Temporal analysis for implicit compensation of local variations of emission coefficient applied for laser induced crack checking

Similar documents
Detection of Subsurface Defects using Active Infrared Thermography

In-Line Inspection of Hot-Rolled Steel Billets by Heat Flux Thermography

Analysis algorithm for surface crack detection by thermography with UV light excitation

Defect detection with thermal imaging and phase shifting methods in lock-in thermography

CHARACTERIZING CRACKS WITH ACTIVE THERMOGRAPHY

Lock-in Thermography on Electronic Devices Using Spatial Deconvolution

Aspect Ratio Considerations for Flat Bottom Hole Defects in Active Thermography

ACTIVE THERMOGRAPHY FOR MATERIALS NON-DESTRUCTIVE TESTING

Analysis of Thermal Diffusivity of Metals using Lock-in Thermography

Surface crack detection using infrared thermography and ultraviolet excitation

ACOUSTIC EMISSION SOURCE DETECTION USING THE TIME REVERSAL PRINCIPLE ON DISPERSIVE WAVES IN BEAMS

BOWSER Balloon Observatory for Wavelength and Spectral Emission Readings

Combined Acoustic Emission and Thermographic Testing of Fibre Composites

* Institut für Kunststofftechnik, University of Stuttgart, Pfaffenwaldring 32, Stuttgart, Germany,

LASER SPOT THERMOGRAPHY FOR CRACK DETECTION IN ALUMINUM STRUCTURES

QIPCam demo report. January 11 th 2013, Cédric Bravo. Table of Contents. 1 Goal of the demonstration

MEASUREMENT OF THERMAL STRESS AND PREDICTION OF FATIGUE FOR STS USING LOCK-IN THERMOGRAPHY

Inverse Heat Flux Evaluation using Conjugate Gradient Methods from Infrared Imaging

Exam 3--PHYS 202--S10

by M. Susa *, H. Benitez**, C. Ibarra-Castanedo *, H. Loaiza**, A. Bendada, X. Maldague*

PROCESS CONTROL BASIS FOR A COST-EFFECTIVE SELECTIVE SOLDERING PROCESS

Lecture 7: Edge Detection

Lecture 8: Interest Point Detection. Saad J Bedros

The wavelength reconstruction from toroidal spectrometer image data

Thermal Simulation of the Automated Fiber Placement Process and its Validation

Physics 30: Chapter 5 Exam Wave Nature of Light

Machine Positioning Uncertainty with Laser Interferometer Feedback

Transiting Exoplanet in the Near Infra-red for the XO-3 System

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

Feasibility of Die Attach testing

Optical Properties of Thin Semiconductor Films

Introduction to Infrared Thermometry

Feature extraction: Corners and blobs

Pulsed IR Thermography for Package Applications

Thermal Resistance Measurement

Reflow Soldering Processes Development Using Infrared Thermography

Thermal Parameter Measurement AN 18

Defect detection in ceramic materials by quantitative infrared thermography. by G. M. Revel* and S.

EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 9 Solutions. Due April 29th, 2013

Templates, Image Pyramids, and Filter Banks

A SELF-CALIBRATING EDDY-CURRENT INSTRUMENT

PH2200 Practice Final Exam Summer 2003

PROPERTY STUDY ON EMATS WITH VISUALIZATION OF ULTRASONIC PROPAGATION

Edges and Scale. Image Features. Detecting edges. Origin of Edges. Solution: smooth first. Effects of noise

Sensing and Sensors: Fundamental Concepts

Electromagnetic Waves A.K.A. Light

Resistance Post-Trim Drift Index for Film Resistors to be Trimmed Abstract Introduction

In Situ Imaging of Cold Atomic Gases

FSA TM Multi-bit Digital Processors

Analyzing Spiral Galaxies Observed in Near-Infrared

Mixing in Colliding, Ultrasonically Levitated Drops

Filtering and Edge Detection

Lecture 8: Interest Point Detection. Saad J Bedros

Exoplanets Direct imaging. Direct method of exoplanet detection. Direct imaging: observational challenges

Thermal behavior study of the mold surface in HPDC process by infrared thermography and comparison with simulation

Computer Modelling and Numerical Simulation of the Solid State Diode Pumped Nd 3+ :YAG Laser with Intracavity Saturable Absorber

Non-Destructive Inspection of Brazed Joint by Pulsed Phase Thermography

NICMOS Status and Plans

Image enhancement. Why image enhancement? Why image enhancement? Why image enhancement? Example of artifacts caused by image encoding

