TG MANUAL. OPEN SOURCE TIMING SOFTWARE. Oscillo-Escape. The first devices of this sort appeared around Let's say they were electronic devices.

Similar documents
PARTS CATALOGUE / TECHNICAL GUIDE

Technical Guide TG-19-C-001-E D. Produced by: rendav Date: Modifications: See last page CALIBRE 2500

PARTS LIST / TECHNICAL GUIDE

Reference number: Worksheet/Receipt. Owners name: - Telephone: Description of item(s) received, including accessories:

Reference 5204/1. Caliber CHR PS Q

Technical Guide TG-19-C-063-E A. Made by : rendav Date : CALIBRE Height on movement Power reserve Number of jewels Frequency

Technical Guide TG-19-C-045-E C. Made by: pelrom Date: Modifications: see last page CALIBRE 3301

Issue date: 30. Apr TECHNICAL GUIDE PARTS CATALOGUE. Cal.NH25/26 AUTOMATIC MECHANICAL. SII Products

Technical Guide TG-19-C-029-E E. Made by: rendav Date: Modifications: see last page CALIBRE 3303

BULOVA MODELS. Selfwinding and. Watches. Specifications 12EBA 12 EBAD 12 ECAD 12 EBACD 12 ECACD. . i -... ~.~.. '. Movement: Self-winding mechanism

Reference Caliber R TO 27 PS QI

Louis Moinet MAGISTRALIS

DOWNLOAD. Experience the magic of Customer Service and download the Zenith Watches - The Experience app!

DOWNLOAD. Experience the magic of Customer Service and download the Zenith Watches - The Experience app!

Winding the mainspring, adjusting the hand, day/date is done by the below procedure. day adjustment hand adjustment date adjustment

Maître Cabinotier retrograde armillary tourbillon


PARTS CATALOGUE / TECHNICAL GUIDE Cal. 4F32A, 8F32A Cal. 8F33A, 8F35A

The Mystery in the Design of A. R. Guilmet

mechanically regulated, hence making no use of electric, magnetic or electromagnetic means.

Operating manual for Air Commando automatic watch/ Calibers , , , 2892A2

MAIN FEATURES USER INSTRUCTIONS

XR Analog Clock - Manual Setting Model Troubleshooting Guide

In Association With. Introduces. TPT Contractor

A quartz watch is a watch that uses a movement powered by a quartz crystal to. Quartz crystals are very accurate.

BISHOP S CASTLE TOWN COUNCIL HEALTH AND SAFETY POLICY FOR CLOCK WINDING. Introduction

Elastic Properties of Solids Exercises I II for one weight Exercises III and IV give the second weight

Revised on : 06. Jun TECHNICAL GUIDE PARTS CATALOGUE. Cal.VD7Series (VD70/72/73/74/75/76/77/78/79A) ANALOGUE QUARTZ.

Revised on : 06. Jun TECHNICAL GUIDE PARTS CATALOGUE. Cal.VD8Series. (Cal.VD84/85/86/87/88A) ANALOGUE QUARTZ. SII Products

product manual H-3220A Benkelman Beam

OYSTER PERPETUAL SKY-DWELLER

Function Notation TEACHER NOTES MATH NSPIRED. Math Objectives. Vocabulary. About the Lesson. TI-Nspire Navigator System. Activity Materials

Installation and User Instructions

Clock Mainsprings. This is the formula to use to determine the correct mainspring length: 5/28/2013 Clock Mainsprings

2DI90 Probability & Statistics. 2DI90 Chapter 4 of MR

Elastic Properties of Solids (One or two weights)

REVOLUTION TO EVOLUTION

l Every object in a state of uniform motion tends to remain in that state of motion unless an

O P E R A T I N G M A N U A L

OYSTER PERPETUAL GMT-MASTER II

earthquake virtual

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

URWERK presents the EMC: The first high-end mechanical watch with artificial intelligence

29/05/2017. This thou must always bear in mind, what is the nature of the whole.. Look always at the whole. Marcus Aurelius, Philosopher and Emperor

THE AMC PROJECT A world first in the history of watchmaking

Page AC : INSTRUMENTATION FOR SHOCK AND IMPACT ANALYSIS

Data Sheet / Instructions. Dewpoint MeterO

OYSTER PERPETUAL COSMOGRAPH DAYTONA

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

The Coupled Pendulum Experiment

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department

Minute Impulse Clock Controller I01DN

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere

Please complete this form and enclose it with your carefully packed watch for repair. Add a check for postage and handling.

