Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz

Similar documents
Development of beam delivery systems for proton (ion) therapy

Status of the Siemens IONTRIS Particle Therapy Systems: Marburg, Kiel and Shanghai

Radiation protection issues in proton therapy

Accelerators for Hadrontherapy -- Present & Future --

TERA CONTRIBUTIONS TO PARTNER

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

Towards efficient and accurate particle transport simulation in medical applications

Beam Optics for a Scanned Proton Beam at Loma Linda University Medical Center

arxiv: v2 [physics.med-ph] 29 May 2015

Advanced Linac Solutions for Hadrontherapy

PARTICLE BEAMS, TOOLS FOR MODERN SCIENCE AND MEDICINE Hans-H. Braun, CERN

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy

THE mono-energetic hadron beam such as heavy-ions or

Particle Beam Technology and Delivery

CERN Medical Applications. Giovanni Porcellana. Medical Applications Officer. Knowledge Transfer Accelerating Innovation

Secondary Particles Produced by Hadron Therapy

Design of a proton therapy synchrotron. A Dosage Calculation Example

Introduction to Accelerator Physics Part 1

Introduction to Accelerator Physics Part 1

The heavy ion irradiation facility at KVI-CART

NIRS. Outline HIMAC. Introduction Gantry developments. Superconducting magnets Construction of gantry structure. Future project.

Proposal to convert TLS Booster for hadron accelerator

Radiation Shielding of a 230 MeV Proton Cyclotron For Cancer Therapy

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Small Synchrotrons. Michael Benedikt. CERN, AB-Department. CAS, Zeegse, 30/05/05 Small Synchrotrons M. Benedikt 1

A NOVEL DESIGN OF A CYCLOTRON BASED ACCELERATOR SYSTEM FOR MULTI-ION THERAPY

Markus Roth TU Darmstadt

Short Introduction to CLIC and CTF3, Technologies for Future Linear Colliders

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

SLS at the Paul Scherrer Institute (PSI), Villigen, Switzerland

Partikel terapi accelerator (Siemens)

Instrumentation for Verification of Dose

A Project to convert TLS Booster to hadron accelerator 1. Basic design. 2. The injection systems:

Best Particle Therapy, Inc. is Developing a Highly Revolutionary New Treatment for Cancer Therapy

Simulation Modeling in Dosimetry

Feasibility study of TULIP: a TUrning

Physics of Novel Radiation Modalities Particles and Isotopes. Todd Pawlicki, Ph.D. UC San Diego

Hadron Therapy Medical Applications

China high-intensity accelerator technology developments for Neutron Sources & ADS

Dielectric Wall Accelerator (DWA) and Distal Edge Tracking Proton Delivery System Rock Mackie Professor Dept of Medical Physics UW Madison Co-Founder

8/3/2016. Chia-Ho, Hua St. Jude Children's Research Hospital. Kevin Teo The Hospital of the University of Pennsylvania

Instrumentation for Verification of Dose

Spawning Neutrons, Protons, Electrons and Photons from Universities to Society

Electromagnetic characterization of big aperture magnet used in particle beam cancer therapy

Introduction to Medical Physics

HEATHER. HElium ion Acceleration for radiotherapy. Jordan Taylor, Rob Edgecock University of Huddersfield Carol Johnstone, Fermilab

Monte Carlo simulations of ripple filters designed for proton and carbon ion beams in hadrontherapy with active scanning technique

Radiation Shielding. PTCOG 57 Cincinnati, USA (2018)

Engines of Discovery

THE GSI FUTURE PROJECT: AN INTERNATIONAL ACCELERATOR FACILITY FOR BEAMS OF IONS AND ANTIPROTONS

S-Band side coupled drift tube linac

Heavy ion fusion energy program in Russia

Optimization of hadron therapy proton beam using Monte Carlo code on GPU

Fast and compact proton radiography imaging system for proton radiotherapy

Nuclear medicine and Radiation technologies

COMPARISON OF COMPUTER CODES APPLICABILITY IN SHIELDING DESIGN FOR HADRON THERAPY FACILITIES *

Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom

Carbon/proton therapy: A novel gantry design

Squeezing the proton. towards small proton therapy systems. Roelf Slopsema. M.Sc. / UF Health Proton Therapy Institute

Magnetic removal of electron contamination in radiotherapy x-ray beams

Cancer Treatment by Charged Particles - Carbon Ion Radiotherapy Part 2

Isotope Production for Nuclear Medicine

Introduction to Accelerator Physics

Estec final presentation days 2018

Shielding Design for the Imaging and Medical Beamline at the Australian Synchrotron

Low slice emittance preservation during bunch compression

Geant4 studies of the CNAO facility system for hadrontherapy treatment of uveal melanomas

Multi-Purpose Accelerator-Accumulator ITEP-TWAC for Nuclear Physics and Practical Applications

Radiation Shielding of Extraction Absorbers for a Fermilab Photoinjector

STATUS OF HIRFL-CSR PROJECT *

Statusreport. Status of the GSI accelerators for FRS operation. Jens Stadlmann (FAIR Synchrotrons)

