Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Similar documents
Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

ICP-MS. High Resolution ICP-MS.

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Finnigan LCQ Advantage MAX

Agilent 7500 Series ICP-MS

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Thermo Finnigan LTQ. Specifications

Agilent 7700 Series. The Smallest, Most Powerful ICP MS Ever Made

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Agilent G2350A Atomic Emission Detector (AED)

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Agilent 8800 ICP-QQQ

The New Agilent 7700 Series ICP-MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Agilent 8900 Triple Quadrupole ICP-MS

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Robust ICP-MS with ease of use and high productivity for routine laboratories

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Product Descriptions and Offerings

Redefining triple quadrupole technology with unique ease of use

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Extrel is widely respected for the quality of mass spectrometer systems that are

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

473 Dew Point Hygrometer

TOXICOLOGY & FORENSIC APPLICATIONS

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Agilent 8900 Triple Quadrupole ICP-MS LEAVE INTERFERENCES BEHIND WITH MS/MS

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

OES - Optical Emission Spectrometer 2000

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

Defining quality standards for the analysis of solid samples

110 Lowell Rd Hudson, NH USA Tel:

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Capillary Electrophoresis Gas Chromatography

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Atomic Spectroscopy AA/ICP/ICPMS:

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

novaa 800 D Atomic Absorption Spectrometer

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

ICP-MS. Inductively Coupled Plasma Mass Spectrometry. A Primer

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Agilent 5977A Series GC/MSD System

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

473 Dew Point Hygrometer

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

LIBSlab ANALYZERS ANALYZERS

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry: acquiring basic skills and solid sample meausurements

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Thermo Scientific TSQ Quantum Ultra Ultra AM/Ultra EMR Performance Specifications

AutoChem II 2920 A Catalyst Characterization Laboratory

Fergus Keenan Shona McSheehy Julian Wills

Introduction to the Q Trap LC/MS/MS System

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Analysis of domestic sludge using the Agilent 4200 MP-AES

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Samples compliant with the WATER

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Catalysis CAPABILITIES

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Agilent Technologies at TIAFT 2013

Optimizing Analytical Performance in ICP-OES Applications

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

OptiMass 9500 ICP-oTOFMS. Orthogonal Time-Of-Flight The World s Fastest Benchtop ICP Mass Spectrometer. SCIENTIFIC EQUIPMENT

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

473-SHX Dew Point Mirror

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Transcription:

www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent 7500a ICP-MS is a full-featured high-performance benchtop instrument for the routine determination of metals in a wide variety of sample types. Advanced design and extensive testing has produced an extremely rugged unit capable of generating highquality data even in a non-ideal laboratory environment. The Agilent 7500a is the ideal product for laboratories looking to replace ICP-OES instruments. Incorporating an industry standard 27.12 MKz ICP RF generator and four independent computer-controlled mass-flow controllers for ICP gas control, the Agilent 7500a offers a tremendous level of sample introduction flexibility. In addition, the computer-controlled torch position (in all three axes) and comprehensive auto-tuning routines ensure that system setup is consistent, regardless of operator expertise. The Agilent 7500 Series of ICP-MS instruments delivers the lowest level of matrix-based polyatomic interferences of any commercial ICP-MS system, ensuring data quality even for the high-matrix samples frequently encountered in environmental, geological, clinical, and foods. The Agilent 7500 Series also features nine orders of linear dynamic range and a true simultaneous dual-mode detector with a new, high-speed log amplifier. The unique amplifier design allows the system to acquire data at the same high speed, whether analyzing in pulse counting or extended dynamic range. The new detector makes the Agilent 7500 Series a very powerful tool for fast, transient, signal measurement (with chromatographic or laser ablation analysis, for example). The new Agilent 7500a features the ShieldTorch System, which dramatically increases sensitivity across the full mass range. The ShieldTorch also enables cool plasma operation for the removal of polyatomic interferences on K, Ca, and Fe, and carbon-based interferences in organics. A wide range of optimal accessories enhances the system flexibility of Agilent 7500a. The Integrated Sample Introduction System (ISIS) is a powerful tool for increasing sample throughput or automating manual tasks such as sample dilution. The Agilent GC interface is the first commercially available interface enabling GC-ICP-MS analysis. Add the Agilent Technologies Plasma Chromatographic software, and the 7500a becomes a very powerful solution for speciation analysis.