Minimum (-31) every 10 s -35 (-31)

Monitoring Radar Mechanical Drive Systems FAA's choice of monitoring solutions

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

Explanation: The factory restart returns the atomic clock to an out-of-the-box state and often resolves an issue.

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

User s Manual. Surface Potential Meter. Revision 1.0

Human Arm. 1 Purpose. 2 Theory. 2.1 Equation of Motion for a Rotating Rigid Body

Dewpoint Meter Data Sheet / Instructions

Impulse, Momentum, and Energy

Coulomb s Law Mini-Lab

Lab 7 Energy. What You Need To Know: Physics 225 Lab

Simple circuits - 3 hr

Sensor Accessories. Rotary Motion Accessory Pack. Pendulum Rod with two masses, Angular Momentum disc set and Linear Rack with mini c-clamp

Measuring ph with Smart Cuvettes

Wood and metal Metallica 1735 The new product line

MASTER CLOCKS 2407MLN1

PoleMaster User Manual (Northern Hemisphere)

BioMechanics and BioMaterials Lab (BME 541) Experiment #5 Mechanical Prosperities of Biomaterials Tensile Test

CSE370: Introduction to Digital Design

Double Inverted Pendulum (DBIP)

Analysis of the Lever Escapement, by H. R. Playtner

Calibration Routine. Store in HDD. Switch "Program Control" Ref 1/ Ref 2 Manual Automatic

An Analysis of the Lever Escapement

University of Colorado Denver Anschutz Medical Campus Online Chemical Inventory System User s Manual

Creation and modification of a geological model Program: Stratigraphy

Hey, that wasn t so hard. INSTRUCTION MANUAL AND WARRANTY

TECDIS and TELchart ECS Weather Overlay Guide


WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

Microsystems Technology Laboratories i-stepperthursday, October 27, 2005 / site map / contact

User's Manual altimeter V1.1

Well prepared - good results

TIphysics.com. Physics. Friction: Your Friend or Your Enemy? ID: By Irina Lyublinskaya

Physics 8 Wednesday, October 25, 2017

Quartz Crystal Nanobalance (QCN)

Operating the Celestron 14 Telescope

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

MAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS

Heat stress index. Dewpoint. pressure. altitude

Lasentec Product Group

Grade XI. Physics Exam Preparation Booklet. Chapter-wise Important Questions. #GrowWithGreen

Lightcloud Application

Transcription:

TG MANUAL. OPEN SOURCE TIMING SOFTWARE. Oscillo-Escape The origin of the watch timing machine. We call a "timing machine" a device that allows, in its most basic function, to determine the performance of a mechanical or electromechanical clock, and to establish the gaining or losing rate at a given moment. Here we have a patent register of one of these devices or devices. Https://www.google.com/patents/US2155646 The first devices of this sort appeared around 1935. Let's say they were electronic devices. There were several manufacturers including American and European. Its principle has been the same. A stable and known standard is used as a reference and is used to determine the deviation of a mechanical watch. With respect to tg Timing Software, the software designer uses the hardware of a processor or computer and has created a program with advanced algorithms that allow not only to determine the deviation of the march, that is to say it s the gaining or losing rate, but also other important parameters In the analysis of a mechanical watch. These are the "Beat Error", and "the amplitude of the balance wheel". What is tg Open source timing software? TG Timing Sofware is an application designed to help watchmakers, determine the state and performance of a mechanical watch that has the Swiss Lever anchor system as an escape design, but can easily determine the operation of other types of escapement like the escapement type Roskopf. https://en.wikipedia.org/wiki/pin-pallet_escapement What do you need to work on tg Timing Software? A computer or computer. A microphone or vibration sensor A preamplifier Basic knowledge of watchmaking. COMPUTER The computer can be a hardware of about 10 years old. We have worked with Windows 7, Windows 8, and Windows 10. It is certain that most computers around 5 years old will work in an acceptable way. THE MICROPHONE.