High-Speed Switching of IR-LEDs (Part I) Background and Datasheet Definition

Cloud analysis from METEOSAT data using image segmentation for climate model verification

Strain Measurement Techniques for Composite Coupon Testing

Unsteady-state lock-in thermography Application to shunts in solar cells

Crack Detection of Ceramics based on Laser Speckle Photometry

Compensation-based non-destructive automatic quality control using acoustic methods

The Effects of Noise and Time Delay on RWM Feedback System Performance

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

Eddy Current Thermography: Advances in NDT Fusion Technology for Future Industrial Application

Automatic Differential Lift-Off Compensation (AD-LOC) Method In Pulsed Eddy Current Inspection

Empirical Mean and Variance!

Nonlinear Losses in Electro-acoustical Transducers Wolfgang Klippel, Daniel Knobloch

Detectability of pulsed infrared thermography of delaminations in carbon fiber composites

Erkut Erdem. Hacettepe University February 24 th, Linear Diffusion 1. 2 Appendix - The Calculus of Variations 5.

Carlson CR Robotic/Reflectorless Total Station

Emissivity: Understanding the difference between apparent and actual infrared temperatures

Observation of shear-wave splitting from microseismicity induced by hydraulic fracturing: A non-vti story

Pulse Compression with Gaussian Weighted Chirp Modulated Excitation for Infrared Thermal Wave Imaging

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

Quantification by Signal to Noise Ratio of Active Infrared Thermography Data Processing Techniques

Thermocouple Dynamic Errors Correction for Instantaneous Temperature Measurements in Induction Heating. Krzysztof Konopka 1

Simultaneous Shearographic and Thermographic NDT of Aerospace materials

Commissioning of the Hanle Autoguider

Neutron activation analysis. Contents. Introduction

Damage Identification in Wind Turbine Blades

Kjersti Aas Line Eikvil Otto Milvang. Norwegian Computing Center, P.O. Box 114 Blindern, N-0314 Oslo, Norway. sharp reexes was a challenge. machine.

QUADRATIC FREQUENCY MODULATED THERMAL WAVE IMAGING FOR NON-DESTRUCTIVE TESTING. Ropar, Nangal Road, Rupnagar, Punjab , India

Orientation Map Based Palmprint Recognition

Numerical method of active thermography for the reconstruction of back wall geometry

H2 Physics Set A Paper 3 H2 PHYSICS. Exam papers with worked solutions. (Selected from Top JC) SET A PAPER 3.

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

What can laser light do for (or to) me?

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

A Recognition System for 3D Embossed Digits on Non-Smooth Metallic Surface

Numerical Modeling of the Thermal Behavior of Corrosion on Reinforced Concrete

Thermal Imaging at Multiple Time Instants for Study of Self-Heating and ESD Phenomena

Temperature Measurement of Plastic Injection Molding Dies

Multi-Sensor Fusion for Localization of a Mobile Robot in Outdoor Environments

Fig. 1. Schema of a chip and a LED

ROBUST VIRTUAL DYNAMIC STRAIN SENSORS FROM ACCELERATION MEASUREMENTS

Experimental confirmation of the negentropic character of the diffraction polarization of diffuse radiation

Transcription:

