochemical, chemical and energy industry - Manufacturing systems and plant engineering - General process engineering - Tank and pipeline construction - Food and drink industry Structure of mineral-insulated, plastic-sheathed cable - High vibration resistance, ductility, temperature capacity and electrical insulation Spring-loaded attachment to base plate - This ensures the measuring inset tip is pressed against the bottom of the thermowell. This results in: - short response times - Reduce natural oscillation Approvals - For mounting on approved TSP temperature sensors: - Intrinsically safe, hermetically sealed, dust ignition proof - GOST Russia, Kazakhstan, Ukraina Wide selection of sensors and interfaces P R O F I PROCESS FIELD BUS B U S Easy to replace Multi-purpose With integrated transmitter

Exchangeable measuring insets SensyTemp TSA101 Contents 1 Overview of measuring insets...3 2 Design...4 3 General information...4 3.1 Measurement accuracy of mounted transmitter...4 3.2 Vibration resistance of measuring inset...4 3.3 Insulation resistance of measuring inset...4 3.4 Measurement range of measuring inset...5 3.5 Accuracy of measuring element...5 3.6 Measuring inset designs...7 3.7 Recalibration recommendations...7 4 Terminal connection diagrams...8 4.1 Resistance thermometers...8 4.2 Thermocouples...8 5 Ordering information...9 2

Exchangeable measuring insets SensyTemp TSA101 1 Overview of measuring insets Type Sheathed thermocouples and sheathed resistance thermometers M M M )#" )#! )# Electrical connection Installed ABB transmitter Flying leads Terminal block Design Mineral insulated cable: flexible, bendable, vibration resistant Standard DIN 43 735 Updated 04/2005 Sensor types Measuring inset diameter Standard measuring elements Standard sheath material Design of measuring point Spring travel Explosion protection class Temperature Application Resistance thermometers, thermocouples Ø = 1 mm less than inside diameter of the thermowell Resistance thermometers: (EN 60751) Thermocouples: (EN 60584) Resistance thermometers: Thermocouples: Pt100 basic application (-50... 400 C), single/dual, 3-/4-wire connection Pt100 extended measuring range (-200... 600 C), single/dual, 3-/4-wire connection Type K, J and N, single/dual 1.4571 (SS 316Ti) 2.4816 (Inconel 600) Standard: Insulated, optional with thermocouples: grounded Approx. 10 mm Intrinsically safe ATEX II 1 G EEx ia IIC T6... T1; for installation in ABB temperature sensors TSP1X1, TSP3X1 Dust ignition proof ATEX II 1 D T135... T450; for installation in ABB temperature sensors TSP1X1, TSP3X1 Hermetically sealed ATEX II 1/2 G EEx d IIC T6... T4; for installation in ABB temperature sensors TSP3X1 Note: Requirements for NAMUR NE24 recommendation are fulfilled by ATEX EEx i. Resistance thermometers: Basic application: -50... 400 C Extended vibration resistance: -50... 400 C Extended measuring range: -200... 600 C Thermocouples Type K, J and N: Approx. -40... 1000 C Installation in TSP temperature sensors Note For higher resistance to vibrations, resistance measuring insets with higher resistance to vibrations or thermocouples are recommended. For information on additional sensor models, sheath materials and diameters, contact your ABB sales representative. 3

Wechsel ein-auf zweispaltig Exchangeable measuring insets SensyTemp TSA101 A 2 Design M B A TEL Fig. 1 NBL A00069 A Measuring inset diameter B Mineral-insulated, plastic-sheathed cable, with compact wires embedded in MgO M Measuring inset length Connector base Base: Distance between screws: Screw size: Spring travel: 42 mm 33 mm M4 x 1.5 > 10 mm TEL NBL Temperature-sensitive length Non-bendable length 3 General information 3.1 Measurement accuracy of mounted transmitter For information on transmitter accuracy, refer to the documentation on transmitters. 3.2 Vibration resistance of measuring inset Use of plastic-sheathed cables and special measuring elements, including their installation, results in a very high vibration resistance for all measuring insets of the TSP temperature sensor. The acceleration values of 3 g, defined in accordance with EN 60751 (IEC 751) for additional requirements, are exceeded by all measuring inset models in TSP temperature sensors. The following table provides an overview of the vibration resistance in accordance with EN 60751 for the measuring inset models (on hot side), as well as the temperature-sensitive sections and the nonbendable sections at the tip of the measuring inset. 3.3 Insulation resistance of measuring inset The insulation resistance is measured between outside sheath and measuring circuit. In case of two measuring circuits, the insulation resistance between both measuring circuits is also measured. The following applies for all measuring inset models: R iso > 500 MΩ at 500 V DC/AC, 15 C < T u < 35 C, relative humidity < 80% As a result of a special process during manufacturing, ABB measuring insets also have outstanding insulation values at high temperatures. Vibration resistance EN 60751 (tip-tip) Measuring insetdesign temperaturesensitive section nonbendable section Pt100, Basic application 10 g 7 mm 30 mm (-50 400 C) Pt100, Extended vibration resistance 60 g 10 mm 40 mm (-50 400 C) Pt100, Extended measuring range 10 g 50 mm 60 mm (-200 600 C) Thermocouple 60 g 3 mm 20 mm 4