This is the part where there is usually a bit of difficulty. The tg software is extremely efficient even when working with conventional microphones. However given the characteristics of the clock sound, a relatively clean sound with low noise and interference levels is important. We suggest using a pickup microphone for electroacoustic guitar on ebay or Amazon. The only thing that should be done with the clip is to remove the rubber pad because if it is not done, it works like a low pass filter and that would be counterproductive as it is necessary to eliminate the low frequencies and to maintain the highs, where is the greater information of the sound of the watch. The following link provides important information on this particular. See the link here. And download the pdf doc. http://www.iaeng.org/publication/wce2007/wce2007_pp624-629.pdf THE PREAMPLIFIER The tg software is designed to get the sound of a watch from overly specialized mics. However we have verified that using a pre-amplifier gives a signal of better quality. The microphone can be used directly in the microphone input of the computer but the signal will have a considerable amount of noise. By integrating the pre-amplifier to the line, the result can be optimal. We have used with very satisfactory results the pre-amplifier the Mini Phono Preamp PYLE Model PP444. Here is a link on the modification made to the preamplifier. http://reparacionderelojes.weebly.com/modificacioacuten-de-pyle-pp440.html However we have checked that the pre-amplifier works without any modification for the tg software. ABOUT THE INSTALLATION. You only need to download zip files from this link. https://tg.ciovil.li/ If you are a user of Windows 7 or higher, use the link: "Microsoft Windows installer (7 and above)" This will download the windows installer and will create in the programs two shortcuts Tg 0.4.0 and Tg lt 0.4.0. The tg-lt file seems to have less memory demand, but processor demand is kept high.

THE SCREEN AND THE FIELDS. 1 2 7 5 6 5 3 4 LIST OF EXPLANATION OF THE FIELDS 1.- BPH (Beat Per Hour) information window The program can automatically choose any value between 12000 and 72000 BPH. It can also be chosen manually. (Warning) From version 0.3.1, if you change it manually, this will be the next time the program is opened, you can leave it in "Guess", is automatic. 2. "Lift Angle" window. This value must be set by the user. Most watch movements have a value set by the manufacturer or movement designer. This value is used by the program to determine the Amplitude Balance Wheel. It will not affect the value of the gaining or losing rate, nor will the beat error value. But it will affect the Amplitude result. 52 degrees is an average value. Here a link with movements and their respective angle of elevation. See the link. http://longines30l.com/wordpress/?page_id=597 3. Window 3 is a "Paper Strip" emulator. It simulates a strip of paper, as in the old models of Timing machines, in which the successive points that indicated the clock record were printed. In the graph that we have of example we see that the succession of points is not vertical but has an inclination. To the left from the top. This indicates a visual losing. 4. In window 4 we see the presentation of the waveform for a complete cycle. I mean a tikc and a tock. Let's say "normal" A quick inspection of this window can help determine the quality of the Escapement performance. 5. In window 5 we find 5 and 5 '. They are two different windows dedicated to each one of the escape cycles. The wave form is elongated which allows a very precise detail of the escapement phenomenon that only lasts for milli-seconds. 6. Calibrate button. This has to be done with the help of a very stable watch. Whose error rate we know and is less than 1 second per week. It can be a quartz watch of very good quality. The watch is placed in the microphone, and the calibration button is pressed for a time of about 15 minutes. The result against the known error value of our master clock will be the setting that will be entered in window No. 7.

7. Calibration correction value window. Although our computer has a very stable oscillator crystal, this is far from accurate enough to serve as a time pattern to a watch controller. Therefore it must be calibrated to determine the error of our "system". And make the respective correction. CALIBRATION: To calibrate the program, you need a clock with the accuracy rate less than 5 seconds per month. We use a 1 BPS or 3600 BPS step-by-step motor quartz watch. We put the watch in the microphone. Press the Calibration button and the program does its job. Cal progress. After about 15 minutes, the calibration will stop and give us the adjustment value that our computer must have. The program places the calibration value in the Cal box. The program is now ready for use with confidentiality. This of course assumes that the clock that was used for calibration is high accuracy. We suggest a quartz watch that has no "inhibition system". Now press the calibration button again to exit Calibration mode.

The calibration is done. HOW TO USE THE OSCILO-ESCAPE tg Timing Machine, or Timegrapher? Before servicing a clock, the tg software can be used to determine faults and the watch status. What to look for? In the Paper Strip window, with approximately 80% of the winds, the gaining or losing rate of the watch will be analyzed. And you can determine the grade of beat error in the watch. If it were, the separation between the successions of points would be broad. They would appear as separate parallel lines. The more separated the more beat error there is. In general, a quick pre-service inspection of a watch can help us detect faults that will not go away with the cleaning and lubrication service. It is actually an inspection in search of bigger mistakes. The amplitude, the beat error and the rate will be modified in the cleaning and set-up service. And in view of the fact that when doing the service must move the devices that controls the beat error as the rate, that will be corrected in the final part of the service. AFTER SERVICE. FIRST CORRECTION: BEAT ERROR. First, determine whether the Balance Wheel is in equilibrium. While the watch is being armed, it is visually inspected that the ellipse ruby roller jewel (impulse pin) is "centered" relative to the banking pins. If not, there are two possibilities. A) That the watch mechanism does not have a movable hairspring stud, which

will lead to the "centering" by moving the collet on the balance staff. And B) if the hairspring stud is mobile, it moves to find the "centered" point. The Blue Arrow points to the hairspring stud. This moveable. With it we corrected beat error. The red arrow points to the regulator. With it we correct rate. It should be noted that the manipulation of these two components is very sensitive. Not a few experienced watchmakers have slipped in making the correction by damaging the delicate mechanism of the balance wheel. For this reason do not practice with a Patek Philippe watch.

We test with my fake Rolex watch. Here you can see a beat error of 1.6 ms. In the red circle. We see in the virtual paper strip (light blue circle), the parallel lines with a separation. We act first on hairspring stud. The red circle shows the "instant" of the setting. The beat error is corrected. The lines are no longer parallel.

Note that now is a single line. And numerically it is reflected in 0.0 ms beat error. We acted on hairspring stud. Now we correct the regulator. Note that the correction was made on the fly and that is reflected in the "paper strip". And again we must stress that the adjustment, particularly when less than 10 seconds a day to correct, requires great precision in the manipulation of the regulator.

Patience of watchmaker. However experience indicates that the watch needs to be corrected in several positions. You cannot rely on a single watch position. Averages must be made in at least 4 positions. Dial up, Dial down, Crown up, Crown down. WHAT ARE THE COMPONENTS OF THE WAVEFORM GRAPH? Each of the 2 cycles of the waveform can be divided into 3 components: 1. - Unlock. (Circle Yellow) 2. - Impulse, (Circle Red) and 3. - Lock or drop. (Circle Blue) See it in circles. For simplicity we only use a waveform. WHERE HAVE THEIR SOURCE THE THREE SOUND EVENTS OF THE WAVE FORM? The First sound: The Unlock. The contact of the ruby ellipse in the fork of the pallet lever generates the first sound indicated here in green.

The second sound that may be the weakest, takes place in two parts: On the wheel tooth sliding along the inclined surface of the pallet, and some slight friction in the ruby ellipse and the pallets fork. The Second Sound: The Impulse. Here we see the two places where the event marked in green in the waveform takes place. It is the impulse.

The third event takes place on the locking face by stopping the movement of the escape wheel, "abruptly". That is why he is the strongest. That is why he is the strongest. However, it also occurs when the banking pin stops the path of the anchor lever. The third sound: The Drop Here the sound of "drop" or lock originates. We must clarify that each watch differs from another in its characteristic waveform. The watchmaker must have experience in the control of the escapement mechanism and in that direction, the software tg Timing Machine will be of great help. Good friends. Keep enjoying the wonderful tg program. Guido Velasquez