More Info at Open Access Database www.ndt.net/?id=17661 Abstract Temporal analysis for implicit compensation of local variations of emission coefficient applied for laser induced crack checking by G. Traxler*, P. Thanner*, G. Mahler** * PROFACTOR GmbH, Machine Vision, A-1150 Vienna, Austria, gerhard.traxler@profactor.at ** InfraTec GmbH, D-01217 Dresden, Germany, g.mahler@infratec.de This paper presents a new method using implicit compensation of local emission coefficients variations for thermographic inspection. Especially for inspection of metallic sample parts, which commonly have low emission coefficients, temporal signal analysis allows the compensation of disturbing influences caused by emission and reflection. An amplitude independent evaluation method of temporal analysis will be described. Results achieved by using different excitation methods such as laser spot and laser line are presented and compared with results from standard evaluation methods such as gradient evaluation. Additional, experimental setup will be depicted together with results from tests with several metallic sample parts. Introduction Laser induced heat flux thermography is a well-known method used for automatic crack checking solutions. In case of the inspection of metal parts thermographic systems have to deal with low and locally different emission coefficient values. These variations of the emission coefficient cause signal distortions which challenge automatic evaluation methods, especially when the parts to be inspected are of a complex geometry and vary in surface treatment. State of the art evaluation methods which are used for crack detection are often based on local gradient values[ 1 ] with hot spot identification. The gradient method calculates pixelwise local orthogonal gradients, using for example a 3x3 filter kernel and transposes the results into amplitude and direction values which can be represented as images. This method suffers from the problem that signals and distortions will be amplified. This means that in many cases these methods provide no or insufficient information for reliable discrimination between signals caused by cracks and pseudo signals generated by emission coefficient variations. This new approach evaluates not only the spatial information but also the temporal behavior of thermal signals. Due to its intrinsic noise suppression the proposed temporal analysis method is expected to provide more accurate crack detection results. Results calculated from both methods gradient and temporal evaluation will be compared and their robustness will be determined. Temporal Analysis The temporal analysis method focuses on the evaluation of temperature over time. The algorithm analyses the whole sequence of thermal images pixel by pixel in order to get the temporal temperature development for each single pixel. Within each of these temporal temperature profiles the moment of maximum amplitude is identified. The method of measuring time of maximum temperature at a distant position from the heating zone is known in context of thermal diffusivity measurement[ 2 ], but will be used here to compensate the disturbing influence of local emissivity. Starting with the begin of laser heating, heat flows into the surrounding material. Depending on the distance between laser spot center position and the point to be considered the maximum temperature is reached at different moments. In a simple case of a point source, the temperature distribution is given by a so called fundamental solution of the thermal diffusion equation[3]: T Q 2 c 4 t P r,t 3 2 With x[m] as distance from the point source, t[s] as time, starting at 0s with the source puls, Q[J] as source energy, [kg/m³] as density, c p [J/kg/K] as the specific heat capacity and [m²/s] as thermal diffusivity the temperature field is defined. In the real application the laser is switched on for a short finite duration, but the characteristic at locations distant to the laser is the same as described in (1). However, care must be taken, if laser-on duration gets into the order of signal maximum time, or if the observed distance gets into the order of the spot size. Fig. 1 shows typical temporal signal evolution at distances of 2.5, 3.0, 4.0 and 7.0 mm from the position of laser excitation. In this example the signal e 2 x 4 t (1)

maxima are reached between 257 and 2020ms after excitation. These signals show two effects. First, the bigger the distances the longer it takes until the maximum value is reached. And second, the bigger the distances the smaller the signal amplitudes are. T [K] 2.5 2 1.5 1 x=2.5mm t(t max )=257ms x=3mm t(t max )=370ms x=4mm t(t max )=658ms x=7mm t(t max )=2.02s 0.5 Fig. 1. Temporal evolution at different distances to center point source A crack causes changes within the heat flux. In metal parts a crack acts as a heat barrier which leads to delayed temperature evolution behind the crack. Using the temporal analysis method each pixel is represented by its time at which signal maximum is reached. Using a linear fit with a proper smoothing function increases the robustness. This is especially important for more distant and therefore low amplitude points. Based on this data cracks can be identified. Emission coefficient variation as well as reflections from the environment interferes with the amplitude of the thermal signal. The emission coefficient acts as a multiplicative factor which we assume to be constant for each pixel during the time period of thermogram sequence. Although this statement may not be true under all circumstances, but in case of metals, which is the most important application for crack detection, within a temperature range from 20 C to 100 C the error is insignificant. Reflections from ambient radiation act as additive offset to the thermal signal. As long as ambient conditions are constant for capturing period these disturbances are eliminated when using temporal analysis. Setup 0 10-1 10 0 10 1 The hardware components consist of a 100W CO 2 laser source, a high resolution thermal camera, a processing unit, a robot for positioning the test part to the inspection position and the test part itself. The specific parameters of the laser depend on the thermodynamic properties of the test sample. In this specific case the laser works with a spot diameter of 0.3mm and pulse duration of some 1/10 seconds. Once the testing sample has been positioned, the laser is switched on and the thermal camera captures 300..500 images with a frame rate of 200Hz. The thermal sequence was evaluated offline by a Matlab program. laser t [s] camera testing sample Fig. 2. Composition of main components Matlab is a registered trademark of Mathworks

The laser includes a deflection unit, which controls the position of the laser spot. The spot can be moved with up to 10m/s to form a heating line. In case of short lines with length of approximately 20mm, as used in the experiments, it takes the spot a little more than 2ms to move from one end of the heating line to the other. Due to a short integration time t=1..2ms of the camera, the spot will be integrated to a, more or less, solid line. This is also true for the temperature profile in the testing sample, because heat induced by the laser spot won t be distributed over more than 0.3mm in one movement cycle of the laser. The laser power is the same in case of a spot, but in case of a line it is distributed along the line, and the radiant incidence is smaller. Therefore the temperature raise is smaller in case of a line. For the experiment the laser power and the spot size were adjusted to avoid temperatures above 100 C at the surface of the testing sample. Experiment with a laser line As a first example a laser-line, approximately 1mm away from an artificial crack is used to heat up a testing steel sample having a medium emission coefficient of more than 0.6 and produced by casting. The shape of the laser spot-profile is close to a Gaussian distribution with a standard deviation of 0.3mm. Due to the periodical movement of the spot along a line with high frequency, done by a system of mirrors, the thermal image integrates the spot to a line, as shown in the left thermogram in Fig. 3. Fig. 3. Thermogram, taken immediately after switching the laser on (left) and after heat has distributed In the right thermogram in Fig. 3, taken after switching off the laser, heat has already distributed some mm away from the heating line. The artificial crack is a saw-cut with a depth of 1mm, as usually used in eddy current systems for testing and verification. It is orientated horizontally at image location y=130. Caused by the limited depth of the sawcut, heat flew not only around the crack, but also below it. According to the theory of heat conduction in solids a smooth distribution would be expected in the left thermogram, which is true in a macroscopic scale, but a closer look at the image shows some dark surface patches. They are not an effect of locally colder surface temperature, but an effect of a locally smaller emission coefficient. It suggests itself to calculate the absolute value of the local gradient g xy, (2) for evaluation of the crack. DL xy, shown in Fig. 4. g xy, 2 2 ddl x, y ddl x, y dx dy is the digital level of the pixel at location (x, y), with x and y in units of pixel-position. The result of (2) is (2)

Fig. 4. Gradient-image of thermogram It is remarkable, that gradient amplitude has almost the same value for the crack and the local distortions caused by the emissivity. In automated evaluation, for instance by threshold and segmentation positive false results will be the consequence. In this special case some filtering could improve robustness of evaluation, but assuming that we plan to detect shorter cracks too, filtering wouldn't help anymore. Evaluation of the entire sequence for the duration of cooling down neither would help. One could take the mean value of the single gradient image sequence to reduce noise, but the effect of local emissivity wouldn't vanish, because of its non-statistical characteristic. As stated in chapter "Temporal analysis", the influence of local emissivity should be neutralized, if time of maximum signal amplitude is calculated. Fig. 5 is showing two examples for signal evolution, one at a location 20 pixel away from the laser line (left diagram), and the other for a location 75 pixel away from laser line. 1000 pixelevolution at position x=24 y=151 60 pixelevolution at position x=20 y=95 800 50 digital value [DV] 600 400 200 digital value [DV] 40 30 20 10 0 0-200 0 100 200 300 400 500 imagenummer -10 0 100 200 300 400 500 imagenummer Fig. 5. Signal evolution at closer (left) and more distant (right) location For improvement of stability some filters were applied to the signal. A median with a length of 15 to eliminate outliers, and additionally smoothing was done by averaging. The original signal in Fig. 5 is represented by the thin line, and the filtered one by the thick line. Next, the time of the global maximum amplitude is calculated. Applying this procedure to each pixel results in an image of maximum time (Fig. 6, left image), or like done here in an image of image numbers, which is just another unit for time. Fig. 6. Image of image numbers for local maximum temperature (left) and gradient image (right)