Should user requirements change, the 7500a can be upgraded easily onsite with reaction cell technology. The Agilent 7500a ICP-MS features: Compact, benchtop design Durable, stainless steel chassis Open architecture sample introduction area for ease of use Peltier-cooled sample introduction system ShieldTorch System offering high sensitivity mode and cool plasma operation Four computer-controlled mass-flow controllers for optimum stability Automatic, computer-controlled torch alignment for consistent performance Robust 27 MHz solid state RF generator Innovative interface design featuring dual extraction lenses Omega II off-axis lens system True hyperbolic quadrupole cross-section rods Digitally synthesized 3 MHz, high-frequency RF generator Simultaneous Dual Mode detector with an exclusive high-speed amplifier providing nine orders of linear dynamic range Upgradeable onsite to reaction cell technology DIMENSIONS AND WEIGHT Mainframe (W x D x H) Weight 1100 x 600 x 640 mm 175 kg (386 lb) Not including PC, printer and rotary pump HARDWARE Nebulizer Spray chamber Interface Four mass-flow controllers Fifth mass-flow controller ShieldTorch system ICP source Vacuum system Ion optics Quadrupole Quadrupole radio frequency Data acquisition Minimum dwell time 100 µs Mass range 2-260 amu High solids type Thermoelectrically controlled Nickel cones Plasma, auxiliary, make-up and carrier gas lines Optional Standard 27.12 MHz solid state Three stage Omega II off-axis lens system True hyperbolic cross-section rods 3 MHz True simultaneous dual-mode electron multiplier with nine orders dynamic range

Rotary pump One SOFTWARE Operating system Autotuning Custom reporting Intelligent sequencing Microsoft Windows 2000/XP Included Included Optional not included PC CONFIGURATION Compact Evo D510 Small Form Factor Intel Pentium 4 2.4 GHz 512 MB RAM 40 GB Hard Drive 48x/ 12x/ 48x CD-RW drive Integrated Intel PRO/100 VM Network Connection 19-inch CRT (Optional 17-inch LCD) HP LaserJet 2200d Note: PC configuration is subject to change. UTILITY REQUIREMENTS Electrical Power Single phase 200-240 V, 30 A, 50/60 Hz COOLING WATER Inlet temperature 15-40 C Minimum flow rate 5 L/min Inlet Pressure 230-350 kpa (33-51 psi) ARGON GAS SUPPLY Minimum Purity 99.99% Maximum flow rate 20 L/ min Supply pressure 700 kpa (100 psi) ± 3.5%

EXHAUST DUCT Extraction flow rate 4-6 m 3 /min. (7-8 m 3 /min: with optional duct) ENVIRONMENTAL REQUIREMENTS Operating temperature Operating humidity 15-30 C < 2 C/h 20-80% (non-condensing) PERMORMANCE SPECIFICATIONS (NORMAL MODE) Sensitivity * Li (7) Y (89) TI (205) 8 Mcps/ ppm 20 Mcps/ ppm 12 Mcps/ ppm Background (5 amu)* 5 cps ** Oxide (Ce0 + ) * 1.0% Doubly Charged (Ce 2+ )* 3.0% ABUNDANCE SENSITIVITY Low Mass 1 x 10-6 High Mass 5 x 10-7 DETECTION LIMIT (3 sigma, 3 sec. integration) Be (9) In (115) Bi (209) 2 ppt 1 ppt 1 ppt Short Term Stability (RSD)* 3% (20 min) Long Term Stability (RSD) 4% (2 h) PERFORMANCE SPECIFICATIONS (High Sensitivity Mode)

Sensitivity Y (89) 200 Mcps/ ppm *All items so marked will be tested on-site under a single set of tuning conditions. ** Background as measured as mean counts, not standard deviation. REGULATORY COMPLIANCE Safety CSA-C22.2 No. 1010, UL 3101-1 Electromagnetic compatibility EN55011: 1992 Group 1 Class A EN50082-1: 1997 Agilent 7500 Series ICP-MS are manufactured at an ISO 9001 and ISO 14001 certified facility. Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment