New generation of a mobile primary frequency standard based on cold atoms

Similar documents
Compact Frequency Standard Based on an Intra-cavity Sample Cold Cesium Atoms

Compact frequency standard based on an intracavity sample of cold cesium atoms

High Accuracy Strontium Ion Optical Clock

A Miniature Cold-Atom Frequency Standard

Historical overview of Ramsey spectroscopy and its relevance on Time and Frequency Metrology

F.G. Major. The Quantum Beat. The Physical Principles of Atomic Clocks. With 230 Illustrations. Springer

TOWARDS DEMONSTRATION OF A MOT-BASED CONTINUOUS COLD CS-BEAM ATOMIC CLOCK

PROGRESS TOWARDS CONSTRUCTION OF A FERMIONIC ATOMIC CLOCK FOR NASA S DEEP SPACE NETWORK

Atomic Clocks. Ekkehard Peik. Physikalisch Technische Bundesanstalt Time and Frequency Department Braunschweig, Germany

CESIUM ATOMIC FOUNTAIN CLOCKS AT NMIJ

Optical Lattice Clock with Neutral Mercury

Tests of Cold Atom Clock in Orbit

National Physical Laboratory, UK

PROGRESS TOWARDS CONSTRUCTION OF A FERMION ATOMIC CLOCK FOR NASA S DEEP SPACE NETWORK

Laser-Cooled Continuous Cs-Beam Master Oscillator

Optical Lattice Clock with Spin-1/2 Ytterbium Atoms. Nathan D. Lemke

Transportable optical clocks: Towards gravimetry based on the gravitational redshift

Atomic clocks. Clocks

Overview of Frequency Metrology at NMIJ

Improvement of the Frequency Stability Below the Dick Limit With a Continuous Atomic Fountain Clock

Uncertainty evaluation of the caesium fountain clock PTB-CSF2

Overview of Frequency Metrology at NMIJ

Development of a compact Yb optical lattice clock

Overview of Frequency Metrology at NMIJ

Comparison with an uncertainty of between two primary frequency standards

THE SPACE OPTICAL CLOCKS PROJECT

Microwave and optical spectroscopy in r.f. traps Application to atomic clocks

Fold optics path: an improvement for an atomic fountain

Systematic Effects in Atomic Fountain Clocks

Laser cooling and trapping

Atom Quantum Sensors on ground and in space

Magneto-Optical Trap for Sodium Atoms from a Vapor Cell and Observation of Spatial Modes

Journées Systèmes de Référence Spatio-Temporels 2011 September 19 th 2011 Vienna, Austria

Primary Frequency Standards at NIST. S.R. Jefferts NIST Time and Frequency Division

Atom-based Frequency Metrology: Real World Applications

The Brazilian Time and Frequency Atomic Standards Program

Towards a compact cold atom frequency standard based on coherent population trapping

Optical Clocks and Tests of Fundamental Principles

EYLSA laser for atom cooling

Coherent manipulation of atomic wavefunctions in an optical lattice. V. V. Ivanov & A. Alberti, M. Schioppo, G. Ferrari and G. M.

Doppler-free spectroscopy of the 'ANTPOT. 1 S IND.0-''ANTPOT.3 P IND.0' optical clock transition in laser-cooled fermionic isotopes of neutral mercury

The Quantum Beat. Second Edition

Towards compact transportable atom-interferometric inertial sensors

arxiv: v1 [physics.ins-det] 25 May 2017

Cold Atom Clocks on Earth and in Space Fundamental Tests and Applications. C. Salomon Laboratoire Kastler Brossel, Ecole Normale Supérieure, Paris

Part IV. Fundamentals of Laser Spectroscopy

Miniaturized optical system for atomic fountain clock

Fundamental Constants and Units

Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock

Dr. Jean Lautier-Gaud October, 14 th 2016

Multipath Interferometer on an AtomChip. Francesco Saverio Cataliotti

Status of the ACES/PHARAO mission

Optimization and analysis of experimental parameters for. polarization gradient cooling in optical molasses

Laser-Based Measurements for Time and Frequency

Timing Applications and User Equipment R. Michael Garvey. Time and Frequency Services with Galileo Workshop. 5-6 December 2005

Roger Ding. Dr. Daniel S. Elliott John Lorenz July 29, 2010

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

SR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY *

Fundamentals: Frequency & Time Generation

laser with Q-switching for generation of terahertz radiation Multiline CO 2 Journal of Physics: Conference Series PAPER OPEN ACCESS

CESIUM ATOMIC FOUNTAIN CLOCKS AT NMIJ

Forca-G: A trapped atom interferometer for the measurement of short range forces

Elements of Quantum Optics

PUBLISHED VERSION. 1 August, 2017

AC-DC Transfer Difference Measurements using a Frequency Output Thermal Converter

Clock tests of space-time variation of fundamental constants

Interferometric determination of thermal expansion coefficient of piston/cylinder unit preliminary investigation

arxiv:physics/ v1 [physics.atom-ph] 7 Nov 2006

Microwave clocks and fountains

Cold atom Clocks and Applications

Citation for published version (APA): Mollema, A. K. (2008). Laser cooling, trapping and spectroscopy of calcium isotopes s.n.