Introduction to Medical Physics

Section 4 : Accelerators

Development of accelerator and detector systems for radiation medicine in DLNP JINR

MONTE CARLO SIMULATION FOR EVALUATION OF DOSE DISTRIBUTION IN PROTON THERAPY *

PULSE-TO-PULSE TRANSVERSE BEAM EMITTANCE CONTROLLING FOR MLF AND MR IN THE 3-GeV RCS OF J-PARC

Unconventional Acceleration Systems for Proton Radiotherapy

Bhas Bapat MOL-PH Seminar October Ion Matter Interactions and Applications

Simulations in Radiation Therapy

Biological Dose Calculations for Particle Therapy in FLUKA

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research

Chapter 10 Acceptance Tests and Commissioning Measurements

PHITS calculation of the radiation field in HIMAC BIO

Measurements of secondary particles emitted by 12 C, 4 He and 16 O ion beams in view of innovative dose profiling technique in Particle Therapy

Bulk shielding design for the MAX IV facility

3. Synchrotrons. Synchrotron Basics

Medical Applications of Particle Accelerators

Cyclinac Medical Accelerators Using Pulsed C 6+ /H 2

Metrological traceability and specific needs in: - IR measurement for radiation protection (RP) - IR measurement for radiotherapy (RT)

REVIEW OF COMPACT COMMERCIAL ACCELERATOR PRODUCTS AND APPLICATIONS

Il picco di Bragg. G. Battistoni INFN Milano. 08/06/2015 G. Battistoni

R&D of emulsion technology to study fragment interaction to improve ion therapy

A comparison of methods for monitoring photon beam energy constancy

X-band Experience at FEL

Development of the UNILAC towards a Megawatt Beam Injector

A diamond detector for Space Research and Therapy. Radek Pleskac (GSI Darmstadt)

OVERVIEW OF RECENT RFQ PROJECTS *

Spectral Correction Factors for Conventional Neutron Dose Meters Used in High-Energy Neutron Environments

Review of ISOL-type Radioactive Beam Facilities

Heuijin Lim, Manwoo Lee, Jungyu Yi, Sang Koo Kang, Me Young Kim, Dong Hyeok Jeong

Transcription:

Overview and Status of the Austrian Particle Therapy Facility MedAustron Peter Urschütz

MedAustron Centre for ion beam therapy and non-clinical research Treatment of 1200 patients/year in full operation Worldwide the 6 th combined centre for ion beam therapy with protons and carbon ions Founded in 2007 as EBG MedAustron GmbH in indirect ownership of the federal state of Lower Austria 2

Financing Investment volume: 200 million Financing partners: Republic of Austria Federal State of Lower Austria City of Wr. Neustadt 3

Location Wiener Neustadt, approx. 50 km southern of Vienna 40.000 inhabitants 4

Radiotherapy Accelerator type Conventional Radiotherapy Proton Therapy Ion Therapy Electron Linac Cyclotron Synchrotron Courtesy of Varian Courtesy of Varian Particle type Electrons, photons Protons Ions (protons, carbon ions) # Austria > 40 0 1 (2016) # World x000 ~ 45 6 (incl. MedAustron) 5

Ion beam therapy innovative form of radiotherapy Main benefit: protection of surrounding healthy tissue. Treatment of tumors next to organs at risk Huge benefit specially for kids. 6

Carbon ions differences compared to protons Higher and energy dependent LET Higher and energy dependent RBE Less scattering Lower dependency on the cell cycle Increased effectiveness in case of radiation resistant tumor (hypoxic tumors) Improved dose conformity Potentially lower fractionation scheme Increased fragmentation tail Less experience compared to protons Lower acceptance in the community 7

The MedAustron facility 8

Irradiation room configuration 9

Irradiation concept active energy selection -> penetration depth transverse pencil beam scanning online beam monitoring no patient specific passive devices! Courtesy of GSI 10

Source room Ion sources to produce protons or carbon ions Back-up source 11

Linear accelerator Pre-acceleration and beam shaping to meet injection conditions of synchrotron 12

The Injector Generation of protons and C 6+ Acceleration of beam to 7 MeV/u Generation of protons and C 6+ 7 MeV/u 0.4 MeV/u 8 kev/u El. Deflector Stripper foil (H 3 + to p, C 4+ to C 6+ ) 13

Synchrotron Beam from Injector (7 MeV/u) Beam to Patient Acceleration of beams to desired extraction energy Active energy selection: 255 selectable energy steps (steps of 1 2 mm) p: 60 250 MeV (NCR: 800 MeV) C: 120 400 MeV/u Ramp speed: 0.5 s to highest energy Extraction time: 1 10 s 14

The synchrotron Center-piece of the accelerator 15

Synchrotron Typical cycle for a synchrotron for medical use with slow extraction. Magnetic field B max B 1 B 2 Injection Extraction energy 1 Injection Extraction energy 2 Time Acceleration 2 s Acceleration 4 s Intensity Energy 1 Intensity 1 Energy 2 Intensity 2 Time Beam structure: pulsed, energy and intensity variable 16

Synchrotron hall 17

Extraction line guiding the beam into the 4 irradiation rooms 18

Scanning System Transverse pencil beam scanning: beam size: mm range (FWHM in vacuum) Fast magnetic deflection: scanning speed > 20 m/s One iso-energy slice irradiated with approx. one extracted beam pulse (spill of 1 10 s) horizontal deflection vertical deflection 19

Particle accelerator key figures developed in close cooperation with CERN more than 1.000 large components 220 manufacturers from 23 countries diameter of the synchrotron: 25 m more than 100 km of cables power consumption: 5 MW (approx. 10.000 households) 20

Beam parameters Particles protons, carbon ions Energy Clinical energies: p: 60-250 MeV; C6+: 120-400 MeV/u -> 3-37 (p)/ 27 (C) cm penetration depth in water IR1: clinical energies + up to 800 MeV for protons Intensity Per spill: 1 * 10 10 (p) / 4 * 10 8 (C) 4 different intensity levels Size 4 sizes: 4, 6, 8, 10 mm FWHM [in vacuum] Scanning field : 20x20 cm 2 (IR1-3), 12x20 cm 2 (IR4) Beam delivery precision < 0.5 mm 21

100.000 different beam combinations Accelerator is able to generate: 2 ion species 255 different energies 4 beam sizes 4 intensities 8 extraction lengths 65 280 Beam combinations per beam line Gantry: various angles need to be considered Non-clinical research: extended energy range huge amount of commissioning work Example for table to select a beam combination 22

Comparison Synchrotron - Cyclotron Energy: active energy selection vs. fixed energy (+ degrader) Radiation protection: small vs. large efforts Beam currents: low vs. high Ion species: multiple ions vs. protons only Footprint: large vs. small Cost: high vs. low Vendors: no commercial systems (Europe) vs. multiple vendors 23

The proton gantry rotating the beam 180 around the patient allows irradiation from various angles based on the PSI-2-Gantry, further developed by MedAustron total weight: 220 t swing diametre: 7,5 m precision: < 0,1 isocentre: < 0,3 mm 24

The proton gantry 25

Gantry treatment room 26

CE labelled medical product Ion Sources Linear Accelerator Synchrotron Beam Distribution Beam Outlet for Nonclinical Research & Engineering Applications Accelerator Control System (Main Control Room) A/B C D Power Supplies/Device Control Units (2.OG) Dose Delivery System Clinical Beamlines IR2: horizontal 1 (A) and vertical (B) Clinical Beamline IR3: horizontal 2 (C) Clinical Beamline IR4: Gantry Beamline (D) MAPTA Treatment Control Panel (Local Control Rooms 1 to 4) A/ B C D according to Medical Device Directive (MDD) 27

Irradiation room MAPTA Position Verification System (Ring Imaging System) Beam Line DDS Patient Positioning System Nozzle (incl. ripple filter, range shifter) Patient treatment is controlled and monitored by the Oncology Information System (OIS) 28

Robotic patient positioning system ceiling-mounted 7 degrees of freedom non-isocentric treatment tracking position of the bench with optical tracking system positioning accuracy: < 0.5 mm 29

Patient position verification system Flat panel and X-ray tube rotatable around the ring, couchmounted fast flat panel detector (30 Hz framerate) single source dual energy X-ray (60, 120 kv) large clearance (78 cm ring) 2D, 3D imaging cone beam CT 30

Patient positioning and verification system 31

MedAustron: project timeline and status 32

Construction 2011-2012 (18 months) 33

Construction 2011-2012 (18 months) 34

Oct 2012: Moving in 35

Accelerator installation 2013-2014 First beam in IR3 in Oct. 2014 36

Accelerator commissioning 2015 work in progress intensity, beam position and FWHM beam size over extracted spill measured in HEBT 37

Accelerator commissioning 2015 work in progress beam measured by detectors of dose delivery system 38

Penetration depth Particle energy successfully adjusted within a single iteration round. 39

Beam size measured at isocenter beam size and symmetry adjusted within a single iteration round. 40

Recent commissioning results 250 MeV Scanned Proton Beam FWHM x: 7.0 mm FWHM y: 7.0 mm

Recent commissioning results 250 MeV Scanned Proton Beam FWHM x: 7.0 mm FWHM y: 7.0 mm

Installation of vertical beam line Vertical beam line installed in Q4 2015 Beam commissioning in 2017 43

Remaining steps towards 1 st patient treatment Finalisation of the proton beam commissioning for horizontal fixed beam lines Fine tuning of beams Coverage of full parameter space (different energies, intensities, etc ) System integration (complete workflow) Interlock and error management Verification and validation test phase Technical documentation and regulatory aspects Medical physics: base data measurements (TPS) End to end tests 44

1 st patient treatment in 2016 2016: first patient treatment with protons (horizontal fixed beam lines) 2016: provide beams for non clinical research 2017 20: Commissioning of further beam lines, Carbon ions, Gantry enhance functionalities, performance increase 2020/21: full operation 45

Thank you for your attention!