Wechsel ein-auf zweispaltig Exchangeable measuring insets SensyTemp TSA101 3.4 Measurement range of measuring inset Resistance thermometers Basic application Extended vibration resistance Extended measuring range Thermocouple Type K Type J Type N -50... 400 C -50... 400 C -200... 600 C -40 1000 C -40 750 C -40... 1000 C 3.5 Accuracy of measuring element Resistance thermometers Basic application Class B: Δt = ± (0.30 + 0.0050 t ) -50... 400 C Class A: Δt = ± (0.15 + 0.0020 t ) -30... 350 C Δt = ± (0.30 + 0.0050 t ) -50... -30 / 350... 400 C 1/3 Class B: Δt = ± (0.10 + 0.0017 t ) 0... 100 C Δt = ± (0.15 + 0.0020 t ) -30... 0 / 100... 350 C Δt = ± (0.30 + 0.0050 t ) -50... -30 / 350... 400 C Extended vibration resistance Class B: Δt = ± (0.30 + 0.0050 t ) -50... 400 C Class A: Δt = ± (0.15 + 0.0020 t ) -30... 350 C Δt = ± (0.30 + 0.0050 t ) -50... -30 / 350... 400 C Extended measuring range Class B: Δt = ± (0.30 + 0.0050 t ) -200... 600 C Class A: Δt = ± (0.15 + 0.0020 t ) -200... 600 C Note The resistance of the copper inner conductor for the measuring inset affects the measurement value of 2-wire connections and must be taken into consideration. The diameter and length of the measuring inset are determining factors. If the error cannot be compensated mechanically, the following values apply: Ø measuring inset 3 mm: (0.281 Ω/m +0.7 C/m) Ø measuring inset 6 mm: (0.1 Ω/m +0.25 C/m) ABB provides standard 3- or 4-wire circuits. This eliminates the error. Wechsel ein-auf zweispaltig Measurement resistances: Tolerances in accordance with EN 60751 (IEC 60751) Fig. 2 X Y Temperature Upper/lower deviation (+/-) / Kelvin A B Tolerance class A Tolerance class B 5

Exchangeable measuring insets SensyTemp TSA101 Thermocouple The measurement accuracy of the ABB standard thermocouples complies with international standard IEC 584 / EN 60584. Thermocouples compliant with ANSI MC96.1 are also available upon request. Since the values of both standards vary only marginally in the lower temperature range (up to approx. 300 C), we recommend the use of thermocouples compliant with international standard IEC 584. The tolerance information must be defined in the table "Tolerance classes". Wechsel ein-auf zweispaltig Tolerance classes Standard TE type Class Temperature range Maximum deviation EN 60584 / IEC 584 K (NiCr-Ni) J (Fe-CuNi) N (NiCrSiNiSi) 2 1 2 1 2 1-40... 333 C ±2.5 C 333... 1200 C ±0.0075 x [t] -40... 375 C ±1.5 C 375... 1000 C ±0.0040 x [t] -40... 333 C ±2.5 C 333... 750 C ±0.0075 x [t] -40... 375 C ±1.5 C 375... 750 C ±0.0040 x [t] -40... 333 C ±2.5 C 333... 1200 C ±0.0075 x [t] -40... 375 C ±1.5 C 375... 1000 C ±0.0040 x [t] Standard TE type Class Temperature range Maximum deviation ANSI MC96.1 K (NiCr-Ni) J (Fe-CuNi) N (NiCrSiNiSi) Standard Special Standard Special Standard Special -0... 293 C ±2.2 C 293... 1250 C ±0.0075 x [t] -0... 275 C ±1.1 C 275... 1250 C ±0.0040 x [t] -0... 293 C ±2.2 C 293... 750 C ±0.0075 x [t] -0... 275 C ±1.1 C 275... 750 C ±0.0040 x [t] -0... 293 C ±2.2 C 293... 1250 C ±0.0075 x [t] -0... 275 C ±1.1 C 275... 1250 C ±0.0040 x [t] Thermocouple: Tolerances in accordance with EN 60584 (IEC 60584) Fig. 3 X Y Temperature Upper/lower deviation (+/-) / Kelvin A, C Tolerance class 2 B, D Tolerance class 1 6

Wechsel ein-auf zweispaltig Wechsel ein-auf zweispaltig Exchangeable measuring insets SensyTemp TSA101 3.6 Measuring inset designs 3.6.1 Resistance thermometers, basic application Single Dual 2-wire circuit 3-wire circuit 4-wire circuit 2-wire circuit 3-wire circuit 4-wire circuit 3 mm, class B x x x - - - 3 mm, class A - x x - - - 6 mm, class B x x x x x x 6 mm, class A - x x - x x 3.6.2 Resistance thermometers, extended vibration resistance Single Dual 2-wire circuit 3-wire circuit 4-wire circuit 2-wire circuit 3-wire circuit 4-wire circuit 3 mm, class B - - - - - - 3 mm, class A - - - - - - 6 mm, class B x x x x x x 6 mm, class A - x x - x x 3.6.3 Resistance thermometer, extended measuring range Single Dual 2-wire circuit 3-wire circuit 4-wire circuit 2-wire circuit 3-wire circuit 4-wire circuit 3 mm, class B x x x - x x 3 mm, class A - x x - - - 6 mm, class B x x x x x x 6 mm, class A - x x - - - 3.6.4 Thermocouple 1 x type K 2 x type K 1 x type J 2 x type J 1 x type N 2 x type N 3 mm, class 2 x x x x - - 3 mm, class 1 x x x x - - 6 mm, class 2 x x x x x x 6 mm, class 1 x x x x x x 3.7 Recalibration recommendations Recommended values for a maximum uniform operating temperature: 400 C recalibration at the latest after two years 200 C recalibration at the latest after five years Depending on process requirements (e.g., increased accuracy, system availability, safety) and with above-average stress (strong vibrations, frequent and rapid temperature fluctuations, etc.), the time periods might have to be significantly shortened. 7

Resistance Exchangeable measuring insets SensyTemp TSA101 4 Terminal connection diagrams 4.1 Resistance thermometers In accordance with EN 60751 (IEC 60751) Single 2-wire circuit 3-wire circuit 4-wire circuit Fig. 4 R red In accordance with EN 60751 (IEC 60751) Dual 2-wire circuit 3-wire circuit 4-wire circuit Fig. 5 Y yellow B black R red W white 4.2 Thermocouples Single In accordance with EN 60584 Dual Fig. 6 8

Exchangeable measuring insets SensyTemp TSA101 Order information 5 Ordering information Exchangeable measuring inset Variant digit No. 1-7 8 9 10 11 12 13 14 15 Code SensyTemp TSA101 Catalog No. TSA101- for resistance thermometers and thermocouples Explosion protection / approval Without Y 0 Intrinsic Safety: ATEX II 1 G EEx ia IIC T6... T1 - Zone 0, 1, 2 A 1 Dust ignition proof: ATEX II 1 D IP6X T133... T400 - Zone 20, 21, 22 A 3 Dust ignition proof and intrinsic safety: ATEX II 1 D IP6X T133... T400 A 4 and ATEX II 1 G EEx ia IIC T6... T1 - Zone 0, 1, 2, 20, 21, 22 Flameproof Enclosure: ATEX II 1/2 G EEx d IIC T6... T4 - Zone 1 A 5 ATEX II 3 G EEx na II T6... T1 B 1 and ATEX II 3 D IP6X T133... T400 - Zone 2 and 22 Others Z 9 Measuring inset type Resistance thermometer, basic application, measuring range -50... 400 C S 1 Resistance thermometer, extended vibration resistance, S 2 measuring range -50... 400 C Resistance thermometer, extended measuring range -200... 600 C D 1 Thermocouple T 1 Others Z 9 Measuring inset diameter 3 mm 4) D 3 6 mm D 6 6 mm, tip with additional sleeve 8 mm H 8 6 mm, tip with additional sleeve 10 mm H 1 Others Z 9 Sensor type and wiring 1 x Pt100, 2-wire 5) P 1 1 x Pt100, 3-wire 5) P 2 1 x Pt100, 4-wire 5) P 3 2 x Pt100, 2-wire 6, 7) P 4 2 x Pt100, 3-wire 6, 7) P 5 2 x Pt100, 4-wire 6, 8) P 6 1 x Type K (NiCr-Ni) 9) K 1 2 x Type K (NiCr-Ni) 9, 7) K 2 1 x Type J (Fe-CuNi) 9) J 1 2 x Type J (Fe-CuNi) 9, 7) J 2 1 x Type N (NiCrSi-NiSi) 9) N 1 2 x Type N (NiCrSi-NiSi) 9, 7) N 2 Others Z 9 4) Not available with Measuring inset type code S2 Continued on next page 5) Not available with Measuring inset type code T1 6) Not available with Measuring inset type code S2, T1 7) Not available with Measuring inset diameter code D3 and Explosion protection / approval code A1, A3, A4, A5, B1 8) Not available with Measuring inset diameter code D3 9) Not available with Measuring inset type code S1, S2, D1 9

Exchangeable measuring insets SensyTemp TSA101 Exchangeable measuring inset Variant digit No. 1-7 12 13 14 15 16 17 18 19 Code SensyTemp TSA101 Catalog No. TSA101- for resistance thermometers and thermocouples Sensor accuracy Standard accuracy EN 60751 class B 5) B 2 Extended accuracy EN 60751 class A from -30... 350 C 10, 11) S 1 Extended accuracy EN 60751 class A from -200... 600 C 12, 13) D 1 Standard accuracy EN 60584 class 2 9) T 2 Extended accuracy EN 60584 class 1 9, 14) T 1 High accuracy EN 60751 1/3 class B from 0... 100 C 10, 8, 13) S 3 Others Z 9 Inset length M M = 255 mm M 1 M = 270 mm H 1 M = 285 mm D 1 M = 300 mm D 2 M = 315 mm M 2 M = 330 mm H 2 M = 355 mm H 3 M = 375 mm D 3 M = 390 mm D 4 M = 405 mm M 3 M = 420 mm H 4 M = 435 mm D 5 M = 450 mm D 6 M = 455 mm H 5 M = 505 mm H 6 M = 555 mm M 4 M = 570 mm H 7 M = 585 mm D 7 M = 600 mm D 8 M = 605 mm H 8 M = 1025 mm M 5 Acc. to customer specification (price per each commencing 100 mm) Z 9 5) Not available with Measuring inset type code T1 Continued on next page 8) Not available with Measuring inset diameter code D3 9) Not available with Measuring inset type code S1, S2, D1 10) Not available with Measuring inset type code S2, D1, T1 11) Not available with Sensor type and wiring code P1, P4, K1, K2, J1, J2, N1, N2 12) Not available with Measuring inset type code S1, S2, T1 13) Not available with Sensor type and wiring code P1, P4, P5, P6, K1, K2, J1, J2, N1, N2 14) Not available with Sensor type and wiring code P1, P2, P3, P4, P5, P6 10

Exchangeable measuring insets SensyTemp TSA101 Exchangeable measuring inset Variant digit No. 1-7 14 15 16 17 18 19 20 21 Code SensyTemp TSA101 Catalog No. TSA101- for resistance thermometers and thermocouples Transmitter Without transmitter, measuring inset with ceramic terminal block Y 1 Without transmitter, measuring inset with flying leads Y 2 TR04, fixed range, output signal 4... 20 ma 18, 19) R 1 TR04-Ex, fixed range, output signal 4... 20 ma 20, 19) R 2 TH01, programmable, output signal 4... 20 ma 18) P 1 TH01-Ex, programmable, output signal 4... 20 ma 20) P 2 TH02, programmable, output signal 4... 20 ma, HART 18) H 1 TH02-Ex, programmable, output signal 4... 20 ma, HART 20) H 2 TTH300, programmable, output signal 4... 20 ma, HART 18) H 4 TTH300 (Ex-version), programmable, output signal 4... 20 ma, HART 20) H 5 TF12, programmable, output PROFIBUS PA 18) F 1 TF12-Ex, programmable, output PROFIBUS PA 20) F 2 TF02, programmable, output FOUNDATION Fieldbus 18) F 3 TF02-Ex, programmable, output FOUNDATION Fieldbus 20) F 4 Others Z 9 18) Not available with Explosion protection / approval code A1, A4, B1 19) Not available with Sensor type and wiring code P3, P6, K1, K2, J1, J2, N1, N2 20) Not available with Explosion protection / approval code Y0, A3, A5, B1 11

Exchangeable measuring insets SensyTemp TSA101 Additional ordering information Exchangeable measuring inset SensyTemp TSA101 Code Name plate Stainless steel plate with TAG no. T1 Certificates Inspection certificate 3.1 acc. to EN 10204 for sensor calibration 1 x Pt100 5, 22, 28) CD Inspection certificate 3.1 acc. to EN 10204 for sensor calibration 2 x Pt100 5, 23, 28) CE Inspection certificate 3.1 acc. to EN 10204 for sensor calibration 1 x thermocouple 9, 24, 28) CF Inspection certificate 3.1 acc. to EN 10204 for sensor calibration 2 x thermocouple 9, 25, 28) CG Inspection certificate 3.1 acc. to EN 10204 for DKD sensor calibration 1 x Pt100, 5, 22, 28) CH separate calibration certificate for each thermometer Inspection certificate 3.1 acc. to EN 10204 for DKD sensor calibration 2 x Pt100, 5, 23, 28) CJ separate calibration certificate for each thermometer Inspection certificate 3.1 acc. to EN 10204 for DKD sensor calibration 1 x thermocouple, 9, 24, 28) CK separate calibration certificate for each thermometer Inspection certificate 3.1 acc. to EN 10204 for DKD sensor calibration 2 x thermocouple, 9, 25, 28) CL separate calibration certificate for each thermometer Others CZ Temperatures for sensor calibration 1 x Pt100 / 1 x TC 0 C / 32 F 26) V1 100 C / 212 F 26) V2 0 C and 100 C / 32 F and 212 F 26) V4 As specified by customer (price per calibration point) 26) V6 2 x Pt100 / 2 x TC 0 C / 32 F 26) V1 100 C / 212 F 26) V2 0 C and 100 C / 32 F and 212 F 26) V4 As specified by customer (price per calibration point) 26) V6 Temperatures for DKD calibration 1 x Pt100 / 1 x TC 0 C / 32 F 27) D1 100 C / 212 F 27) D2 0 C and 100 C / 32 F and 212 F 27) D4 As specified by customer (price per calibration point) 27) D6 2 x Pt100 / 2 x TC 0 C / 32 F 27) D1 100 C / 212 F 27) D2 0 C and 100 C / 32 F and 212 F 27) D4 As specified by customer (price per calibration point) 27) D6 5) Not available with Measuring inset type code T1 9) Not available with Measuring inset type code S1, S2, D1 22) Not available with Sensor type and wiring code P4, P5, P6, K1, K2, J1, J2, N1, N2 23) Not available with Sensor type and wiring code P1, P2, P3, K1, K2, J1, J2, N1, N2 24) Not available with Sensor type and wiring code P1, P2, P3, P4, P5, P6, K2, J2, N2 25) Not available with Sensor type and wiring code P1, P2, P3, P4, P5, P6, K1, J1, N1 26) Not available with Certificates code CH, CJ, CK, CL 27) Not available with Certificates code CD, CE, CF, CG 28) Price per order line 12

ABB provides expert and comprehensive consulting services in more than 100 countries worldwide. www.abb.com/temperature ABB is continually improving its products. As a result, technical information in this document is subject to change. Printed in the Fed. Rep. of Germany (04.2006) ABB 2006 3KXT111001R1001 ABB Limited Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Tel: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products GmbH Borsigstr. 2 63755 Alzenau Germany Tel: +49 551 905-534 Fax: +49 551 905-555 CCC-support.deapr@de.abb.com