For discussion and comparison the temporal image is converted into a gradient image (Fig. 6, right image). The crack at location y=130 is of high amplitude and continuous. Compared to the result of the pure gradient method, in which the crack seems to vanish at the right side, it stays strong after temporal evaluation. As expected no artifacts from local emissivity occur in temporal evolution, but other abnormalities, like a kind of outline-region around the laser line and an additional bright line at y=30, appear. The bright line is simply the limit, at which no maximum time can be calculated anymore, because the location is too far away from the laser to find temperature differences. Even below that limit, in the region y=30..80 the image numbers are saturated at the largest number of the thermal sequence. From evaluations point of view it means, that temperature didn't reach its maximum inside of acquisition time. Therefore it is a restriction for the size of the area around the laser which can be evaluated. Please note, that from this information the dimension of checked area might be calculated. If projected onto the surface of the testing sample it can be used to verify, if the entire surface has been checked without voids. Further it could be sent to the controlling unit of the checking machine to calculate the next checking location preventing some gaps. Both aspects are important for automated checking, and not contained in the non-temporal method. On the other hand the brighter region around the laser impedes evaluation of cracks. We therefore propose to apply some distance dependent weighting, in order to give values farer away from the laser less importance. Experiment with a laser spot Another experiment was done with a semiconductor laser spot of 50W, a profiles standard deviation of 0.5mm and with a wavelength of 810nm. A thermal sequence of 300 images of a cast iron part with a natural crack was taken for evaluation. Fig. 7. Gradient method (left) and gradient after temporal evaluation (right) Fig. 7 shows the results of gradient- and temporal method. Both do not show satisfying quality for automated evaluation, even if the crack is recognizable by the viewer (between arrows). The reason for the low quality is a highly reflecting surface of the testing sample, and in consequence a low temperature raise in the laser spot. In case of temporal evaluation the sequence is too short. The crack is located at the position of the outline of the evaluable area, and there is no temperature raise outside this area. To solve this problem a longer sequence would have to be acquired, but this example, which of course was done with worse parameters, is pointing out an important restriction, when applying the temporal method. Experiment with complex geometry Next experimental tests were performed on a highly reflecting steel tube with periodically smoothly alternating diameters in the range from 28 to 34 mm as sample part. The crack within the tube is straight, has a length of approximately 1.5mm and is a natural one, generated in a welding process. The thermogram sequence has been captured at 50Hz, and a laser spot with 0.3mm of standard deviation was deflected by a mirror system to form a straight line.

Fig. 8. Temperature distribution immediately after laser was switched off Even if a straight laser line was projected onto the surface of the testing sample it looks like a sine-wave in the thermogram (Fig. 8). It is caused by the 3-dimensional surface and the angle between laser and camera, which is approximately 45. This effect is very familiar to a laser-triangulation for distance measurement, and in turn, the composition of laser, camera and testing sample is exactly the same. Fig. 9. Thermogram after heat has distributed (left) and gradient (right) In the thermogram in Fig. 9 a lot of small areas with low emissivity can be identified by local dark spots, and a lot of abnormalities in the gradient image are the consequence. In this case filtering isn t able to solve the problem, because of the crack, marked by the arrows being small in relation to the errors caused by locally low emissivity. Some of the abnormalities are not caused by local emissivity, but by the surface structure at locations where it is not flat or rather at locations, which look like edges in the cameras view. The amplitude of this edge-signal is smaller than the one caused by emissivity, but higher amplitudes can be assumed in case of sharper edges. Fig. 10. Temporal evaluation (left) and gradient of temporal evaluation (right)

In the temporal evaluation in Fig. 10 neither effects of low emissivity spots, nor effects of edges can be recognized. The crack is not distorted by the perspectival distortion. It has high amplitude and a sharp outline. Disadvantageously two lines at the location of the right and left end of the laser line could complicate identification of cracks. This effect has to be solved by masking out the two regions. Conclusions The effect of locally varying emissivity has successfully been suppressed by temporal method. Further the checkable area can be derived from data, already existing from evaluation, even if there is no crack present. Some restrictions could be identified as limitation of the method as they are: - Observation time must be long enough to avoid additional clipping of the evaluable area. - Artifacts occur at the ends of the laser line. - In regions of lower amplitude, there is some remainder in the gradient image, which could complicate identification of cracks. - For a robust identification, weighting of evaluated data in order to enhance data near the laser spot and to decrease data farer away from it, seems to be necessary. Omitting the advantage of getting the checkable area, results of gradient and temporal method delivers comparable results for laser induced crack checking, if the surface of the testing sample has a high and homogeneous emissivity. Otherwise the temporal method is proposed to avoid problems caused by inhomogeneous emissivity. Outlook Some improvement could be possible by comparison of profiles from temporal evaluation with a fitted polynomial of second order, since profiles are expected to have the characteristic of a parabola. Acknowledgment This work was supported by the European Commission in the 7th Framework program under grant No. 284607, project ThermoBot. References 1 B.O.Tranta, Thermoinductive investigations of magnetic materials for surface cracks, Quantitative InfraRed Thermography Journal, Vol.1 Issue 1, 2004 2 Infrared Methodology and Technology, 1994, ISBN 2-88124-590-0, p153, V.P.Vavilov 3 H.S.Carslaw, J.C.Jaeger, Conduction of Heat in Solids, 2nd Edition 1959, Oxford University Press, ISBN 0-19- 853368-3, p256