Atomic fountain clocks

A COMPACT, CONTINUOUS BEAM COLD ATOM CLOCK FOR SATELLITE APPLICATIONS

The cesium frequency standard

Laser cooling of 173 Yb for isotope separation and precision hyperfine spectroscopy

Analysis of Short-Term Stability of Miniature

ATOMIC AND LASER SPECTROSCOPY

Observation of the nonlinear phase shift due to single post-selected photons

STUDIES OF NPL S CLOCK ENSEMBLE ALGORITHM

Les Puces à Atomes. Jakob Reichel. Laboratoire Kastler Brossel de l E.N.S., Paris

Experimental Set-up of the 532nm Green Laser for the Measurement of the AC Stark Shift in a Cesium Fountain Clock

RACE: Rubidium Atomic Clock Experiment

Magnetic Field measurements with Csmagnetometers

SYRTE - IACI. AtoM Interferometry dual Gravi- GradiOmeter AMIGGO. from capability demonstrations in laboratory to space missions

arxiv: v2 [physics.atom-ph] 18 Jun 2013

Laser Cooling of Thulium Atoms

State of the art cold atom gyroscope without dead times

1. Introduction. 2. New approaches

Development of a 171 Yb + Microwave Frequency Standard at the National Measurement Institute, Australia

Sapphire decelerating capillary channel integrated with antenna at frequency THz

CW-Lyman- Source for Laser Cooling of Antihydrogen in a Magnetic Trap

σ(τ) = 1 ηe 1 ν (a) (b)

Vacuum measurement on vacuum packaged MEMS devices

Intensity Dependence for Trap Loss Rate in a Magneto-Optical Trap of Strontium

Titelmasterformat durch About atomic (optical) clocks Klicken bearbeiten

Estimating the trajectory of a space vehicle passing by the Moon using Kalman Filter

THE FUTURE MODEL OF TA (TL)

Construction of an absolute gravimeter using atom interferometry with cold 87. Rb atoms

Advanced accelerometer/gradiometer concepts based on atom interferometry

Experimental Demonstration of Spinor Slow Light

Transcription:

Journal of Physics: Conference Series OPEN ACCESS New generation of a mobile primary frequency standard based on cold atoms To cite this article: S T Müller et al 015 J. Phys.: Conf. Ser. 575 01030 Related content - Evaluation of NPL-CsF1 K Szymaniec, W Chalupczak, P B Whibberley et al. - First accuracy evaluation of the NPL-CsF primary frequency standard Krzysztof Szymaniec, Sang Eon Park, Giuseppe Marra et al. - Cold atom clocks and applications S Bize, P Laurent, M Abgrall et al. View the article online for updates and enhancements. This content was downloaded from IP address 4.3.01.0 on 18/0/018 at 1:09

VII Brazilian Congress on Metrology (Metrologia 013) Journal of Physics: Conference Series 575 (015) 01030 New generation of a mobile primary frequency standard based on cold atoms S T Müller 1, J de Martin Júnior 1, R D Pechoneri 1, P Santa Catharina 1, V S Bagnato and D V Magalhães 1 1 Departamento de Engenharia Mecânica, Escola de Engenharia de São Carlos, Universidade de São Paulo, São Carlos, Brazil Departamento de Física e Ciência dos Materiais, Instituto de Física de São Carlos, Universidade de São Paulo, São Carlos, Brazil E-mail: stella@ifsc.usp.br Abstract. We have constructed a mobile primary frequency standard using intra-cavity cold cesium atoms and the results have shown the advantages of using this kind of system compared to cesium beam standards. Based on the first setup with an expanding cloud of atoms, we can plan the construction of a clock more compact since it has no strict size limitations. In order to assemble the new system even smaller, the development of a system containing lasers, microwave source and cavity in a single box has already begun. The mobile atomic standard based on cold atoms is a possible strategic product with a broad range of applications and an important contribution to a primary standard of high relevance. 1. Introduction With exceptional accuracy, atomic clocks have applications in several fields of modern fundamental physics [1]. They allow not only to investigate the macroscopic scales theories like relativity or gravitation, but also to know better the microscopic world, in atomic scale, thanks to quantum mechanics. Two of the main applications are navigation and telecommunication systems, and atomic references are the heart of the most advanced navigation system, satellite constellations positioning like GPS, GLONASS, and Beidou []. Most of the high performance time standards require an extremely complex construction and operation, but the size of these systems makes them incompatible with some applications, which require a compromise between size and performance. These include space and industrial applications, such as telecommunication lines, mobile telephone networks or internet, calibration of instruments, dissemination of local time references with good quality, etc. The Atomic Time and frequency Standard Program USP São Carlos [3] started a few years ago with the construction of a thermal beam atomic frequency standard, today our research is focused on the development of two frequency standards based on cold atoms: an atomic fountain [4] and a compact system based in a cold atomic cloud in free expansion [5]. Besides those experimental standards, our facility has commercial atomic clocks and a hydrogen maser. The atomic frequency standards developed up to now provided us the theoretical and experimental knowledge for the development of a mobile atomic frequency standard with the same level of precision Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

VII Brazilian Congress on Metrology (Metrologia 013) Journal of Physics: Conference Series 575 (015) 01030 and stability of the previous setups. The new diode laser sources, microwave synthesizer, vacuum and control systems are being reduced in order to ensure the portability of the system.. Experimental setup and temporal sequence The aim of this project is the construction of a cold atoms compact frequency standard that works in an innovative way, since the steps of the sequence occur in the same place, within a microwave cavity. For the physical package we use a cylindrical cavity, sculpted in a stainless steel vacuum chamber and resonant in 9. GHz. This operation mode allows us to design a much more compact system than a conventional cold atoms clock, where the various interactions are in different parts of the instrument. Therefore, the compactness of the clock is achieved through a sequence purely temporal. The most relevant steps can be seen in Figure 1. Figure 1. Temporal sequence of a clock cycle performed inside the microwave cavity. The temporal sequence of the compact frequency standard can be divided in four well defined steps (see figure 1), as follows: (Step 1)Trapping atoms in a magneto optical trap (MOT) In this stage is possible to capture 10 8 atoms using magnetic field and three counter-propagating pairs of laser beams (MOT) []. This is important to catch up the atoms together in the same spatial region, forming a cold cloud, and to remove a huge portion of the cloud s kinetic energy. In this step the atomic cloud attains very low temperatures and becomes more stable. The S F = 4 P F 5 cycling 3 = transition is used, and repumping is done using the S F = 3 P F 4 transition. 3 = (Step )Sub-Doppler Cooling and the Preparation After the first reduction of the kinetic energy, the system passes from MOT configuration to optical molasses by switching off the current supply of the magnetic field. Simultaneously, the atomic cloud is cooled even more, changing the intensity and detuning of the laser beams with acousto-optical modulators, reaching levels below 10 μk. In order to prepare the atoms in their ground electronic state S F = 3, the repumping light is switched off 5 ms before shutting off the cooling light. During this interval, optical pumping efficiently transfers the atoms to the required ground state. (Step 3) The clock transition interrogation Now, the cold atoms are in a single initial state and after the total shutdown of the lasers beams, the cloud starts a free expansion. During the expansion the atoms are interrogated in a Ramsey sequence

VII Brazilian Congress on Metrology (Metrologia 013) Journal of Physics: Conference Series 575 (015) 01030 [7], consisting of two coherent microwave pulses π with 1ms of duration and separated by 8ms. These pulses excite the clock transition between the two hyperfine levels S F 3, m = 0 S F = 4, m = 0. = F F (Step 4) The Detection To detect the atoms that have transitioned to the S F = 4 level after the two microwave pulses, the light beams originally used as a cooling laser are turned back on for 40 ms, and the fluorescence signal is collected. Once the resonance is observed, it can be used as a frequency discriminator. The transition probability difference of two successive measurement acts as an error signal used to control the local oscillator frequency. 3. Results Figure presents a typical scan of the microwave frequency across the clock resonance in our device [5]. Using the Ramsey fringe of Figure, we can scan around the central fringe to determine the linewidth with a theoretical fitting (Figure 3), obtaining a value of 47 Hz. The contrast is better than 80% (where the contrast is defined as a difference between resonance amplitude and background). To measure the frequency stability of the system is necessary to lock the central resonance observed on figure 3 to the microwave chain (macroscopic oscillator). The microwave chain on the other hand is phase locked to the 5 MHz output of the Hydrogen Maser. The modulation of the frequency is controlled by a computer, which also register the introduced correction to keep the interrogation signal at its maximum. 13 1 The stability observed is σ ( τ ) = (5 ± 0.5) x10 τ, as presented in Figure 4, demonstrating that this y compact cold atom frequency standard can reach performances better than commercial beam clocks, which typically have short time stabilities on the range of 10-11 - 10-1. Figure. Ramsey Fringes obtained by an interrogation performed in the cavity by two microwave pulses of 1 ms each and separated by 8 ms. The linewidth of the central fringe is 47 Hz. Figure 3. Scan over the central Ramsey fringe (figure ) giving a 47 Hz linewith with 80% contrast. The advantage of cold atoms in such compact system can be easily observed if compared with commercial thermal Cs beam clocks. The long term stability already surpasses the currently used commercial standards and the clock transition linewidth is on the order of 50 Hz for our system, meanwhile the same resolution can be achieved only with a thermal system that has some meters in the interrogation region ( Hz for a 4 m long interrogation region [8]). 3

VII Brazilian Congress on Metrology (Metrologia 013) Journal of Physics: Conference Series 575 (015) 01030 Figure 4. Frequency stability of the system phase locked to a Hydrogen maser calculated by Allan standard deviation. 4. Reducing the system volume We actually envisage a more compact system, mounting the apparatus in a single block. This should be done keeping all the necessary processes to produce a frequency standard signal. 4.1. The macroscopic oscillator A fundamental piece of the atomic standard, it corresponds to the signal that generates the time reference. The feedback from the atoms interrogated with its signal closes the loop for the atomic frequency reference. It should be as small as possible, but still taking into account some parameters as temperature deviations [9, 10]. To achieve reliable performance, we will use PID (Proportional-Integral- Derivative) control and peltier elements as actuators. 4.. Lasers Diode The use of laser diodes is fundamental in the system. They should keep a very low effective linewidth, in order to not degrade the SNR of the clock transition. In the limit of high resolution spectroscopy, the laser noise can add a significant parcel to the overall budget of noise contributions. 4.3. General Control of the System Careful control of all the steps of the clockwork (trap, sub-doppler cooling, interrogation and detection) is mandatory. In each cycle the microwave source is corrected, and the steps consist of well synchronized events, such as laser light frequency shifts, pulsing of the microwave signal, triggered signal detection and processing of the atomic fluorescence [11]. 5. Conclusions We have developed a compact system to be used as a mobile reference for frequency signals. We managed to cool 10 8 atoms at 10 μk in a microwave cavity and after the Ramsey interrogation the detection by fluorescence is applied. The core idea is the use of cold atoms as a high performance and reliable clock source. We have been working in the reduction of volume to make an embeddable prototype, in order to maintain the high quality characteristics necessary for the operation of such device. References [1] Jespersen J and Fitz-Randolph J 1999 From sundials to atomic clocks (Mineola: Dover Publications) 4

VII Brazilian Congress on Metrology (Metrologia 013) Journal of Physics: Conference Series 575 (015) 01030 [] Ramsey N F 00 Application of atomic clocks in: Laser physics at the limits, ed Figger H. et al (Berlin: Springer) p 3 [3] Ahmed M, Magalhães D V, Bebeachibuli A, Müller S T, Alves R F, Ortega T A, Weiner J and Bagnato V S 008 The brazilian time and frequency atomic standards program An Acad Bras Cienc 80, [4] Magalhães D V 004 Construção de uma fountain atômica para utilização como padrão primário de tempo Doctorade thesis [5] Müller S T, Magalhães D V, Alves R F and Bagnato V S 011 Compact Frequency Standard based on an Intracavity Sample of Cold Cesium Atoms J. Opt. Soc. Am. B 8 11 p 59 [] Metcalf H and Van Der Straten P 003 Laser cooling and trapping of atoms J.Opt. Soc. Am. B 0 p 887 [7] Vanier J, Audoin C 1989 The quantum physics of atomic frequency standards v (Adam Hilger) [8] Glaze D J, Hellwig H, Allan D W and S. Jarvis 1977 NBS-4 and NBS-: The NBS primary frequency standards Metrologia 13 p 17-8 [9] L. E. Schnurr 197 The transient thermal characteristics of quartz resonators and their relation to temperature-frequency curve distortion 1 st Annual Symposium on Frequency Control (197) [10] Ji Wang, Yook-Kong Yong and Tsutomu Imai 1998 High-order plate theory based finite element analysis of the frequency-temperature relations of quartz crystal oscillators Frequency Control Symposium Proceedings of the 1998 IEEE International (1998) [11] J. Levine 1999 Introduction to time and frequency metrology Review of scientific instruments 70, 5